Core Losses in Co-Rich Inductors with Tunable Permeability

High frequency, low loss power systems enable electrified aircraft propulsion. Filter inductors that reduce noise in high current systems can account for 50% of the motor drive mass. Efficient inductor cores with tunable permeability reduce system mass by producing less heat, that removes heat sink mass. Requirements for filter inductors vary based on the chosen topology, but all inductor cores must operate below saturation levels. As the saturation flux density is limited (less than ~2 T), high differential current applications require cores with low relative permeabilities. The large induced anisotropies possible in Co-rich metal amorphous nanocomposite materials enables gapless inductors with relative permeabilities down to ~20. These materials have fine grain size ~8nm with a faulted, close packed structure. The impact of different processing methods on core losses are presented along with comparison to other low permeability soft magnetic materials.

Leary, Alex

Control of the permeability loss-peak frequency of Ni81Fe19 thin films through laser ablation of triangular and square cluster geometries

Laser ablation arrays of triangular and square shaped clusters, comprised of 23 micrometers diam circular holes, are defined upon 100 nm thick Ni81Fe19 films used to control the rf permeability spectra. Cluster-to-cluster spacing is varied from 200 to 600 micrometers. For each geometry it is found that the loss peak frequency and permeability magnitude shift lower, in a step-wise fashion, at a cluster-to-cluster spacing between 275 and 300 micrometers. The nonlinear shift in the behavior of the permeability spectra correlates with a dramatic increase in domain wall density. c2000 American Institute of Physics.

NASA Discipline Life Sciences Technologies

Gas Permeability of Lunar Regolith Simulants

Lunar lander descent engines produce plume-surface interactions (PSI) effect that can generate high-speed regolith ejecta which can pose a risk to surface and orbital assets. The physics of plume-surface interactions during the descent and landing of a lunar lander depends on the gas permeability of the lunar surface regolith. This presentation will discuss gas permeability measurements that have been performed at NASA Kennedy Space Center to help inform the development of plume-surface interaction models and large-scale PSI ground tests. Results will be presented of gas permeability measurements for lunar regolith simulants that were conducted under vacuum conditions as a function of the granular mineral material's mass density, compaction, and water content.

gas permeability

Stereochemically‐Controlled Fluorinated Copolymers for Selectively Permeable Barrier Applications

Selective oxygen permeability coupled with low water vapor transmission is essential for biomedical and packaging applications requiring controlled oxygen flux under humid conditions. However, most high‐performance barrier polymers depend on perfluoroalkyl substances (PFAS), whose persistence and regulatory restrictions limit their long‐term applicability. We designed a series of stereocontrolled thiol‐yne‐based polyesters, including both fluorinated and non‐fluorinated variants, for selective oxygen permeability with considerable water barrier performance. Tailoring polymer crystallinity and morphology tuned both oxygen transport and mechanical properties. Fluorinated polymers demonstrated enhanced hydrophobicity and water resistance while maintaining oxygen diffusivity within a range relevant to oxygen‐sensing applications. Structure–property relationships were elucidated through small‐ and wide‐angle X‐ray scattering, revealing semi‐crystalline domains influenced by fluorine content and dithiol chain length. Barrier performance was rigorously evaluated via water vapor transmission rate and dynamic vapor sorption, showing reduced water uptake with increasing dithiol monomer length and crystallinity. In conclusion, this work introduces a PFAS‐free alternative to conventional barrier materials and establishes a tunable materials platform with potential relevance for biomedical devices and packaging systems requiring controlled oxygen permeability.

36 MATERIALS SCIENCE

"Hidden" hydrothermal technical potential & technoeconomics: Revealing permeability & fluids with more data

Historical hydrothermal estimates have largely relied on temperature or heat flow estimates ignoring the need for natural flowing fluids. More accurate hydrothermal estimates require some indication of permeability and fluids that naturally exist in the subsurface. This paper describes a novel approach that includes proxies of permeability and fluids in hydrothermal estimates by leveraging the relatively data-rich Great Basin. Specifically, nameplate capacities (megawatts) of operating geothermal plants, negative (0 megawatt) locations and 48 geophysical and geologic features are used to used in eXtreme Gradient Boosting (XGBoost) regression to make hydrothermal capacity predictions. Additionally, this work inputs the XGBoost-based hydrothermal predictions into the Renewable Energy Potential (reV) model to quantify technical capacity, its uncertainty and techno-economics. Compared to historical hydrothermal estimates, these predictions adhere to the 37 operating geothermal plants and negative locations. We present a method for subsampling the negative sites to bring the labels into balance that uses the geologic domain knowledge to proportionally represent negatives. Overall, the distributions of the hydrothermal technical capacity and the site levelized cost of energy are respectively much tighter, lower and more accurate than the previous estimates for the Great Basin, as they include geological and geophysical surrogates for permeability and fluids. Percentile (50th and 90th, median and high estimate, respectively) models provide bookends for these metrics.

13 HYDRO ENERGY

Modeling gas migration through clay-based buffer material using coupled multiphase fluid flow and geomechanics with stress-dependent gas permeability

A model for gas migration through clay-based buffer material is developed for modeling gas generation and migration associated with deep geologic nuclear waste disposal. The model is based on a multiphase fluid flow and geomechanics simulator that is adapted to consider enhanced gas flow when gas pressure is high enough to approach the confining stress magnitude. A key feature in the model is a direct coupling between gas permeability and stress, through a non-linear stress-dependent permeability function. The model was first tested and calibrated by modelling two different laboratory gas migration tests on Wyoming (MX-80) bentonite samples. The calibrated model was then applied to model gas migration through a bentonite buffer of a large-scale gas injection test (Lasgit) conducted at the Äspö Hard Rock Laboratory in Sweden. Observed preferential gas migration along interfaces (between compacted blocks and along the canister surface) required explicit representation of such interfaces in the model. The model with the stress-dependent gas permeability accurately captured observed experimental responses in terms of gas breakthrough time, peak gas pressure, and cumulative gas flow rates. The calibrated model was finally applied to simulate migration of hydrogen gas generated within a breached nuclear waste canister over 10,000 years, involving migration of much larger gas volumes. For the considered gas generation rate and host rock properties, the generated gas could migrate through the bentonite buffer and released into the surrounding host rock at a maximum gas pressure somewhat higher than the initial total stress, though a significant amount of hydrogen remained within the buffer. This modelling sets the stage for further detailed analysis of the impact of hydrogen gas generation on the long-term performance of nuclear waste repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Quantifying the Effect of Pore‐Size Dependent Wettability on Relative Permeability Using Capillary Bundle Model

Abstract Relative permeability is a key parameter for characterizing the multiphase flow dynamics in porous media at macroscopic scale while it can be significantly impacted by wettability. Recently, it has been reported in microfluidic experiments that wettability is dependent on the pore size (Van Rooijen et al., 2022). To investigate the effect of pore‐size‐dependent wettability on relative permeability, we propose a theoretical framework informed by digital core samples to quantify the deviation of relative permeability curves due to wettability change. We find that the significance of impact is highly dependent on two factors: (i) the function between contact angle and pore size (ii) overall pore size distribution. Under linear function, this impact can be significant for tight porous media with a maximum deviation of 1,000%.

Yu, Siqin

Fault Slip and Fluid Flow: Seismic Source Analysis to Assess Role of Multiple Slip Patches in Fault Permeability

The relationship between fault reactivation, microearthquakes (MEQs), and permeability evolution during fluid injection plays a critical role in energy harvesting and waste disposal. Recent studies have demonstrated the possibility of predicting fault permeability using cumulative seismic moments of MEQs quantitatively. To understand the underlying physical processes, we conduct fault reactivation experiments using Utah FORGE granitoid and analyze acoustic emission (AE) signals generated during stepwise increases in fluid injection pressure. Frequency analysis of thousands of calibrated AE signals reveals that fault reactivation produces multiple AE source patches with millimeter-scale radii—smaller than the sample fault radius. The cumulative area of the reactivated patches covers the fault multiple times over (∼10x–50x area) for each pressure step. These findings provide mechanistic insight that measured permeability enhancement is not driven by a single large slip event, but by the sequential and interacting activation of multiple slip patches that create a continuous flow pathway.

Nurshal, M. E. M. [Pennsylvania State University,

Study of permeability characteristics of membranes

Pressure-permeation experiments were performed with the concentration-clamp cell. Streaming potentials and hydraulic permeabilities were measured for an AMF C-103 cation-exchange membrane bounded by 0.1 N NaCl solutions. The streaming potential calculated from the slope of the recorded potential differences versus the applied pressure, yields a value of 1.895 millivolt/dekabar. When comparison with other membranes of similar characteristics could be made, good agreement was found. The values of the hydraulic permeability varied somewhat with the applied pressure difference and are between 1.3 x 10 to the minus 8th power and 3.9 x 10 to the minus 8th power sq cm/dekabar-sec. The specific hydraulic permeabilities were also calculated and compared with data from the literature. Fair agreement was found. The diffusion coefficient of the chloride ion in the AMF C-103 membrane was calculated, using Fick's first law of diffusion based on ion concentrations calculated from the Donnan equilibrium concentration of Cl(-).

Spiegler, K. S.

Iron abundance and magnetic permeability of the moon

A larger set of simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a whole-moon hysteresis curve, from which a new value of global lunar permeability is determined to be mu = 1.012 + or - 0.006. The corresponding global induced dipole moment is 2.1 x 10 to the 18th power gauss-cu cm for typical inducing fields of .0001 gauss in the lunar environment. From the permeability measurement, lunar free iron abundance is determined to be 2.5 + or - 2.0 wt. %. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) is calculated for two assumed compositional models of the lunar interior: a free iron/orthopyroxene lunar composition and a free iron/olivine composition. The overall lunar total iron abundance is determined to be 9.0 + or - 4.7 wt. %. Other lunar models with a small iron core and with a shallow iron-rich layer are discussed in light of the measured global permeability.

Parkin, C. W.

Lunar electrical conductivity, permeability,and temperature from Apollo magnetometer experiments

Magnetometers were deployed at four Apollo sites on the moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments were used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients, were analyzed to calculate and electrical conductivity profile for the moon, and those profiles were used to calculate the lunar temperature for an assumed lunar material of olivine. Simultaneous measurements by magnetometers on the lunar surface and in orbit around the moon were use to construct a whole-moon hysteresis curve, from which the global lunar magnetic permeability is determined. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) was calculated for two assumed compositional models of the lunar interior. Other lunar models with an iron core and with a shallow iron-rich layer also discussed in light of the measured global lunar permeability. Simultaneous magnetic field and solar plasma pressure measurements show that the remanent fields at the Apollo 12 and 16 sites interact with, and are compressed by, the solar wind. Velocities and thicknesses of the earth's magnetopause and bow shock were also estimated from simultaneous magnetometer measurements.

Dyal, P.

Changes in mast cells and in permeability of mesenteric microvessels under the effect of immobilization and electrostimulation

It was shown that a reduction in the amount of mast cells in the mesentery and an increase in their degranulation was accompanied by an increase in vascular permeability of rat mesentery. It is supposed that immobilization and electrostimulation causing degranulation of mast cells prompted histamine and serotonin release from them, thus increasing the permeability of the venular portion of the microvascular bed. Prophylactic use of esculamin preparation with P-vitaminic activity decreased mast cell degranulation, which apparently prolonged the release of histamine and serotonin from them and normalized vascular permeability.

Gorizontova, M. P.

Vapor-liquid phase separator permeability results

Continued studies are described in the area of vapor-liquid phase separator work with emphasis on permeabilities of porous sintered plugs (stainless steel, nominal pore size 2 micrometer). The temperature dependence of the permeability has been evaluated in classical fluid using He-4 gas at atmospheric pressure and in He-2 on the basis of a modified, thermosmotic permeability of the normal fluid.

Yuan, S. W. K.

Effect of water on hydrogen permeability

Doping of hydrogen with CO and CO2 was developed to reduce hydrogen permeation in Stirling engines by forming a low permeability oxide coating on the inner surface of the heater head tubes. Although doping worked well, under certain circumstances the protective oxide could be chemically reduced by the hydrogen in the engine. Some oxygen is required in the hydrogen to prevent reduction. Eventually, all the oxygen in the hydrogen gas - whatever its source - shows up as water. This is the result of hydrogen reducing the CO, CO2, or the protective inner surface oxides. This water can condense in the engine system under the right conditions. If the concentration of water vapor is reduced to a low enough level, the hydrogen can chemically reduce the oxide coating, resulting in an increase in permeability. This work was done to define the minimum water content required to avoid this reduction in the oxide coating. The results of this testing show that a minimum of approximately 750 ppm water is required to prevent an increase in permeability of CG-27, a high temperature metal alloy selected for Stirling engine heater tubes.

Hulligan, David

A complex permittivity and permeability measurement system for elevated temperatures

The three goals of this research include: (1) to fully develop a method to measure the permittivity and permeability of special materials as a function of frequency in the range of 2.6 to 18 GHz, and of temperature in the range of 25 to 1100 C; (2) to assist LeRC in setting up an in-house system for the measurement of high-temperature permittivity and permeability; and (3) to measure the complex permittivity and permeability of special materials as a function of frequency and temperature to demonstrate the capability of the method. The method chosen for characterizing the materials relies on perturbation of a resonant cavity with a small volume of sample material. Different field configurations in the cavity can be used to separate electric and magnetic effects. The cavity consists of a section of rectangular waveguide terminated at each end of a vertical slot iris. In the center of one wall is a small hole through which the sample is introduced.

Friederich, Paul

A complex permittivity and permeability measurement system for elevated temperatures

The three goals of this research include: (1) to fully develop a method to measure the permittivity and permeability of special materials as a function of frequency in the range of 2.6 to 18 GHz, and of temperatures in the range of 25 to 1100 C; (2) to assist LeRC in setting up an in-house system for the measurement of high-temperature permittivity and permeability; and (3) to measure the complex permittivity and permeability of special materials as a function of frequency and temperature to demonstrate the capability of the method. The method chosen for characterizing the materials relies on perturbation of a resonant cavity with a small volume of sample material. Different field configurations in the cavity can be used to separate electric and magnetic effects. The cavity consists of a section of rectangular waveguide terminated at each end of a vertical slot iris. The center of one wall is a small hole through which the sample is introduced.

Friederich, Paul

Atrial natriuretic factor increases vascular permeability

An increase in central blood volume in microgravity may result in increased plasma levels of atrial natriuretic factor (ANF). In this study, it was determined whether ANF increases capillary permeability to plasma protein. Conscious, bilaterally nephrectomized male rats were infused with either saline, ANF + saline, or hexamethonium + saline over 2 h following bolus injections of (I-125)-albumin and (C-14)-dextran of similar molecular size. Blood pressure was monitored, and serial determinations of hematocrits were made. Animals infused with 1.0 microg/kg per min ANF had significantly higher hematocrits than animals infused with saline vehicle. Infusion of ANF increased the extravasation of (I-125)-albumin, but not (C-14)-dextran from the intravascular compartment. ANF also induced a depressor response in rats, but the change in blood pressure did not account for changes in capillary permeability to albumin; similar depressor responses induced by hexamethonium were not accompanied by increased extravasation of albumin from the intravascular compartment. ANF may decrease plasma volume by increasing permeability to albumin, and this effect of ANF may account for some of the signs and symptoms of space motion sickness.

Lockette, Warren

Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

Upchurch, Billy T.