Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase contrast microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Polarization and phase pulse shaping applied to structural contrast in nonlinear microscopy imaging

The spectral polarization shaping of ultrashort pulses is shown to allow retrieval of two-dimensional individual tensorial components of the second-harmonic-generation response of molecular samples in nonlinear microscopy imaging. This configuration, which cannot be performed by traditional polarization-controlled excitation, provides a structural contrast that can be directly related to information on the local symmetry and order of the sample, with submicrometric spatial resolution. Phase shaping, in addition to polarization spectral manipulation, is proposed as a possible scheme for imaging individual tensorial components without the need for a spectral information extraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interpretable and Efficient Interferometric Contrast in Scanning Transmission Electron Microscopy with a Diffraction-Grating Beam Splitter

Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. Here, we apply the technique to image nanoparticles, carbon sub- strates and electric fields. The contrast observed in experiments agrees well with contrast predicted in simulations.

36 MATERIALS SCIENCE↗

Novel self-assembled two-dimensional layered oxide structure incorporated with Au nanoinclusions towards multifunctionalities

Two-dimensional (2D) layered oxides have recently attracted wide attention owing to the strong coupling among charges, spins, lattice, and strain, which allows great flexibility and opportunities in structure designs as well as multifunctionality exploration. In parallel, plasmonic hybrid nanostructures exhibit exotic localized surface plasmon resonance (LSPR) providing a broad range of applications in nanophotonic devices and sensors. A hybrid material platform combining the unique multifunctional 2D layered oxides and plasmonic nanostructures brings optical tuning into the new level. Here, a novel self-assembled Bi 2 MoO 6 (BMO) 2D layered oxide incorporated with plasmonic Au nanoinclusions has been demonstrated via one-step pulsed laser deposition (PLD) technique. Comprehensive microstructural characterizations, including scanning transmission electron microscopy (STEM), differential phase contrast imaging (DPC), and STEM tomography, have demonstrated the high epitaxial quality and particle-in-matrix morphology of the BMO-Au nanocomposite film. DPC-STEM imaging clarifies the magnetic domain structures of BMO matrix. Three different BMO structures including layered supercell (LSC) and superlattices have been revealed which is attributed to the variable strain states throughout the BMO-Au film. Owing to the combination of plasmonic Au and layered structure of BMO, the nanocomposite film exhibits a typical LSPR in visible wavelength region and strong anisotropy in terms of its optical and ferromagnetic properties. This study opens a new avenue for developing novel 2D layered complex oxides incorporated with plasmonic metal or semiconductor phases showing great potential for applications in multifunctional nanoelectronics devices.

36 MATERIALS SCIENCE↗

Hard x-ray Zernike Microscopy Reaches 30 nm Resolution

Since its invention in 1930, Zernike phase contrast has been a pillar in optical microscopy and more recently in x-ray microscopy, in particular for low-absorption-contrast biological specimens. We experimentally demonstrate that hard-x-ray Zernike microscopy now reaches a lateral resolution below 30 nm while strongly enhancing the contrast, thus opening many new research opportunities in biomedicine and materials science.

43 PARTICLE ACCELERATORS↗

Detection of secondary phases in duplex stainless steel by magnetic force microscopy and scanning Kelvin probe force microscopy

The secondary phase transformations in a commercial super duplex stainless steel were investigated by micro-chemical analyses and high resolution scanning probe microscopy. Energy dispersive X-ray and electron probe detected ferrite and austenite as well as secondary phases in unetched aged duplex stainless steel type 25Cr-7Ni-3Mo. Volta potential indicated that nitride and sigma appeared more active than ferrite, while secondary austenite and austenite presented a nobler potential. Reversal order in nobility is thought to be attributable to the potential ranking provided by oxide nature diversity as a result of secondary phase surface compositions on steel. After eutectoid transformation, secondary austenite was detected by electron probe microanalysis, whereas atomic force microscopy distinguished this phase from former austenite by image contrast. Magnetic force microscopy revealed a “ghosted” effect on the latter microstructure probably derived from metal memory reminiscence of mechanical polishing at passivity and long range magnetic forces of ferrite phase. - Highlights: • Nobility detection of secondary phases by SKPFM in DSS particles is not a straightforward procedure. • As Volta potential and contrast are not always consistent SKPFM surface oxides is thought played an important role in detection. • AFM distinguished secondary austenite from former austenite by image contrast though SEM required EPMA.

36 MATERIALS SCIENCE↗

X-ray Nanocomputed Tomography in Zernike Phase Contrast for Studying 3D Morphology of Li–O 2 Battery Electrode

In this work, we investigated the lithium peroxide (Li 2 O 2 ) and pore size distribution in lithium-O 2 battery electrodes at different states of charge using transmission X-ray microscopy coupled with Zernike phase contrast to carry out nano-Computed Tomography. We report that such technique enables, at the nanoscale, to distinguish light elements such as carbon and Li 2 O 2 in Li-O 2 battery cathode electrodes. We verified by wave-propagation simulation that this approach efficiently improves the contrast of images in comparison with the pure absorption. The Li 2 O 2 distribution and thickness, interphases, and pore network are visualized and quantified, which give a valuable insight into our cathode architecture. From this 3D analysis, we highlight modifications of the air-cathode morphology and the Li 2 O 2 spatial organization as well as their potential implication in terms of carbon surface passivation and pore-clogging. After the full recharge process, this technique can also reveal the spatial distribution of the residual Li 2 O 2 and other byproducts.

25 ENERGY STORAGE↗

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Selection of higher eigenmode amplitude based on dissipated power and virial contrast in bimodal atomic force microscopy

This paper explores the effect of the amplitude ratio of the higher to the fundamental eigenmode in bimodal atomic force microscopy (AFM) on the phase contrast and the dissipated power contrast of the higher eigenmode. We explore the optimization of the amplitude ratio in order to maximize the type of contrast that is most relevant to the particular study. Specifically, we show that the trends in the contrast range behave differently for different quantities, especially the dissipated power and the phase, with the former being more meaningful than the latter (a similar analysis can be carried out using the virial, for which we also provide a brief example). Our work is based on numerical simulations using two different conservative-dissipative tip-sample models, including the standard linear solid and the combination of a dissipation coefficient with a conservative model, as well as experimental images of thin film Nafion{sup ®} proton exchange polymers. We focus on the original bimodal AFM method, where the higher eigenmode is driven with constant amplitude and frequency (i.e., in “open loop”).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Three-Dimensional Reconstruction Algorithm for Scanning Transmission Electron Microscopy Data from a Single Sample Orientation

Abstract Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data. We apply the approach to a lead iridate, PbIrO, and yttrium-stabilized zirconia, YZrO, heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction. We demonstrate that Pb–Ir atomic columns are visible in the uppermost layers of the reconstructed volume. We compare this approach to the alternative techniques of depth sectioning using differential phase contrast scanning transmission electron microscopy (DPC-STEM) and multislice ptychographic reconstruction.

47 OTHER INSTRUMENTATION↗

Phase Contrast Wavefront Sensing for Adaptive Optics

Most ground-based adaptive optics systems use one of a small number of wavefront sensor technologies, notably (for relatively high-order systems) the Shack-Hartmann sensor, which provides local measurements of the phase slope (first-derivative) at a number of regularly-spaced points across the telescope pupil. The curvature sensor, with response proportional to the second derivative of the phase, is also sometimes used, but has undesirable noise propagation properties during wavefront reconstruction as the number of actuators becomes large. It is interesting to consider the use for astronomical adaptive optics of the "phase contrast" technique, originally developed for microscopy by Zemike to allow convenient viewing of phase objects. In this technique, the wavefront sensor provides a direct measurement of the local value of phase in each sub-aperture of the pupil. This approach has some obvious disadvantages compared to Shack-Hartmann wavefront sensing, but has some less obvious but substantial advantages as well. Here we evaluate the relative merits in a practical ground-based adaptive optics system.

adaptive optics↗

Analysis of gene expression levels in individual bacterial cells without image segmentation

Highlights: Black-Right-Pointing-Pointer We present a method for extracting gene expression data from images of bacterial cells. Black-Right-Pointing-Pointer The method does not employ cell segmentation and does not require high magnification. Black-Right-Pointing-Pointer Fluorescence and phase contrast images of the cells are correlated through the physics of phase contrast. Black-Right-Pointing-Pointer We demonstrate the method by characterizing noisy expression of comX in Streptococcus mutans. -- Abstract: Studies of stochasticity in gene expression typically make use of fluorescent protein reporters, which permit the measurement of expression levels within individual cells by fluorescence microscopy. Analysis of such microscopy images is almost invariably based on a segmentation algorithm, where the image of a cell or cluster is analyzed mathematically to delineate individual cell boundaries. However segmentation can be ineffective for studying bacterial cells or clusters, especially at lower magnification, where outlines of individual cells are poorly resolved. Here we demonstrate an alternative method for analyzing such images without segmentation. The method employs a comparison between the pixel brightness in phase contrast vs fluorescence microscopy images. By fitting the correlation between phase contrast and fluorescence intensity to a physical model, we obtain well-defined estimates for the different levels of gene expression that are present in the cell or cluster. The method reveals the boundaries of the individual cells, even if the source images lack the resolution to show these boundaries clearly.

60 APPLIED LIFE SCIENCES↗

X-ray microscopy of soft and hard human tissues

The simultaneous post mortem visualization of soft and hard tissues using absorption-based CT remains a challenge. If the photon energy is optimized for the visualization of hard tissue, the surrounding soft tissue components are almost X-ray transparent. Therefore, the combination with other modalities such as phase-contrast CT, magnetic resonance microscopy, and histology is essential to detect the anatomical features. The combination of the 2D and 3D data sets using sophisticated segmentation and registration tools allows for conclusions about otherwise inaccessible anatomical features essential for improved patient treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Diamond Membrane-Based X-Ray Optics: Fresnel Zone Plates, Beam Stops, and Grids

This project was proposed to develop the design and fabrication of zone plates for hard X-ray focusing up to 25 keV photon energies with 20 nm resolution (with zone doubling), based on diamond membranes. The benefits of using diamond are: improved mechanical robustness which among other advantages prevents collapse of high-aspect-ratio ring structures, a known high-aspect-ratio etch method, and excellent compatibility with other processes, excellent radiation hardness, extremely low X-ray absorption, and significantly improved thermal/dimensional stability as compared to alternative materials. The Phase I findings enable Phase II goals as well as significant progress in other diamond-membrane devices, such as diamond-supported X-ray optics (beam stops, apertures, phase shift disks for phase contrast X-ray microscopy, grids, resolution targets, coded apertures for coherence measurements, etc), X-ray windows and membrane–based detectors. Zone plates with outermost zones of 60 nm were written in 500 nm electron resist and transferred to a depth of up to 1.8 mm (exceeding the expectations) into a stack of engineered multilayer ultra-nano-crystalline diamond alternating non-conductive and conductive layers. The active material for focusing was added on top (Au and Ir). Several processes were investigated and validated to enable in Phase II the enhancement of the thickness of the structures, including polishing the over-plated zone plates and growing diamond on top of Ir-coated zone plates without the destruction of the nanostructures underneath. The zone plates were geometrically characterized.

07 ISOTOPE AND RADIATION SOURCES↗

Exploring semiconductor quantum dots and wires by high resolution electron microscopy

We review in this communication our contribution to the structural characterisation of semiconductor quantum dots and wires by high resolution electron microscopy, both in phase-contrast and Z-contrast modes. We show how these techniques contribute to predict the preferential sites of nucleation of these nanostructures, and also determine the compositional distribution in 1D and 0D nanostructures. The results presented here were produced in the framework of the European Network of Excellence entitled 'Self-Assembled semiconductor Nanostructures for new Devices in photonics and Electronics (SANDiE)'.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable CHA/AEI Zeolite Intergrowths with A Priori Biselective Organic Structure‐Directing Agents: Controlling Enrichment and Implications for Selective Catalytic Reduction of NOx

Abstract A novel ab initio methodology based on high‐throughput simulations has permitted designing unique biselective organic structure‐directing agents (OSDAs) that allow the efficient synthesis of CHA/AEI zeolite intergrowth materials with controlled phase compositions. Distinctive local crystallographic ordering of the CHA/AEI intergrowths was revealed at the nanoscale level using integrated differential phase contrast scanning transmission electron microscopy (iDPC STEM). These novel CHA/AEI materials have been tested for the selective catalytic reduction (SCR) of NOx, presenting an outstanding catalytic performance and hydrothermal stability, even surpassing the performance of the well‐established commercial CHA‐type catalyst. This methodology opens the possibility for synthetizing new zeolite intergrowths with more complex structures and unique catalytic properties.

Bello‐Jurado, Estefanía↗

Tunable CHA/AEI Zeolite Intergrowths with A Priori Biselective Organic Structure‐Directing Agents: Controlling Enrichment and Implications for Selective Catalytic Reduction of NOx

Abstract A novel ab initio methodology based on high‐throughput simulations has permitted designing unique biselective organic structure‐directing agents (OSDAs) that allow the efficient synthesis of CHA/AEI zeolite intergrowth materials with controlled phase compositions. Distinctive local crystallographic ordering of the CHA/AEI intergrowths was revealed at the nanoscale level using integrated differential phase contrast scanning transmission electron microscopy (iDPC STEM). These novel CHA/AEI materials have been tested for the selective catalytic reduction (SCR) of NOx, presenting an outstanding catalytic performance and hydrothermal stability, even surpassing the performance of the well‐established commercial CHA‐type catalyst. This methodology opens the possibility for synthetizing new zeolite intergrowths with more complex structures and unique catalytic properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗