Search NASA⌕ Search

SEARCH · Search NASA

Results for “Piezoelectric drills”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

62 records · Page 4

Creating High Temperature Ferroelectrics by Using Ternary Components with Limited Solubility

High temperature ferroelectrics are needed for actuator applications ranging from drilling on the surface of Venus to fuel modulation in jet engines. Machine learning in previous work has dramatically reduced search space and produced new candidates for experimentation. It is possible to create high temperature piezoelectrics by changing the end member of ternary systems. The starting point was near the morphotropic phas boundary between BiScO3(BS) and PbTiO3 (PT) (38%/62%). The third end member was suggested by machine learning to create a high Tc with limited solubility; BiCo0.88Fe0.12O3 (BCF).

Hirt, Benjamin↗

Active Struts With Variable Spring Stiffness and Damping

An ultrasonic rock-abrasion tool (URAT) was developed using the same principle of ultrasonic/sonic actuation as that of the tools described in two prior NASA Tech Briefs articles: Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. Hence, like those tools, the URAT offers the same advantages of low power demand, mechanical simplicity, compactness, and ability to function with very small axial loading (very small contact force between tool and rock). Like a tool described in the second of the cited previous articles, a URAT includes (1) a drive mechanism that comprises a piezoelectric ultrasonic actuator, an amplification horn, and a mass that is free to move axially over a limited range and (2) an abrasion tool bit. A URAT tool bit is a disk that has been machined or otherwise formed to have a large number of teeth and an overall shape chosen to impart the desired shape (which could be flat or curved) to the rock surface to be abraded. In operation, the disk and thus the teeth are vibrated in contact with the rock surface. The concentrated stresses at the tips of the impinging teeth repeatedly induce microfractures and thereby abrade the rock. The motion of the tool induces an ultrasonic transport effect that displaces the cuttings from the abraded area. The figure shows a prototype URAT. A piezoelectric-stack/horn actuator is housed in a cylindrical container. The movement of the actuator and bit with respect to the housing is aided by use of mechanical sliders. A set of springs accommodates the motion of the actuator and bit into or out of the housing through an axial range between 5 and 7 mm. The springs impose an approximately constant force of contact between the tool bit and the rock to be abraded. A dust shield surrounds the bit, serving as a barrier to reduce the migration of rock debris to sensitive instrumentation or mechanisms in the vicinity. A bushing at the tool-bit end of the housing reduces the flow of dust into the actuator and retains the bit when no axial load is applied.

Farley, Gary L.↗

Ultrasonically Actuated Tools for Abrading Rock Surfaces

An ultrasonic rock-abrasion tool (URAT) was developed using the same principle of ultrasonic/sonic actuation as that of the tools described in two prior NASA Tech Briefs articles: Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. Hence, like those tools, the URAT offers the same advantages of low power demand, mechanical simplicity, compactness, and ability to function with very small axial loading (very small contact force between tool and rock). Like a tool described in the second of the cited previous articles, a URAT includes (1) a drive mechanism that comprises a piezoelectric ultrasonic actuator, an amplification horn, and a mass that is free to move axially over a limited range and (2) an abrasion tool bit. A URAT tool bit is a disk that has been machined or otherwise formed to have a large number of teeth and an overall shape chosen to impart the desired shape (which could be flat or curved) to the rock surface to be abraded. In operation, the disk and thus the teeth are vibrated in contact with the rock surface. The concentrated stresses at the tips of the impinging teeth repeatedly induce microfractures and thereby abrade the rock. The motion of the tool induces an ultrasonic transport effect that displaces the cuttings from the abraded area. The figure shows a prototype URAT. A piezoelectric-stack/horn actuator is housed in a cylindrical container. The movement of the actuator and bit with respect to the housing is aided by use of mechanical sliders. A set of springs accommodates the motion of the actuator and bit into or out of the housing through an axial range between 5 and 7 mm. The springs impose an approximately constant force of contact between the tool bit and the rock to be abraded. A dust shield surrounds the bit, serving as a barrier to reduce the migration of rock debris to sensitive instrumentation or mechanisms in the vicinity. A bushing at the tool-bit end of the housing reduces the flow of dust into the actuator and retains the bit when no axial load is applied.

Dolgin, Benjamin↗

In Situ Analysis of Martian Phyllosilicates Using the Chemin Minerological Instrument on Mars Science Laboratory

The CheMin minerological instrument on Mars Science Laboratory (MSL'09) [1] will return quantitive Xray diffraction data (XRD) and quantative X-ray fluorescence data (XRF;14<Z<92) from scooped soil samples and drilled rock powders collected from the Mars surface. Samples of 45-65 mm 3 from material sieved to less than 150 micrometers will be delivered through a funnel to one of 27 reusable sample cells (five additional cells on the sample wheel contain diffraction of fluorescence standards). Sample cells are 8-mm diamater discs with 7-micrometer thick Mylar or Kapton windows spaced 170 micrometers apart. Within this volume, the sample is shaken by piezoelectric vibration at sonic frequencies, causing the powder to flow past a narrow, collimated -ray beam in random orientation can be obtained even from minnerals exhibiting strong preferred orientation such as phylosilicates.

Blake, David F.↗

USDC based rapid penetrator of packed soil

Environment protection requires more testing and analysis tools. To detect buried chemical containers or other objects embedded in soil and avoid possible damages of them, a penetrator of packed soil operated using low pushing force was developed. The design was based on a novel driving mechanism of the ultrasonic/sonic driller/corer (USDC) device developed in the NDEAA lab at JPL [Bar-Cohen et al 2001, Bao et al 2003]. In the penetrator, a small free-flying mass is energized by a piezoelectric transducer and impacts a rod probe on its shoulder at frequencies of hundreds times per second. The impacts help the probe to penetrate the packed soil rapidly. A great reduction of the needed pushing force for penetration was achieved. The details of the design of the prototype penetrator and the results of performance tests are presented.

sampling↗

Micro Acoustic Resonant Chambers for Heating/Agitating/Mixing (MARCHAM)

A variety of applications require the mixing and/or heating of a slurry made from a powder/fluid mixture. One of these applications, Sub Critical Water Extraction (SCWE), is a process where water and an environmental powder sample (sieved soil, drill cuttings, etc.) are heated in a sealed chamber to temperatures greater than 200 degrees Celsius by allowing the pressure to increase, but without reaching the critical point of water. At these temperatures, the ability of water to extract organics from solid particulate increases drastically. This paper describes the modeling and experimentation on the use of an acoustic resonant chamber which is part of an amino acid detection instrument called Astrobionibbler [Noell et al. 2014, 2015]. In this instrument we use acoustics to excite a fluid- solid fines mixture in different frequency/Amplitude regimes to accomplish a variety of sample processing tasks. Driving the acoustic resonant chamber at lower frequencies can create circulation patterns in the fluid and mixes the liquid and fines, while driving the chamber at higher frequencies one can agitate the fluid and powder and create a suspension. If one then drives the chamber at high amplitude at resonance heating of the slurry occurs. In the mixing and agitating cell the particle levitation force depends on the relative densities and compressibility’s of the particulate and fluid and on the kinetic and potential energy densities associated with the velocity and pressure fields [Glynne-Jones, Boltryk and Hill 2012] in the cell. When heating, the piezoelectric transducer and chamber is driven at high power in resonance where the solid/fines region is modelled as acoustic transmission line with a large loss component. In this regime, heat is pumped into the solution/fines mixture and rapidly heats the sample. We have modeled the piezoelectric transducer/chamber/ sample using Mason’s equivalent circuit. In order to assess the validity of the model we have built and tested a variety of chambers. This paper describes the experimental results which are in general agreement with theory within the limitations of the modeling.

fluid particle interaction↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗