Search NASA⌕ Search

SEARCH · Search NASA

Results for “Poisson statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A numerical framework for simulating the atmospheric variability of supermicron marine biogenic ice nucleating particles

Abstract. We present a framework for estimating concentrations of episodically elevated high-temperature marine ice nucleating particles (INPs) in the sea surface microlayer and their subsequent emission into the atmospheric boundary layer. These episodic INPs have been observed in multiple ship-based and coastal field campaigns, but the processes controlling their ocean concentrations and transfer to the atmosphere are not yet fully understood. We use a combination of empirical constraints and simulation outputs from an Earth system model to explore different hypotheses for explaining the variability of INP concentrations, and the occurrence of episodic INPs, in the marine atmosphere. In our calculations, we examine the following two proposed oceanic sources of high-temperature INPs: heterotrophic bacteria and marine biopolymer aggregates (MBPAs). Furthermore, we assume that the emission of these INPs is determined by the production of supermicron sea spray aerosol formed from jet drops, with an entrainment probability that is described by Poisson statistics. The concentration of jet drops is derived from the number concentration of supermicron sea spray aerosol calculated from model runs. We then derive the resulting number concentrations of marine high-temperature INPs (at 253 K) in the atmospheric boundary layer and compare their variability to atmospheric observations of INP variability. Specifically, we compare against concentrations of episodically occurring high-temperature INPs observed during field campaigns in the Southern Ocean, the Equatorial Pacific, and the North Atlantic. In this case study, we evaluate our framework at 253 K because reliable observational data at this temperature are available across three different ocean regions, but suitable data are sparse at higher temperatures. We find that heterotrophic bacteria and MBPAs acting as INPs provide only a partial explanation for the observed high INP concentrations. We note, however, that there are still substantial knowledge gaps, particularly concerning the identity of the oceanic INPs contributing most frequently to episodic high-temperature INPs, their specific ice nucleation activity, and the enrichment of their concentrations during the sea–air transfer process. Therefore, targeted measurements investigating the composition of these marine INPs and drivers for their emissions are needed, ideally in combination with modeling studies focused on the potential cloud impacts of these high-temperature INPs.

54 ENVIRONMENTAL SCIENCES↗

the D0 Luminosity Monitor operations and performance

The D0 Luminosity Monitor (LM) plays a crucial role in D0 physics analyses by providing the normalization for many cross section measurements. The detector consists of two sets of 24 scintillator wedges read out with photomultiplier tubes. The detector is located in the forward regions surrounding the beam pipe, covering a pseudo-rapidity range of 2.7 < |{eta}| < 4.4. The LM is sensitive to a large fraction of the total inelastic cross section and measures the luminosity by counting the number of empty proton-antiproton bunch crossings, using Poisson statistics to extract the instantaneous luminosity. The techniques used to convert the measurements made by the LM into the assessed luminosity will be discussed, as well as the performance and operational details of the detector.

43 PARTICLE ACCELERATORS↗

Comparison between S/1 and R/1 tests and damage density vs. fluence (rho(phi)) results for unconditioned and sub-nanosecond laser-conditioned KD2PO4 crystals

We present S/1 and R/1 test results on unconditioned and 355 nm (3{omega}), 500 ps laser conditioned DKDP. We find up to {approx}2.5X improvement in fluence in the S/1 performance after 3{omega}, 500 ps conditioning to 5 J/cm{sup 2}. For the first time, we observe a shift to higher fluences in the R/1 results for DKDP at 3{omega}, 7 ns due to 500 ps laser conditioning. The S/1 results are compared to {rho}({phi}) results previously measured on the same DKDP crystal [1]. A consistent behavior in fluence was found between the S/1 and {rho}({phi}) results for unconditioned and 500 ps conditioned DKDP. We were successful at using Poisson statistics to derive a connection between the S/1 and {rho}({phi}) results that could be tested with our data sets by trying to predict the shape of the {rho}({phi}) curve. The value for the power dependence on fluence of {rho}({phi}) derived from the S/1 data was {approx}11 {+-} 50%. The results presented and discussed here imply a strong correlation between the damage probability (S/1) test and {rho}({phi}). We find a consistent description of the two test types in terms of a power law {rho}({phi}) and that this basic shape held for all cases, i.e. the shape was invariant between unconditioned and conditioned results.

36 MATERIALS SCIENCE↗

UCRLDetermination of the standard deviation on multiplication based on count distributions

The multiplication M of a multiplying object can be determined by analyzing the arrival times of thermal neutrons in detectors such as helium tubes. A source emitting neutrons randomly will lead to neutron inter arrival times obeying Poisson process statistics. By observing how the inter arrival times of detected counts differ from Poisson statistics, one can assess properties of the neutron source such as the source intensity and multiplication. While the method of analyzing the inter arrival times of neutrons using count distributions to determine characteristics of the source has been used for a long time, the treatment of the errors on the determined quantities multiplication M and source strength S have not yet been adequately treated. This object of this report is to assess these errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of the standard deviation on multiplication based on count distributions

The multiplication M of a multiplying object can be determined by analyzing the arrival times of thermal neutrons in detectors such as helium tubes. A source emitting neutrons randomly will lead to neutron inter arrival times obeying Poisson process statistics. By observing how the inter arrival times of detected counts differ from Poisson statistics, one can assess properties of the neutron source such as the source intensity and multiplication.The results of this study show that analyzing the data stream using non-overlapping time gates is an improvement over the current analysis using overlapping time gates. The new method enables us to compute the standard deviation on the multiplication parameter M accurately. Also, this standard deviation on M decreases as the largest time gate is about 10 times the characteristic time constant λ -1 of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical interpretation of the Amerithrax “morph” assay results

In the Amerithrax investigation PCR–based “morph assays” were used to link the anthrax letters with the RMR–1029 flask at USAMRIID. Quantitative data reported for several of these assays are not consistent with Poisson sampling statistics, but instead exhibit “Taylor's Law” behavior where the variance greatly exceeds the mean. A plausible statistical model for this behavior can explain the large number of observed negative and “inconclusive” findings, and implies a high likelihood that a repository sample could contain a “morph” mutant at concentrations well above the nominal detection limit but nonetheless give a negative or inconclusive test result. A Bayesian framework relates the assay results to the probability that a sample actually contains all four morph mutants, even though it tested negative for at least one. The analysis implies that the observed false negative rate actually does not significantly weaken the conclusion that the morph assays correctly excluded all but the stocks derived from RMR–1029 as possible sources of the letter powders, at least when the test results were unambiguous. In conclusion, these findings expand upon and resolve some of the issues cited in recent reviews, and indicate the importance of developing a rigorous statistical framework for interpreting “morph” assay data.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in utilizing event based data structures for neutron scattering experiments

This article strives to expand on existing work to demonstrate advancements in data processing made available using event mode measurements. Most spallation neutron sources in the world have data acquisition systems that provide event recording. The new science that is enabled by utilizing event mode has only begun to be explored. In the past, these studies were difficult to perform because histograms forced dealing with either large chunks of time or a large number of files. With event based data collection, data can be explored and rebinned long after the measurement has completed. This article will review some of the principles of event data and how the method opens up new possibilities for in situ measurements, highlighting techniques that can be used to explore changes in the data. We also demonstrate the statistical basis for determining data quality and address the challenge of determining how long to measure mid-measurement. Lastly, we demonstrate a model independent method of grouping data via hierarchical clustering methods that can be used to improve calibration, reduction, and data exploration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Single atom visibility in STEM optical depth sectioning

The continuing development of aberration correctors for the scanning transmission electron microscope (STEM) offers the possibility of locating single atoms in crystals in 3D via optical depth sectioning. The main factors that determine the feasibility of such an approach are visibility and dose requirements. In this paper, we show how Poisson's statistics can be quantitatively incorporated into STEM image simulations and demonstrate that the 3D location of single cerium atoms in wurtzite-type aluminum nitride is indeed feasible under large-angle illumination conditions with a relatively low dose. We also show that chromatic aberration does not presently represent a limitation provided a cold field emission source is used. Finally, these results suggest efforts into improved aberration corrector designs for larger illumination angles that offer significant potential for 3D structure determination of materials.

36 MATERIALS SCIENCE↗

WIDESPREAD NANOFLARE VARIABILITY DETECTED WITH HINODE/X-RAY TELESCOPE IN A SOLAR ACTIVE REGION

It is generally agreed that small impulsive energy bursts called nanoflares are responsible for at least some of the Sun's hot corona, but whether they are the explanation for most of the multimillion-degree plasma has been a matter of ongoing debate. We present here evidence that nanoflares are widespread in an active region observed by the X-Ray Telescope on board the Hinode mission. The distributions of intensity fluctuations have small but important asymmetries, whether taken from individual pixels, multipixel subregions, or the entire active region. Negative fluctuations (corresponding to reduced intensity) are greater in number but weaker in amplitude, so that the median fluctuation is negative compared to a mean of zero. Using Monte Carlo simulations, we show that only part of this asymmetry can be explained by Poisson photon statistics. The remainder is explainable through a tendency for exponentially decreasing intensity, such as would be expected from a cooling plasma produced from a nanoflare. We suggest that nanoflares are a universal heating process within active regions.

79 ASTRONOMY AND ASTROPHYSICS↗

An Ensemble Approach to Computationally Efficient Radiological Anomaly Detection and Isotope Identification

Radiological source search is a challenging task involving detection and identification of weak sources in a constantly changing radiological background. As of now, many radiological source detection algorithms have been proposed; however, their computational complexity, and hence reliance on power intensive processing units inhibit low-power applications of radiological source search systems. In this work, we introduce the anomaly filter (AF) algorithm; a computationally light, yet effective time-series source detection algorithm based on exponential weighted moving average (EWMA) and Poisson deviance statistics. Then, we demonstrate that the proposed algorithm can be used in ensemble with other more computationally intensive source detection and identification algorithms to achieve both increased detection performance and reduced power consumption. The proposed AF algorithm and the ensemble algorithms were thoroughly benchmarked against several existing source detection and identification algorithms. The results show that the AF algorithm outperforms existing conventional source detection algorithms, and the ensemble approach improves the overall performance of existing source detection and isotope identification algorithms. Furthermore, the AF algorithm and the Non-negative Matrix Factorization approach based source identification (NMF-ID) algorithm were combined and implemented on a singleboard microcontroller and the power consumption was measured. This ensemble algorithm reduced the power consumption of the NMF-ID algorithm almost by a factor of 100, while improving the detection performance of the overall system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of CUORE to Neutrinoless Double-Beta Decay

In this paper, we study the sensitivity of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity are discussed and compared, and the formulas and parameters used in the sensitivity estimates are provided. Assuming a background rate of 10{sup -2} cts/(keV kg y), we find that, after 5 years of live time, CUORE will have a 1 {sigma} sensitivity to the neutrinoless double-beta decay half-life of {caret T{sup 0{nu}}{sub 1/2}}(1{sigma} ) = 1.6x 10{sup 26} y and thus a potential to probe the effective Majorana neutrino mass down to 41-95 meV; the sensitivity at 1.64{sigma} , which corresponds to 90% C.L., will be {caret T{sup 0{nu}}{sub 1/2}(1.64{sigma} }) = 9.5x10{sup 25} y. This range is compared with the claim of observation of neutrinoless double-beta decay in {sup 76}Ge and the preferred range in the neutrino mass parameter space from oscillation results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay

We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assuming a background rate of 10 -2 cts/(keV kg y), we find that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the neutrinoless double-beta decay half-life of T$0v\atop{1/2}$(1θ) = 1.6 \times 10 26 y and thus a potential to probe the effective Majorana neutrino mass down to 40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will be T$0v\atop{1/2}$(1.64θ) = 9.5 \times 10 25 y. This range is compared with the claim of observation of neutrinoless double-beta decay in 76 Ge and the preferred range of the neutrino mass parameter space from oscillation results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Krylov complexity in mixed phase space

We investigate the Krylov complexity of thermofield double states in systems with mixed phase space, uncovering a direct correlation with the Brody distribution, which interpolates between Poisson and Wigner statistics. Our analysis spans two-dimensional random matrix models featuring (I) GOE-Poisson and (II) GUE-Poisson transitions and extends to higher-dimensional cases, including a stringy matrix model (GOE-Poisson) and the mass-deformed SYK model (GUE-Poisson). Krylov complexity consistently emerges as a reliable marker of quantum chaos, displaying a characteristic peak in the chaotic regime that gradually diminishes as the Brody parameter approaches zero, signaling a shift toward integrability. These results establish Krylov complexity as a powerful diagnostic of quantum chaos and highlight its interplay with eigenvalue statistics in mixed phase systems.

chaos & nonlinear dynamics↗

IMFIT: A FAST, FLEXIBLE NEW PROGRAM FOR ASTRONOMICAL IMAGE FITTING

I describe a new, open-source astronomical image-fitting program called IMFIT, specialized for galaxies but potentially useful for other sources, which is fast, flexible, and highly extensible. A key characteristic of the program is an object-oriented design that allows new types of image components (two-dimensional surface-brightness functions) to be easily written and added to the program. Image functions provided with IMFIT include the usual suspects for galaxy decompositions (Sérsic, exponential, Gaussian), along with Core-Sérsic and broken-exponential profiles, elliptical rings, and three components that perform line-of-sight integration through three-dimensional luminosity-density models of disks and rings seen at arbitrary inclinations. Available minimization algorithms include Levenberg-Marquardt, Nelder-Mead simplex, and Differential Evolution, allowing trade-offs between speed and decreased sensitivity to local minima in the fit landscape. Minimization can be done using the standard χ{sup 2} statistic (using either data or model values to estimate per-pixel Gaussian errors, or else user-supplied error images) or Poisson-based maximum-likelihood statistics; the latter approach is particularly appropriate for cases of Poisson data in the low-count regime. I show that fitting low-signal-to-noise ratio galaxy images using χ{sup 2} minimization and individual-pixel Gaussian uncertainties can lead to significant biases in fitted parameter values, which are avoided if a Poisson-based statistic is used; this is true even when Gaussian read noise is present.

79 ASTRONOMY AND ASTROPHYSICS↗

Gaussian Beta Ensembles at High Temperature: Eigenvalue Fluctuations and Bulk Statistics

We study the limiting behavior of Gaussian beta ensembles in the regime where βn=const as n→∞. The results are (1) Gaussian fluctuations for linear statistics of the eigenvalues, and (2) Poisson convergence of the bulk statistics. (2) is an alternative proof of the result by Benaych-Georges and Péché (J Stat Phys 161(3):633–656, 2015) with the explicit form of the intensity measure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Universality of Poisson-driven plasma fluctuations in the Alcator C-Mod scrape-off layer

Large-amplitude, intermittent fluctuations are ubiquitous in the boundary region of magnetically confined plasmas and lead to detrimental plasma-wall interactions in next-generation, high duty cycle fusion power experiments. Using gas puff imaging data time series from the scrape-off layer in the Alcator C-Mod device, it is demonstrated in this work that the large-amplitude fluctuations can be described as a super-position of pulses with a fixed shape and a constant duration. By applying a new deconvolution algorithm on the data time series with a two-sided exponential pulse function, the arrival times and amplitudes of the pulses can be estimated, and the measurement time series can be reconstructed with high accuracy. The pulse amplitudes are shown to follow an exponential distribution. The waiting times between pulses are uncorrelated, their distribution has an exponential tail, and the number of arrivals is a linear function of time. This demonstrates that pulse arrivals follow a homogeneous Poisson process. Identical statistical properties apply to both ohmic and high confinement mode plasmas, clearly demonstrating the universality of the fluctuation statistics in the boundary region of Alcator C-Mod.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signal, noise, and resolution in correlated fluctuations from snapshot small-angle x-ray scattering

It has been suggested that the three-dimensional structure of one particle may be reconstructed using the scattering from many identical, randomly oriented copies ab initio, without modeling or a priori information. This may be possible if these particles are frozen in either space or time, so that the conventional two-dimensional small-angle x-ray scattering (SAXS) distribution contains fluctuations and is no longer isotropic. We consider the magnitude of the correlated fluctuation SAXS (CFSAXS) signal for typical x-ray free-electron laser (XFEL) beam conditions and compare this against the errors derived with the inclusion of Poisson photon counting statistics. The resulting signal-to-noise ratio (SNR) is found to rapidly approach a limit independent of the number of particles contributing to each diffraction pattern, so that the addition of more particles to a ''single-particle-per-shot'' experiment may be of little value, apart from reducing solvent background. When the scattering power is significantly less than one photon per particle per Shannon pixel, the SNR grows in proportion to incident flux. We provide simulations for protein molecules in support of these analytical results, and discuss the effects of solvent background scatter. We consider the SNR dependence on resolution and particle size, and discuss the application of the method to glasses and liquids, and the implications of more powerful XFELs, smaller focused beams, and higher pulse repetition rates for this approach. We find that an accurate CFSAXS measurement may be acquired to subnanometer resolution for protein molecules if a 9-keV beam containing 10{sup 13} photons is focused to a {approx}100-nm spot diameter, provided that the effects of solvent background can be reduced sufficiently.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗