SEARCH · Search NASA
Results for “Pool Fire”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
LASER COMBUSTION DIAGNOSTICS FOR SOOTING FLAMES AND TURBULENT POOL FIRES: CARS AND LII MEASUREMENTS.
Abstract not provided.
Laser-Diagnostic Probling of Radiative Flux Generation in Hydrocarbon Pool Fires.
Abstract not provided.
Validation of Sodium Chemistry (NAC) Package - FY18 Progress.
This report describes the progress on the validation of the development of MELCOR Sodium Chemistry (NAC) package. The primary focus for this report is to ensure that the implementation of the CONTAIN-LMR sodium models into MELCOR is correctly done. Thus, the verification test is to conduct the code-to-code comparison with MELCOR and CONTAIN-LMR. Last year we had reported the development of NAC package which included three sodium models: spray fire, pool fire and atmospheric chemistry. The first 2 models were completed and additional improvement for these two models were done this year to allow upward spray capability and various functional capability for modeling the pool fire experiment better, respectively. This year, the atmospheric chemistry implementation has been progressed to a point for testing in the presence of water vapor (modeled as ideal gas) as a part of the two-condensable option model in the CONTAIN- LMR. The user's guide and reference manual for the NAC package including these improvements are described in a separate document being published as a part of the MELCOR 2.2 release. For this report, we would discuss the experimental validation using the implemented spray fire and pool fire models. A code-to-code comparison with CONTAIN-LMR is described for a spray fire experiment. Note that the atmospheric chemistry model has not fully implemented due to the absence of the two condensable option. Only the chemical reactions between the sodium aerosol and water vapor can be modeled. ACKNOWLEDGEMENTS This work was overseen and managed by Matthew R. Denman (Sandia National Laboratories). In addition, we appreciate that Chris Faucett for developing experimental data and provided the initial input decks as a part of the MELCOR assessment report development for U.S. Nuclear Regulatory Commission's project. This work is supported by the Office of Nuclear Energy of the U.S. Department of Energy work package number AT-17SN170204 and NT-185N05030102.
Fire and Thermal Experiments in Support of the Model Evaluation Protocol for LNG Facility Fires
The motivation for the experiments reported here pertains to the siting of Liquefied Natural Gas (LNG) facilities which requires assessing the potential adverse radiant thermal impacts of accidental fires on the public. The objective is to obtain data on jet fires, pool fires, fireballs, and concrete walls that could serve as thermal barriers for model validation. The fuels tested include ethane, ethylene, propane, and isopentane.
Containment Sodium Chemistry Models in MELCOR.
To meet regulatory needs for sodium fast reactors’ future development, including licensing requirements, Sandia National Laboratories is modernizing MELCOR, a severe accident analysis computer code developed for the U.S. Nuclear Regulatory Commission (NRC). Specifically, Sandia is modernizing MELCOR to include the capability to model sodium reactors. However, Sandia’s modernization effort primarily focuses on the containment response aspects of the sodium reactor accidents. Sandia began modernizing MELCOR in 2013 to allow a sodium coolant, rather than water, for conventional light water reactors. In the past three years, Sandia has been implementing the sodium chemistry containment models in CONTAIN-LMR, a legacy NRC code, into MELCOR. These chemistry models include spray fire, pool fire and atmosphere chemistry models. Only the first two chemistry models have been implemented though it is intended to implement all these models into MELCOR. A new package called “NAC” has been created to manage the sodium chemistry model more efficiently. In 2017 Sandia began validating the implemented models in MELCOR by simulating available experiments. The CONTAIN-LMR sodium models include sodium atmosphere chemistry and sodium-concrete interaction models. This paper presents sodium property models, the implemented models, implementation issues, and a path towards validation against existing experimental data.
Sodium Fire Collaborative Study Progress -- CNWG Fiscal Year 2020
This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year 2020. First, the current sodium pool fire model in MELCOR, which is adapted from CONTAIN-LMR code, is discussed. The associated sodium fire input requirements are also presented. These input requirements are flexible enough to permit further model development via control functions to enhance the current model without modifying the source code. The theoretical pool fire model improvement developed at Sandia is discussed. A control function model has been developed from this improvement. Then, the validation study of the sodium pool fire model in MELCOR carried out by both Sandia and JAEA’s staff is described. To validate this pool fire model with the enhancement, a JAEA sodium pool fire experiment (F7-1 test) is used. The results of the calculation are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for next fiscal year, 2021.
Validation of CONTAIN-LMR code for accident analysis of sodium-cooled fast reactor containments
CONTAIN-LMR 1 is an analytical tool for the containment performance of sodium cooled fast reactors. In this code, the modelling for the sodium fire is included: the oxygen diffusion model for the sodium pool fire, and the liquid droplet model for the sodium spray fire. CONTAIN-LMR is also able to model the interaction of liquid sodium with concrete structure. It may be applicable to different concrete compositions. Testing and validation of these models will help to qualify the simulation results. Three experiments with sodium performed in the FAUNA facility at FZK have been used for the validation of CONTAIN-LMR. For pool fire tests, calculations have been performed with two models. The first model consists of one gas cell representing the volume of the burn compartment. The volume of the second model is subdivided into 32 coupled gas cells. The agreement between calculations and experimental data is acceptable. The detailed pool fire model shows less deviation from experiments. In the spray fire, the direct heating from the sodium burning in the media is dominant. Therefore, single cell modeling is enough to describe the phenomena. Calculation results have reasonable agreement with experimental data. Limitations of the implemented spray model can cause the overestimation of predicted pressure and temperature in the cell atmosphere. The ability of the CONTAIN-LMR to simulate the sodium pool fire accompanied by sodium-concrete reactions was tested using the experimental study of sodium-concrete interactions for construction concrete as well as for shielding concrete. The model provides a reasonably good representation of chemical processes during sodium-concrete interaction. The comparison of time-temperature profiles of sodium and concrete shows, that the model requires modifications for predictions of the test results. (authors)
MELCOR/CONTAIN LMR Implementation Report - FY16 Progress.
This report describes the progress of the CONTAIN - LMR sodium physics and chemistry models to be implemented in MELCOR 2.1. In the past three years , the implementation included the addition of sodium equations of state and sodium properties from two different sources. The first source is based on the previous work done by Idaho National Laboratory by modifying MELCOR to include liquid lithium equation of state as a working fluid to model the nuclear fusion safety research. The second source uses properties generated for the SIMMER code. The implemented modeling has been tested and results are reported in this document. In addition, the CONTAIN - LMR code was derived from an early version of the CONTAIN code, and many physical models that were developed since this early version of CONTAIN are not available in this early code version. Therefore, CONTAIN 2 has been updated with the sodium models in CONTAIN - LMR as CONTAIN2 - LMR, which may be used to provide code-to-code comparison with CONTAIN - LMR and MELCOR when the sodium chemistry models from CONTAIN - LMR have been completed. Both the spray fire and pool fire chemistry routines from CONTAIN - LMR have been integrated into MELCOR 2.1, and debugging and testing are in progress. Because MELCOR only models the equation of state for liquid and gas phases of the coolant, a modeling gap still exists when dealing with experiments or accident conditions that take place when the ambient temperature is below the freezing point of sodium. An alternative method is under investigation to overcome this gap . We are no longer working on the separate branch from the main branch of MELCOR 2.1 since the major modeling of MELCOR 2.1 has been completed. At the current stage, the newly implemented sodium chemistry models will be a part of the main MELCOR release version (MELCOR 2.2). This report will discuss the accomplishments and issues relating to the implementation. Also, we will report on the planned completion of all remaining tasks in the upcoming FY2017, including the atmospheric chemistry model and sodium - concrete interaction model implementation .
Sodium Fire Collaborative Study Progress (CNWG Fiscal Year 2022)
This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year (FY) 2022 and is a continuation of the FY 2021 progress report. We only report the changes made to the current sodium pool fire model in MELCOR. We modified and corrected many control functions to enhance the fraction of oxygen consumed that reacts to form monoxide (FO2) parameter in the current model from the FY2021 report. This year's enhancements relate to better agreement of the suspended aerosol measurement from JAEA's F7 series tests. Staff from Sandia and JAEA conducted the validation studies of the sodium pool fire model in MELCOR. To validate this pool fire model with the latest enhancement, JAEA sodium pool fire experiments (F7-1 and F7-2) were used. The results of the calculation, including the code-to-code comparisons are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for FY 2023.
Sodium Fire Collaborative Study Progress CNWG Fiscal Year 2021
This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year (FY) 2021 and is a continuation of the FY2020 progress report. In this report, we only report the changes made to the current sodium pool fire model in MELCOR. We modified and corrected many control functions to enhance the current model from the FY2020 report. This year’s enhancements relate to better agreement of the suspended aerosol measurement from JAEA’s F7 series tests. Staff from Sandia and JAEA conducted the validation studies of the sodium pool fire model in MELCOR. To validate this pool fire model with the latest enhancement, JAEA sodium pool fire experiments (F7-1 and F7-2) were used. The results of the calculation, including the code-to-code comparisons are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for FY2022.
Sodium Fire Collaborative Study Progress (CNWG FY 2019)
This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year 2019. First, the current sodium pool fire model in MELCOR, which is adapted from CONTAIN-LMR code, is discussed. The associated sodium fire input requirements are also presented. A proposed model improvement developed at Sandia is discussed. Finally, the validation study of the sodium pool fire model in MELCOR carried out by a JAEA's staff is described. To validate this model, a JAEA sodium pool fire experiment (F7-1 test) is used. A preliminary calculation is performed using a modified MELCOR model from a previous experiment simulation. The results of the calculation are discussed as well as suggestions for improvement. Finally, recommendations are made for new MELCOR simulations for next fiscal year, 2020.
Fire Whirl Investigation
A series of experiments were performed with the objective of achieving an extreme thermal environment by creating a fire whirl in an enclosure in facilities at the Thermal Test Complex (TTC) at Sandia National Laboratories. The motivation for the experiments is based on results from previous experiments performed at Sandia in an igloo representing a mock weapon's storage facility. In that test series, a fire whirl developed within the igloo resulting in extremely high heat flux levels. This environment was created with a pool fire of 4.6-m in diameter and was not under controlled, repeatable conditions. The objective of the current tests is to have the ability to create this environment in a repeatable controlled environment at a smaller scale, namely with a pool fire not above 3-m diameter effectively, thereby allowing for repeatable, cost-effective testing. In FY15, six tests were conducted in the Crosswind Test Facility (XTF), using a 1.77 m square pan. In FY16, three tests were conducted in the Fire Laboratory for Accreditation of Modeling by Experiment (FLAME) using a 3-m diameter pan. Both of these test series utilized the same enclosure. In FY17, a single test was performed in XTF using a 2.7 m square pan using a modified enclosure which included a ceiling. All tests used Jet-A as the fuel. The wind speed and gap width of the enclosure were varied for the FY15 XTF tests and the gap width and effect of insulation on the enclosure walls were varied for the FY16 FLAME tests. Fuel regression rates, heat flux, and gas velocity measurements were obtained. The results from the FY15 and FY16 test series indicate that fuel regression rates and peak heat flux levels are a factor of two higher than non-fire whirl pool fires of equivalent diameter. The results from the FY17 test using an enclosure with a ceiling met the objective of the test series by achieving temperatures of nearly 1400°C and heat flux levels of 400 kW/m 2 .
Pipe Overpack Container Fire Testing: Phase II-A
The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to overpressurize and release its inner content. In 2016, Phase II tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with an all-metal (NUCFIL019DS) filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. For the test phase discussed in this report, Phase II-A, the POCs are exposed to a 30-minute pool fire, with similar configurations to those tested in Phase II, except that the POC lids are fitted with a hybrid metal-polyethylene (UT9424S) filter instead. This report will: describe the various tests conducted in Phase II-A, present results from these tests, and discuss implications for the POCs based on the test results.