At least 73 records · Page 4

Nucleate pool boiling: High gravity to reduced gravity; liquid metals to cryogens

Requirements for the proper functioning of equipment and personnel in reduced gravity associated with space platforms and future space station modules introduce unique problems in temperature control; power generation; energy dissipation; the storage, transfer, control and conditioning of fluids; and liquid-vapor separation. The phase change of boiling is significant in all of these. Although both pool and flow boiling would be involved, research results to date include only pool boiling because buoyancy effects are maximized for this case. The effective application of forced convection boiling heat transfer in the microgravity of space will require a well grounded and cogent understanding of the mechanisms involved. Experimental results are presented for pool boiling from a single geometrical configuration, a flat surface, covering a wide range of body forces from a/g = 20 to 1 to a/g = 0 to -1 for a cryogenic liquid, and from a/g = 20 to 1 for water and a liquid metal. Similarities in behavior are noted for these three fluids at the higher gravity levels, and may reasonably be expected to continue at reduced gravity levels.

Merte, Herman, Jr.↗

Unified descriptor for enhanced critical heat flux during pool boiling of hemi-wicking surfaces

Boiling heat transfer is dictated by interfacial phenomena at the three-phase contact line where vapor bubbles form on the surface. Structured surfaces have shown significant enhancement in critical heat flux (CHF) during pool boiling by tailoring interfacial phenomena. This CHF enhancement has been primarily explained by two structural effects: roughness, which extends the contact line length at the bubble base, and wickability, the ability to imbibe liquid through surface structures by capillary pumping. Here, in this work, we show that CHF enhancement on structured surfaces cannot be described by roughness or wickability alone. This result was confirmed using systematically designed micropillar surfaces with controlled roughness and wickability. Further, we performed a scaling analysis and derived a unified descriptor, which represents the combined effects of thin film density and volumetric wicking rate. This unified descriptor shows a reasonable correlation with CHF values with our experiments and literature data. This work provides important insights in understanding the role of surface structures on CHF enhancement, thereby providing guidelines for the systematic design of surface structures for enhanced pool boiling heat transfer.

42 ENGINEERING↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-GPU porting of a phase-change cascaded lattice Boltzmann method for three-dimensional pool boiling simulations

The Lattice Boltzmann method (LBM) has proven effective in simulating phase-change phenomena, such as melting, solidification, evaporation, and boiling. In this work, we develop a highly parallelized multi-GPU implementation of LBM for three-dimensional pool boiling simulations. The code is based on the OpenACC programming model, which enables the code to be deployed efficiently on multi-core CPUs, GPUs, and potentially other accelerators, without the need for architecture-specific rewrites. To support large-scale simulations, the domain is decomposed and distributed across multiple compute nodes using MPI. We demonstrate that the code exhibits excellent scaling properties, with ideal strong-scaling running with up to 256 GPUs on the MareNostrum5 cluster.

97 MATHEMATICS AND COMPUTING↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Decoupling Surface Topography from Gravitational Acceleration in Cryogenic Pool Boiling

Boiling heat transfer is governed by a complex interplay between surface conditions and gravitational acceleration. To isolate the sole effects of gravity, we investigated the pool boiling characteristics of liquid nitrogen on atomically smooth silicon dioxide (SiO 2 ) surfaces under terrestrial (1-g) and reduced gravity (0±0.02 g) conditions achieved via parabolic flight. Our results quantify a drastic reduction in the critical heat flux (CHF) in reduced gravity, decreasing from 16.15 W/cm 2 at 1-g to 5−6 W/cm 2 at μ-g due to the suppression of buoyancy. Conversely, we observed a distinct increase in the heat transfer coefficient (HTC) in the reduced gravity condition prior to CHF. By utilizing a surface with a maximum peak-to-valley height of ≈36.7 nm and low contact angle hysteresis (<10°), we confirm this HTC enhancement is an intrinsic response to the gravitational environment, decoupled from surface-defect-induced nucleation. These findings demonstrate that the influence of surface topography is significantly more prominent in reduced gravity than in terrestrial conditions, providing a critical baseline for rationalizing the design of cryogenic thermal management systems in space and quantum applications.

Liquid nitrogen↗

Critical Heat Flux in Pool Boiling on Metal-Graphite Composite Surfaces

A study is conducted on high heat-flux pool boiling of pentane on micro-configured composite surfaces. The boiling surfaces are copper-graphite (Cu-Gr) and aluminum-graphite (Al-Gr) composites with a fiber volume concentration of 50%. The micro-graphite fibers embedded in the matrix contribute to a substantial enhancement in boiling heat-transfer performance. Correlation equations are obtained for both the isolated and coalesced bubble regimes, utilizing a mathematical model based on a metal-graphite, two-tier configuration with the aid of experimental data. A new model to predict the critical heat flux (CHF) on the composites is proposed to explain the fundamental aspects of the boiling phenomena. Three different factors affecting the CHF are considered in the model. Two of them are expected to become the main agents driving vapor volume detachment under microgravity conditions, using the metal-graphite composite surfaces as the heating surface and using liquids with an unusual Marangoni effect as the working fluid.

Zhang, Nengli↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

Pool boiling from rotating and stationary spheres in liquid nitrogen

Results are presented for a preliminary experiment involving saturated pool boiling at 1 atm from rotating 2 and 3 in. diameter spheres which were immersed in liquid nitrogen (LN2). Additional results are presented for a stationary, 2 inch diameter sphere, quenched in LN2, which were obtained utilizing a more versatile and complete experimental apparatus that will eventually be used for additional rotating sphere experiments. The speed for the rotational tests was varied from 0 to 10,000 rpm. The stationary experiments parametrically varied pressure and subcooling levels from 0 to 600 psig and from 0 to 50 F, respectively. During the rotational tests, a high speed photographic analysis was undertaken to measure the thickness of the vapor film surrounding the sphere. The average Nusselt number over the cooling period was plotted against the rotational Reynolds number. Stationary sphere results included local boiling heat transfer coefficients at different latitudinal locations, for various pressure and subcooling levels.

Cuan, Winston M.↗