Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pool boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

8. Innovative Technologies: Two-Phase Heat Transfer in Water-Based Nanofluids for Nuclear Applications Final Report

Nanofluids are colloidal dispersions of nanoparticles in water. Many studies have reported very significant enhancement (up to 200%) of the Critical Heat Flux (CHF) in pool boiling of nanofluids (You et al. 2003, Vassallo et al. 2004, Bang and Chang 2005, Kim et al. 2006, Kim et al. 2007). These observations have generated considerable interest in nanofluids as potential coolants for more compact and efficient thermal management systems. Potential Light Water Reactor applications include the primary coolant, safety systems and severe accident management strategies, as reported in other papers (Buongiorno et al. 2008 and 2009). However, the situation of interest in reactor applications is often flow boiling, for which no nanofluid data have been reported so far. In this project we investigated the potential of nanofluids to enhance CHF in flow boiling. Subcooled flow boiling heat transfer and CHF experiments were performed with low concentrations of alumina, zinc oxide, and diamond nanoparticles in water (≤ 0.1 % by volume) at atmospheric pressure. It was found that for comparable test conditions the values of the nanofluid and water heat transfer coefficient (HTC) are similar (within ±20%). The HTC increased with mass flux and heat flux for water and nanofluids alike, as expected in flow boiling. The CHF tests were conducted at 0.1 MPa and at three different mass fluxes (1500, 2000, 2500 kg/m2s) under subcooled conditions. The maximum CHF enhancement was 53%, 53% and 38% for alumina, zinc oxide and diamond, respectively, always obtained at the highest mass flux. A post-mortem analysis of the boiling surface reveals that its morphology is altered by deposition of the particles during nanofluids boiling. A confocal-microscopy-based examination of the test section revealed that nanoparticles deposition not only changes the number of micro-cavities on the surface, but also the surface wettability. A simple model was used to estimate the ensuing nucleation site density changes, but no definitive correlation between the nucleation site density and the heat transfer coefficient data could be found. Wettability of the surface was substantially increased for heater coupons boiled in alumina and zinc oxide nanofluids, and such wettability increase seems to correlate reasonably well with the observed marked CHF enhancement for the respective nanofluids. Interpretation of the experimental data was conducted in light of the governing surface parameters (surface area, contact angle, roughness, thermal conductivity) and existing models. It was found that no single parameter could explain the observed HTC or CHF phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Safety [Vol. 16, No. 1, January-February 1975]

Nuclear Safety covers significant developments in the field of nuclear safety. The scope is limited to topics relevant to the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, safety considerations in regard to the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 AEC Working Paper on Population Density Around Nuclear Power-Plant Sites Adapted by J. Ft. Buchanan, 8 Water-Reactor Safety-Research Information Meeting by Wm. B. Cottrell, D. O. Hobson, and G. D. Whitman; ACCIDENT ANALYSIS: 29 Burnout in Boiling Heat Transfer. Part I: Pool-Boiling Systems by A. E. Bergles; PLANT SAFETY FEATURES: 43 Radionuclide Behavior During Normal Operation of Liquid-Metal-Cooled Fast Breeder Reactors. Part 1: Production by C. A. Erdman and A. B. Reynolds; CONSEQUENCES OF EFFLUENT RELEASE: 60 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 1: AEC-Owned Facilities by M. B. Biles and F. E. Coffman, 71 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 2: AEC-Licensed Facilities by L. B. Higginbotham and J. T. Collins; OPERATING EXPERIENCES: 76 Incident at the Lucens Reactor by J. M. Miller, 79 IAEA Symposium on Experience from Operating and Fueling of Nuclear Power Reactors by William A. Pryor, 87 Recent Occurrences at Nuclear Reactors and Their Causes Compiled by William R. Casto, 98 Summary of Operating U. S. Power Reactors as of Nov. 1. 1974, 101 Selected Safety-Related Occurrences Reported in September and October 1974 Compiled by William R. Casto; CURRENT EVENTS: 104 General Administrative Activities Compiled by Wm. B. Cottrell, 110 Action on Power-Reactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 119 Action on Nonreactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 121 Proposed Rule Changes as of Oct. 31, 1974; MISCELLANY: 97 ASTM—Euratom Symposium on Radiation Dosimetry: Developments and Standardization (Announcement), 118 Workshops on In-Pile Filter Testing (Announcement), 119 IAEA Symposium on Radiological Impacts from Releases from Nuclear Facilities into Aquatic Environments (Announcement).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical heat flux impact due to cladding surface condition

This paper demonstrates how the cladding surface condition can impact fuel rod heat transfer and critical heat flux (CHF) performance at Pressurized Water Reactor (PWR) type conditions. The cladding surface that is investigated here is a surface with a crud deposit similar to ones observed in a PWR reactor. Tests are performed in the Westinghouse WALT (Westinghouse Advanced Loop Tester) loop test facility where a single ZIRLO clad electrically heated rod with approximately one-foot length is tested at PWR thermal hydraulic conditions and chemistry. Tests are performed for a normal clean rod surface, an oxide surface and with CRUD deposits to investigate the impact on fuel rod heat transfer and CHF performance. The CRUD deposit is characterized for thickness, chimney size and porosity. Test results are presented for the different cladding surface conditions along with comparisons to evaluations performed in the literature for different surfaces at pool boiling conditions. The results indicate that the WALT loop test facility can produce CHF test results which are repeatable for the same heater rod and for different rods with the same surface condition. CHF test results for a ZIRLO cladding surface with a CRUD deposit near 20 microns typical of PWR deposits show similar CHF performance to clean rod surfaces. A noticeable increase in CHF performance was observed for a ZIRLO cladding surface with a thermal oxide layer based on one CHF measurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental investigation on nucleate boiling heat transfer of low GWP refrigerants over metal-foam enhanced tube bundles

The objective of this work is to develop an enhanced tube bundle to improve the nucleate boiling heat transfer for the application of flooded evaporators. The enhanced tube bundle was made by deploying metal foam around the outer surface of aluminum tubes, which provide higher heat transfer area and nucleation site density. The pool boiling experiments for horizontal tube bundles were conducted in a pressure vessel at difference heat fluxes. The heat transfer performance of bare aluminum tube bundle was compared against the metal-foam enhanced tube bundle using low GWP refrigerant, R-1234yf. The experimental results showed that the heat transfer coefficient of the metal-foam enhanced tube bundle was at least two times higher than that of the bare tube bundle, and the enhancement ratio depended on the heat flux condition.

Yang, Cheng-Min↗

Numerical simulation of flow boiling for organic fluid with high saturation temperature in vertical porous coated tube

A semi-analytical model is developed for the prediction of flow boiling heat transfer inside vertical porous coated tubes. The model assumes that the forced convection and nucleate boiling coexist together in the annular flow regime. We used conservations of mass, momentum, and energy to solve for the liquid film thickness and temperature. The heat flux due to nucleate boiling consists of those inside and outside micro-tunnels. To close the equations, a detailed analysis of various forces acting on the bubble is presented to predict its mean departure diameter. Furthermore, the active nucleation site density of porous layer is determined from the pool boiling correlation by introducing suppression factor. The flow boiling heat transfer coefficients of organic fluid (cumene) with high saturation temperature in a vertical flame-spraying porous coated tube are studied numerically. It is shown that the present model can predict most of the experimental values within ±20%. The numerical results also indicate that the nucleate boiling contribution to the overall heat transfer coefficient decreases from 50% to 15% with vapor quality increasing from 0.1 to 0.5.

42 ENGINEERING↗

Microbubble dynamics and heat transfer in boiling droplets

Dissipating large heat fluxes from a surface is critically important in numerous industrial and natural applications. Boiling based spray cooling and surface texturing are two of the most promising methods being investigated to address this problem. Although our understanding on these topics has significantly improved over past decades, critical gaps remain in the knowledgebase stymieing the realization of their full potential. As an example, while bubble growth in pool boiling have been investigated in detail, comparatively little is known about how the bubbles evolve inside boiling drops. In the present work, we have investigated for the first time, the microbubble dynamics inside water droplets boiling on superhydrophilic textured substrates using high-speed X-ray phase contrast imaging (XRPCI). Our observations show that the transient bubble density variation follows similar characteristics irrespective of the texture spacing at a given surface temperature. For an example microstructure, we found that the number of discrete bubbles on the surface decreases as temperature is increased although their growth rate increases. Here, we observe that bubble growth is highly non-uniform during the lifetime of a drop on the surface. Initially, bubbles grow under diffusion-limited regime, but at later times they grow as ~t 1.45 due to combined effects of coalescence and evaporation. In some conditions, we found that bubbles shrink dramatically af- ter the initial growth spurt presumably due to severe quenching of the surface, and migration of bubbles on the surface. Using the bubble sizes, for the first time we analyzed the heat flux removed by a single bubble and also by all the bubbles at a given time. We find that the highest dissipation through latent- heat component (~600 W/cm 2 ) occurs just in the beginning and thereafter it decreases. We expect that our findings and the analysis would guide further work on the topic and will aid in the overarching goal of engineering surfaces that are more efficient in boiling heat transfer.

42 ENGINEERING↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

Tuning Superhydrophilic Nanostructured Surfaces to Maximize Water Droplet Evaporation Heat Transfer Performance

Spraying water droplets on air fin surfaces is often used to augment the performance of air-cooled Rankine power plant condensers and wet cooling tower heat exchangers for building air-conditioning systems. To get the best performance in such processes, the water droplets delivered to the surface should spread rapidly into an extensive, thin film and evaporate with no liquid leaving the surface due to recoil or splashing. This paper presents predictions of theoretical/computational modeling and results of experimental studies of droplet spreading on thin-layer, nanostructured, superhydrophilic surfaces that exhibit very high wicking rates (wickability) in the porous layer. Analysis of the experimental data in the model framework illuminates the key aspects of the physics of the droplet-spreading process and evaporation heat transfer. This analysis also predicts the dependence of droplet-spreading characteristics on the nanoporous surface morphology and other system parameters. The combined results of this investigation indicate specific key strategies for design and fabrication of surface coatings that will maximize the heat transfer performance for droplet evaporation on heat exchanger surfaces. The implications regarding wickability effects on pool boiling processes are also discussed.

Engineering↗

A unifying criterion of the boiling crisis

Abstract We reveal and justify, both theoretically and experimentally, the existence of a unifying criterion of the boiling crisis. This criterion emerges from an instability in the near-wall interactions of bubbles, which can be described as a percolation process driven by three fundamental boiling parameters: nucleation site density, average bubble footprint radius and product of average bubble growth time and detachment frequency. Our analysis suggests that the boiling crisis occurs on a well-defined critical surface in the multidimensional space of these parameters. Our experiments confirm the existence of this unifying criterion for a wide variety of boiling surface geometries and textures, two boiling regimes (pool and flow boiling) and two fluids (water and liquid nitrogen). This criterion constitutes a simple mechanistic rule to predict the boiling crisis, also providing a guiding principle for designing boiling surfaces that would maximize the nucleate boiling performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calculation of Spent Fuel Pool Time-to-Boil using Polaris/ORIGAMI [Slides]

The goal of this experiment was to calculate time-to-boil (TTB) for a Spent Fuel Pool (SFP). TTB is important for SFP management that represents the amount of time available to address loss of forced cooling. Researchers calculated and compared TTB for two cases using SCALE: SFP containing representative LEU fuel (≤ 5 wt %) and SFP containing representative LEU+ fuel (5 – 8 wt %). There were approximately 2300 fuel assemblies in the SFP for each case. Researchers concluded that the impact of LEU+ core on time-to-boil is very small. At such low cooling times, the impact of increased decay heat is not significant. Decay heat of SFP assemblies is small compared to discharge core decay heat.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancement of Heat Transfer with Pool and Spray Impingement Boiling on Microporous and Nanowire Surface Coatings

The DOE National Renewable Energy Laboratory (NREL) is leading a national effort to develop next-generation cooling technologies for hybrid vehicle electronics. The goal is to reduce the size, weight, and cost of power electronic modules that convert direct current from batteries to alternating current for the motor, and vice versa. Aggressive thermal management techniques help to increase power density and reduce weight and volume, while keeping chip temperatures within acceptable limits. The viability of aggressive cooling schemes such as spray and jet impingement in conjunction with enhanced surfaces is being explored. Here, we present results from a series of experiments with pool and spray boiling on enhanced surfaces, such as a microporous layer of copper and copper nanowires, using HFE-7100 as the working fluid. Spray impingement on the microporous coated surface showed an enhancement of 100%-300% in the heat transfer coefficient at a given wall superheat with respect to spray impingement on a plain surface under similar operating conditions. Critical heat flux also increased by 7%-20%, depending on flow rates.

25 ENERGY STORAGE↗

A knowledge gap analysis for transient CHF prediction within RELAP5-3D

Here we compare several experimental pool and flow boiling critical heat flux experiments with corresponding computational models developed with RELAP5-3D. Encompassed within this paper are several sensitivity analyses for the boiling heat transfer correlations, critical heat flux (CHF) prediction within RELAP5-3D and the thermal properties of the cladding for experiments in the Transient Reactor Test Loop (TRTL) and Transient Reactor Test (TREAT) facilities. The sensitivity analyses were consistent in determining that there is a large contribution from the critical heat flux multiplier which in this application, accounts for the effects of power transient critical heat flux. Comparison to experimental results of both the TREAT CHF-SERTTA experimental campaign and a University of New Mexico (UNM) pool boiling experimental campaign demonstrate both the under-prediction of transient CHF and nucleate boiling heat transfer. To address the gaps in knowledge regarding the transient heating effect for both boiling heat transfer and CHF prediction, we present an experimental test matrix for the TRTL facility that will isolate the power transient effect under PWR relevant operational conditions. The test matrix will incorporate 6 power pulses with a constant energy deposition and a timescale that spans over several orders of magnitude, including a steady state test with an exponential period of 10 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Resolution Measurements Reveal Transient Boiling Phenomena under Exponential Heat Inputs

Transient boiling heat transfer is important to the safety of nuclear reactors. Reactivity insertion accidents (RIA) in a nuclear reactor might result in a power excursion in which the heat generation in the fuel rises exponentially with time. The period of the exponential power excursion depends upon the magnitude of the reactivity insertion. The heat generated within the fuel is transferred to the water coolant which then starts to boil. The reactivity feedbacks caused by the heating (Doppler in the fuel and void in the coolant) represent an important mitigation mechanism for such accidents. The time delay between heat generation in the fuel and its transfer to the coolant is key to determining the outcome of the accident, in particular for experimental reactors using highly enriched fissile fuel with a very low Doppler effect. This time delay depends on conduction heat transfer within the fuel, single-phase convective heat transfer and eventually transient boiling heat transfer in the coolant. Although existing transient boiling databases form a highly valuable source of information, sometimes conclusions from different authors are quantitatively and qualitatively in disagreement with each other. This is likely due to differences in experimental setups and also limitations in the accuracy of diagnostics available in those experiments. In order to clarify these discrepancies and shed light on the mechanisms of transient boiling heat transfer, a new experimental study of both pool and flow boiling under exponential power input were carried out respectively. Exponential power escalation periods from 5 ms to 100 ms, bulk temperatures from saturation to 75 K of subcooling and Reynolds number from 25000 to 60000 have been explored at ambient pressure in both pool and flow boiling conditions. What makes this study unique is the use of synchronized state-of-the-art diagnostics such as IR thermometry and high speed video (HSV) which has improved the accuracy of measured quantities, and has provided a new and unique insights into the transient boiling heat transfer, including detection and modeling of the onset of nucleate boiling, better understanding of the transient boiling process and revelation of a new heat transfer mechanism that leads to higher CHF. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of nano-fluid and surfaces with nano structure on the increase of CHF

Critical heat flux (CHF) has necessitated inconvenient compromises between economy and safety in most industries related to thermal systems. Recent development of nanotechnology has enabled synthesis of nano-sized particles and development of new heat transfer fluids with suspended nano-sized particles, i.e., nanofluids. When nanofluids were used in boiling heat transfer cooling, anomalous increase of CHF was reported. Subsequently, nanoparticle deposition on the boiling surface was revealed to contribute to CHF enhancement. Research on surface characteristics determined that three major characteristics affect CHF: wettability, liquid spreadability and multi-scale geometry. We fabricated artificially modified surfaces with arrays of octagonal micro-posts, or ZnO nanorods, or both, and measured their performance in enhancing CHF. The presence of three major characteristics enhanced CHF most. (author)

42 ENGINEERING↗