Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An instrument combining an electrospray ionization source and a velocity-map imaging spectrometer for studying delayed electron emission of polyanions

An instrument combining an electrospray ionization source and a velocity-map imaging (VMI) spectrometer has been developed in order to study the delayed electron emission of molecular anions and especially of polyanions. It operates at a high repetition rate (kHz) in order to increase the acquisition speed. The VMI spectrometer has been upgraded for nanosecond time resolution by gating the voltages applied on the position-sensitive detector. Kinetic energy release distribution of thermionic emission (without any contribution from direct detachment) can be recorded for well-defined delays after the nanosecond laser excitation. The capability of the instrument is demonstrated by recording photodetachment spectra of the benchmark C{sub 60}{sup −} anion and C{sub 84}{sup 2−} dianion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and characterization of a multiple-coincidence ion-momentum imaging spectrometer

The design and performance of a high-resolution momentum-imaging spectrometer for ions which is optimized for experiments using synchrotron radiation is presented. High collection efficiency is achieved by a focusing electrostatic lens; a long drift tube improves mass resolution and a position-sensitive detector enables measurement of the transverse momentum of ions. The optimisation of the lens for particle momentum measurement at the highest resolution is described. We discuss the overall performance of the spectrometer and present examples demonstrating the momentum resolution for both kinetics and for angular measurements in molecular fragmentation for carbon monoxide and fullerenes. Examples are presented that confirm that complete space-time focussing is possible for a two-field three-dimensional imaging spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fiber-coupled displacement measuring interferometer for determination of the posture of a reflective surface

A fiber-coupled displacement measuring interferometer capable of determining of the posture of a reflective surface of a measuring mirror is proposed. The newly constructed instrument combines fiber-coupled displacement and angular measurement technologies. The proposed interferometer has advantages of both the fiber-coupled and the spatially beam-separated interferometer. A portable dual-position sensitive detector (PSD)-based unit within this proposed interferometer measures the parallelism of the two source beams to guide the fiber-coupling adjustment. The portable dual PSD-based unit measures not only the pitch and yaw of the retro-reflector but also measures the posture of the reflective surface. The experimental results of displacement calibration show that the deviations between the proposed interferometer and a reference one, Agilent 5530, at two different common beam directions are both less than ±35 nm, thus verifying the effectiveness of the beam parallelism measurement. The experimental results of angular calibration show that deviations of pitch and yaw with the auto-collimator (as a reference) are less than ±2 arc sec, thus proving the proposed interferometer’s effectiveness for determination of the posture of a reflective surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study for subcriticality measurement of fuel debris in the Fukushima Daiichi reactor - 14582

Fuel debris defueling in the Fukushima Daiichi reactors is planned. Furthermore, retrieved fuel debris will be packed and stored in casks for a long time. In these processes, from the viewpoint of criticality safety, the subcriticality of the fuel debris should be confirmed. Although there are some subcriticality measurement methods, the applicability of these methods to the fuel debris must be investigated because the elemental composition and shape of the fuel debris are unknown. In this study, we focus on the exponential experiment method which is able to measure a wide range of subcriticality. Basic experiments to validate the methods were carried out using Toshiba Nuclear Critical Assembly (NCA) and {sup 3}He Position Sensitive Detector (PSD). The decay curves of neutron flux distributions were measured by the PSD detector and fitted to a theoretical formula. The elemental compositions and neutron spectrum of the fuel debris have been estimated with a severe accident code and a Monte Carlo code. In the experiment, the neutron spectrum of the fuel debris was simulated in the NCA core. The porosity of the fuel debris was assumed to be 60%, which corresponds to be H/U=7.5 and Volume Ratio=1.5. In order to evaluate the effect of the uncertainty of the compositions on the measured subcriticality, a homogeneous region and a heterogeneous region were configured in an experimental core. These regions consisted of fuel rods with different UO{sub 2} enrichment zone or different gadolinia concentration zone in the axial direction. The effective multiplication factors deduced by the exponential experiment method were a range of 0.94 to 0.98. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of the solid angle and response function of a hemispherical spectrograph with injection lens for Auger electrons emitted from long lived projectile states

We present SIMION 8.1 Monte Carlo type simulations of the response function and detection solid angle for long lived Auger states (lifetime τ ∼ 10{sup −9} − 10{sup −5} s) recorded by a hemispherical spectrograph with injection lens and position sensitive detector used for high resolution Auger spectroscopy of ion beams. Also included in these simulations for the first time are kinematic effects particular to Auger emission from fast moving projectile ions such as line broadening and solid angle limitations allowing for a more accurate and realistic line shape modeling. Our results are found to be in excellent agreement with measured electron line shapes of both long lived 1s2s2p{sup 4}P and prompt Auger projectile states formed by electron capture in collisions of 25.3 MeV F{sup 7+} with H{sub 2} and 12.0 MeV C{sup 4+} with Ne recorded at 0{sup ∘} to the beam direction. These results are important for the accurate evaluation of the 1s2s2p {sup 4}P/{sup 2}P ratio of K-Auger cross sections whose observed non-statistical production by electron capture into He-like ions, recently a field of interesting interpretations, awaits further resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Energy Selective Neutron Imaging at the PULSTAR Reactor

Neutron imaging is complementary to X-ray imaging where both are used to investigate the internal features of objects nondestructively. Historically, it only began three years after discovery of the neutron in 1932, however, neutron radiographs with reasonable quality were first made in the mid-fifties. Conventionally, the image is produced by placing the object between the neutron source and a two-dimensional position sensitive detector. The source commonly has a full energy spectrum (white beam) of thermal or cold neutrons to obtain high intensity in the sample and short exposure time. As a result, all neutron energies contribute to the obtained radiograph. Since the interaction of the neutron with matter is energy dependent, different energies produce different contrast on the radiographic image, hence, additional information about the object can be obtained. Neutron imaging that utilizes a narrow spectrum of energy instead of white beam is called energy selective neutron imaging. Many techniques have been explored to select a narrow band of neutron energy for the use in imaging such as the use velocity selectors, double crystal Monochromators, and time of flight techniques (at pulsed neutron sources). The PULSTAR reactor of North Carolina State University (1 MWth) currently has an operational neutron powder diffractometer (NPD) installed on beam tube no. 4, which was designed for neutron scattering experiments and can provide a monoenergetic beam of neutrons. The neutron energy could be selected by diffraction means using a Si bent perfect crystal as a Monochromator. In this work, an investigation of energy selective neutron imaging at the NPD is discussed in terms of the system performance and the ability of material discrimination on a test sample by observing the contrast variations of the neutron radiographs obtained using different neutron energies. Energy selective neutron imaging experiment was successfully tested at the PULSTAR reactor's NPD. Although, the uniform region is small and the exposure time is long in comparison with the NIF, both facilities exhibit similar spatial resolution which is a very important characteristic for any imaging facility. The contrast variation of neuron radiographs for the test sample obtained at different energies indicated a potential advantage for using energy selective neutron imaging over the white beam. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved neutron-gamma discrimination for a 3 He neutron detector using subspace learning methods

3 He gas based neutron linear-position-sensitive detectors (LPSDs) have been applied for many neutron scattering instruments. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio on the orders of 10 5 -10 6 . The NGD ratios of 3 He detectors need to be improved for even better scientific results from neutron scattering. Digital Signal Processing (DSP) analyses of waveforms were proposed for obtaining better NGD ratios, based on features extracted from rise-time, pulse amplitude, charge integration, a simplified Wiener filter, and the cross-correlation between individual and template waveforms of neutron and gamma events. Fisher linear discriminant analysis (FLDA) and three multivariate analyses (MVAs) of the features were performed. The NGD ratios are improved by about 10 2 -10 3 times compared with the traditional PHA method. Finally, our results indicate the NGD capabilities of 3 He tube detectors can be significantly improved with subspace-learning based methods, which may result in a reduced data-collection time and better data quality for further data reduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A facility for investigation of multiple hadrons at cosmic-ray energies

An experimental arrangement for studying multiple hadrons produced in high-energy hadron-nucleus interactions is under construction at the university of Turku. The method of investigation is based on the detection of hadrons arriving simultaneously at sea level over an area of a few square meters. The apparatus consists of a hadron spectrometer with position-sensitive detectors in connection with a small air shower array. The position resolution using streamer tube detectors will be about 10 mm. Energy spectra of hadrons or groups of simultaneous hadrons produced at primary energies below 10 to the 16th power eV can be measured in the energy range 1 to 2000 GeV.

Valtonen, E.↗

The Electrostatic Levitation Facility at NASA's Marshall Space Flight Center

Containerless processing is an important area of research in materials science. Electrostatic levitation (ESL) represents an emerging technology which permits containerless processing in a vacuum environment. NASA's Marshall Space Flight Center (MSFC) established a levitation facility to provide a critical resource to the microgravity materials science research community to continue and enhance ground-based research in the support of the development of flight experiments during the transition to Space Station. During ESL processing, charged specimens are levitated in the electrostatic field produced by the system's electrodes. Three sets of positioning electrodes represent the heart of the MSFC system. Two dual-axis position sensitive detectors provide input for the PID control-loop computer. Sample position is maintained by adjusting the control voltages for the power supplies of the positioning electrodes. A UV source refreshes the charge on specimens during processing via the photoelectric effect. Lasers permit sample heating independent of positioning. The processing chamber typically operates under vacuum condition approximately = 10(exp -7) Torr. Electrostatic levitation provides a materials science research tool for investigations of refractory solids and melts. Topics of investigation include thermophysical properties, phase equilibria, metastable phase formation, undercooling and nucleation, time-temperature-transformation diagrams and other aspects of materials processing. Current capabilities and recent results of processing studies for metals, alloys and oxides will be reviewed.

Rogers, Jan R.↗

Solar X-ray spectroscopy with a Bent Crystal Spectrometer /BCS/

A high-resolution Bent Crystal Spectrometer (BCS) which provides simultaneous and continuous time coverage of a range of wavelengths is described; its application to spectral studies of solar X-ray emission is discussed. Design of the BCS and its accompanying position-sensitive detector is considered. Calibrations of the crystal curvature, the angle between a crystal reference plane and the collimator axis, and the position response of the position-sensitive proportional counter in determining absolute wavelengths are also mentioned. An active solar region spectrum obtained during an airborne BCS test is compared to wavelength data derived from theory or previous experiments, and excellent agreement is found. Specifications for a BCS system to be used in the Solar Maximum Mission satellite of 1979 are given.

Rapley, C. G.↗

Large-format high resolution microchannel plate detectors for ultraviolet astronomy

This report includes work on two types of two-dimensional position-sensitive detectors that were developed in this lab under this award. We worked to develop and optimize the wire-wound helical delay line detector (HDL) in the first and second years. Some early work on the HDL is contained in a paper included as Appendix A. In the second and third years we developed the concept for, then successfully designed and tested, both a lab prototype, and a flight prototype of the first, crossed delay line detector based on two orthogonal serpentine delay lines (SDL). Some of the work on the SDL is contained in a paper included as Appendix B. Appendix C contains copies of the invention report and record.

Martin, Christopher↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Development of the RAIDS extreme ultraviolet wedge and strip detector

In the next few years the Remote Atmospheric and Ionospheric Detector System (RAIDS) package will be flown on a Tiros spacecraft. The EUV spectrometer experiment contains a position-sensitive detector based on wedge and strip anode technology. A detector design has been implemented in brazed alumina and kovar to provide a rugged bakeable housing and anode. A stack of three 80:1 microchannel plates is operated at 3500-4100 V. to achieve a gain of about 10 to the 7th. The top MCP is to be coated with MgF for increased quantum efficiency in the range of 50-115 nm. A summary of fabrication techniques and detector performance characteristics is presented.

Kayser, D. C.↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

The spacecraft control laboratory experiment optical attitude measurement system

A stereo camera tracking system was developed to provide a near real-time measure of the position and attitude of the Spacecraft COntrol Laboratory Experiment (SCOLE). The SCOLE is a mockup of the shuttle-like vehicle with an attached flexible mast and (simulated) antenna, and was designed to provide a laboratory environment for the verification and testing of control laws for large flexible spacecraft. Actuators and sensors located on the shuttle and antenna sense the states of the spacecraft and allow the position and attitude to be controlled. The stereo camera tracking system which was developed consists of two position sensitive detector cameras which sense the locations of small infrared LEDs attached to the surface of the shuttle. Information on shuttle position and attitude is provided in six degrees-of-freedom. The design of this optical system, calibration, and tracking algorithm are described. The performance of the system is evaluated for yaw only.

Welch, Sharon S.↗

Design and performance of a large area neutron sensitive anger camera

We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3 ) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w (F) values

42 ENGINEERING↗

Gamma-ray imaging with germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. By combining existing position-sensitive detectors with an appropriate code aperture, two-dimensional imaging with 0.2-deg angular resolution becomes practical for a typical balloon experiment. Much finer resolutions are possible with larger separations between detectors and the coded aperture as would be applicable for space-based or lunar-based observatories. Two coaxial germanium detectors divided into five external segments have been fabricated and have undergone extensive performance evaluation and imaging testing in our laboratory. These tests together with detailed Monte Carlo modeling calculations have demonstrated the great promise of this sensor technology for future gamma-ray missions.

Mahoney, W. A.↗