A Non-condensing Thermal Compression Power Generation System

Organic Rankine cycle (ORC) systems have attracted interest for more than three decades due to advantages in operation at lower working temperature, low maintenance requirements, and relative simplicity (fewer components). In theory, these advantages should make ORC technology more economically attractive for the small and medium power scales (10 kW to 10 MW). Unfortunately, the theoretical promise of ORC systems for power generation has been realized at only a relatively small fraction of the potential market. Although there are a number of reasons for the low utilization of ORC technology, the root cause is directly tied to the relatively low heat-to-power conversion efficiency (2 to 7% typically) and high cost of specially designed expander–generator equipment that is up to 60% of total system cost. The resulting high cost of the power produced just does not make economic sense except in very specialized situations where on-site power is needed but unavailable (at any cost) or where local generation costs are well above regional averages. The overarching objective of the work presented here is to break this paradigm by developing and demonstrating a new harmonic adsorption recuperative power cycle (HARP) system that offers 40% more efficient power generation as compared with a standard ORC system and estimated electric power production costs at very competitive rates below $0.10/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Natural Gas Geothermal Combined Cycle Power Plant Analysis

Low temperature geothermal resources, including those associated with oil and gas production, are an underutilized source of low carbon energy. The present work investigates coupling of low-temperature geothermal resources with concentrating solar and/or natural gas energy sources to increase the number of locations at which power generation from low temperature geothermal resources would be technically and economically viable. Stand-alone and hybrid geothermal power cycles are simulated using SimTech IPSEpro process modeling software. Design point strategies for a hybrid power cycle that may operate with either a single heat source or two simultaneous heat input sources are considered. Additionally, off-design power plant operation is investigated to consider the impacts of the heat source availability and ambient temperature variations. The off-design analysis utilizes a modeling tool that predicts power plant performance at each time step as a function of topping cycle heat input (from gas or solar), bottoming cycle heat input (from geothermal), and ambient temperature. Addition of a steam topping cycle to an organic Rankine cycle geothermal power plant provides opportunities to increase the efficiency and power output relative to a stand-alone geothermal power plant. Additionally, use of the waste heat from gas turbine power generation in a geothermal bottoming cycle provides opportunities to increase the amount of power generation associated with each unit of carbon dioxide emitted. This paper will describe the hybrid plant configuration evaluated, discuss the predicted power cycle performance, and compare with stand-alone natural gas and geothermal power generation cases. The power cycle investigated is expected to be applicable for use with conventional hydrothermal resources as well as with geologic thermal energy storage applications and/or enhanced geothermal systems. The steam topping cycle could use a concentrated solar heat source for fully renewable hybrid plant configuration. A plant initially constructed with a natural gas topping cycle heat source could be converted to a solar heat source part way though the power cycle operational life to achieve life cycle carbon emission reductions.

concentrating solar power↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This analysis has 30 distinct scenarios. The scenarios include 14 onshore production basins with their respective extraction technologies, for a total of 27 onshore scenarios. The scenarios also include two offshore production scenarios, Gulf of Mexico (GoM) and offshore Alaska, and an associated gas scenario. The results include a national average based on a production-weighted aggregation of the onshore, offshore, and associated gas scenarios. The life cycle GHG emissions from the United States (U.S.) natural gas supply chain are 19.9 g carbon dioxide equivalents (CO2e)/MJ (with a 95% mean confidence interval of 13.1 to 28.7 g CO2e/MJ). The top contributors to carbon dioxide (CO2) and methane (CH4) emissions are combustion exhaust and other venting from compressor systems. Compressor systems are prevalent in most supply chain stages, so compressor emissions are key emission drivers for life cycle emissions. Emission rates are highly variable across the entire supply chain. The national average CH4 emission rate is 1.24%, with a 95% confidence interval ranging from 0.84% to 1.76%.

Littlefield, James↗

Enabling Coal Technology with Carbon Capture for Future Markets with Flameless Pressurized Oxy-Combustion (FPO)

Future markets for power are expected to require more load following power plants, which reduces output during the night and early morning. This is when the demand for electricity is the lowest, so plants must respond rapidly at any time to peak loads resulting from the variable output of wind and solar power. A coal power plant based on Flameless Pressurized Oxy-combustion (FPO) can go from 5% to 100% of capacity rate in less than 30 minutes in response to fluctuating demand, operating at capacity when power prices are highest. FPO is a proven oxy-combustion technology that was developed to recover energy from low ranking coal, other brown fuels and wastes. ITEA began developing FPO in 2003 on a 5-MWth pilot in Gioia del Colle, Italy, to destroy hazardous industrial waste and as such, design objectives were very high combustion efficiencies and capture of metals in the fuel in the vitreous slag. The technology was subsequently deployed in 2009 at the 15-MWth scale at the Jurong Island petrochemical cluster in Singapore for waste incineration. FPO is an oxy-combustion process whereby oxygen is separated from the air, and it is used in combustion with recirculated flue gas to maintain combustion temperatures at acceptable levels. The resultant flue gas is primarily CO 2 and water, which allows for a relatively simple and cheap CO 2 capture process. This is in contrast to air-combustion systems which require a complex and costly post-combustion capture (PCC) process. Coal is fed to the combustor slurried in water, and the combustor operates at elevated pressure (approximately 12 bar) which improves the overall efficiency and reduces the size and cost of the combustor. Notably, the FPO cycle maintains high efficiency by recovering most of the heat of vaporisation of the contained water. The combustor is designed to coalesce the molten ash particles so that they settle to the chamber walls and drain to the outlet, significantly reducing the particulate content in the exhaust gas and allowing the use of coals with up to 40% alkaline ash content. FPO is a low-emission technology: zero thermal NOx minimises overall NOx; any organic nitrogen is converted to elemental nitrogen (N2). Total organic content (TOC) at combustor exit is hundreds of times lower than for traditional combustion processes, with dioxin and furans close to zero. Work commenced on a DOE funded pilot demonstration project in October 2016 to provide the design for a 50-MWth FPO pilot plant that can fire a wide range of high-to-low rank coals. The project will investigate updating and improving the cycle for power generation with CO 2 capture by incorporating a turbo-expander with a principal steam power island that utilizes a heat recovery steam generator, increasing the overall efficiency of the cycle. A cost study is also performed on the updated FPO design as part of the project. The FPO pilot plant built based on the design will then be demonstrated over a 3-year test program to generate data for the design of a commercial-scale 500 MWth firing module commercial power plant with integral carbon capture and sequestration (CCS), which could start construction in 2025. A discussion of the levelized cost of electricity (LCOE) of various cases are presented, including a comparison of established supercritical with PCC (SCPC) technologies with FPO fitted with CO 2 compression and liquefaction, and FPO ready for carbon capture and sequestration (CCS-ready). This would enable CO 2 capture for use in enhanced oil recovery (EOR) or sequestration when market conditions make it attractive to do so. In addition, a comparison of LCOE of FPO and conventional processes for firing low-ranking coals with high water and ash content will be provided.

01 COAL, LIGNITE, AND PEAT↗

NEAR CRITICAL POINT TESTING AND PERFORMANCE RESULTS OF A SCO2 COMPRESSOR FOR A 10MWE BRAYTON CYCLE

Development and commercial acceptance of sCO2 Brayton cycles for power generation applications are growing rapidly as they offer performance advantages over other cycles. To maximize the cycle performance, the compressors are designed to operate near the critical point of the working fluid. At the critical point the fluid properties change rapidly with variations in inlet conditions. This makes it challenging to both accurately predict the performance and guarantee the operability of the compressor, as the behavior is affected by these slight variations in inlet conditions. A full scale 1st stage main compressor for a 10MWe-Class recompression Brayton cycle was built and tested to validate performance and operability in this unique operating range. The compressor was tested in a laboratory environment with additional instrumentation, beyond what is required by PTC-10, to minimize the uncertainty in the measured performance. Complete constant speed characteristics were collected at multiple supercritical points, operating at constant inlet conditions for each speed line covering a range of compressor inlet densities from 400 to 600 kg/m3. Variations in the compressor stage efficiency and choke margin were observed, and the overall operability and stability of the compressor in response to changes in operating condition were also monitored. The compressor was shown to have excellent performance that closely matched the original design prediction. The performance at various inlet conditions showed minimal change in isentropic head coefficient at the design flow, but did show some variation in efficiency and choke margin across the map. These changes in performance were observed to be minimal, and did not affect the stable operation of the compressor. The results demonstrate that a commercial scale sCO2 compressor can operate near the critical point and achieve the high levels of performance and stability required for power generation applications.

pelton, rob↗

Combustion plasma electrical conductivity model development for oxy-fuel MHD applications

Oxy-combustion can enable efficient CO2 capture from fossil fuel power plants in combined cycle systems; however, air separation is expensive. In order to directly utilize the high gas temperatures associated with oxy-combustion and offset any oxygen separation penalties, a magnetohydrodynamic (MHD) generator has been proposed as a plant topping cycle. Accurately predicting the electrical conductivity of combustion products with the addition of potassium “seed” compound is necessary to evaluate the performance of this modern approach to MHD. In order to make these predictions, improved species collisional cross-section data (momentum transfer cross-section, MTCS) are needed at relevant conditions. A gas electrical conductivity model for use in open-cycle MHD power generation applications is presented, which makes use of updated MTCS data not represented in previous legacy publications. Based on the results of a detailed review and analysis of currently available MTCS data relevant to open-cycle MHD combustion systems, recommendations have been provided for relevant species and a gas temperature range of 1500-3500 K (~0.13-0.3 eV electron energy). Model predictions utilizing updated MTCS data are validated against limited experimental data found in literature for oxy-combustion with potassium seed compound. Model results are presented from a parametric study, which show the effect of combustion conditions and seeding on ionization processes and gas electrical conductivity, highlighting differences between modern oxy-combustion MHD systems and legacy approaches implementing air-fired combustion and high levels of preheat.

20 FOSSIL-FUELED POWER PLANTS↗

Advanced Coal Wind Hybrid: Economic Analysis

Growing concern over climate change is prompting new thinking about the technologies used to generate electricity. In the future, it is possible that new government policies on greenhouse gas emissions may favor electric generation technology options that release zero or low levels of carbon emissions. The Western U.S. has abundant wind and coal resources. In a world with carbon constraints, the future of coal for new electrical generation is likely to depend on the development and successful application of new clean coal technologies with near zero carbon emissions. This scoping study explores the economic and technical feasibility of combining wind farms with advanced coal generation facilities and operating them as a single generation complex in the Western US. The key questions examined are whether an advanced coal-wind hybrid (ACWH) facility provides sufficient advantages through improvements to the utilization of transmission lines and the capability to firm up variable wind generation for delivery to load centers to compete effectively with other supply-side alternatives in terms of project economics and emissions footprint. The study was conducted by an Analysis Team that consists of staff from the Lawrence Berkeley National Laboratory (LBNL), National Energy Technology Laboratory (NETL), National Renewable Energy Laboratory (NREL), and Western Interstate Energy Board (WIEB). We conducted a screening level analysis of the economic competitiveness and technical feasibility of ACWH generation options located in Wyoming that would supply electricity to load centers in California, Arizona or Nevada. Figure ES-1 is a simple stylized representation of the configuration of the ACWH options. The ACWH consists of a 3,000 MW coal gasification combined cycle power plant equipped with carbon capture and sequestration (G+CC+CCS plant), a fuel production or syngas storage facility, and a 1,500 MW wind plant. The ACWH project is connected to load centers by a 3,000 MW transmission line. In the G+CC+CCS plant, coal is gasified into syngas and CO{sub 2} (which is captured). The syngas is burned in the combined cycle plant to produce electricity. The ACWH facility is operated in such a way that the transmission line is always utilized at its full capacity by backing down the combined cycle (CC) power generation units to accommodate wind generation. Operating the ACWH facility in this manner results in a constant power delivery of 3,000 MW to the load centers, in effect firming-up the wind generation at the project site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Water use in the development and operation of geothermal power plants.

Geothermal energy is increasingly recognized for its potential to reduce carbon emissions and U.S. dependence on foreign oil. Energy and environmental analyses are critical to developing a robust set of geothermal energy technologies. This report summarizes what is currently known about the life cycle water requirements of geothermal electric power-generating systems and the water quality of geothermal waters. It is part of a larger effort to compare the life cycle impacts of large-scale geothermal electricity generation with other power generation technologies. The results of the life cycle analysis are summarized in a companion report, Life Cycle Analysis Results of Geothermal Systems in Comparison to Other Power Systems. This report is divided into six chapters. Chapter 1 gives the background of the project and its purpose, which is to inform power plant design and operations. Chapter 2 summarizes the geothermal electricity generation technologies evaluated in this study, which include conventional hydrothermal flash and binary systems, as well as enhanced geothermal systems (EGS) that rely on engineering a productive reservoir where heat exists but water availability or permeability may be limited. Chapter 3 describes the methods and approach to this work and identifies the four power plant scenarios evaluated: a 20-MW EGS plant, a 50-MW EGS plant, a 10-MW binary plant, and a 50-MW flash plant. The two EGS scenarios include hydraulic stimulation activities within the construction stage of the life cycle and assume binary power generation during operations. The EGS and binary scenarios are assumed to be air-cooled power plants, whereas the flash plant is assumed to rely on evaporative cooling. The well field and power plant design for the scenario were based on simulations using DOE's Geothermal Economic Technology Evaluation Model (GETEM). Chapter 4 presents the water requirements for the power plant life cycle for the scenarios evaluated. Geology, reservoir characteristics, and local climate have various effects on elements such as drilling rate, the number of production wells, and production flow rates. Over the life cycle of a geothermal power plant, from construction through 30 years of operation, plant operations is where the vast majority of water consumption occurs. Water consumption refers to the water that is withdrawn from a resource such as a river, lake, or non-geothermal aquifer that is not returned to that resource. For the EGS scenarios, plant operations consume between 0.29 and 0.72 gal/kWh. The binary plant experiences similar operational consumption, at 0.27 gal/kWh. Far less water, just 0.01 gal/kWh, is consumed during operations of the flash plant because geofluid is used for cooling and is not replaced. While the makeup water requirements are far less for a hydrothermal flash plant, the long-term sustainability of the reservoir is less certain due to estimated evaporative losses of 14.5-33% of produced geofluid at operating flash plants. For the hydrothermal flash scenario, the average loss of geofluid due to evaporation, drift, and blowdown is 2.7 gal/kWh. The construction stage requires considerably less water: 0.001 gal/kWh for both the binary and flash plant scenarios and 0.01 gal/kWh for the EGS scenarios. The additional water requirements for the EGS scenarios are caused by a combination of factors, including lower flow rates per well, which increases the total number of wells needed per plant, the assumed well depths, and the hydraulic stimulation required to engineer the reservoir. Water quality results are presented in Chapter 5. The chemical composition of geofluid has important implications for plant operations and the potential environmental impacts of geothermal energy production. An extensive dataset containing more than 53,000 geothermal geochemical data points was compiled and analyzed for general trends and statistics for typical geofluids. Geofluid composition was found to vary significantly both among and within geothermal fields. Seven main chemical constituents were found to account for 95-99% of the dissolved solids in typical geofluids. In order of abundance, they were chloride, sodium, bicarbonate, sulfate, silica, calcium, and potassium. The potential for water and soil contamination from accidents and spills was analyzed by comparing geofluid composition with U.S. drinking water standards. Geofluids were found to present a potential risk to drinking water, if released, due to high concentrations of antimony, arsenic, lead, and mercury. That risk could be mitigated through proper design and engineering controls. The concentration and impact of noncondensible gases (NCG) dissolved in the geofluid was evaluated. The majority of NCG was either nitrogen or carbon dioxide, but a small number of geofluids contain potentially recoverable concentrations of hydrogen or methane.

15 GEOTHERMAL ENERGY↗

Baseline System Costs for 50.0 MW Enhanced Geothermal System -- A Function of: Working Fluid, Technology, and Location, Location, Location

Substantial unexploited opportunity exists for the US, and the world, in Enhanced Geothermal Systems (EGS). As a result of US DOE investment, new drilling technology, new power generation equipment and cycles enable meaningful power production, in a compact and modular fashion; at lower and lower top side EGS working fluid temperatures and in a broader range of geologies and geographies. This cost analysis effort supports the expansion of Enhanced Geothermal Systems (EGS), furthering DOE strategic themes of energy security and sub goal of energy diversity; reducing the Nation's dependence on foreign oil while improving the environment.

15 GEOTHERMAL ENERGY↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Economic Analyiss of "Symbiotic" Light Water Reactor/Fast Burner Reactor Fuel Cycles Proposed as Part of the U.S. Advanced Fuel Cycle Initiative (AFCI)

A spreadsheet-based 'static equilibrium' economic analysis was performed for three nuclear fuel cycle scenarios, each designed for 100 GWe-years of electrical generation annually: (1) a 'once-through' fuel cycle based on 100% LWRs fueled by standard UO2 fuel assemblies with all used fuel destined for geologic repository emplacement, (2) a 'single-tier recycle' scenario involving multiple fast burner reactors (37% of generation) accepting actinides (Pu,Np,Am,Cm) from the reprocessing of used fuel from the uranium-fueled LWR fleet (63% of generation), and (3) a 'two-tier' 'thermal+fast' recycle scenario where co-extracted U,Pu from the reprocessing of used fuel from the uranium-fueled part of the LWR fleet (66% of generation) is recycled once as full-core LWR MOX fuel (8% of generation), with the LWR MOX used fuel being reprocessed and all actinide products from both UO2 and MOX used fuel reprocessing being introduced into the closed fast burner reactor (26% of generation) fuel cycle. The latter two 'closed' fuel cycles, which involve symbiotic use of both thermal and fast reactors, have the advantages of lower natural uranium requirements per kilowatt-hour generated and less geologic repository space per kilowatt-hour as compared to the 'once-through' cycle. The overall fuel cycle cost in terms of $ per megawatt-hr of generation, however, for the closed cycles is 15% (single tier) to 29% (two-tier) higher than for the once-through cycle, based on 'expected values' from an uncertainty analysis using triangular distributions for the unit costs for each required step of the fuel cycle. (The fuel cycle cost does not include the levelized reactor life cycle costs.) Since fuel cycle costs are a relatively small percentage (10 to 20%) of the overall busbar cost (LUEC or 'levelized unit electricity cost') of nuclear power generation, this fuel cycle cost increase should not have a highly deleterious effect on the competitiveness of nuclear power. If the reactor life cycle costs are included in the analysis, with the fast reactors having a higher $/kw(e) capital cost than the LWRs, the overall busbar generation cost ($/MWh) for the closed cycles is approximately 12% higher than for the all-LWR once-through fuel cycle case, again based on the expected values from an uncertainty analysis. It should be noted that such a percentage increase in the cost of nuclear power is much smaller than that expected for fossil fuel electricity generation if CO2 is costed via a carbon tax, cap and trade regimes, or carbon capture and sequestration (CCS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Environmental Impacts From the Installation and Operation of Large-scale Solar Power Plants

Large-scale solar power plants are being developed at a rapid rate, and are setting up to use thousands or millions of acres of land globally. The environmental issues related to the installation and operation phases of such facilities have not, so far, been addressed comprehensively in the literature. Here we identify and appraise 32 impacts from these phases, under the themes of land use intensity, human health and well-being, plant and animal life, geohydrological resources, and climate change. Our appraisals assume that electricity generated by new solar power facilities will displace electricity from traditional U.S. generation technologies. Altogether we find 22 of the considered 32 impacts to be beneficial. Of the remaining 10 impacts, 4 are neutral, and 6 require further research before they can be appraised. None of the impacts are negative relative to traditional power generation. We rank the impacts in terms of priority, and find all the high-priority impacts to be beneficial. In quantitative terms, large-scale solar power plants occupy the same or less land per kW h than coal power plant life cycles. Removal of forests to make space for solar power causes CO{sub 2} emissions as high as 36 g CO{sub 2} kW h{sup -1}, which is a significant contribution to the life cycle CO{sub 2} emissions of solar power, but is still low compared to CO{sub 2} emissions from coal-based electricity that are about 1100 g CO{sub 2} kW h{sup -1}.

01 COAL, LIGNITE, AND PEAT↗

A reactive separation process for pre-combustion CO 2 capture employing oxygen-blown coal gasifier off-gas

In this paper, we present an experimental study of a reactive separation system, consisting of a membrane reactor (MR) and an adsorptive reactor (AR) operating in tandem, with the MR’s reject stream serving as the AR’s feed. We investigates the feasibility of applying this MR-AR system for high-purity H 2 production and simultaneous CO 2 capture via the water gas shift (WGS) reaction in the context of Integrated Gas Combined Cycle (IGCC) power generation employing oxygen-blown gasifier syngas from biomass and coal. We previously studied this MR-AR system for the IGCC process employing air-blown gasifier syngas, for which it demonstrated good performance, attaining high conversion exceeding equilibrium, producing ultra-pure H 2 for power generation, and a CO 2 stream ready for sequestration. In this study, we focus on oxygen-blown gasifier off-gas that contains no N 2 , with composition distinctly different from the air-blown gasifier syngas which has a large N 2 content. We employ a carbon molecular sieve membrane (CMSM), a commercial sour-shift WGS catalyst, and a hydrotalcite (HTC) adsorbent. We carried out experiments to determine membrane performance and to identify promising operating conditions in an IGCC-relevant environment. The CMSM proved robust during a long-term (~344 hr run) experimental run under high temperature and pressure maintaining a high He/N 2 selectivity (~170). Multi-cycle runs were carried out during which the MR-AR system displayed superior performance to that of a PBR, by producing a high purity H 2 product directly usable in power generation. Therefore, the findings from this study demonstrate the ability of the MR-AR system to operate stably for a broad range of gasifier off-gas compositions, and indicate its potential for integration into IGCC plants for power generation with CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This package includes the report, the NETL Natural Gas Model, and appendices that include several Excel workbooks and a python script to provide transparent access to the calculations and resulting data.<p>To access the NETL Natural Gas Lifecycle model, visit https://doi.org/10.18141/2476250.</p><p>To access the 2020 Report Appendices, visit https://doi.org/10.18141/2438472.</p>

03 NATURAL GAS↗

Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile

This analysis expands upon previous life cycle analyses (LCAs) of natural gas systems performed by the National Energy Technology Laboratory (NETL). It provides a complete inventory of emissions to air and water, water consumption, and land use change. These environmental burdens are detailed for all supply chain steps from natural gas production through natural gas distribution. This package includes the report, the NETL Natural Gas Model, and appendices that include several Excel workbooks and a python script to provide transparent access to the calculations and resulting data. This is revision 1 of the 2024 study (published December 17, 2024 and updated on January 24, 2025) and corrects a modeling error in natural gas composition. See the errata on page 2 for more information.

03 NATURAL GAS↗

Retrofitting a Geothermal Plant with Solar and Storage to Increase Power Generation

Solar hybridization using concentrating solar power (CSP) can be an effective approach to augment the power generation and power cycle efficiency of a geothermal power plant with a declining resource. Thermal storage can further increase the dispatchability of a geothermal/solar hybrid system, which is particularly valued for a national grid with high renewable penetration. In this paper, a hybrid plant design with thermal storage is proposed based on the requirements of the Coso geothermal field in China Lake, California. The objective is to increase the power production by 4 MWe. In this system, a portion of the injection brine is recirculated through a heat exchanger with the solar heat transfer fluid, before being mixed with the production well brine. In the solar heating loop the brine should be heated to at least 155 degrees C to increase the net power. The solar field and storage were sized based on solar data for China Lake. Thermal storage is used to store excess power at the high-solar-irradiation hours and generate additional power during the evenings. The solar field size, the type and capacity of thermal storage and the operating temperatures are critical factors in determining the most economic hybrid system. Further investigations are required to optimize the hybrid system and evaluate its economic feasibility.

15 GEOTHERMAL ENERGY↗