Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Telemetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Spatially explicit network analysis reveals multi‐species annual cycle movement patterns of sea ducks

Abstract Conservation of long‐distance migratory species poses unique challenges. Migratory connectivity, that is, the extent to which groupings of individuals at breeding sites are maintained in wintering areas, is frequently used to evaluate population structure and assess use of key habitat areas. However, for species with complex or variable annual cycle movements, this traditional bimodal framework of migratory connectivity may be overly simplistic. Like many other waterfowl, sea ducks often travel to specific pre‐ and post‐breeding sites outside their nesting and wintering areas to prepare for migration by feeding extensively and, in some cases, molting their flight feathers. These additional migrations may play a key role in population structure, but are not included in traditional models of migratory connectivity. Network analysis, which applies graph theory to assess linkages between discrete locations or entities, offers a powerful tool for quantitatively assessing the contributions of different sites used throughout the annual cycle to complex spatial networks. We collected satellite telemetry data on annual cycle movements of 672 individual sea ducks of five species from throughout eastern North America and the Great Lakes. From these data, we constructed a multi‐species network model of migratory patterns and site use over the course of breeding, molting, wintering, and migratory staging. Our results highlight inter‐ and intra‐specific differences in the patterns and complexity of annual cycle movement patterns, including the central importance of staging and molting sites in James Bay, the St. Lawrence River, and southern New England to multi‐species annual cycle habitat linkages, and highlight the value of Long‐tailed Ducks ( Calengula haemalis ) as an umbrella species to represent the movement patterns of multiple sea duck species. We also discuss potential applications of network migration models to conservation prioritization, identification of population units, and integrating different data streams.

54 ENVIRONMENTAL SCIENCES↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Improving underwater localization accuracy with machine learning

Machine learning classification and regression algorithms were applied to calibrate the localization errors of a time-difference-of-arrival (TDOA)-based acoustic sensor array used for tracking salmon passage through a hydroelectric dam on the Snake River, Washington, USA. The locations of stationary and mobile acoustic tags were first tracked using the approximate maximum likelihood algorithm. Next, ensembles of classification trees successfully identified and filtered data points with large localization errors. This prefiltering step allowed the creation of a machine-learned regression model function, which decreased the median distance error by 50% for the stationary tracks and by 34% for the mobile tracks. It also extended the previous range of sub-meter localization accuracy from 100 m to 250 m horizontal distance from the dam face (the receivers). Median distance errors in the depth direction were especially decreased, falling from 0.49 m to 0.04 m in the stationary tracks and from 0.38 m to 0.07 m in the mobile tracks. These methods would have application to the calibration of error in any TDOA-based sensor network with a steady environment and array configuration.

47 OTHER INSTRUMENTATION↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Technical Report Wireless Microsensors System for Monitoring Deep Subsurface Operations

This final technical report describes the main findings of the project Wireless Microsensors System for Monitoring Deep Subsurface Operations (FE0031850). The project was part of the U.S. Department of Energy National Energy Technology Laboratory FOA 1998 program to develop new sensor systems for direct observation of parameters associated with CO2 injection and to provide data collection without being disruptive to operations. The overall DOE program was aimed at developing and validating innovative transformational sensor systems, amenable for integration with autonomous intelligent monitoring systems, that are capable of being deployed within the casing annulus and do not have casing perforation or wires/cables in the annulus for installation, power supply, or data transmission needs. Project accomplishments included 1) design and fabrication of a wireless downhole sensor system to monitor parameters for CO2 storage, 2) field testing of the sensor system in two legacy oil & gas wells, and 3) development of an analysis approach that validates the measurements and demonstrates the application of the technology to depict CO2 movement in the subsurface. The project leveraged new sensor technologies along with specialized wellbore telemetry, deployment, and analysis methods designed to address the challenges and risks related to CO2 storage in the subsurface. Results from field testing were a mixture of successes and challenges. The temperature sensor rings, installation procedures in legacy oil & gas wells, wireless powering demonstration, automated data collection, and material compatibility were successful. The wireless data transfer through cement to the wellhead via the sensor relays was not functional beyond the first relay. Consequently, work in the last year of the project included some additional testing of data transmission through different materials along with modeling and analysis of field data for CO2 monitoring applications. This work suggested there are options like polymer cements and open hole annuli that may allow point-to-point transmission along the borehole. The techno-economic analysis suggests that the sensor system is ~40% less expensive than fiber optic distributed temperature system. Modeling of CO2 storage applications suggests temperature can provide an indicator of CO2 saturation but would be best combined with pressure sensors.

47 OTHER INSTRUMENTATION↗

ACCURATE CHARACTERIZATION OF HIGH-DEGREE MODES USING MDI OBSERVATIONS

We present the first accurate characterization of high-degree modes, derived using the best Michelson Doppler Imager (MDI) full-disk full-resolution data set available. A 90 day long time series of full-disk 2 arcsec pixel{sup -1} resolution Dopplergrams was acquired in 2001, thanks to the high rate telemetry provided by the Deep Space Network. These Dopplergrams were spatially decomposed using our best estimate of the image scale and the known components of MDI's image distortion. A multi-taper power spectrum estimator was used to generate power spectra for all degrees and all azimuthal orders, up to l = 1000. We used a large number of tapers to reduce the realization noise, since at high degrees the individual modes blend into ridges and thus there is no reason to preserve a high spectral resolution. These power spectra were fitted for all degrees and all azimuthal orders, between l = 100 and l = 1000, and for all the orders with substantial amplitude. This fitting generated in excess of 5.2 Multiplication-Sign 10{sup 6} individual estimates of ridge frequencies, line widths, amplitudes, and asymmetries (singlets), corresponding to some 5700 multiplets (l, n). Fitting at high degrees generates ridge characteristics, characteristics that do not correspond to the underlying mode characteristics. We used a sophisticated forward modeling to recover the best possible estimate of the underlying mode characteristics (mode frequencies, as well as line widths, amplitudes, and asymmetries). We describe in detail this modeling and its validation. The modeling has been extensively reviewed and refined, by including an iterative process to improve its input parameters to better match the observations. Also, the contribution of the leakage matrix on the accuracy of the procedure has been carefully assessed. We present the derived set of corrected mode characteristics, which includes not only frequencies, but line widths, asymmetries, and amplitudes. We present and discuss their uncertainties and the precision of the ridge-to-mode correction schemes, through a detailed assessment of the sensitivity of the model to its input set. The precision of the ridge-to-mode correction is indicative of any possible residual systematic biases in the inferred mode characteristics. In our conclusions, we address how to further improve these estimates, and the implications for other data sets, like GONG+ and HMI.

79 ASTRONOMY AND ASTROPHYSICS↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗

Factors affecting powerhouse passage of spring migrant smolts at federally operated hydroelectric dams of the Snake and Columbia rivers

From 2008 to 2018, acoustic telemetry studies were conducted to evaluate dam passage survival of spring migrant Chinook salmon and steelhead smolts at seven of the eight federally operated dams on the lower Snake and Columbia rivers. Data from over 87 000 dam passage events were evaluated using regression modeling to identify the effect of spill operations, environmental conditions, and fish characteristics on powerhouse passage probability. In general, powerhouse passage was positively correlated with discharge, negatively correlated with forebay temperature and fish size, and higher for fish that passed the dam at night and for those that approached from the powerhouse side of the river, suggesting powerhouse passage is largely a function of smolt activity level and swimming ability. As such, spilling large volumes of water to reduce powerhouse passage is likely to be most effective during times of reduced activity and swimming ability (e.g., at night, high flows, and cold temperatures). This information can be used to develop dam- and time-specific spill operations that optimize smolt passage, power generation, and other competing demands, such as adult passage.

60 APPLIED LIFE SCIENCES↗

A Framework to Analyze the Requirements of a Multiport Megawatt-Level Charging Station for Heavy-Duty Electric Vehicles

Widespread adoption of heavy-duty (HD) electric vehicles (EVs) will soon necessitate the use of megawatt (MW)-scale charging stations to charge high-capacity HD EV battery packs. Such a station design needs to anticipate possible station traffic, average and peak power demand, and charging/wait time targets to improve throughput and maximize revenue-generating operations. High-power direct current charging is an attractive candidate for MW-scale charging stations at the time of this study, but there are no precedents for such a station design for HD vehicles. We present a modeling and data analysis framework to elucidate the dependencies of a MW-scale station operation on vehicle traffic data and station design parameters and how that impacts vehicle electrification. This framework integrates an agent-based charging station model with vehicle schedules obtained through real-world vehicle telemetry data analysis to explore the station design and operation space. A case study applies this framework to a Class 8 vehicle telemetry dataset and uses Monte Carlo simulations to explore various design considerations for MW-scale charging stations and EV battery technologies. The results show a direct correlation between optimal charging station placement and major traffic corridors such as cities with ports, e.g., Los Angeles and Oakland. Corresponding parametric sweeps reveal that while good quality of service can be achieved with a mix of 1.2-megawatt and 100-kilowatt chargers, the resultant fast charging time of 35–40 min will need higher charging power to reach parity with refueling times.

33 ADVANCED PROPULSION SYSTEMS↗

ExaDigiT/RAPS

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. RAPS either simulates workloads or replays historical workloads from system telemetry, and is able to predict dynamic energy consumption, as well as interact with the cooling model to predict cooling system behavior. Such a tool can be used together with reinforcement learning algorithms to provide an end-to-end optimization tool for data centers.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗

'Green-in-Three' IT Solutions Protecting Workers and the Environment - 12526

The U.S. Department of Energy (DOE), Environmental Management (EM), DOE Richland Operations Office (RL), Mission Support Alliance (MSA), and Lockheed Martin Services, Inc. (LMSI), Information Technology partnered in an effort to reduce environmental impacts, energy use, and operating costs and improve worker safety through consolidation, centralization, and standardization of Information Technology (IT) assets on the Hanford Site. Green-in-Three is an IT Value strategy, which is moving Hanford from an inefficient, antiquated 20. Century IT architecture to a smart, green, flexible 21. Century IT architecture that delivers information anywhere at any time to Hanford Mission partners. The 'Green-in-three' efforts to date have had a significant impact on meeting and exceeding the overall IT Value Strategy to decrease IT maintenance and delivery costs and move Hanford into a smart, green, and flexible 21. Century IT architecture. Some of the results and impacts are as follows: - Thirteen data centers were reduced to two, freeing up approximately 279 m{sup 2} (3000 ft{sup 2})) of space; - Reduced data center energy use 50%, from 120,000 to 60,000 kW; - Excessed 9 metric tons (10 tons) of server equipment; - Removed and properly disposed of 2871 kg (6,300 lb) lead acid batteries; - Projects saved over $1 M in fiber and copper cable installation through 2011; - Developed or improved partnerships with local, state, and federal agencies, Tribes, and Site contractors; - Increased wireless coverage for improved access to remote areas. Moving forward to 2012, the impact of these accomplishments will be realized in the years to come. IT services will be delivered in days instead of months. Field personnel will have access to information at the point of performance, reducing travel time. Remote monitoring, telemetry, and/or video can be conducted using the wireless network; reducing travel time for field inspections. Emergency personnel have access to critical information at the incident site, saving valuable time. Full deployment of the VoIP technologies will reduce power use by 1,000,000 kWh/yr for telecommunications equipment, driving home the IT Value Strategy of Green-in-Three. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast DR: Controlling Small Loads over the Internet

Current state-of-the-art demand response systems are expensive due to extreme reliability constraints in telemetry, control, and metering. The typical cost of enabling a site for regulation services is between $50k and $80k. These costs are orders of magnitude too high for small loads to participate in high-value grid services. Traditional demand response (DR) schedules events in advance and provides basic on/off control. We developed fast DR measurement and communication technologies, which are scalable cost-effective demand response systems with sufficient reliability for real-time control and monitoring of loads over the internet, and we demonstrated an example system for under $100. We installed FastDR systems for lighting, motor, and thermostat control along with power metering at a total of 10 sites, including 6 commercial buildings and 4 residential buildings. This demonstration addressed the following important methodological questions: 1) Can we reliably control loads simultaneously and with low latency across multiple sites within a specified response time; 2) How reliable is using the internet or 4G cellular network as the mode of control and metering; and 3) Can existing Smart Meters provide data for real-time telemetry services. Testing shows fast DR is capable of control to response in 4 seconds and loads complete transition in seconds to less than one minute depending on load type. We demonstrated 4s regulation services and synchronized load control, and we successfully met specifications for ancillary services across the US. Telemetry via the 4G cellular network demonstrated 94.5% success rate, and residential Internet demonstrated a 98% success rate.

Kiliccote, Sila↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OLCF Summit Supercomputer GPU Snapshots During Double-Bit Errors and Normal Operations

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide double-bit errors using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). The dataset relies on Nvidia XID records internally collected by GPU firmware at the time of failure occurrence, on the reboot-time logs of each Summit node, on node-level job scheduler records collected after each job termination, and on a 1Hz data rate from the baseboard management controllers (BMCs) of each Summit compute node using the OpenBMC event subscription protocol. Technical details can be found in the paper Oles et. al “Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study” ICS’24 (https://doi.org/10.1145/3650200.3656615).

97 MATHEMATICS AND COMPUTING↗

Survival of Juvenile Chinook Salmon during Barge Transport

To mitigate for fish losses related to passage through the Federal Columbia River Power System, an extensive fish transportation program using barges and trucks to move fish around and downstream of dams and reservoirs was implemented in 1981. Population modeling and other analyses to support Pacific salmon recovery efforts have assumed that the survival of juvenile salmonids during the transportation experience was 98%. To estimate survival during barge transport from Lower Granite Dam on the Snake River to a release area downstream of Bonneville Dam, a distance of 470 km, we used a novel adaptation of a release-recapture model with acoustic-tagged yearling Chinook salmon (Oncorhynchus tshawytscha) smolts. A total of 1,494 yearling Chinook salmon were surgically implanted with Juvenile Salmon Acoustic Telemetry System (JSATS) acoustic transmitters and passive integrated transponders (PIT) and divided into three groups. The three tagged groups consisted of; (1) a group which was released into the raceway with the population of fish which were later loaded into transportation barges (R{sub B}), (2) a group which was held in a net-pen suspended within the general barge population until 5-6 h prior to barge evacuation, at which time they were confirmed to be alive and then released into the general barge population (R{sub A}), and (3) to validate a model assumption, a group which was euthanized and released into the barge population 2-8 h prior to barge evacuation (R{sub D}). Six replicates of these groups were loaded onto fish transport barges that departed Lower Granite Dam on the Snake River between 29 April and 13 May, 2010. Acoustic receiver arrays between 70 and 220 km downstream of the barge evacuation site were used to detect tagged fish and served as the basis for estimation of survival within the barge. Tag-life-corrected estimates of reach survival were calculated for barged and control fish in each of the six replicate trials. The ratio of survival from release to Rkm 153 for barged fish relative to control fish provided the estimate of within-barge survival. The replicate survival estimates ranged from 0.9503 (SE = 0.0253) to 1.0003 (SE = 0.0155). The weighted average of the replicate estimates of within-barge survival was computed to be = 0.9833 (SE = 0.0062). This study provides the first documentation that assumed survival of 98% inside barges during yearling Chinook salmon smolt transport appears to be justified. Survival of other species or stocks by barge or for any species/stock by truck remains unknown.

13 HYDRO ENERGY↗

Wave Prediction using X-Band Radar (Final Summary Report)

Model Predictive Control (MPC) is the best controls framework available to wave energy today. It allows for the maximization of energy yield from a WEC system while respecting various constraints and losses in the system. This type of constrained optimization is a critical capability for the techno-economic optimization of WEC devices and is difficult to do effectively with causal controls frameworks. MPC requires a future prediction of wave excitation forces, requiring wave prediction on a future time horizon of up to 30 seconds. The future horizon required is highly dependent on the WEC and PTO type available. To our knowledge no-one has been able to implement MPC on a WEC device at sea, due to the fact that phase-resolved wave-prediction is not a capability that has been sufficiently developed to date. The key objectives of this project are focused on developing “industry-ready” wave prediction technology building blocks that can be applied to a wide range of different wave energy conversion topologies. Our collaborative work with device developers has demonstrated that the level of improvement attainable for any particular device is heavily dependent on the device and PTO topology chosen. The range of annual average power capture improvements is on the order of 10% to over 100%. However, the important aspect is that we can get within about 10% of theoretical upper limits even when considering errors in the wave prediction and more importantly, we can optimize performance while respecting various constraints such as motion amplitude or peak structural loads. The combination of improved performance while limiting structural loads has a net effect of reducing the levelized cost of energy from these emerging technologies and allows us to design control laws that meet an economic optimum. Efforts under a previous project on controls has focused on developing a set of wave-prediction algorithms that work by leveraging a network of wave sensing measurement buoys that are equipped with real-time telemetry. The present work is focusing primarily on using X-band radar to measure the wave-field around the WEC to predict the future excitation forces on the structure and combining the measurements of these different sources to create improvements in the wave-prediction accuracy.

16 TIDAL AND WAVE POWER↗

Acoustic Telemetry Evaluation of Juvenile Salmonid Passage and Survival at John Day Dam, 2011

This report presents survival, behavioral, and fish passage results for tagged yearling Chinook salmon and juvenile steelhead as part of a survival study conducted at John Day Dam during spring 2011. This study was designed to evaluate the passage and survival of yearling Chinook salmon and juvenile steelhead to assist managers in identifying dam operations for compliance testing as stipulated by the 2008 Federal Columbia River Power System Biological Opinion and the 2008 Columbia Basin Fish Accords. Survival estimates were based on a paired-release survival model.

Weiland, Mark A.↗