Quantifying the Power System Resilience of the US Power Grid Through Weather and Power Outage Data Mapping
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This report summarizes the tests and results of a supercapacitor based energy storage system demonstration project performed in collaboration with Capacitech Energy, Orlando Utilities Commission and Sandia National Labs. This project evaluated a 3.6 farad (F), 720 V rated supercapacitor system in a microgrid environment to study three primary use cases: black start, voltage regulation, and load leveling, and successfully demonstrated the performance for the use cases.
Abstract not provided.
Abstract not provided.
Recent episodes of natural disasters have challenged the resilience of power grids. Adequate distribution grid planning that properly captures the risk aversion of the utility system planner is a key factor to increase the flexibility of distribution networks to circumvent these events. In this paper, we propose a methodology to determine the optimal portfolio of investments in lines and storage devices in order to minimize a convex combination between expected value and CVaR of operational costs, including energy not served, while taking into account the multistage nature of the energy storage management within this context. While the expected value of energy not served has been traditionally employed to tackle routine failures, we also minimize the CVaR of energy not served to address high-impact, low-probability (HILP) events. We illustrate the performance of the proposed methodology with a 54-Bus system test case.
The Situational Awareness of Grid Anomalies (SAGA) project built upon foundational power system tools developed at the National Renewable Energy Laboratory (NREL) integrated with an ever-increasing set of Gridmetrics data extracted from the cable television (CATV) broadband network infrastructure while assimilating other time-series geospatial data and information, such as weather and cyber-physical phenomena, to demonstrate a disruptive technology for power system data analytics relying on existing infrastructure. Three research thrusts supported (1) visual analytics, (2) cyber-physical power system simulation, and (3) anomaly detection. SAGA created technology that leverages, couples, and fortifies two vastly different realms - power and broadband - to increase the resiliency of the power grid in the face of increasing cyberattacks and operational challenges related to integrating DERs. The exploration of potential synergies of broadband-enabled grids resulted in identifying a mutually beneficial symbiosis that can increase the resiliency of both power and broadband services. Broadband networks perform better with reliable power and are good at providing real-time measurements that identify where the grid is under attack, is failing, or is weak. Likewise, sensor-starved distribution grids perform better and can be more reliable when their operation is buttressed with observations of broadband-detected anomalies. Future research can explore broadband's contribution to continuing to improve grid resiliency, reliability, and cost-effective operation.
The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.
Power system resilience has become a critical topic in recent years because of the increasing trend of extreme events and the growing integration of intermittent renewable energy sources. To enhance grid resilience against high-impact, low-frequency events, two questions should be answered: how to quantify the resilience of a given grid and how to incorporate the quantification into power system planning, operation, and restoration. Here this paper develops a new set of quantitative metrics with clear physical interpretation to comprehensively evaluate power system resilience. Using microgrids as an example, an event-based corrective scheduling (ECS) model and an online model predictive control (OMPC) model are developed to integrate the proposed quantitative resilience metrics into power system optimization models for resilience enhancement. The ECS model employs extreme event data to investigate the optimal restoration solution and to help microgrid operators prepare to respond to similar events. The OMPC model provides online decision-making support for operators to handle ongoing outages in the most resilient fashion. The effectiveness and superiority of the proposed quantitative resilience metrics and the resilience enhancement models are demonstrated through simulations and comparative studies on an IEEE test feeder and a real distribution feeder in Southern California.
Barriers to the participation of distributed energy resources (DERs) in wholesale electricity markets have limited the use of DERs for power system security and resilience. In September 2020, the Federal Energy Regulatory Commission (FERC) approved an order to reduce these barriers. FERC Order No. 2222 enables the participation of DER aggregators in wholesale electricity markets. DERs include renewable generation and technologies that support the integration of renewable generation by increasing grid flexibility and resilience. Requiring wholesale energy markets to allow DER aggregator participation provides a path for DERs to become competitive in these markets. As the contribution from aggregated DERs continues to increase, the aggregator's role in supporting grid security and resilience will become more critical. This paper reviews work that demonstrates how DER aggregators can provide resilience support through technical capabilities, operational strategies, and secure communication architectures. Socioeconomic influences and impacts of aggregators, including implications for social resilience, are presented. There is no one-size-fits-all approach to enhancing resilience in a power grid that includes a growing cohort of DER aggregators, but there are many options for aggregators to contribute to a more resilient and secure power grid.
In many regions around the world, wildfires have become a growing threat, exacerbated by factors such as climate change, droughts, and urban sprawl. These wildfires often wreak havoc on power infrastructure, leading to extended power outages, which can have devastating consequences for communities, especially in socioeconomically vulnerable areas. Ensuring grid resiliency in the face of these challenges is of paramount importance. One innovative approach to mitigating the impact of wildfires on the power grid is the utilization of hydropower facilities including both powered and non-powered hydro dams. While powered hydro dams along with additional infrastructure like energy storage and solar photovoltaic can provide resilience during wildfire-related outages, non-powered dams, originally constructed for purposes other than electricity generation, also offer a unique opportunity to bolster grid resilience. In this paper, we aim to explore the efficacy of hydro-dams in general to provide resiliency during wildfire-induced outages.
Motivated by decreased cost and climate change concerns, penetration of solar photovoltaic (PV) and battery energy storage has been continually increasing. The variability in solar generation assets has led to many challenges for utilities and researchers. Therefore, there is increasing interest in the area of resilience of the grid and contribution from its assets. This paper describes a proposed framework for evaluating the resilience contribution of solar generation and battery storage. The metric provides a quantifiable adaptive capacity measure with uncertainty for the contribution assets proved to the bulk grid. A case study using long and short-term solar generation, with and without battery storage, demonstrates the framework and provides useful insight to the resilience solar and battery storage assets contribute.
With increasing adverse weather events and disasters, enabling resiliency of the power distribution system (PDS) is becoming increasingly important. Here in this work, resiliency is defined as the systems ability to keep supplying critical loads even with multiple contingencies. Resiliency may depend on: (a) advanced tools to assist operators in situational awareness and decision making with the increasing volume of data generated by the PDS, (b) visualization and ease of interaction with system resources and information, especially during extreme events and resulting human operator stress, and (c) flexible resources and autonomous control. Operators and support engineers need to interact with the system for key information and take action under stress, given the requirement for decisions in a short time. Integrated technological solutions are prevailing steps to support the most appropriate decision during critical times to serve essential loads. In order to meet the required goals, a Real-time Resiliency Monitoring and Operational Decision Support (RT-RMOD) tool have been developed. It supports various functionalities, including real-time monitoring, resilience assessment, and proactive decision support. However, this work makes advanced feature additions to the tool by developing data-enabled resilience management algorithms for (i) outage detection and localization, (ii) Resiliency-metric driven restoration and reconfiguration, and (iii) NLP based digital assistant for operators called DINGO (DIgital assistaNt to Grid Operators) to interact with Advanced Distribution Management System (ADMS) and RT-RMOD. The developed algorithm was validated for multiple cases of weather events using a real-world, off-grid microgrid system modeled in a real-time simulator, sensor data, and software tools.
Smart devices are essential to ensure the stability of the power grid and resilience to intermittent energy production. However, smart devices can also be the target of cyber adversaries that may exploit false data injection attacks (FDIAs) to induce unstable grid conditions. A practical consideration of FDIA mitigation approaches is addressed here: given a finite available budget, for which smart device should cyber-threat mitigation be deployed first? In this work, this question is answered by identifying the so-called most-sensitive devices, i.e., the devices that, if compromised, can let an adversary induce the most serious grid instabilities. The method proposed utilizes an adversarial reinforcement learning (RL) framework to identify the k-mostsensitive smart devices (here, smart inverters). The adversarial agent can tamper with the compromised inverters' active and reactive operating power setup points, with the goal of maximizing voltage deviations. Numerical results show that the proposed RL method finds the optimal attack scenarios for 1-point failure and the near-optimal solution for the 2-point case. Additionally, the proposed RL method achieves an 8.8 speed-up ratio in running time compared to the brute force method for the 2-point case.
Coordinating infrastructure planning for transportation and the power grid is essential for enhanced reliability and resilience during operation and disaster management. This paper presents a two-stage stochastic model to optimize the location of electric vehicle fleet charging stations (FEVCSs) to enhance the resilience of a distribution network. The first stage of this model deals with the decision to place an FEVCS at the most favorable and optimized location, whereas the second stage aims to minimize the weighted sum of the value of lost load in multiple potential scenarios with different faults. Indeed, the second stage is a joint grid restoration scheme with network reconfiguration and microgrid formation using available distributed generators and fleet electric vehicles. The proposed model is tested on a modified IEEE-33 node distribution network and a four-node transportation network. Case studies demonstrate the effectiveness of the proposed model.
Energy storage is becoming indispensable for expanding renewable energy integration, and it is critical to the future low-carbon energy supply. Large-capacity, grid scale energy storage can support the integration of solar and wind power and support grid resilience with the diminishing capacity of baseload fossil power plants. With the development of thermal energy storage (TES) for concentrating solar power systems, standalone TES for grid integration becomes attractive due to the declining renewable generation cost and an increasing need for energy storage. The standalone TES system introduced in this paper can play a big role in the carbon-free energy future with capacity larger than batteries and cost likely lower than other energy storage methods such as pumped storage hydropower and compressed air energy storage, both of which also have geological limitations. To this end, we describe a TES system that uses stable, inexpensive solid particles as a TES media to provide scalable, low cost energy storage. The particle-based TES has the ability to drive various thermal power cycles including conventional steam-Rankine, air Brayton turbine with combined-cycle ability, or the emerging supercritical carbon dioxide Brayton power cycle. This work describes the containment design method including a concrete silo and an internal-insulation layer for the particle-TES system. The economic analysis shows significantly low storage cost when the particle-TES is integrated with Brayton combined-cycle power generation. The paper shows the design approach of the particle-TES system and its economic potential for bulk energy storage. The advantage of the particle-TES system as a promising bulk energy storage method is its ability to economically support dispatchable renewable grid penetration for larger capacity and longer discharging hours than current battery storage technologies.
The interdiction defense (ID) problem solves a defender-attacker-defender model where the defender and attacker share the same set of components to harden and target. Here, we build upon the best response intersection (BRI) algorithm by developing the BRI with suboptimal solutions (BRI-SS) algorithm to solve the ID problem. The BRI-SS algorithm utilizes off-the-shelf optimization solvers that return suboptimal solutions at no additional computation cost. We derive novel cuts from suboptimal solutions, reducing the number of iterations required for the algorithm to converge while maintaining optimality guarantees. We also present a heuristic that utilizes all obtained suboptimal solutions to select the next defense to evaluate at each iteration. We perform computational experiments applied to power grid interdiction on standard test cases. Our results demonstrate that the BRI-SS algorithm consistently outperforms the BRI algorithm across all test cases.
Localized generation, storage, and intelligent power electronics are increasingly being integrated into building. The excess storage, thermal, and generation capacity can be used to develop new markets for ancillary services such as peak reduction, voltage and frequency support, or load flattening. Widespread participation in these markets will make the power grid more resilient. However, widespread participation in these markets will require a simple and intuitive control over the excess capacity by the building occupants. Most importantly for adopting these technologies, participation in these markets should not require sacrificing occupant comfort. Many of the proposed control and optimization technologies for supplying the ancillary services do not explicitly incorporate occupant comfort into their models and when they do, generally utilize a rigid constraint on the indoor air temperature set a priori. This reduces flexibility in using excess thermal capacity. It also cannot take into account uncertainties in local factors that affect thermal comfort such as clothing insulation or relative humidity. In this paper we present and justify some assumptions that simplify the standard predictors of thermal comfort. We also develop a regression model of the thermal comfort that is linear with respect to the indoor air temperature. Next we develop the concept of thermal comfort variation that eliminates the dependence of the thermal comfort on uncertain thermal comfort factors. Then, we present a quadratic program utilizing the thermal comfort variation in both the objective function and as a constraint. Finally, we show the results of a time-of-use cost optimization that utilizes the simplified thermal comfort model.