Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Few-femtosecond time resolution in optically pumped hard X-ray scattering at a free-electron laser

Capturing chemical dynamics in real time is a central goal of ultrafast science, necessitating measurements fast enough to track atomic motion on few-femtosecond timescales with high precision. We present time-resolved hard X-ray scattering that meets these criteria by combining 7 fs full-width at half maximum (FWHM) near-infrared laser pulses with sub10 fs FWHM hard X-ray pulses from a free-electron laser. Using heavy water’s electronic response to strong-field ionization as a benchmark, we achieve a sub-8 fs FWHM instrument response function. These optical pump X-ray probe measurements enable direct observation of chemical dynamics with angstrom spatial and few-fs temporal resolution.

Weckwerth, Eleanor [Stanford University, CA (Unite↗

Improving ProtoDUNE pion cross-section measurements with NuGraph Michel-electron tagging

Understanding hadron-argon interactions is essential for precise neutrino energy reconstruction and final-state interaction modeling in liquid-argon time projection chamber (LArTPC) experiments such as DUNE. In particular, pion absorption and charge-exchange processes constitute significant sources of systematic uncertainty in neutrino oscillation measurements. ProtoDUNE-SP, a large-scale LArTPC prototype operated at the CERN Neutrino Platform and exposed to charged-particle test beams in the few-GeV range, enables direct measurements of these processes. This work focuses on the measurement of differential cross sections for pion absorption and charge exchange using the 2 GeV/c pion beam data from the ProtoDUNE-SP run. A key component of this analysis is the identification of Michel electrons from $\pi \rightarrow \mu \rightarrow e$ decay chains, which helps separate different interaction topologies and improves background rejection. Michel electron identification will also assist in reliably calibrating the electromagnetic response in ProtoDUNE-SP data and for the future DUNE detectors. In this analysis, we apply NuGraph to identify Michel electrons. NuGraph is a graph neural network that models detector hits as nodes connected by spatial and temporal edges for particle and topology classification in LArTPC detectors. We first benchmark NuGraph’s Michel electron classification performance using ICEBERG data, a small-scale LArTPC prototype used for DUNE electronics and reconstruction development, and then transfer the approach to ProtoDUNE-SP. This poster presents the analysis strategy, NuGraph-based classification studies, and discusses how these developments are expected to improve the pion cross-section measurement.

Razafinime, Soamasina Herilala [Cincinnati U.] (OR↗

Facile alignment estimation in carbon nanotube films using image processing

Whether a macroscopic assembly of carbon nanotubes can exhibit the one-dimensional properties expected from individual nanotubes critically depends on how well the nanotubes are aligned inside the assembly. Therefore, a simple and accurate method for assessing the degree of alignment is desired for the rapid characterization of carbon nanotube films and fibers. Here, we present an end-to-end solution for determining the global and local spatial orientation of carbon nanotubes in films within a short amount of time using a fast, precise, and economical approach based on an image processing method applied to scanning electron microscopy images. Further, we first use Laplacian edge enhancement filtering for improving the appearance of edge regions, which is followed by image partitioning into multiple blocks to capture the nanoscale orientation characteristics and total variation-based image decomposition of these image blocks. We then perform a 2D-fast Fourier transform on the image decomposed textural components of these edge-enhanced image blocks to determine the orientation distribution, which is utilized to estimate the 2D nematic order parameter. To show the effectiveness of our method, we corroborated our results against results obtained with other state-of-the-art image processing and experimental techniques.

2D-FFT↗

Clock Synchronization Characterization of the Washington DC Metropolitan Area Quantum Network (DC-QNet)

Quantum networking protocols relying on interference and precise time-of-flight measurements require high-precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. With active electronic stabilization, sub-picosecond time deviation (TDEV) was achieved at integration times between 1 s and 10 5 s over 53 km of deployed fiber. Over the same integration periods, 10-picosecond level TDEV was observed using the White Rabbit-Precision Time Protocol (WR-PTP) over 128 km. Measurement methods are described to understand the sources of environmental fluctuations on clock synchronization towards the development of in-situ compensation methods. Path delay gradients, chromatic dispersion, polarization drift, and optical power variations all contributed to clock synchronization errors. The results from this study will inform future work in the development of link noise management methods essential for enabling experimental research in developing practical quantum networking protocols.

PIKTime↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Electronic spectroscopy and ionization potentials for YbOH and YbOCH 3

The polyatomic molecules YbOH and YbOCH 3 have been recognized as being of potential value for spectroscopic experiments that explore charge-parity and time reversal symmetry violation effects. These measurements require very high precision, which, in turn, will necessitate that the molecules be manipulated at ultra-cold temperatures. Both YbOH and YbOCH 3 have electronic transitions that appear suitable for laser cooling ($\tilde{A}$ 2 Π 1/2 -$\tilde{X}$ 2 Σ + and $\tilde{A}$2E 1/2 -$\tilde{X}$ 2 A 1 , respectively) but the currently available spectroscopic data is not sufficient to determine the extent to which population leaks may compromise the optical cooling processes. A further complication is that the quantum states of interest for these measurements will need to be selectively populated. The $\tilde{A}$-$\tilde{X}$ band systems of both YbOH and YbOCH 3 show evidence of vibronic perturbations, such that there are unassigned vibronic features at energies that are just above the origin bands. Here, in the present study we have recorded spectra for the $\tilde{A}$ 2 Π 1/2 -$\tilde{X}$ 2 Σ + transition of jet-cooled YbOD to facilitate the vibronic assignments. In addition, spectra for the $\tilde{B}$ 2 Σ + - $\tilde{X}$ 2 Σ + transition of YbOH were recorded, establishing the origin band at 20473.8 cm -1 . Previously, the reaction of Yb with CH 3 OH has been used to generate gas-phase YbOCH 3 . As this reaction also yields YbOH, there have been complications in spectroscopic studies of YbOCH 3 due to overlap of the $\tilde{A} -\tilde{X}$ band systems. To identify specific regions of overlap, resonantly enhanced two-photon ionization spectra were recorded using mass-resolved detection of the YbOH + and YbOCH 3 + ions. These data confirmed the overlap of vibronic bands near 17640 and 17680 cm -1 . Two-photon ionization spectroscopy also provided accurate ionization energies of IE(YbOH)=45788(10) and IE(YbOCH 3 )=45283(10) cm -1 . The IE for YbOH is relevant to problems encountered in previous attempts to determine the bond dissociation energy of YbOH + .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Picosecond Clock Synchronization Across A 7-Node Metropolitan Scale Quantum Network

Quantum networking protocols relying on interference and precise time-of-flight measurements require high precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. The first technique called active electronic stabilization (ELSTAB), was able to achieve sub-picosecond time deviation (TDEV) at integration times between 1 s and 105s over multiple different fiber lengths of both underground and aerial deployed fiber. The second technique, White Rabbit-Precision Time Protocol (WR-PTP), was able to achieve 10-picosecond TDEV’s over similar fiber lengths at comparable integration times. Environmental fluctuations affected the stability of clock synchronization over deployed fiber. These fluctuations resulted in path delay gradients, chromatic dispersion, polarization drift, and optical power variations. The results from this study will inform future work in the development of compensation methods essential for enabling experimental research in developing practical quantum networking protocols.

synchronization↗

Stochastic GW -GPU: Rapid Quasi-Particle Energies for Molecules beyond 10,000 Atoms

StochasticGW is a code for computing accurate quasi-particle (QP) energies of molecules and material systems in the GW approximation. StochasticGW utilizes the stochastic Resolution of the Identity (sROI) technique to enable a massively parallel implementation with computational costs that scale semilinearly with system size, allowing the method to access systems with tens of thousands of electrons. Here, we introduce a new implementation, StochasticGW-GPU, for which the main bottleneck steps have been ported to GPUs and give substantial performance improvements over previous versions of the code. We showcase the new code by computing band gaps of hydrogenated silicon clusters (Si x H y ) containing up to 10,001 atoms and 35,144 electrons, and we obtain individual QP energies with a statistical precision of better than ±0.03 eV with times-to-solution of less than 1 h.

Thomas, Phillip S. [Lawrence Berkeley National Lab↗

Attosecond intra-valence band dynamics and resonant-photoemission delays in W(110)

Time-resolved photoelectron spectroscopy with attosecond precision provides new insights into the photoelectric effect and gives information about the timing of photoemission from different electronic states within the electronic band structure of solids. Electron transport, scattering phenomena and electron-electron correlation effects can be observed on attosecond time scales by timing photoemission from valence band states against that from core states. However, accessing intraband effects was so far particularly challenging due to the simultaneous requirements on energy, momentum and time resolution. Here we report on an experiment utilizing intracavity generated attosecond pulse trains to meet these demands at high flux and high photon energies to measure intraband delays between sp- and d- band states in the valence band photoemission from tungsten and investigate final-state effects in resonant photoemission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision cosmological constraints on atomic dark matter

Abstract Atomic dark matter is a simple but highly theoretically motivated possibility for an interacting dark sector that could constitute some or all of dark matter. We perform a comprehensive study of precision cosmological observables on minimal atomic dark matter, exploring for the first time the full parameter space of dark QED coupling and dark electron and proton masses (α D ,$$ {m}_{e_D} $$ m e D ,$$ {m}_{p_D} $$ m p D ) as well as the two cosmological parameters of aDM mass fractionf D and temperature ratioξat time of SM recombination. We also show how aDM can accommodate the (H 0 , S 8 ) tension from late-time measurements, leading to a better fit than ΛCDM or ΛCDM + dark radiation. Furthermore, including late-time measurements leads to closed contours of preferredξand dark hydrogen binding energy. The dark proton mass is seemingly unconstrained. Our results serve as an important new jumping-off point for future precision studies of atomic dark matter at non-linear and smaller scales.

Physics↗

Low cost automated precise time measurement system

The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

Alpert, A.↗

ELECTRON SHOWER RECONSTRUCTION IN THE ICARUS EXPERIMENT

This dissertation presents a study in the field of neutrino physics. Neutrinos are fundamental particles that are electrically neutral and have extremely small mass, allowing them to traverse matter with very little interaction. Because of this property, neutrinos are exceptionally difficult to detect. Nevertheless, understanding their behavior is essential for addressing fundamental questions about the origin of the Universe and the properties of matter. This work focuses on the reconstruction of electron showers produced by interactions of electron neutrinos (𝜈𝑒) in the ICARUS experiment, located at the Fermi National Accelerator Laboratory in the United States. ICARUS employs a liquid argon time projection chamber detector, which is capable of recording with high precision the tracks left by particles produced in neutrino interactions. The main objective of this research is to improve the reconstruction algorithms and techniques used to identify and characterize these electron showers, enhancing metrics such as completeness, defined as the fraction of correctly reconstructed signals, and purity, which quantifies how much of the reconstructed signal truly belongs to the candidate event. These improvements are crucial for reducing false positives and increasing the accuracy of electron photon discrimination. Consequently, this work directly contributes to improved neutrino oscillation analyses and to a deeper understanding of neutrino properties.

Salmoria, Gabrieli [Parana Tech. Fed. U., Toledo]↗

First measurements with the CMS DAQ and Timing Hub prototype-1

The DAQ and Timing Hub is an ATCA hub board designed for the Phase-2 upgrade of the CMS experiment. In addition to providing high-speed Ethernet connectivity to all back-end boards, it forms the bridge between the sub-detector electronics and the central DAQ, timing, and trigger control systems. One important requirement is the distribution of several high-precision, phase-stable, and LHC synchronous clock signals for use by the timing detectors. The current paper presents first measurements performed on the initial prototype, with a focus on clock quality. It is demonstrated that the current design provides adequate clock quality to satisfy the requirements of the Phase-2 CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lepton-Nucleus Scattering Measurements for Neutrino Interactions and Oscillations

Currently running and forthcoming precision neutrino oscillation experiments aim to unambiguously determine the neutrino mass ordering, the charge-parity violating phase in the lepton sector and the possible existence of physics Beyond the Standard Model. To have an understanding of all the effects necessary for the success of these experiments, lepton-nucleus interactions must be modeled in unprecedented detail. With this thesis, expertise in both neutrino and electron cross-section modeling and analysis was leveraged in order to make fundamental and critical improvements to our understanding of these interactions. The outlined work takes a significant step towards this high-precision measurement era with three complementary approaches. Cross sections are reported using neutrino data sets from the MicroBooNE liquid argon time projection chamber detector at Fermi National Laboratory, as well as electron scattering data from the CLAS detector at Thomas Jefferson National Laboratory. Furthermore, the modeling development of the commonly used GENIE event generator is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lepton-Nucleus Scattering Measurements for Neutrino Interactions and Oscillations

Currently running and forthcoming precision neutrino oscillation experiments aim to unambiguously determine the neutrino mass ordering, the charge-parity violating phase in the lepton sector and the possible existence of physics Beyond the Standard Model. To have an understanding of all the effects necessary for the success of these experiments, lepton-nucleus interactions must be modeled in unprecedented detail. With this thesis, expertise in both neutrino and electron cross-section modeling and analysis was leveraged in order to make fundamental and critical improvements to our understanding of these interactions. The outlined work takes a significant step towards this high-precision measurement era with three complementary approaches. Cross sections are reported using neutrino data sets from the MicroBooNE liquid argon time projection chamber detector at Fermi National Laboratory, as well as electron scattering data from the CLAS detector at Thomas Jefferson National Laboratory. Furthermore, the modeling development of the commonly used GENIE event generator is presented.

Papadopoulou, Afroditi↗

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗