Search NASA⌕ Search

SEARCH · Search NASA

Results for “Preheating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ceramic applications in the advanced Stirling automotive engine

The requirements of the ideal Stirling cycle, as well as basic types of practical engines are described. Advantages, disadvantages, and problem areas of these Stirling engines are discussed. The potential for ceramic components is also considered. Currently ceramics are used in only two areas, the air preheater and insulating tiles between the burner and the heater head. For the advanced Stirling engine to achieve high efficiency and low cost, the principal components are expected to be made from ceramic materials, including the heater head, air preheater, regenerator, the burner and the power piston. Supporting research and technology programs for ceramic component development are briefly described.

Tomazic, W. A.↗

Single-family-residence solar heating--Carlsbad, New Mexico

Solar-heating and hot-water system includes 408 square feet of flat-plate air collectors, rock storage bin, energy transport system, air-to-water heat exchanger, controls, and hot-water preheat tank. Hot-air oil furnace supplies auxiliary space heating, and electricity powers air-handler blower and hot water preheat pump. For 12 month period, system provided 43 percent of space-heating and 53 percent of hot-water energy; net energy savings were 23.072 million Btu.

Source record↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.

Source record↗

Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

Source record↗

Effect of off-design operation of MHD generators on NO/x/ chemical kinetics

The purpose of this study is to provide a capability for determining the chemical kinetic behavior of one family of pollutants, the nitrogen oxides, in the flow of a coal-fired MHD generator facility. The method used in the study allows the prediction of the nonequilibrium concentration of the minor NO(x) species in a flow otherwise assumed in equilibrium. Consideration is given to the effect of preheat, stoichiometry, and oxygen enrichment of the NO(x) concentration. The effect of preheat and stoichiometry is found to have a significant influence on the NO(x) concentration at the exit of the radiant boiler.

Simmons, G. A.↗

Performance calculations for 1000 MWe MHD/steam power plants

The effects of MHD generator operating conditions and constraints on the performance of MHD/steam power plants are investigated. Power plants using high temperature combustion air preheat (2500 F) and plants using intermediate temperature preheat (1100 F) with oxygen enrichment are considered. Variations of these two types of power plants are compared on the basis of fixed total electrical output (1000 MWe). Results are presented to show the effects of generator plant length and level of oxygen enrichment on the plant thermodynamic efficiency and on the required generator mass flow rate. Factors affecting the optimum levels of oxygen enrichment are analyzed. It is shown that oxygen enrichment can reduce magnet stored energy requirement.

Pian, C. C. P.↗

Surface chemistry and friction behavior of the silicon carbide (0001) surface at temperatures to 1500 deg C

X-ray photoelectron and Auger electron spectroscopy analyses and friction studies were conducted with a silicon carbide (0001) surface in contact with iron at various temperatures to 1200 or 1500 C in a vacuum of 10 to the minus 8th power Pa. The results indicate that there is a significant temperature influence on both the surface chemistry and friction properties of silicon carbide. The principal contaminant of adsorbed amorphous carbon on the silicon carbide surface in the as received state is removed by simply heating to 400 C. Above 400 C, graphite and carbide type carbine are the primary species on the silicon carbide surface, in addition to silicon. The coefficients of friction of polycrystalline iron sliding against a single crystal silicon carbide (0001) surface were high at temperatures to 800 C. Similar coefficients of friction were obtained at room temperature after the silicon carbide was preheated at various temperatures up 800 C. When the friction experiments were conducted above 800 C or when the specimens were preheated to above 800 C, the coefficients of friction were dramatically lower. At 800 C the silicon and carbide type carbon are at a maximum intensity in the XPS spectra. With increasing temperature above 800 C, the concentration of the graphite increases rapidly on the surface, whereas those of the carbide type carbon and silicon decrease rapidly.

Miyoshi, K.↗

Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

Source record↗

An assessment of gas-side fouling in cement plants

The cement industry is the most energy-intensive industry in the United States in terms of energy cost as a percentage of the total product cost. An assessment of gas-side fouling in cement plants with special emphasis on heat recovery applications is provided. In the present context, fouling is defined as the buildup of scale on a heat-transfer surface which retards the transfer of heat and includes the related problems of erosion and corrosion. Exhaust gases in the cement industry which are suitable for heat recovery range in temperature from about 100 to 1300 K, are generally dusty, may be highly abrasive, and are often heavily laden with alkalies, sulfates, and chlorides. Particulates in the exhaust streams range in size from molecular to about 100 micrometers in diameter and come from both the raw feed as well as the ash in the coal which is the primary fuel used in the cement industry. The major types of heat-transfer equipment used in the cement industry include preheaters, gas-to-air heat exchangers, waste heat boilers, and clinker coolers. At the present time, the trend in this country is toward suspension preheater systems, in which the raw feed is heated by direct contact with the hot kiln exit gases, and away from waste heat boilers as the principal method of heat recovery. The most important gas-side fouling mechanisms in the cement industry are those due to particulate, chemical reaction, and corrosion fouling.

Marner, W. J.↗

Autothermal reforming of aliphatic and aromatic hydrocarbon liquids

Results are presented from a study of the autothermal reforming of paraffins and aromatics over nickel catalysts. The trials were performed to examine the carbon products that appear when steam is passed over hydrocarbon liquids to form H2-rich gases, i.e., the autothermal process (ATR). Attention was given to n-hexane, n-tetradecane, benzene, and benzene solutions of naphthalene with reactant preheat to 1000-1150 F. The carbon-formation limit was sought as a function of the steam-to-carbon and oxygen to carbon molar ratios at constant pressure and the preheat temperatures. The catalyst bed was examined after each trial to identify the locations and types of carbon formed using SEM, thermal gravimetric analysis, and X ray diffraction techniques. The hydrocarbon fuels each had a separate temperature and reaction profile, as well as carbon formation characteristics. No carbon formation was observed in the upper layer of the reactor bed, while both gas phase and surface-grown deposits were present in the lower part. The results are concluded of use in the study of No. 2 fuel oil for ATR feedstock.

Flytzani-Stephanopoulos, M.↗

New perspectives for advanced automobile diesel engines

Computer simulation results are presented for advanced automobile diesel engine performance. Four critical factors for performance enhancement were identified: (1) part load preheating and exhaust gas energy recovery, (2) fast heat release combustion process, (3) reduction in friction, and (4) air handling system efficiency. Four different technology levels were considered in the analysis. Simulation results are compared in terms of brake specific fuel consumption and vehicle fuel economy in km/liter (miles per gallon). Major critical performance sensitivity areas are: (1) combustion process, (2) expander and compressor efficiency, and (3) part load preheating and compound system. When compared to the state of the art direct injection, cooled, automobile diesel engine, the advanced adiabatic compound engine concept showed the unique potential of doubling the fuel economy. Other important performance criteria such as acceleration, emissions, reliability, durability and multifuel capability are comparable to or better than current passenger car diesel engines.

Tozzi, L.↗

Microstructure of magnetic reconnection in earth's magnetotail

The structure of heated electron reconnection events associated with magnetic substorm events in the earth's magnetotail is examined using IMP 8 spacecraft and ground-based magnetometer, plasma analyzer and spectroscopic data. Plasma, magnetic field and energetic particle data for five events are presented. Reconnection is shown to occur in two phases: preheating and heating. In preheating, lasting about 5 min, a strong tailward plasma flow appears and ends with electron heating. A 1-2 min heating phase starts with electron heating and ends with plasma sheet drop out and/or decay of the electron temperature to pre-event levels. The heating pulse is always connected with a Bx reversal at 30 earth radii tailward, where the reconnection occurs.

Bieber, J. W.↗

Failure during thermal cycling of plasma-sprayed thermal barrier coatings

The thermal cycling behavior of plasma-sprayed ZrO2-12 wt pct Y2O3 coatings was studied. Coatings were produced with and without bond coats of Ni-Cr-Al-Zr and in some cases the substrates were heated to above the optimum temperature prior to spraying. The coatings (attached to the substrate) were thermal cycled to 1200 C and their cracking behavior was followed by acoustic emission (AE) techniques. It was possible to examine the failure mechanisms by statistical analysis of the AE data and to evaluate the influence of preheating and bond coating. It is shown that the AE spectrum changes when a bond coat is used because of the presence of microcracks which, in turn, dissipate energy and improve the coating integrity. The preheating effect is reflected by a decrease in the peak count rate and an increase in the temperature at which AE activity is initiated.

Berndt, C. C.↗

Energy release topology in a multiple-loop solar flare

The temporal and spatial structures of the UV and X-ray emissions and the magnetic field configuration in the November 12, 1980 flare observed from SMM have been studied. The UV observations were done in the O V and Fe XXI lines with a spatial resolution of 10 arcsec. The observations show that the impulsive UV bursts, and also the hard X-ray bursts by their temporal correlation with the impulsive O V emission, occurred in small localized kernels. By comparing the O V, Fe XXI, and X-ray raster images of the flare with the magnetogram, these emission kernels were identified as footpoints of interacting magnetic flux loops. The temporal evolution of the O V/Fe XXI emission shows that there was considerable preheating in the flare plasma some 8-9 minutes prior to the onset of the main hard X-ray bursts. The results are interpreted as indicating that the primary flare energy release occurred in a highly sheared multiloop structure, which lies along a magnetic neutral line. By either beam particle propagation or convective motion, flare energy is transported via a common footpoint to another loop which brightened later. The preheating of the flare plasma is shown to create a more favorable environment for energetic particle acceleration which resulted in the main impulsive hard X-ray bursts.

Cheng, C.-C.↗

Solar flare precursors

Recent progress in the study of flare precursors and onset is reviewed. New theoretical results on filament formation and erution are presented, including especially the dynamical effects of magnetic fields. Ample evidence is found that energetic processes are already at work in the onset phase, a few minutes before the rapid rise of the hard-radiation impulse. In particular, the prevalence of soft and hard X-ray preheating (to less than 100 million K) is detailed, along with a connection to the launch of coronal mass ejections. A possible interpretation of the empirical time profiles near onset is that 'preheating' signifies that the flare has slowly started, and the transition to the impulsive stage then represents a change of phase in the flare-instability process. Finally, the problem of the interpretation of microwave preflare data is delineated.

Van Hoven, G.↗

Evaluation of flammability for cable-like polymers

A new test method is developed for the flammability of insulated electric cables as well as polymers formed in the cables. The rate of downward flame spread along the polymer surface is measured by a technique in which the flame is stopped at a particular position by winding up the cable at the same speed as the flame spreading rate, with external preheating by an electric furnace having oxidative gas flow. The polymer burns continuously without change of flame condition and the rate is obtained from the winding speed of the cable. A flame spread equation relates the flame spreading rate (V) of the cable-like polymer to O concentration (Yo) and the atmosphere, the preheating temperature, and the pyrolysis temperature for polymer burning. Plotting log V vs. log Yo for experimental results allows evaluation of the flammability of polymers, with discrimination between the effects of O concentration, heating temperature, and specimen shape. Results with various types of PVC electrical cable indicated the validity of the method. Application of the method to the cables in groups showed a flame retardation behavior different from the case of a single cable, in a atmosphere of high O concentration.

Mikado, Tuneo↗

High-resolution heat-transfer-coefficient maps applicable to compound-curve surfaces using liquid crystals in a transient wind tunnel

Tests were performed in a transient heat transfer tunnel in which the model under test was preheated prior to allowing room temperature air to be suddenly drawn over the model. The resulting movement of isothermal contours on the model is revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record is obtained of a temperature and time data pair for all points on the model during a single test. Experiments on a duct model are reported in which the model was preheated using a hot air stream. A manner in which initial model temperature nonuniformities could be taken into account was investigated. The duct model was also tested with a steady-state measurement technique and results were compared with the transient measurements, but recognizing that differences existed between the upstream thermal boundary conditions. The steady-state and transient measurements were shown to be consistent with predicted values. The main advantage of this transient heat transfer technique using liquid crystals is that since the test model need not be actively heated, high-resolution measurements on surfaces with complex shapes may be obtained.

Jones, T. V.↗

High-resolution heat-transfer-coefficient maps applicable to compound-curve surfaces using liquid crystals in a transient wind tunnel

Tests were performed in a transient heat transfer tunnel in which the model under test was preheated prior to allowing room temperature air to be suddenly drawn over the model. The resulting movement of isothermal contours on the model is revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record is obtained of a temperature and time data pair for all points on the model during a single test. Experiments on a duct model are reported in which the model was preheated using a hot air stream. A manner in which initial model temperature nonuniformities could be taken into account was investigated. The duct model was also tested with a steady-state measurement technique and results were compared with the transient measurements, but recognizing that differences existed between the upstream thermal boundary conditions. The steady-state and transient measurements were shown to be consistent with predicted values. The main advantage of this transient heat transfer technique using liquid crystals is that since the test model need not be actively heated, high-resolution measurements on surfaces with complex shapes may be obtained.

Jones, Terry V.↗