Enhancement of operational Flexibility of Power Plants Using IN740

Headers are crucial components within diverse industries, especially in the energy sector, as they enable the efficient transfer of fluids. The selection of materials for headers is determined by their specific applications; for example, Grade 91 and Grade 92 steels are commonly utilized. In our research, we recommend the adoption of INCONEL alloy 740 due to its exceptional robustness and heat-resistant characteristics. One critical parameter in header systems is the heat transfer coefficient, which directly influences the efficiency of heat exchange processes and can thereby impact the structural integrity of the headers. This coefficient is closely linked with factors such as the Nusselt number, which is influenced by fluid flow characteristics and thermal properties. The flow direction within headers, whether unidirectional or multidirectional—significantly affects the overall dynamics of heat transfer. This research focuses on exploring the behavior of headers, a specific pipeline system component, using ANSYS simulation software. The study aims to predict heat transfer and mechanical behavior within headers under various conditions through steady-state and transient simulations (parts 1 and 2 of the report). Key parameters such as heat transfer coefficient, velocity, and temperature are examined with the goal of optimizing header design. Part 3 of the report addresses the critical yet underexplored relationship between pressure drop and heat transfer coefficients in the transient flow regime within headers, specifically focusing on smooth horizontal circular tubes. Limited experimental work has been conducted in this area, prompting the need for comprehensive analysis. By leveraging machine learning techniques, this research aims to establish a correlation between pressure drop and heat transfer across various flow conditions, including laminar, transient, quasi-turbulent, and turbulent regimes. The data utilized for this analysis were meticulously gathered from existing literature, capturing simultaneous measurements of pressure drops and heat transfer. Part 4: In the context of power plants, header pipes are essential components that significantly influence system performance by facilitating the collection and distribution of steam. This report highlights the critical role of header pipes in enhancing reliability, efficiency, and overall power plant performance. A key aspect of this investigation is shape optimization, which aims to maximize performance while minimizing material usage. By focusing on shape optimization, this research contributes to improved efficiency and a reduced environmental footprint for power plant installations. The methodology developed in this study emphasizes optimizing header shapes to decrease reliance on expensive alloy materials and lower maintenance costs. Furthermore, a case study was conducted using a header from an operational power plant to validate the proposed optimization techniques. Finally, part 5 addresses the challenges associated with flexible operations in boiler systems, the study outlines several strategies for enhancing the durability and reliability of steam headers. Key approaches include material selection, which involves utilizing advanced materials with superior high-temperature properties and enhanced fatigue resistance to extend the lifespan of steam headers. Design modifications are also recommended, focusing on implementing changes that mitigate thermal stress and cyclic loading to reduce the likelihood of failures under varying operating conditions. Additionally, the study emphasizes the importance of regular inspection and monitoring by establishing rigorous protocols to detect early signs of damage, allowing for timely maintenance and minimizing the risks of catastrophic failures. Furthermore, operational guidelines are developed to minimize the frequency and severity of thermal transients, ensuring stable and efficient operations. Collectively, these strategies provide a robust framework for overcoming the unique challenges posed by flexible operation in boiler systems, ultimately contributing to improved reliability and performance in power plant operations. Through this comprehensive approach, the study not only enhances the understanding of pressure drop and heat transfer relationships but also promotes advancements in design and operation that will benefit the entire power generation industry.

01 COAL, LIGNITE, AND PEAT↗

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improvement of two-phase closure models in CTF using Bayesian inference

Under the Consortium for Advanced Simulation of Light Water Reactors (CASL) program, extensive capabilities have been developed in CTF to analyze light-water reactors (LWRs) for normal operating conditions, departure from nucleate boiling (DNB), and system transients. However, further improvements are required in the modeling and simulation of boiling water reactors (BWRs), which is a focus of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this work, CTF validation results were used to optimize selected modeling coefficients by calibrating to experimental data using a Bayesian inference approach. Here, calibration studies were conducted to improve (vapor) void fraction prediction without worsening the two-phase pressure drop prediction, as well as to improve the two-phase pressure drop prediction. Calibration was performed for interfacial drag and wall shear models. Surrogates were developed to alleviate the computational expense required for sampling the parameter space using Markov chain Monte Carlo (MCMC). An assessment performed with calibrated models demonstrated an improvement of CTF in its prediction of key parameters such as void fraction and two-phase pressure drop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modelling a compressible packed bed flow-through washing and deacetylation reactor for corn stover pretreatment

The deacetylation process is a key step in the lignocellulosic biomass pretreatment process that currently is done in batch reactors. A flow-through diffuser type reactor is a promising approach to make the process more efficient and economically favorable. A washing step before deacetylation can further reduce chemical usage and increase the process efficiency. However, the highly compacted biomass particles can cause significant pressure-drop for fluid flow through the bed, which in the worst case can cause self-enhancing pressure-drop leading to reactor blocking. Detailed understanding of the fundamentals of flow through a compressible packed bed is necessary to scale up the washing and deacetylation process. This work closely examines the classical Kozeny Carman equation and proposes modifications to accurately predict the pressure-drop at different compaction states. Here, a compressible packed bed model is further developed based on the interaction between solid mechanics and fluid dynamics. Experimental measurements of water flow through a packed bed of corn stover show good agreement with the developed model. Corn stover washing process scale up simulations show that smaller reactor diameter, higher friction lining material, lower process throughput, and higher process temperature is favorable in stabilizing the bed from extensive compression when the bed height is fixed.

09 BIOMASS FUELS↗

Cesium Removal and Hydraulic Performance Comparisons of CST Ion Exchange Media Batches in Support of the Tank Closure Cesium Removal Project - 20522

Three batches of Crystalline Silicotitanate (CST) ion exchange media have been evaluated for cesium removal efficiency from a Savannah River Site (SRS) High Level Waste (HLW) supernate simulant in support of the Tank Closure Cesium Removal (TCCR) Project, which involves at-tank column waste treatment. Results will be utilized to select the CST media batch to be added to the next TCCR unit columns. Two of the CST media samples were recent production batches and the third was an archived batch studied extensively at SRS nearly two decades ago. The archived CST batch had a significantly smaller average particle diameter than more recent batches. Small-scale (∼23 mL), side-by-side column tests were conducted at 35 deg. C with each of the CST batches using the same simulant at flow rates near 1.2 mL/min (3.0-3.4 CST bed volumes/hr). The cesium ion exchange column performance results were lower than expected for all three CST batches, but the data indicated that 30% more simulant volume and 40% more equivalent CST bed volumes of solution can be processed with the older CST batch prior to reaching the 50% cesium breakthrough point than can be processed with the newer CST batches. Hydraulic evaluations of the CST columns were also conducted in simulant at 24 deg. C to determine the impact of the different particle size distributions and associated bed porosities on frictional pressure drop under dynamic flow conditions. Higher differential pressure drops were observed with the archived CST batch relative to recent production batches, due to the smaller particle size distribution and the packing characteristics of the archived batch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Modeling a Water-Cooled Printed Circuit Heat Exchanger Condensing CO2 for use in SCO2 Cycle System Optimization Studies

This work describes a one-dimensional model of a water-cooled printed circuit heat exchanger (PCHE) condensing supercritical CO2. The model is developed for use in cycle optimization studies (e.g., minimizing levelized cost of electricity) as either the main heat rejection cooler and/or a compressor intercooler for recompression closed Brayton supercritical CO2 power cycles. Sensitivity and case studies are used to illustrate the impact of important model parameters, and this includes allowing for independent variation of zig-zag channel wave angles on the CO2 and water side. Results show that for a given CO2 design pressure (and thus saturation temperature), the PCHE design inlet water temperature has a significant impact on the PCHE size. Results also demonstrate that if wave angles are the same on the CO2 and water side, the water side pressure drop will have more influence on determining the optimum PCHE mass than the CO2 side pressure drop. Reducing the water side wave angle to near straight channel flow offers a more compact design for a similar water side pressure drop (and pump power requirement). Cases are also shown for further increasing the compactness and how the PCHE mass is affected along with water pump power.

Liese, Eric↗

Modeling Flow in a Microreactor Core: From High-Fidelity CFD to Subchannel Analysis

The accurate prediction of pressure drop in tightly packed, low–Reynolds number (Re) bare rod bundles is essential for the thermal-hydraulic design of the Microreactor Applications Research Validation and EvaLuation (MARVEL) reactor and other microreactor concepts. However, existing friction factor correlations, particularly the upgraded Cheng-Todreas (UCTD) correlation, have limited validation for the small pitch-to-diameter ratios (P/Ds) and transitional flow conditions characteristic of these systems. In this work, we perform high-fidelity large-eddy simulations (LESs) of both an infinite bare rod bundle and a finite bare 37-pin scalloped rod bundle across the range 1000≤ 𝑅𝑒 ≤5500. The simulations reveal strong gap vortex–driven transitional behavior and indicate that the UCTD may underpredict the friction factor by up to 28% at 𝑃/𝐷 = 1.05. Using the LES-calculated pressure drops, we formulate a new friction factor correlation that follows the Cheng-Todreas functional form but is calibrated for low-Re and tightly packed geometries representative of a MARVEL-like reactor. The correlation is implemented in the MOOSE (Multiphysics Object-Oriented Simulation Environment) subchannel module and compared against both the LES and UCTD predictions. Across all subchannel types, the proposed model reduces the streamwise velocity differences from as high as 44% (UCTD) to below 9%, and decreases the pressure gradient differences from 13% to 25% (UCTD) to 0.7% to 7% relative to the LES results. These results suggest that the new correlation has the potential to improve the pressure drop and flow field predictions for such geometries, highlighting the importance of high-fidelity simulations in supporting microreactor thermal-hydraulic model development and motivating future pressure drop experiments for compact rod bundles to further validate these findings.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid–Liquid Microfluidic Flows for Ultrafast 5-Hydroxymethyl Furfural Extraction

We study the effects of liquid–liquid flow patterns on the extraction of 5-hydroxymethyl furfural from the aqueous phase into an organic phase (methyl isobutyl ketone, ethyl acetate, and 2-pentanol) at ultrashort residence times of 0.2–20 s in a coiled capillary microchannel. Slug, droplet, slug-droplet, dispersed, parallel, annular, and irregular two-phase flow patterns are generated. We evaluate the extraction efficiency and the volumetric mass transfer coefficient via experiments and computational fluid dynamics (CFD). The CFD predictions are in quantitative agreement with the experimental data. The convective and diffusive contributions to the mass transfer of different flow patterns are analyzed. For all solvent pairs, the extraction efficiency varies irregularly with increasing flow rate due to changes in the mass transfer mechanism caused by a transition between flow regimes. Overall, we demonstrate >90% extraction efficiencies with high volumetric mass transfer coefficients ranging from 0.006 to 2.17 s–1. Furthermore, a merit index is defined to assess the trade-off between the fast mass transfer and the pressure drop in biphasic microchannels. In general, the mass transfer rate increases significantly at high flow rates at the expense of a high-pressure drop. Furthermore, the ethyl acetate/water irregular flow pattern is optimal due to a large throughput, extraction efficiency, and mass transfer coefficient, with a minimal pressure drop.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Industrial scale mesofluidic particle separation

Here we explore the potential of a mesofluidic separator that fits within industrial piping and is designed to remove large aspherical particles out of an abrasive slurry at fast flow rates. Mesofluidic separators have recently demonstrated separation of spherical particles at flow rates of ~1 gallon/min (gpm) (6.3.10 -5 m 3 /s). Yet, the performance of these separators at flow rates achievable within industrial piping have not been explored. Here we evaluate the permeate flowrate fraction, large particle mass fraction, and pressure drop from approximately 35-100 gpm (2.2.10-3-6.3.10-3 m 3 /s) in a three inch tube using an abrasive and modestly non-spherical slurry. Faster flow rates may be achieved with larger pumps and larger diameters. We find the permeate fraction and pressure drop both increase with flow rate, though the pressure drop remains modest. Only two feet of inserts removed 97.6±2.1% of large particles for conditions tested. Separation was demonstrated in both vertical and horizontal orientations with the horizontal orientation benefiting marginally from gravitational settling.