Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigation of Convection and Pressure Treatment with Splitting Techniques

Treatment of convective and pressure fluxes in the Euler and Navier-Stokes equations using splitting formulas for convective velocity and pressure is investigated. Two schemes - controlled variation scheme (CVS) and advection upstream splitting method (AUSM) - are explored for their accuracy in resolving sharp gradients in flows involving moving or reflecting shock waves as well as a one-dimensional combusting flow with a strong heat release source term. For two-dimensional compressible flow computations, these two schemes are implemented in one of the pressure-based algorithms, whose very basis is the separate treatment of convective and pressure fluxes. For the convective fluxes in the momentum equations as well as the estimation of mass fluxes in the pressure correction equation (which is derived from the momentum and continuity equations) of the present algorithm, both first- and second-order (with minmod limiter) flux estimations are employed. Some issues resulting from the conventional use in pressure-based methods of a staggered grid, for the location of velocity components and pressure, are also addressed. Using the second-order fluxes, both CVS and AUSM type schemes exhibit sharp resolution. Overall, the combination of upwinding and splitting for the convective and pressure fluxes separately exhibits robust performance for a variety of flows and is particularly amenable for adoption in pressure-based methods.

Thakur, Siddharth↗

Pressure-Sensor Assembly Technique

Nielsen Engineering & Research (NEAR) recently developed an ultrathin data acquisition system for use in turbomachinery testing at NASA Glenn Research Center. This system integrates a microelectromechanical- systems- (MEMS-) based absolute pressure sensor [0 to 50 psia (0 to 345 kPa)], temperature sensor, signal-conditioning application-specific integrated circuit (ASIC), microprocessor, and digital memory into a package which is roughly 2.8 in. (7.1 cm) long by 0.75 in. (1.9 cm) wide. Each of these components is flip-chip attached to a thin, flexible circuit board and subsequently ground and polished to achieve a total system thickness of 0.006 in. (0.15 mm). Because this instrument is so thin, it can be quickly adhered to any surface of interest where data can be collected without disrupting the flow being investigated. One issue in the development of the ultrathin data acquisition system was how to attach the MEMS pressure sensor to the circuit board in a manner which allowed the sensor s diaphragm to communicate with the ambient fluid while providing enough support for the chip to survive the grinding and polishing operations. The technique, developed by NEAR and Jabil Technology Services Group (San Jose, CA), is described below. In the approach developed, the sensor is attached to the specially designed circuit board, see Figure 1, using a modified flip-chip technique. The circular diaphragm on the left side of the sensor is used to actively measure the ambient pressure, while the diaphragm on the right is used to compensate for changes in output due to temperature variations. The circuit board is fabricated with an access hole through it so that when the completed system is installed onto a wind tunnel model (chip side down), the active diaphragm is exposed to the environment. After the sensor is flip-chip attached to the circuit board, the die is underfilled to support the chip during the subsequent grinding and polishing operations. To prevent this underfill material from getting onto the sensor s diaphragms, the circuit board is fabricated with two 25- micrometer-tall polymer rings, sized so that the diaphragms fit inside the rings once the chip is attached.

Pruzan, Daniel A.↗

A technique for dynamically calibrating pressure transducers at cryogenic temperatures

A technique was developed for the calibration of dynamic pressure transducers at cryogenic temperatures. The calibration system utilizes an 8.9 Newton peak thrust shaker which oscillates a helium-filled bellows to generate a sinusoidal dynamic pressure to calibrate transducers immersed in a cryogenic environment. The system has a dynamic pressure measurement uncertainty of approximately 11% and is capable of producing peak-to-peak dynamic pressure amplitudes of 1.4 kPa over a frequency range of 40 to 100 hertz and a temperature range of 100 to 300 K. It provides an unprecedented capability of both static and dynamic calibration of pressure transducers from ambient to cryogenic temperature.

Gibbens, B. V.↗

Viscosity measurements at high temperature and high pressure: A novel technique

The extensive numerical modelling of transport phenomena was performed for the melt growth of mercury cadmium telluride. To increase the fidelity of modelling the kinematic viscosity of liquid Hg(1-x)Cd(x)Te was determined at various compositions in the range of x between 0 and 0.2 and at temperatures around and below the respective melting point. The phase diagram of Hg(1-x)Cd(x)Te shows that for this range the melting point varies from 670 C for pure HgTe to 790 C at x=0.2. The vapor pressure above the melt varies correspondingly from 15 to about 40 atm. Hence, the measurement of viscosities in this system requires a technique that allows for combinations of high temperatures and pressures. In addition, a closed isothermal system is required. The high pressure melt container must also be inert to molten Hg(1-x)Cd(x)Te to avoid possible errors from contamination of the liquid. A novel technique that largely circumvents the above experimental problems is described. Its theory is also presented.

Jin, Wei-Qing↗

Liquid-Level Monitor for Pressurized Vessels

Technique for monitoring water levels in pressurized stainless-steel cylinders, based on differences in gamma-ray attenuation coefficients in water and air, developed. Full-scale laboratory prototype system constructed to test technique. Technique usable with liquids other than water, since linear attenuation coefficients for intermediate-energy gamma rays in air considerably lower than in liquids. Also adaptable for continuous monitoring of liquid levels in resevoir systems and in underground storage tanks.

Singh, J. J.↗

Space Station pressure wall repair techniques

Space Station components are susceptible to hypervelocity impact damage from orbital debris and meteoroids. An especially vulnerable and critical space station component is the module pressure wall. Even with shielding, sufficiently large impacting particles can create penetrations ranging from pinholes to large jagged holes. This paper describes pressure wall damage repair patches along with procedures and tools for performing the repair. One patch incorporates an aluminum foil protected from the jagged hole edge with a Kevlar or foam pad. An adhesive holds the patch in place. Another patch uses a stiff plate held away from the damaged area by a low durrometer rubber ring which also seals the plate edge. An adhesive will also secure this patch in place. Procedures were developed to prepare the punctured wall surface and apply the patch under weightless and unpressurized conditions. The procedures were tested in a laboratory and in the MSFC Neutral Buoyancy Simulator with models of the patches and tools.

Gibbins, Martin N.↗

Noninvasive Techniques for Intracranial Pressure Assessment: A Review from Aerospace Medicine Perspective

Microgravity-induced changes in fluid distribution and other physiological factors due to space flight have been implicated as the cause of increased intracranial pressure (ICP) in a number of space crewmembers. The modest levels of ICP elevation and absence of severe symptoms in this group do not warrant invasive diagnostic interventions. However, the long-term trends and residual or consequential changes secondary to the observed ICP elevation in this group are not yet known. Therefore, close attention is needed to evaluate the potential techniques of noninvasively assessing ICP, including those feasible for in-flight use. Of particular interest is continuity between ground and in-flight testing, whereby data from the same or different techniques allow reasonably dependable estimation of ICP trends and responses. Methods: A thorough review of current literature, analysis of NASA data, and interviews with subject matter experts were conducted to construct a presentation that reflects the state of the art for noninvasive ICP measurement and monitoring. Results: Multiple imaging and non-imaging modalities are available to assess ICP in terrestrial clinical and experimental environments. Imaging alternatives include magnetic resonance imaging (MRI) and high-resolution sonography. Non-imaging techniques include transcranial Doppler, certain audiological methods, and venous ophthalmodynamometry, among others. Special functional techniques have been proposed recently that allow the use of advanced MRI methods to calculate ICP in addition to the acquisition of high-resolution images. Our data include many of these applications, with several cases of correlation with lumbar puncture, the invasive "gold standard" measurement of ICP.

Hamilton, Douglas R.↗

F/NAS/ Pressure Temperature Retrieval Techniques

The purpose of this investigation is to study methods and ways for rapid inversion programs involving the correlated k-method, and to modify the existing programs so that the rapid analysis of data can be accomplished. The earth's atmosphere as well as those around the planets consist of gases which emit radiation in the infrared spectral region, providing wealth of information about chemical and physical processes in the atmosphere. The atmospheric molecular constituents absorb and radiate by vibrational and rotational transitions, and the observed spectra exhibit characteristic spectral features in the region of the electromagnetic spectrum. The observed absorption or thermal emission spectra may be obtained with space-borne high resolution infrared spectrometers the 50-1000 micrometers spectral region. A detailed analysis of the observed spectra leads to information about the atmospheric thermal structure, composition, and the physical and chemical processes. The analytic techniques involve the development of radiative transfer models for the calculation of the observed radiance and transmittances for realistic atmospheric conditions and observational geometries, and the development of inversion methods for retrieval of atmospheric parameters from the observations.

Poularikas, Alexander↗

Surface Measurement Techniques Temperature and Pressure Sensitive Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence,which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. Tl e basic photophysics, calibration, accuracy and the response of a luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John P.↗

F/NAS/ Pressure Temperature Retrieval Techniques

The purpose of this investigation is to study methods and ways for rapid inversion programs involving the correlated k-method, and to modify the existing programs so that the rapid analysis of data can be accomplished. This short paper presents the background regarding the research as well as accomplishments made during the contract period.

Poularikas, Alexander↗