Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse shape analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PSR J0030+0451 Mass and Radius from NICER Data and Implications for the Properties of Neutron Star Matter

Neutron stars are not only of astrophysical interest, but are also of great interest to nuclear physicists because their attributes can be used to determine the properties of the dense matter in their cores. One of the most informative approaches for determining the equation of state (EoS) of this dense matter is to measure both a star’s equatorial circumferential radius Re and its gravitational mass M. Here we report estimates of the mass and radius of the isolated 205.53 Hz millisecond pulsar PSRJ0030+0451 obtained using a Bayesian inference approach to analyze its energy-dependent thermal X-ray waveform, which was observed using the Neutron Star Interior Composition Explorer (NICER). This approach is thought to be less subject to systematic errors than other approaches for estimating neutron star radii. We explored a variety of emission patterns on the stellar surface. Our best-fit model has three oval, uniform-temperature emitting spots and provides an excellent description of the pulse waveform observed using NICER. The radius and mass estimates given by this model are Re = 13.02+1.24-1.06 km andM = 1.44+0.15-0.14 Mmoon (68%). The independent analysis reported in the companion paper by Riley et al. explores different emitting spot models, but finds spot shapes and locations and estimates of Re and M that are consistent with those found in this work. We show that our measurements of Re and M for PSRJ0030+0451 improve the astrophysical constraints on the EoS of cold, catalyzed matter above nuclear saturation density.

M C Miller↗

Analysis of mode-locked and intracavity frequency-doubled Nd:YAG laser

The paper presents analytical and computer studies of the CW mode-locked and intracavity frequency-doubled Nd:YAG laser which provide new insight into the operation, including the detuning behavior, of this type of laser. Computer solutions show that the steady-state pulse shape for this laser is much closer to a truncated cosine than to a Gaussian; there is little spectral broadening for on-resonance operation; and the chirp is negligible. This leads to a simplified analytical model carried out entirely in the time domain, with atomic linewidth effects ignored. Simple analytical results for on-resonance pulse shape, pulse width, signal intensity, and harmonic conversion efficiency in terms of basic laser parameters are derived from this model. A simplified physical description of the detuning behavior is also developed. Agreement is found with experimental studies showing that the pulsewidth decreases as the modulation frequency is detuned off resonance; the harmonic power output initially increases and then decreases; and the pulse shape develops a sharp-edged asymmetry of opposite sense for opposite signs of detuning.

Siegman, A. E.↗

Faraday Forcing of High-Temperature Levitated Liquid Metal Drops for the Measurement of Surface Tension

In this work, a method for the measurement of surface tension using continuous periodic forcing is presented. To reduce gravitational effects, samples are electrostatically levitated prior to forcing. The method, called Faraday forcing, is particularly well suited for fluids that require high temperature measurements such as liquid metals where conventional surface tension measurement methods are not possible. It offers distinct advantages over the conventional pulse-decay analysis method when the sample viscosity is high or the levitation feedback control system is noisy. In the current method, levitated drops are continuously translated about a mean position at a small, constant forcing amplitude over a range of frequencies. At a particular frequency in this range, the drop suddenly enters a state of resonance, which is confirmed by large executions of prolate/oblate deformations about the mean spherical shape. The arrival at this resonant condition is a signature that the parametric forcing frequency is equal to the drop’s natural frequency, the latter being a known function of surface tension. A description of the experimental procedure is presented. A proof of concept is given using pure Zr and a Ti(sub 39.5)Zr(sub 39.5)Ni(sub 21) alloy as examples. The results compare favorably with accepted literature values obtained using the pulse-decay method.

Nevin Brosius↗

Analysis of Cerenkov pulses recorded simultaneously at two sites

The agreement between measured distances to maximum for approx. 49 simultaneous Cerenkov pulse profiles from different sites is + or - approx. 0.1 km near 4.5 km and + or - 0.5 km near 7 km. Uncertainty in depths of maximum are approx. + or - 10 g sq and + or - 30 g cm/2 respectively. Usually the Hillas-Patterson simulation is able to fit both pulse shapes satisfactorily using a single N(x) profile.

Liebing, D. F.↗

Laser modulation of optical absorption in ZnSe

The possibility of producing and detecting laser induced modulation of absorption (LIMA) in ZnSe crystals using a moderate laser intensity of about 6 mw output was investigated. The modulation is smaller than that previously obtained with higher laser photon flux, but is not too difficult to detect. Modulation of the order of a few parts in 10 to the 5th power, up to one part in 10 to the 4th power appears typical at the present. LIMA pulse shapes were recorded with varying system resolutions at a half dozen wavelengths in the visible, from 4800 A to 6000 A. Detailed data were taken, particularly at 5000 A, for a range of time intervals following laser pulse turn-on. Quantitative study of the excitation and decay kinetics of these is underway, though analysis is not complete. Major features are discussed with attention centered upon the detailed measurements made most recently at 5000 A.

Major, R. W.↗

Radar altimeter mean return wave forms from near-normal-incidence ocean surface scattering

For a nearly Gaussian transmitted pulse shape scattered from a nearly Gaussian distributed sea surface, a small argument series expansion of one term lead to a several term power series expression for the mean return waveform. Specific expressions are given for the first four terms. These results, which require less computer time than numerical convolution, are useful for data analysis from current or past radar altimeters and for design studies of future systems. Several representative results are presented for an idealized Seasat-1 radar altimeter.

Hayne, G. S.↗

Design of a Microwave Assisted Discharge Inductive Plasma Accelerator

The design and construction of a thruster that employs electrodeless plasma preionization and pulsed inductive acceleration is described. Preionization is achieved through an electron cyclotron resonance discharge that produces a weakly-ionized plasma at the face of a conical theta pinch-shaped inductive coil. The presence of the preionized plasma allows for current sheet formation at lower discharge voltages than those employed in other pulsed inductive accelerators that do not employ preionization. The location of the electron cyclotron resonance discharge is controlled through the design of the applied magnetic field in the thruster. Finite element analysis shows that there is an arrangement of permanent magnets that yields a small volume of resonant magnetic field at the coil face. Preionization in the resonant zone leads to current sheet formation at the coil face, which minimizes the initial inductance of the pulse circuit and maximizes the potential electrical efficiency of the accelerator. A magnet assembly was constructed around an inductive coil to provide structural support to the selected arrangement of neodymium magnets. Measured values of the resulting magnetic field compare favorably with the finite element model.

Hallock, Ashley K.↗

Measurement of Atmospheric CO2 Column Concentrations to Cloud Tops With a Pulsed Multi-Wavelength Airborne Lidar

We have measured the column-averaged atmospheric CO2 mixing ratio to a variety of cloud tops by using an airborne pulsed multi-wavelength integrated-path differential absorption (IPDA) lidar. Airborne measurements were made at altitudes up to 13 km during the 2011, 2013 and 2014 NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) science campaigns flown in the United States West and Midwest and were compared to those from an in situ sensor. Analysis of the lidar backscatter profiles shows the average cloud top reflectance was approx. 5% for the CO2 measurement at 1572.335 nm except to cirrus clouds, which had lower reflectance. The energies for 1 micro-s wide laser pulses reflected from cloud tops were sufficient to allow clear identification of CO2 absorption line shape and then to allow retrievals of atmospheric column CO2 from the aircraft to cloud tops more than 90% of the time. Retrievals from the CO2 measurements to cloud tops had minimal bias but larger standard deviations when compared to those made to the ground, depending on cloud top roughness and reflectance. The measurements show this new capability helps resolve CO2 horizontal and vertical gradients in the atmosphere. When used with nearby full-column measurements to ground, the CO2 measurements to cloud tops can be used to estimate the partial-column CO2 concentration below clouds, which should lead to better estimates of surface carbon sources and sinks. This additional capability of the range-resolved CO2 IPDA lidar technique provides a new benefit for studying the carbon cycle in future airborne and space-based CO2 missions.

atmospheric↗

Analysis of requirements for GEOS-C laser cube-corner reflector panels

A mathematical analysis of the tradeoffs and requirements was performed to develop an improved array design which will give stronger returns at lower elevation angles and reduce pulse spread in the return. It was determined that a zenith angle of 75deg can be obtained with an array with an area of 0.28 sq m, if the array is shaped on the surface of a 45 deg cone whose axis is coincident to the satellite axis. The total weight of the truncated pyramid array with 270 cube corners is calculated to be not more than 50% greater than the GEOS 2 array, while the efficiency is increased 275%.

Minott, P. O.↗

Remote sensing of two-dimensional magnetopause structures

The study presents a technique for analyzing remote measurements made by a single spacecraft of 2D disturbances in the ambient magnetosheath or magnetospheric magnetic field caused, for example, by flux transfer events or pressure pulses. The methodology is based on a recent linear theory for isentropic field-aligned MHD flow over gently sloping 2D obstacles. The technique uses only magnetic field measurements and can provide information about the orientation and actual cross-sectional shape of the event, as well as information about the spacecraft trajectory relative to the bulge. Analysis of two sample events, one recorded by the AMPTE/IRM spacecraft in the magnetosheath and the other by AMPTE/CCE in the magnetosphere, indicates that the bulges on the magnetopause surface causing the magnetic field and flow perturbations for these events did not have the semicircular cross section suggested in previous work; instead they had a more elongated shape, the dimension tangential to the magnetopause being substantially larger than that normal to it.

Walthour, D. W.↗

Ames collaborative study of cosmic ray neutrons

The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

Hewitt, J. E.↗

Serendipitous Detections of XTE J1906+09 with the Rossi X-Ray Timing Explorer

The 89 s X-ray pulsar XTE J1906+09 was discovered during Rossi X-Ray Timing Explorer (RXTE) observations of SGR 1900+14 in 1996. Because of monitoring campaigns of SGR 1900+14, XTE J1906+09 was also monitored regularly in 1996 September, 1998 May-June, 1998 August-1999 July, and 2000 March-2001 January. A search for pulsations resulted in detections of only the two previously reported outbursts in 1996 September and 1998 August-September. Pulsed flux upper limits for the rest of the observations show that XTE J1906+09 is a transient X-ray pulsar and likely has a Be star companion. The RXTE all-sky monitor did not reveal XTE J1906+09. Pulse-timing analysis of the second outburst discovered a sinusoidal signature in the pulse frequencies that is likely produced by an orbital periastron passage. Fits to pulse phases using an orbital model and quadratic phase model have chi(exp 2) minima at orbital periods of 26-30 days for fixed mass functions of 5, 10, 15, and 20 solar masses. The pulse shape showed energy- and intensity-dependent variations. Pulse-phase spectroscopy quantified the energy-dependent variations. The phase-averaged spectrum used the pulse minimum spectrum as the background spectrum to eliminate effects from SGR 1900+14 and the Galactic ridge and was well fitted by an absorbed power law with a high-energy cutoff with column density N(sub H) = 6 +/- 1 x 10(exp 22)/sq cm, a photon index of 1.01 +/- 0.08, cutoff energy E(sub cut) = 11 +/- 1 keV, and e-folding energy E(sub fold) = 19 +/- 4 keV. Estimated 2-10 keV peak fluxes, corrected for contributions from the Galactic ridge and SGR 1900+14, are 6 x l0(exp -12) and 1.1 x 10(exp -10) ergs/sq cm/s for the 1996 and 1998 outbursts, respectively. XTE J1906+09 may be part of an unusual class of Be/X-ray binaries that do not lie on the general spin period versus orbital period correlation with the majority of Be/X-ray binaries.

Wilson, Colleen A.↗

Characterizing the System Impulse Response Function from Photon-Counting LiDAR Data

NASA's Multiple Altimeter Beam Experimental LiDAR (MABEL) is an aircraft-based photon-counting laser altimeter designed as a simulator to test measurement techniques and algorithms for Advanced Topographic Laser Altimeter System (ATLAS), the sole instrument on NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission. By measuring the time of flight, pointing angle, and absolute position for individual photons, ICESat-2 provides detailed elevation measurements of earth's surface. Calculating accurate and precise elevations requires an understanding of how photons interact with surfaces, and characterization of the photon distribution after returning from surfaces. Neither MABEL nor ATLAS records the transmitted laser pulse shape, relying instead on aggregating several pulses worth of photons, often using histograms, to characterize the pulse shape. In this paper, we assess the limitations of using histograms and propose a more robust method to describe MABEL's system impulse-response function using an exponentially modified Gaussian distribution. We also provide standard error estimates for the arithmetic mean and standard deviation calculations, and for exponentially modified Gaussian parameters using a Monte Carlo sensitivity analysis. We apply this method to photon returns from a sea ice lead and from a dry salt lake bed as case studies for estimating the standard error associated with sample size for the arithmetic mean and standard deviation, and for the exponentially modified Gaussian parameters. We use these standard errors to calculate the minimum number of photons required to find both Gaussian and exponentially modified Gaussian distribution parameters within 3 cm of their parent population values.

photoncounting↗

Radiometric calibration and processing procedure for reflective bands on LANDSAT-4 protoflight Thematic Mapper

The radiometric subsystem of NASA's LANDSAT-4 Thematic Mapper (TM) sensor is described. Special emphasis is placed on the internal calibrator (IC) pulse shapes and timing cycle. The procedures for the absolute radiometric calibration of the TM channels with a 122-centimeter integrating sphere and the transfer of radiometric calibration from the channels to the IC are reviewed. The use of the IC to calibrate TM data in the ground processing system consists of pulse integration, pulse averaging, IC state identification, linear regression analysis, and histogram equalization. An overview of the SCROUNGE-era (before August 1983) method is presented. Procedural differences between SCROUNGE and the TIPS-era (after July 1983) and the implications of these differences are discussed.

Barker, J. L.↗

Auroral, Polar Cap, and Polar Cusp Modeling and Data Analysis for the IMAGE Mission and LENA Instrument

One of the chief mysteries in the LENA perigee pass data is the lack of an apparent auroral oval in the images. Another is that in some cases ENA are seen from any direction near the Earth regardless of the latitude of the spacecraft. These facts lead one to ask a fundamental question: Is the instrument responding to ENA primarily? One possible way to get out of the "ambiguity" of the data is to assume that at least part of the signal is produced by something other than ENA. The two main candidates for this "something else" are UV light and energetic charged particles. UV light could only effect the instrument when its fan shaped aperture points toward the source. The most intense of which will be the sun, with day glow being the second strongest and the auroral zone, the third. We can rule out UV light as a prime source of counts in the perigee pass data for the following reasons: 1) The perigee pass signal is different in form and much stronger than the sun pulse signal seen just before or just after perigee; 2) There is no indication of the auroral zone, which would produce at least two peaks in the counts versus spin phase curve; 3) Mike Colliers' analysis of the sun pulse signal shows that it varies with the flux of the solar wind and not with variations in the solar UV flux. Charge particles that enter the aperture of the instrument and produce counts would show up when the instrument looks in the direction from which they come. In all of the data I am analyzing voltages were being applied to the collimators so that most charged particles should have been excluded from the instrument but this effect could still show up where the flux of energetic particles is high enough. The most likely place would be in the auroral zone where energetic electrons and protons precipitate. If these particles are producing counts then they should be seen when the instrument looks in and near the zenith direction. In nearly all of the perigee passes the zenith direction is devoid of counts.

Wilson, Gordon R.↗

Evaluation of available analytical techniques for monitoring the quality of space station potable water

To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.

Geer, Richard D.↗

Radar altimeter mean return waveforms from near-normal-incidence ocean surface scattering

Under assumptions common in radar altimetry, the mean backscattered return power for a short-pulse radar and near-normal-incidence scattering from a rough ocean surface is given by the convolution of several terms. For a nearly Gaussian transmitted pulse shape scattered from a nearly Gaussian distributed sea surface, a small-argument series expansion of one of the terms within the convolution leads to a several-term power series expansion for the mean return waveform. Specific expressions are given for the first four terms. These results, which require much less computer time than would the otherwise necessary numerical convolution, are useful for data analysis from current or past radar altimeters and for design studies of future systems. Several representative results are presented for an idealized Seasat radar altimeter.

Hayne, G. S.↗

Analysis of the interaction of a laser pulse with a silicon wafer - Determination of bulk lifetime and surface recombination velocity

The decay of excess minority carriers produced in a silicon wafer of thickness d by a laser pulse is analyzed. A comprehensive theory based on this analysis is presented for the determination of bulk lifetime Tau(b) and surface recombination velocity S. It is shown that, starting with an exponential spatial profile, the carrier profile assumes a spatially symmetrical form after approximately one time constant of the fundamental mode of decay. Expressions for the spatial average of the carrier density as a function of time are derived for three temporal laser pulse shapes: impulse, square, and Gaussian. Particular attention is paid to the time constants of the fundamental and higher modes of decay. The ratios of the time constants of the higher modes to the fundamental mode, as well as the time constant of the fundamental mode, are presented over wide ranges of values of S and d. For Sd less than about 40 sq cm/s, a two-wafer method is developed to determine Tau(b) and S; it is also shown that the requirement of d/Tau(b) greater than about 20S is sufficient to adequately guarantee that the asymptotic value of the instantaneous observed lifetime differs from the bulk lifetime by no more than 10 percent.

Luke, Keung L.↗