Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulverization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Combustion characteristics and NOx emissions of two kinds of swirl burners in a 300-MWe wall-fired pulverized-coal utility boiler

Measurements were performed in a 300-MWe wall-fired pulverized-coal utility boiler. Enhanced ignition-dual register (EI-DR) burners and centrally fuel rich (CFR) swirl coal combustion burners were installed in the bottom row of the furnace during experiments. Local mean concentrations of O{sub 2}, CO, CO{sub 2} and NOx gas species, gas temperatures, and char burnout were determined in the region of the two types of burners. For centrally fuel rich swirl coal combustion burners, local mean CO concentrations, gas temperatures and the temperature gradient are higher and mean concentrations of O{sub 2} and NOx along the jet flow direction in the burner region are lower than for the enhanced ignition-dual register burners. Moreover, the mean O{sub 2} concentration is higher and the gas temperature and mean CO concentration are lower in the side wall region. For centrally fuel rich swirl coal combustion burners in the bottom row, the combustion efficiency of the boiler increases from 96.73% to 97.09%, and NOx emission decreases from 411.5 to 355 ppm at 6% O{sub 2} compared to enhanced ignition-dual register burners and the boiler operates stably at 110 MWe without auxiliary fuel oil.

01 COAL, LIGNITE, AND PEAT↗

Combustion characteristics of pulverized coal and air/gas premixed flame in a double swirl combustor

An experimental work was performed to investigate the co-firing of pulverized coal and premixed gas/air streams in a double swirl combustor. The results showed that the NOx emissions are affected by the relative rates of thermal NOx formation and destruction via the pyrolysis of the fuel-N species in high temperature fuel-rich zones. Various burner designs were tested in order to vary the temperature history and the residence time across both coal and gas flames inside the furnace. It was found that by injecting the coal with a gas/air mixture as a combined central jet surrounded by a swirled air stream, a double flame envelope develops with high temperature fuel-rich conditions in between the two reaction zones such that the pyrolysis reactions to N{sub 2} are accelerated. A further reduction in the minimum NOx emissions, as well as in the minimum CO concentrations, was reported for the case where the coal particles are fed with the gas/air mixture in the region between the two swirled air streams. On the other hand, allocating the gas/air mixture around the swirled air-coal combustion zone provides an earlier contact with air and retards the NOx reduction mechanism in such a way that the elevated temperatures around the coal particles allow higher overall NOx emissions. The downstream impingement of opposing air jets was found more efficient than the impinging of particle non-laden premixed flames for effective NOx reduction. In both cases, there is an upstream flow from the stagnation region to the coal primary combustion region, but with the case of air impingement, the hot fuel-rich zone develops earlier. The optimum configuration was found by impinging all jets of air and coal-gas/air mixtures that pronounced minimum NOx and CO concentrations of 310 and 480ppm, respectively.

01 COAL, LIGNITE, AND PEAT↗

Formation characteristics of aerosol particles from pulverized coal pyrolysis in high-temperature environments

The formation characteristics of aerosol particles from pulverized coal pyrolysis in high temperatures are studied experimentally. By conducting a drop-tube furnace, fuel pyrolysis processes in industrial furnaces are simulated in which three different reaction temperatures of 1000, 1200, and 1400{sup o}C are considered. Experimental observations indicate that when the reaction temperature is 1000{sup o}C, submicron particles are produced, whereas the particle size is dominated by nanoscale for the temperature of 1400{sup o}C. Thermogravimetric analysis of the aerosol particles stemming from the pyrolysis temperature of 1000{sup o}C reveals that the thermal behavior of the aerosol is characterized by a three-stage reaction with increasing heating temperature: (1) a volatile-reaction stage, (2) a weak-reaction stage, and (3) a soot-reaction stage. However, with the pyrolysis temperature of 1400{sup o}C, the volatile- and weak-reaction stages almost merge together and evolve into a chemical-frozen stage. The submicron particles (i.e., 1000{sup o}C) are mainly composed of volatiles, tar, and soot, with the main component of the nanoscale particles (i.e., 1400{sup o}C) being soot. The polycyclic aromatic hydrocarbons (PAHs) contained in the aerosols are also analyzed. It is found that the PAH content in generated aerosols decreases dramatically as the pyrolysis temperature increases. 31 refs., 9 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Investigation of the relationship between particulate-bound mercury and properties of fly ash in a full-scale 100 MWe pulverized coal combustion boiler

The properties of fly ash in coal-fired boilers influence the emission of mercury from power plants into the environment. In this study, seven different bituminous coals were burned in a full-scale 100 MWe pulverized coal combustion boiler and the derived fly ash samples were collected from a mechanical hopper (MH) and an electrostatic precipitator hopper (ESP). The mercury content, specific surface area (SSA), unburned carbon, and elemental composition of the fly ash samples were analyzed to evaluate the correlation between the concentration of particulate-bound mercury and the properties of coal and fly ash. For a given coal, it was found that the mercury content in the fly ash collected from the ESP was greater than in the fly ash samples collected from the MHP. This phenomenon may be due to a lower temperature of flue gas at the ESP (about 135{sup o}C) compared to the temperature at the air preheater (about 350{sup o}C). Also, a significantly lower SSA observed in MH ash might also contribute to the observation. A comparison of the fly ash samples generated from seven different coals using statistical methods indicates that the mercury adsorbed on ESP fly ashes has a highly positive correlation with the unburned carbon content, manganese content, and SSA of the fly ash. Sulfur content in coal showed a significant negative correlation with the Hg adsorption. Manganese in fly ash is believed to participate in oxidizing volatile elemental mercury (Hg{sup 0}) to ionic mercury (Hg{sup 2+}). The oxidized mercury in flue gas can form a complex with the fly ash and then get removed before the flue gas leaves the stack of the boiler.

01 COAL, LIGNITE, AND PEAT↗

Experimental investigation on pulverized coal reburning crucially related with its ignition mode

Experimental investigation on reburning by a pulverized bituminous coal was performed in a one-dimensional flow reactor, in which the ignition statuses of the coal were monitored by on-line gas analysis, solid sampling, and direct image acquisition. The experimental results indicate that NO reduction efficiency (RE) varies nonmonotonically with stoichiometric ratio of oxygen to coal (SR) entering the reburning zone: the lower SR does not necessarily result in the higher RE, mainly due to the great influence of ignition modes of the coal. Before ignition, RE increases with increasing SR, since a little oxygen is in favor of homogeneous NO reduction. Then, RE decreases greatly after homogeneous ignition with increase of SR, due to the rapid consumption of NO-reducing species by the volatile flame in the boundary layer of the particle, before going to the flue gas for NO reduction. When the joint heterohomogeneous ignition happens with further increase of SR, the char temperature increases violently, the heterogeneous NO reduction rate rises obviously with increasing temperature, then the whole RE begins to increase again. As a result of even higher SR, the char combustion is controlled by diffusion, and it is difficult for the oxygen necessary for heterogeneous NO reduction reactions to reach the surface, then the RE decreases again. The promotion effects of char ignition on RE are more obvious at lower temperature in the reburning zone, and the SR values at which the above relevant phenomena appear are lower for coarser coal particles. 36 refs., 7 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Field-scale investigation of pulverized coal mill power consumption

Twenty field-scale tests were conducted in a 28 MW pulverized coal power plant in Healy, Alaska, to examine mill power consumption in relation to coal grind size. The intent in this field-scale study was to verify if grind size truly impacted power consumption by a detectable amount. The regression model developed from the data indicates that grind size does impact mill power consumption, with finer grinds consuming significantly more power than coarser grinds. However, other factors such as coal hardness (i.e. the lower the Hardgrove Grindability Index, or the harder the coal, the higher the power consumption) and mill throughput (i.e., the higher the throughput, the higher the power consumption) had to be included before the impact of grind size could be isolated. It was also observed that combining amperage and flow rate into a single parameter, i.e., specific amperage, hurt modeling. Cost analysis based on the regression model indicate a power savings of $19,972 per year if the coal were ground to 50% passing 76 {mu}m rather than the industry standard of 70% passing 76 {mu}m. The study also demonstrated that size reduction constituted a significant portion of the power consumption.

01 COAL, LIGNITE, AND PEAT↗

Measurement and capture of fine and ultrafine particles from a pilot-scale pulverized coal combustor with an electrostatic precipitator

Experiments were carried out in a pilot-scale pulverized coal combustor at the Energy and Environmental Research Center (EERC) burning a Powder River Basin (PRB) subbituminous coal. A scanning mobility particle sizer (SMPS) and an electrical low-pressure impactor (ELPI) were used to measure the particle size distributions (PSDs) in the range of 17 nm to 10 m at the inlet and outlet of the electrostatic precipitator (ESP). At the ESP inlet, a high number concentration of ultrafine particles was found, with the peak at approximately 75 nm. A trimodal PSD for mass concentration was observed with the modes at approximately 80-100 nm, 1-2 {mu}m, and 10 {mu}m. The penetration of ultrafine particles through the ESP increased dramatically as particle size decreased below 70 nm, attributable to insufficient or partial charging of the ultrafine particles. Injection of nanostructured fine-particle sorbents for capture of toxic metals in the flue gas caused high penetration of the ultrafine particles through the ESP. The conventional ESP was modified to enhance charging using soft X-ray irradiation. A slipstream of flue gas was introduced from the pilot-scale facility and passed through this modified ESP. Enhancement of particle capture was observed with the soft X-ray irradiation when moderate voltages were used in the ESP, indicating more efficient charging of fine particles. 32 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Predictive modeling of a subcritical pulverized-coal power plant for optimization: Parameter estimation, validation, and application

As renewable power generation deployment increases, fossil fuel plants are increasingly required to operate more flexibly. Many coal-fired power plants were originally designed to operate at base load and do not operate optimally at partial load. Predictive first-principles plant-wide models can be employed to identify opportunities for flexibility improvements and diagnose low-load operating issues. This paper describes the application of the Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES) to model and optimize flexible power plant operations. The key benefits of using IDAES are that it provides an open-source, fully equation-oriented modeling framework for efficient modular model construction, reuse, and customization, together with a mathematical optimization framework leveraging powerful, state-of-the-art solvers. The process systems engineering workflow from predictive process simulation to parameter estimation, model validation, and plant optimization is applicable to a variety of existing and next-generation energy systems as well as other chemical and environmental processes. Here, to demonstrate this capability, a physics-based, steady-state model was developed to improve full- and part-load performance of the Escalante Generating Station, a 245 MWe (net) subcritical pulverized coal-fired power plant owned and operated by Tri-State Generation and Transmission Association. Specifically, sixty-nine model parameters were simultaneously estimated from several months of operating data enabling prediction of flow rates, temperatures, pressures, and steam quality throughout the plant. The validated model was leveraged by Escalante to reduce the minimum operating load from 90 MW to 50 MW by diagnosing a low-load water-hammer issue, enabling coal usage and emissions reductions during periods of low power demand. Additionally, opportunities for heat rate reduction (i.e., efficiency improvement) through a steeper sliding-pressure approach to load-following and optimization of other boiler operating variables were also identified and quantified. For example, a potential efficiency improvement of 0.7 percentage points was observed at half-load operation.

01 COAL, LIGNITE, AND PEAT↗

Derate Mitigation Options for Pulverized Coal Power Plant Carbon Capture Retrofits

Carbon capture and storage (CCS) technologies available in the near-term for pulverized coal-fueled power plants (i.e., post combustion solvent technologies) require substantial capital investment and result in marked decrease in electricity available for sale to the grid. The impact to overall plant economics can be mitigated for new plant designs (where the entire plant can be optimized around the CCS system). However, existing coal-fueled power plants were designed without the knowledge or intent to retrofit a CCS process, and it is simply not possible to re-engineer an existing plant in a manner that it could achieve the same performance as if it was originally designed and optimized for CCS technology. Pairing an auxiliary steam supply to the capture system is a technically feasible option to mitigate the derate resulting from diverting steam away from an existing steam turbine and continuing to run that turbine at steam flow rates and properties outside of the original design specifications. The results of this analysis strongly support the merits of meeting the steam and power requirements for a retrofitted post-combustion solvent based carbon dioxide (CO2) capture system with an auxiliary combined heat and power (CHP) plant rather than robbing the base plant (i.e., diverting steam from the existing steam cycle and electricity from sale to the grid).

01 COAL, LIGNITE, AND PEAT↗

Application of LES-CFD for predicting pulverized-coal working conditions after installation of NOx control system

The upcoming environmental requirements outlined at the 2017 European Commission Integrated Pollution Prevention and Control (IPPC) are becoming more and more strict in comparison to the existing standards – IED 2010/75/EU. Questions arise about changes in boiler operating conditions after the adoption of the regulations to fulfill specified emission limits. Of initial concern is the question of which technology to pursue in order to reach the specified level of NOx emissions at 150 mg/Nm 3 @6%O 2 . By introducing an air staging technique the NOx limit can be partially achieved; however these changes affect the boiler operation in a detrimental way. In order to investigate impact of de-NOx installation on the temperature and heat flux distribution, numerical techniques can be used. In order to determine the impact of the changes in the boiler operation, here this paper presents the application of an advanced, multiphase open-source code Arches, developed at the University of Utah for modeling pulverized-coal combustion using Large-Eddy Simulation (LES). Numerical simulations showed the effect on the boiler's working parameters e.g., heat-transfer rate, temperature distribution, species concentration, and NOx emission before and after proposed modifications.

54 ENVIRONMENTAL SCIENCES↗

Beneficiation of pulverized coal combustion fly ash in fluidised bed reactors

The paper addresses the thermal treatment of pulverized coal combustion fly ash belonging to the group C of Geldart powder classification in unconventional configurations of fluidised bed reactors. A sound-assisted fluidised bed combustor operated at 850 and 750 C, and a fluidised bed combustor characterized by a conical geometry, operated at 850 C, are the two lab-scale reactors tested. Combustion experiments have been carried out at different air excesses, ranging between 10% and 170%, and in the case of the conical fluidization column with different bed inventory. Both tested configurations have been proved to be efficient to reduce the carbon content initially present in the fly ash of 11%{sub w}, to a very low level, generally smaller than 1%{sub w}. Both the fly ash residence time in the reactor and the air excess strongly influenced the reactor performance. Residence times of 3-4 min and 10-60 min have been estimated for experiments carried out with the sound-assisted fluidised bed combustor and with the conical fluidised bed combustor, respectively. Regarding the possibility of a concurrent reduction of unburned carbon in the ash and of a particle size separation of the beneficiated material, on the basis of the obtained experimental data, the sound-assisted fluidised bed combustor is not able to separate the broad particle size distribution of the fly ash in different outlet solid streams. The use of a conical fluidised bed combustor is promising to realize an efficient separation of the inlet broad particle size distribution of the fly ash fed to the reactor into narrower outlet solid streams extracted from different locations: combustor exit, top and bottom of the bed. In this framework a hydrodynamic characterization of binary mixtures in a conical fluidised bed column carried out at ambient and high temperature (850 C) has demonstrated that the operating conditions of the conical fluidised bed combustor can be chosen on the basis of a compromise between the requirements of a complete fluidization of the bed material and a high level of segregation of the finer particles present in the bed. (author)

01 COAL, LIGNITE, AND PEAT↗

A semi-empirical NO x model for LES in pulverized coal air-staged combustion

Numerical simulation of pulverized coal combustion with the large eddy simulation (LES) method can provides important instructions on the design optimization of boilers. Because of its huge computational cost, a simple but reliable NO x prediction model is required in LES. Through the air-staged combustion experiments of six kinds of coals which conducted in an electric heated down-fired furnace (DFF), the relationship between NO x reduction and CO+H 2 generation in the fuel-rich zone was identified. Based on this observation, a semi-empirical modeling strategy was proposed: instead of CHi which is difficult to calculate, the concentration of CO+H 2 is used to quantify NO homogeneous reduction. An integrated NO x prediction model was proposed and implemented into LES simulation. Here, the results proved the new model can accurately predict different NO x evolution characteristics under various conditions. Furthermore, the comparison indicated the LES method performs better on NO x prediction than the RANS method, especially in the area where the turbulent fluctuation is relatively stronger.

97 MATHEMATICS AND COMPUTING↗

Utilization of blended fluidized bed combustion (FBC) ash and pulverized coal combustion (PCC) fly ash in geopolymer

In this paper, synthesis of geopolymer from fluidized bed combustion (FBC) ash and pulverized coal combustion (PCC) fly ash was studied in order to effectively utilize both ashes. FBC-fly ash and bottom ash were inter-ground to three different finenesses. The ashes were mixed with as-received PCC-fly ash in various proportions and used as source material for synthesis of geopolymer. Sodium silicate (Na{sub 2}SiO{sub 3}) and 10 M sodium hydroxide (NaOH) solutions at mass ratio of Na{sub 2}SiO{sub 3}/NaOH of 1.5 and curing temperature of 65 deg. C for 48 h were used for making geopolymer. X-ray diffraction (XRD), scanning electron microscopy (SEM), degree of reaction, and thermal gravimetric analysis (TGA) were performed on the geopolymer pastes. Compressive strength was also tested on geopolymer mortars. The results show that high strength geopolymer mortars of 35.0-44.0 MPa can be produced using mixture of ground FBC ash and as-received PCC-fly ash. Fine FBC ash is more reactive and results in higher degree of reaction and higher strength geopolymer as compared to the use of coarser FBC ash. Grinding increases reactivity of ash by means of increasing surface area and the amount of reactive phase of the ash. In addition, the packing effect due to fine particles also contributed to increase in strength of geopolymers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combustion behaviors and kinetics of sewage sludge blended with pulverized coal: With and without catalysts

Highlights: • High mass percentage of SS resulted in a great decrease in index S of the blends. • The combustion behaviors and kinetics of the blends with catalysts were studied. • All the catalysts improved the combustion performance of the blended fuel. • All the catalysts reduced the activation energy needed to combustion reaction. • Fe{sub 2}O{sub 3} was an optimal option for catalytic combustion among the tested catalysts. - Abstract: The combustion behaviors of sewage sludge (SS), pulverized coal (PC), and their blends were studied using a thermogravimetric analyzer. The effect of the mass ratio of SS to PC on the co-combustion characteristics was analyzed. The experiments showed that the ignition performance of the blends improved significantly as the mass percentage of SS increased, but its combustion intensity decreased. The burnout temperature (T{sub b}) and comprehensive combustibility index (S) of the blends were almost unchanged when the mass percentage of SS was less than 10%. However, a high mass percentage of SS (>10%) resulted in a great increase in T{sub b} and a notable decrease in S. Subsequently, the effects of different catalysts (CaO, CeO{sub 2}, MnO{sub 2}, and Fe{sub 2}O{sub 3}) on the combustion characteristics and activation energy of the SS/PC blend were investigated. The four catalysts promoted the release and combustion of volatile matters in the blended fuels and shifted their combustion profiles to a low temperature. In addition, their peak separating tendencies were obvious at 350–550 C, resulting in high peak widths. All the catalysts improved combustion activity of the blended fuel and accelerated fixed carbon combustion, which decreased the ignition temperature and burnout temperature of the fuels. CeO{sub 2} had the best catalytic effects in terms of the comprehensive combustion performance and activation energy, followed closely by Fe{sub 2}O{sub 3}. However, the rare-earth compounds are expensive to be applied in the catalytic combustion process of SS/PC blend at present. Based on both catalytic effects and economy, Fe{sub 2}O{sub 3} was potentially an optimal option for catalytic combustion among the tested catalysts.

09 BIOMASS FUELS↗

Dynamic Modeling, Parameter Estimation, and Data Reconciliation of a Supercritical Pulverized Coal-Fired Boiler

A high-fidelity, spatially distributed dynamic model of a supercritical pulverized coal-fired boiler was developed for calculating transient thermal profiles of the boiler tubes, which are often not measured or unmeasurable in industrial settings due to the harsh operating conditions. In this work, rigorous models of the subcritical and supercritical steam properties, which can be highly nonlinear, were used to capture the transition between two-phase and one-phase flow, respectively, as supercritical boilers frequently transition through the critical point during load-following operation. The transient boiler model was also used for data reconciliation and parameter estimation for the purpose of model validation against industrial data. An approach was developed to reduce the size of large-scale reconciliation problem by focusing on the implementation of bias terms for the reconciled variables, which can be estimated in place of the reconciled variables themselves. In addition, a functional approximation of the reconciliation problem was defined so that it can be more simply optimized. Combining this functional approximation optimization with reformulation of the reconciliation problem considering measurement biases can significantly improve the tractability of many such large-scale problems. The validated boiler model was then used to study transient responses under load-following operation with specific attention on the calculation of unmeasurable variables.

42 ENGINEERING↗

Cu Doping Increases Capacity Retention in LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) by Altering the Potential of the Ni-Based Redox Couple and Inhibiting Particle Pulverization

To discern the influence of Cu 2+ as a dopant on both the structural and electrochemical characteristics of LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622), Cu 2+ (aq) was added to the coprecipitation synthesis from the constituent ions. At 5 mol % Cu 2+ , a single-phase Cu-NMC product results, evidenced by an increase in d-spacing along the [003] and [104] directions and a slight increase in the crystal volume of the R–3m hexagonal (rock-salt superstructure) lattice. XRD data and high-resolution TEM imaging support Cu 2+ doping primarily on the transition metal 3b Wyckoff sites. Here, galvanostatic cycling of Cu-NMC shows a reversible gravimetric capacity of 102 mAh/g compared to 136 mAh/g for undoped NMC. Despite the lower capacity, the discharge capacity retention of Cu-NMC is 89% after 100 cycles compared to only 70% for NMC. XPS analysis reveals that this lower capacity is due to an increase in the concentration of Ni 3+ ions at the surface, while XRD data collected at the top and bottom of charge show a smaller decrease in crystalline domain size for Cu-NMC (40.5% decrease) compared to NMC (74.7% decrease), translating to pulverization of the secondary particles.

25 ENERGY STORAGE↗

Stochastic simulation of pulverized coal (PC) processes

An increasing population and electricity demand in the U.S. require capacity expansion of power systems. The National Energy Technology Laboratory (NETL), U.S. Department of Energy (DOE), has invested considerable efforts on research and development to improve the design and simulation of these power plants. Incorporation of novel process synthesis techniques and realistic simulation methodologies yield optimal flowsheet configurations and accurate estimation of their performance parameters. To provide a better estimation of such performance indicators, simulation models should predict the process behavior based on not only deterministic values of well-known input parameters but also uncertain variables associated with simulation assumptions. In this work, the stochastic simulation of a load-following pulverized coal (PC) power plant takes into account the variation of three input variables, namely, atmospheric air temperature, atmospheric air humidity, and generation load. These uncertain variables are characterized with probability density functions (pdfs) obtained from available atmospheric and electrical energy generation data. The stochastic simulation is carried out by obtaining a sample of values from the pdfs that generates a set of scenarios under which the model is run. An efficient sampling technique [Hammersley sequence sampling (HSS)] guarantees a set of scenarios uniformly distributed throughout the uncertain variable range. Then, each model run generates results on performance parameters as cycle efficiency, carbon emissions, sulfur emissions, and water consumption that are statistically analyzed after all runs are completed. Among these parameters, water consumption is of importance because an increasing demand has been observed mostly in arid regions of the country and, therefore, constrains the operability of the processes. This water consumption is significantly affected by atmospheric uncertainties. The original deterministic process model simulation was designed in Aspen Plus, and a CAPE-OPEN compliant stochastic simulation capability is employed to run the uncertainty analysis. Initially, the influences of atmospheric conditions and load change on the performance parameters are analyzed separately to understand their individual influences on the process, and then their simultaneous variation is analyzed to generate more realistic estimations of the process performance.

97 MATHEMATICS AND COMPUTING↗