Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Marine and Hydrokinetic ToolKit (MHKiT) for Data Quality Control and Analysis [Slides]

The ability to collect, ingest, condition, reduce, quality control, process, visualize, and store data in a standardized way is critical at all stages of Marine Energy (ME) research and technology/project development. MHKiT is an open-source, standardized suite of ME data processing functions that provides the ability to ingest, condition, reduce, quality control, process, visualize and store ME data. MHKiT is developed in both Python and Matlab.

16 TIDAL AND WAVE POWER↗

Development of a Display Tool to Quality Control Weather Balloon Data for Space Launch Vehicles

Continuous atmospheric data analysis is an important factor for space launch vehicle design and operations. The balloon quality control tool was developed by NASA’s Marshall Space Flight Center (MSFC) Natural Environments Branch (NEB) for monitoring quality control processes and verifying the automated flags created on the balloon data sets analyzed. The data sets currently analyzed are comprised of high-resolution and low-resolution balloon data from NASA Kennedy Space Center (KSC), co-located on the United States Air Force’s Eastern range (ER) at the Cape Canaveral Air Force Station. The NEB was tasked to perform a quality assessment of these data sets and needed a tool to confirm the quality control (QC) flags produced from an automated process and add additional QC flags if necessary. This Graphical User Interface (GUI) was developed to visualize all of the data from these balloon sets, display any flags from the automated QC process, and add additional flags to variables if necessary. The GUI was developed in Python 3.6 utilizing different packages available such as pandas for data analysis and manipulation, NumPy for high-performance multidimensional array and tools to compute with and manipulate arrays, Matplotlib for plotting data and Tkinter to build the GUI.

Jessica K Headley↗

Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitivity, and careful quality control in any study of composite materials.

Clements, L. L.↗

Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitvity, and careful quality control in any study of composite materials. Previously announced in STAR as N80-33493

Clements, L. L.↗

Development of a Display Tool to Quality Control Weather Balloon Data for Space Launch Vehicles Using Python

Continuous atmospheric data analysis is an important factor for space launch vehicle design and operations. The balloon quality control tool was developed by NASA’s Marshall Space Flight Center (MSFC) Natural Environments Branch (NEB) for monitoring quality control processes and verifying the automated flags created on the balloon data sets analyzed. The data sets currently analyzed are comprised of high-resolution and low-resolution balloon data from NASA Kennedy Space Center (KSC), co-located on the United States Air Force’s Eastern range (ER) at the Cape Canaveral Air Force Station. The NEB was tasked to perform a quality assessment of these data sets and needed a tool to confirm the quality control (QC) flags produced from an automated process and add additional QC flags if necessary. This Graphical User Interface (GUI) was developed to visualize all of the data from these balloon sets, display any flags from the automated QC process, and add additional flags to variables if necessary. The GUI was developed in Python 3.6 utilizing different packages available such as pandas for data analysis and manipulation, NumPy for high-performance multidimensional array and tools to compute with and manipulate arrays, Matplotlib for plotting data and Tkinter to build the GUI.

Jessica K Headley↗

CRN5EXP: Expert system for statistical quality control

The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.

Hentea, Mariana↗

Automated quality control for stitching of textile articles

Quality control for stitching of a textile article is performed by measuring thread tension in the stitches as the stitches are being made, determining locations of the stitches, and generating a map including the locations and stitching data derived from the measured thread tensions. The stitching data can be analyzed, off-line or in real time, to identify defective stitches. Defective stitches can then be repaired. Real time analysis of the thread tensions allows problems such as broken needle threads to be corrected immediately.

Miller, Jeffrey L.↗

A review of functions, attributes, properties and measurements for the quality control of proton exchange membrane fuel cell components

Quality control (QC) is an essential part of fuel cell technology industrialization, providing means to reduce cost of components, enhancing the reliability of the final product, and offering specification guidance for new entrants in the supply chain. The membrane electrode assembly (MEA), including membrane, catalyst layer (CL), and gas diffusion layer (GDL), as well as bipolar plate (BP), are key components of a proton exchange membrane (PEM) fuel cell, and the attributes of each component strongly correlate with the cell performance and longevity. To ensure the quality of the fuel cell, it is of great importance to characterize the properties with respect to the standardization of component/sub-component specifications. In collaboration with the fuel cell industry, this work aims at establishing compendiums of attributes, or so-called books of attributes, of key fuel cell components for the QC of PEM fuel cells through reviewing, identifying, categorizing, and prioritizing the main attributes/properties that determine their functionalities. The books of attributes for the major PEM fuel cell components include catalyst coated membrane (CCM) as a sub-assembly, GDL, and BP. To address the full spectrum of fuel cell components, gaskets and sub-gaskets are also included.

25 ENERGY STORAGE↗

SU-G-TeP4-14: Quality Control of Treatment Planning Using Knowledge-Based Planning Across a System of Radiation Oncology Practices

Purpose: There is potentially a wide variation in plan quality for a certain disease site, even for clinics located in the same system of hospitals. We have used a prostate-specific knowledge-based planning (KBP) model as a quality control tool to investigate the variation in prostate treatment planning across a network of affiliated radiation oncology departments. Methods: A previously created KBP model was applied to 10 patients each from 4 community-based clinics (Clinics A, B, C, and D). The KBP model was developed using RapidPlan (Eclipse v13.5, Varian Medical Systems) from 60 prostate/prostate bed IMRT plans that were originally planned using an in-house treatment planning system at the central institution of the community-based clinics. The dosimetric plan quality (target coverage and normal-tissue sparing) of each model-generated plan was compared to the respective clinically-used plan. Each community-based clinic utilized the same planning goals to develop the clinically-used plans that were used at the main institution. Results: Across all 4 clinics, the model-generated plans decreased the mean dose to the rectum by varying amounts (on average, 12.5, 2.6, 4.5, and 2.7 Gy for Clinics A, B, C, and D, respectively). The mean dose to the bladder also decreased with the model-generated plans (5.4, 2.3, 3.0, and 4.1 Gy, respectively). The KBP model also identified that target coverage (D95%) improvements were possible for for Clinics A, B, and D (0.12, 1.65, and 2.75%) while target coverage decreased by 0.72% for Clinic C, demonstrating potentially different trade-offs made in clinical plans at different institutions. Conclusion: Quality control of dosimetric plan quality across a system of radiation oncology practices is possible with knowledge-based planning. By using a quality KBP model, smaller community-based clinics can potentially identify the areas of their treatment plans that may be improved, whether it be in normal-tissue sparing or improved target coverage. M. Matuszak has research funding for KBP from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

FC Site 4.0 - NLR Scanning Lidar (Halo XR+ 235) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 4.2 - NLR Scanning Lidar (Halo XR+ 199) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

FC Site 1.9 - NLR Scanning Lidar (Halo XR+ 200) / Standardized and Quality-Controlled Data

This dataset contains lidar data that have been standardized and quality-controlled through NatLabRockies/FIEXTA/LiDARGO (https://github.com/NatLabRockies/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitate data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

In-Line Optical Transmission Imaging of Decals for Quality Control - Task 3

Quality monitoring is a critical aspect for manufacturing systems. Ideally the monitoring would be done in-line, be non-contact, non-destructive, and fast. This would enable reduced scrap and higher throughput. This poster presents an optical transmission method for evaluating and mapping coatings. With the method shown in the poster we can visualize optical variations on the macro and micro scales. This allows us to see the overall trend in loading in both the cross web and down web directions. Furthermore, we can visualize defects such dewetting spots, streaks, clumps, and pinholes where there is a lack of coating. The optical transmission signal has been found to be proportional to the IrOx loading signal using XRF measurements. Therefore, an optical transmission setup can be installed in-line and allow for a fast, non-contact method for mapping loading variations and defects.

coating uniformity↗

Automatic Waveform Quality Control for Surface Waves Using Machine Learning

Surface-wave seismograms are widely used by researchers to study Earth’s interior and earthquakes. To extract information reliably and robustly from a suite of surface waveforms, the signals require quality control screening to reduce artifacts from signal complexity and noise. This process has usually been completed by human experts labeling each waveform visually, which is time consuming and tedious for large data sets. We explore automated approaches to improve the efficiency of waveform quality control processing by investigating logistic regression, support vector machines, K-nearest neighbors, random forests (RF), and artificial neural networks (ANN) algorithms. To speed up signal quality assessment, we trained these five machine learning (ML) methods using nearly 400,000 human-labeled waveforms. The ANN and RF models outperformed other algorithms and achieved a test accuracy of 92%. We evaluated these two best-performing models using seismic events from geographic regions not used for training. The results show that the two trained models agree with labels from human analysts but required only 0.4% of the time. Although the original (human) quality assignments assessed general waveform signal-to-noise, the ANN or RF labels can help facilitate detailed waveform analysis. Our investigations demonstrate the capability of the automated processing using these two ML models to reduce outliers in surface-wave-related measurements without human quality control screening.

58 GEOSCIENCES↗

The QCECOR Value-Added Product: Quality-Controlled Eddy Correlation Flux Measurements

Eddy correlation flux (ECOR) measurement system stations are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility to provide surface turbulence flux measurements. In recent years, ARM has significantly enhanced its ECOR systems and made them available at all its primary research observatories and mobile facilities. However, the original ECOR data were not corrected through common eddy correlation corrections and still contain suspicious data due to instrument and measurement uncertainties. Such uncertainties in the ECOR surface turbulence fluxes hampered their uses by the user community. To improve the ECOR data, we develop a value-added product (VAP) —the Quality-Controlled Eddy Correlation Flux (QCECOR) — by applying the following necessary corrections and quality control (QC) procedures: Eddy correlation corrections. Determination of the quality-controlled energy fluxes from the corrected ECOR fluxes. Stringent QC checks. Flagging possible incorrect fluxes due to hydrometeor impacts using the collocated surface energy balance system (SEBS) wetness measurements. The QCECOR VAP currently contains two variables: surface latent heat flux (LH) and sensible heat flux (SH), together with their QC flags. When SEBS are collocated with ECOR, the wetness measurements from SEBS are used to flag the LH that may be incorrect due to hydrometeors such as precipitation, dew, or frost. An indeterminate flag is given to those that fail the wetness test. The QCECOR data are currently available at the Southern Great Plains (SGP) atmospheric observatory for the ARM extended facilities of E1, E3, E5, E6, E10, E14, E16, E21, E24, E31, E33, E37, E38, E39, and E41 updated to 2018. The data are also available at the following AMF sites: PYE (Point Reyes, 2005), NIM (Niamey, Niger, 2006), FKB (Black Forest, Germany, 2007), HFE (Shouxian, China, 2008), GRW (Azores, 2009 to 2010), and MAO (Manacapuru, Brazil, 2014-2015). The algorithm is now in the process of moving to production mode. After that, QCECOR will run automatically for all available ARM sites.

47 OTHER INSTRUMENTATION↗

SU-D-BRB-02: Patient-Specific Rectal Toxicity Predictor Based Plan Quality Control for Prostate Stereotactic Body Radiation Therapy (SBRT)

Purpose: To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans. Methods: For prostate SBRT cases, four segments of rectal walls including peri-prostatic anterior rectal wall, peri-prostatic lateral rectal walls, peri-prostatic posterior rectal wall and rectum superior to prostate are identified as organs at risk and the circumference of rectal wall receiving more than 39 Gy (CRW39) and 24 Gy (CRW24) are rectal toxicity predictors. In this new geometry-dosimetry model, a patient geometry descriptor, differential circumference of rectal wall (dCRW) is used as model input geometry parameters and plan dosimetric endpoints CRW39 and CRW24 are output dosimetric parameters. Linear models are built to correlate dCRW to both CRW39 and CRW24 and established with both a linear regression method and a modified bagging ensemble machine learning method. 27 SBRT prostate cases are retrospectively studied from a dose-escalated clinical trial research. 20 prescribed 50 Gy SBRT cases are recruited to train the model and the other rescaled 7 cases are used to evaluated model feasibility and accuracy. Results: Each solved linear coefficient sequence related to CRW39 or CRW24 is a one-dimensional decreasing function of the distance from the PTV boundary, indicating that the different locations of each rectal circumference have different contributions to each particular dosimetric endpoint. The fitting errors for those trained 20 prostate SBRT cases are small with mean values of 2.39%, 2.45% relative to the endpoint values for SBRT rectal toxicity predictor CRW39 and CRW24 respectively. 1 out of 7 evaluation plans is identified as poor quality plan. After re-planning, the CRW39 and CRW24 can be reduced by 3.34% and 3%, without sacrificing PTV coverage. Conclusion: The proposed patient geometry-plan toxicity predictor model for SBRT plans can be successfully applied to plan quality control for prostate SBRT cases.

60 APPLIED LIFE SCIENCES↗