Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Pycheron: A Python-Based Seismic Waveform Data Quality Control Software Package

Supplementing an existing high-quality seismic monitoring network with openly available station data could improve coverage and decrease magnitudes of completeness; however, this can present challenges when varying levels of data quality exist. Without discerning the quality of openly available data, using it poses significant data management, analysis, and interpretation issues. Incorporating additional stations without properly identifying and mitigating data quality problems can degrade overall monitoring capability. If openly available stations are to be used routinely, a robust, automated data quality assessment for a wide range of quality control (QC) issues is essential. To meet this need, we developed Pycheron, a Python-based library for QC of seismic waveform data. Pycheron was initially based on the Incorporated Research Institutions for Seismology’s Modular Utility for STAtistical kNowledge Gathering but has been expanded to include more functionality. Pycheron can be implemented at the beginning of a data processing pipeline or can process stand-alone data sets. Its objectives are to (1) identify specific QC issues; (2) automatically assess data quality and instrumentation health; (3) serve as a basic service that all data processing builds on by alerting downstream processing algorithms to any quality degradation; and (4) improve our ability to process orders of magnitudes more data through performance optimizations. This article provides an overview of Pycheron, its features, basic workflow, and an example application using a synthetic QC data set.

58 GEOSCIENCES↗

TU-F-18A-01: Preliminary Results of a Prototype Quality Control Process for Spectral CT

Purpose: A prototype quality control (QC) phantom and analysis process has been designed specifically to monitor dual-energy CT and address the current lack of quantitative oversight of the spectral capabilities of these scanners. Methods: A prototype solid water phantom was designed with multiple material inserts, and to support both head and body protocols. Inserts included tissue equivalent and material rods (iodine, iron, calcium) at various concentrations. The oval body phantom, measuring 30cm×40cm×15cm, was scanned using four dual-energy protocols with CTDIvol ranges of 19.6–62mGy (0.516 pitch) and 10.3–32.5mGy (0.984 pitch), and rotation times ranging from 0.5-1sec. The circular head phantom, measuring 22cm in diameter by 15cm, was scanned using three dual-energy protocols with CTDIvol ranges of 67–132.6mGy (0.531 pitch) and 36.7–72.7mGy (0.969 pitch), and rotation times ranging from 0.5–0.9sec. All images were reconstructed at 50, 70, 110 and 140 keV, and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy and stability of monoenergetic reconstructions. The phantom was scanned twice on ten GE 750HD CT scanners to evaluate inter-scanner agreement, as well as ten times on a single scanner over a oneweek period to evaluate intra-scanner repeatability. Results: Preliminary analysis revealed consistent (inter- and intra-scanner) iodine quantification accuracy within 10% was only achieved for protocols in the upper half of dose levels assessed when grouped by pitch. Although all scanners undergo rigorous daily single-energy QC, iodine quantification accuracy from one scanner unexpectedly deviated from the other nine substantially. In general, inter-scanner agreement and intra-scanner repeatability varied with dose, rotation time and reconstructed keV. Conclusion: Preliminary results indicate the need for a dual-energy QC process to ensure inter-scanner agreement and intra-scanner repeatability. In particular, iodine quantification accuracy within 10% may not be achievable using lower dose techniques. Future plans include longer term dual-energy CT QC data collection. In-kind financial support was provided by GE Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-01: A Statistical Modeling Method for Quality Control of Intensity- Modulated Radiation Therapy Planning

Purpose: To apply a statistical modeling approach, threshold modeling (TM), for quality control of intensity-modulated radiation therapy (IMRT) treatment plans. Methods: A quantitative measure, which was the weighted sum of violations of dose/dose-volume constraints, was first developed to represent the quality of each IMRT plan. Threshold modeling approach, which is is an extension of extreme value theory in statistics and is an effect way to model extreme values, was then applied to analyze the quality of the plans summarized by our quantitative measures. Our approach modeled the plans generated by planners as a series of independent and identically distributed random variables and described the behaviors of them if the plan quality was controlled below certain threshold. We tested our approach with five locally advanced head and neck cancer patients retrospectively. Two statistics were incorporated for numerical analysis: probability of quality improvement (PQI) of the plans and expected amount of improvement on the quantitative measure (EQI). Results: After clinical planners generated 15 plans for each patient, we applied our approach to obtain the PQI and EQI as if planners would generate additional 15 plans. For two of the patients, the PQI was significantly higher than the other three (0.17 and 0.18 comparing to 0.08, 0.01 and 0.01). The actual percentage of the additional 15 plans that outperformed the best of initial 15 plans was 20% and 27% comparing to 11%, 0% and 0%. EQI for the two potential patients were 34.5 and 32.9 and the rest of three patients were 9.9, 1.4 and 6.6. The actual improvements obtained were 28.3 and 20.5 comparing to 6.2, 0 and 0. Conclusion: TM is capable of reliably identifying the potential quality improvement of IMRT plans. It provides clinicians an effective tool to assess the trade-off between extra planning effort and achievable plan quality. This work was supported in part by NIH/NCI grant CA130814.

60 APPLIED LIFE SCIENCES↗

Mu2e straw tube tracker gas flow quality control

Here, we present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55 F source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening.

Flow↗

WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

60 APPLIED LIFE SCIENCES↗

Quality control of mislocalized and orphan proteins

A healthy and functional proteome is essential to cell physiology. However, this is constantly being challenged as most steps of protein metabolism are error-prone and changes in the physico-chemical environment can affect protein structure and function, thereby disrupting proteome homeostasis. Among a variety of potential mistakes, proteins can be targeted to incorrect compartments or subunits of protein complexes may fail to assemble properly with their partners, resulting in the formation of mislocalized and orphan proteins, respectively. Quality control systems are in place to handle these aberrant proteins, and to minimize their detrimental impact on cellular functions. Here, we discuss recent findings on quality control mechanisms handling mislocalized and orphan proteins. We highlight common principles involved in their recognition and summarize how accumulation of these aberrant molecules is associated with aging and disease.

60 APPLIED LIFE SCIENCES↗

FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

Abstract Summary FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. Availability and implementation FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc.

59 BASIC BIOLOGICAL SCIENCES↗

Quality control for community-based sea-ice model development

A new collaborative organization for sea-ice model development, the CICE Consortium, has devised quality control procedures to maintain the integrity of its numerical codes' physical representations, enabling broad participation from the scientific community in the Consortium's open software development environment. Using output from five coupled and uncoupled configurations of the Los Alamos Sea Ice Model, CICE, we formulate quality control methods that exploit common statistical properties of sea-ice thickness, and test for significant changes in model results in a computationally efficient manner. New additions and changes to CICE are graded into four categories, ranging from bit-for-bit amendments to significant, answer-changing upgrades. These modifications are assessed using criteria that account for the high level of autocorrelation in sea-ice time series, along with a quadratic skill metric that searches for hemispheric changes in model answers across an array of different CICE configurations. These metrics also provide objective guidance for assessing new physical representations and code functionality.

58 GEOSCIENCES↗

UR 2 : Ultra-rapid reactivity test for real-time, low-cost quality control of calcined clays

To reduce cement's carbon footprint, there is growing interest in commercial adoption of sustainable SCMs such as calcined clays. However, the existing ASTM standard (R 3 test, C1897) to test the reactivity of such clays takes up to 7 days and cannot be used for real-time quality control in an industrial setting. We address this issue by introducing a 5-min Ultra-Rapid Reactivity (UR 2 ) test. By dissolving 47 clay specimens in 4 M NaOH solutions at 90°C, we report that a dissolution index of 1.54Al + Si correlates strongly to the 7-day R 3 heat (R 2 = 0.92, RMSE = 94.1 J/g). This dissolution index also correlates to the 28-day compressive strength for 14 clay mixtures (R 2 = 0.94, RMSE = 1.7 MPa). This UR 2 test relies on colorimetry and can be conducted via off-the-shelf, low-cost cameras. Overall, our new UR 2 test opens a pathway for real-time, low-cost quality control of calcined clays.

36 MATERIALS SCIENCE↗

RACGAP1 modulates ECT2-Dependent mitochondrial quality control to drive breast cancer metastasis

Most cancer deaths are due to the colonization of tumor cells in distant organs. More evidence indicates that overexpression of RACGAP1 plays a critical role in cancer metastasis. However, the underlying mechanism still remains poorly understood. Here we found that RACGAP1 promoted breast cancer metastasis through regulating mitochondrial quality control. Overexpression of RACGAP1 in breast cancer cells led to the fragmentation of mitochondria, increased mitophagy intensity, mitochondrial turnover, and aerobic glycolysis ATP production. We showed that RACGAP1 promoted mitochondrial fission through recruiting ECT2 during anaphase and subsequently had activated ERK-DRP1 pathway. We further demonstrated the phosphorylation of RACGAP1 is essential for its ability of binding with ECT2 and its downstream effects. RACGAP1 overexpression also increased the expression of PGC-1a, a key mitochondrial biogenesis regulator, presumably by the increased mitophagy intensity induced by RACGAP1. PGC-1a increased the enrichment of DNMT1 in mitochondria, mitochondrial DNMT1 augmented mitochondrial DNA methylation and upregulated mitochondrial genome transcription. Our data indicated that RACGAP1 simultaneously facilitated mitophagy and mitochondrial biogenesis through regulating DRP1 phosphorylation and PGC-1a expression, eventually improved mitochondrial quality control in breast cancer cells. Our study provided a new angle in understanding the RACGAP1-overexpression related malignancy in breast cancer patients.

60 APPLIED LIFE SCIENCES↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Diameter Quality Control of Nb 3 Sn Wires for MQXF Cables in the USA

During this project, the 0.850 ± 0.003 mm Nb 3 Sn wires for the low-beta quadrupole magnets 'MQXFA' procured for the U.S. LHC Accelerator R&D Program (LARP) and the U.S. High Luminosity LHC Accelerator Upgrade Project (US HL-LHC AUP, or simply AUP) are received at Lawrence Berkeley National Laboratory (LBNL). There, the wires are respooled and then fabricated into Rutherford cables for winding coils. As part of the quality control program, AUP obtains from the wire manufacturer values of the maximum, average, minimum, and standard deviation of the two orthogonal axes, which are assessed prior to shipment approval. At LBNL, a dual-axis optical micrometer is used to measure the wire diameter of each spool every ~30 cm prior to cabling. This helps decide whether wire pieces with abnormal diameters should be distributed across the cable cross section, in order to improve cable parameter quality and mechanical stability consistency. This paper presents: 1) diameter data of LARP cables and of the first AUP cables made using wires acquired under LARP; 2) our deviation acceptance/rejection justification; and 3) the impact of wire diameter statistics on cable fabrication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FDA-ARGOS is a database with public quality-controlled reference genomes for diagnostic use and regulatory science

FDA proactively invests in tools to support innovation of emerging technologies, such as infectious disease next generation sequencing (ID-NGS). Here, we introduce FDA-ARGOS quality-controlled reference genomes as a public database for diagnostic purposes and demonstrate its utility on the example of two use cases. We provide quality control metrics for the FDA-ARGOS genomic database resource and outline the need for genome quality gap filling in the public domain. In the first use case, we show more accurate microbial identification of Enterococcus avium from metagenomic samples with FDA-ARGOS reference genomes compared to non-curated GenBank genomes. In the second use case, we demonstrate the utility of FDA-ARGOS reference genomes for Ebola virus target sequence comparison as part of a composite validation strategy for ID-NGS diagnostic tests. The use of FDA-ARGOS as an in silico target sequence comparator tool combined with representative clinical testing could reduce the burden for completing ID-NGS clinical trials

59 BASIC BIOLOGICAL SCIENCES↗

Ongoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151

Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.

60 APPLIED LIFE SCIENCES↗

Quality-Control Mechanism for Telomerase RNA Folding in the Cell

Long non-coding RNAs can often fold into different conformations. Telomerase RNA, an essential component of the telomerase ribonucleoprotein (RNP) enzyme, must fold into a defined structure to fulfill its function with the protein catalytic subunit (TERT) and other accessory factors. However, the mechanism by which the correct folding of telomerase RNA is warranted in a cell is still unknown. Here we show that La-related protein Pof8 specifically recognizes the conserved pseudoknot region of telomerase RNA and instructs the binding of the Lsm2-8 complex to its mature 3' end, thus selectively protecting the correctly folded RNA from exonucleolytic degradation. In the absence of Pof8, TERT assembles with misfolded RNA and produces little telomerase activity. Therefore, Pof8 plays a key role in telomerase RNA folding quality control, ensuring that TERT only assembles with functional telomerase RNA to form active telomerase. Our finding reveals a mechanism for non-coding RNA folding quality control.

59 BASIC BIOLOGICAL SCIENCES↗

Term Matrix: a novel Gene Ontology annotation quality control system based on ontology term co-annotation patterns

Biological processes are accomplished by the coordinated action of gene products. Gene products often participate in multiple processes, and can therefore be annotated to multiple Gene Ontology (GO) terms. Nevertheless, processes that are functionally, temporally and/or spatially distant may have few gene products in common, and co-annotation to unrelated processes probably reflects errors in literature curation, ontology structure or automated annotation pipelines. We have developed an annotation quality control workflow that uses rules based on mutually exclusive processes to detect annotation errors, based on and validated by case studies including the three we present here: fission yeast protein-coding gene annotations over time; annotations for cohesin complex subunits in human and model species; and annotations using a selected set of GO biological process terms in human and five model species. For each case study, we reviewed available GO annotations, identified pairs of biological processes which are unlikely to be correctly co-annotated to the same gene products (e.g. amino acid metabolism and cytokinesis), and traced erroneous annotations to their sources. To date we have generated 107 quality control rules, and corrected 289 manual annotations in eukaryotes and over 52 700 automatically propagated annotations across all taxa.

59 BASIC BIOLOGICAL SCIENCES↗

Cumulative sum quality control for calibrated breast density measurements

Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗