Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantum interference devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantum interference of currents in an atomtronic SQUID

Quantum interference of currents is the most important and well known quantum phenomenon in a conventional superconducting quantum interference device (SQUID). Here, we report the observation of quantum interference of currents in an atomtronic SQUID. Analogous to a conventional SQUID, currents flowing through two junctions in an atomtronic SQUID interfere due to the phase difference from rotation. This interference results in modulation of critical currents. This modulation was observed for three different radii with clear modulation periods which were measured to be consistent with fundamental rotation rates. This observation shows the possibility of studying various interesting SQUID physics with an atomtronic SQUID and especially, macroscopic quantum phenomena with currents may be realized with an atomtronic SQUID toward the goal of quantum metrology of rotation sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Type-I superconductor pick-up coil in superconducting quantum interference device-based ultra-low field nuclear magnetic resonance

In ultra-low field nuclear magnetic resonance (ULF-NMR) with strong prepolarization field (B{sub p}), type-II superconducting pick-up coils may be vulnerable to flux pinning from the strong B{sub p}. Pick-up coils made of NbTi, Nb, and Pb were evaluated in terms of acquired NMR signal quality. The type-II pick-up coils showed degraded signals above 61 mT maximum exposure, while the Pb pick-up coil exhibited no such degradation. Furthermore, a negative counter pulse following a strong B{sub p} was shown to follow magnetic hysteresis loop to unpin the trapped flux in the type-II pick-up coil and restore the NMR signal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerating the Deployment of Space-Based Quantum Sensors

Quantum sensors rely on quantum mechanical properties, such as wave-particle duality, atomic energy levels, or entanglement, to measure physical, optical, or electromagnetic information from a target. Examples include Rydberg sensors, nitrogen-vacancy magnetometers, HOM (Hong-Ou-Mandel) interferometers, and SQUIDs (Superconducting Quantum Interference Devices). In general, as quantum sensors rely on interrogation at the atomic and photonic level rather than on classical mechanical measurements, these technologies promise advantages over their traditional counterparts in sensitivity, accuracy, and SWaP (Size, Weight, and Power). Conceptually, the use of quantum sensors unlocks the new phenomenology of sensor entanglement. While an ultra-low TRL (Technology Readiness Level) prospect for most sensor types, multi-sensor entanglement is a high risk, high reward strategy with a potential for exquisite sensitivity and SWaP improvements entirely inaccessible to classical sensors.

Grace Caroline Wusk↗

Robust and symmetric magnetic field dependency of superconducting diode effect in asymmetric Dirac semimetal SQUIDs

The recent demonstration of the superconducting diode effect (SDE) has generated renewed interest in superconducting electronics, in which devices such as compact superconducting diodes that can perform signal rectification with low-energy operations are needed. In this article, we present our results of robust and symmetric-in-magnetic-field SDE in asymmetric superconducting quantum interference devices (SQUIDs) realized in high-quality Dirac semimetal Cd 3 As 2 thin film grown by the molecular beam epitaxy technique. Consistent with previous work, a zero magnetic field SDE is observed. Furthermore, the difference in switching current is independent of the strength and polarity of an out-plane magnetic field in the range of −10 and 10 mT. We speculate that this robust symmetric-in-field SDE in our Dirac semimetal SQUIDs is due to the formation of helical spin texture, theoretically predicted in Dirac semimetals.

Current-voltage characteristic↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

A New Small Nano-Kelvin Resolution Thermometer for Low Temperature Experiments

A small, high resolution paramagnetic susceptibility thermometer was developed using a GdCl3 paramagnetic salt. The device uses a SQUID (Superconducting Quantum Interference Device) magnetometer to determine the temperature dependent magnetization of the salt in a magnetic field. The magnetic field is provided by a pair of small samarium cobalt permanent magnet disks situated inside the thermometer housing. The eliminates the need for a heavy, charging solenoid used in a conventional SQUID based magnetic thermometer system. This thermometer can resolve approximately 10 (exp -9)K near the liquid-gas critical point of He-3(approximately 3.31K). The drift rate of the thermometer was measured to be less than 2 x 10 (exp -13) K per second. This light weight thermometer (approximately 7 g) is a candidate for use in future low temperature Space Shuttle and International Space Station experiments. The present thermometer design easily permits a variety of magnetic materials for use in other applications.

Welander, Paul↗

Exchange interactions of paramagnetic spins on α-Al 2 O 3

Superconducting qubits (SQs) represent a promising route to achieving a scalable quantum computer. However, the coupling between SQs and (as yet largely unidentified) parasitic noise sources has so far limited the functionality of current SQs by reducing the coherence time of the quantum states below a practical threshold for measurement and manipulation. These noise sources also more generally limit the performance of a variety of devices based on superconducting circuits, including high energy-resolution cryogenic radiation detectors, sensitive magnetic detectors (superconducting quantum interference devices, or SQUIDs), nanomechanical motion sensors and quantum-limited parametric amplifiers. In this paper, we study the origins of spin interactions on a substrate using OH on sapphire as a model system. We show how the substrate can mediate spin-spin interactions generally favoring FM interactions, but that strain can modify the interaction. Surface and sub-surface defects between the spin defects may also enhance the exchange interactions.

36 MATERIALS SCIENCE↗

Defect‐Free Nanowelding of Bilayer SnSe Nanoplates

Nanowelding is a bottom‐up technique to create custom‐designed nanostructures and devices beyond the precision of lithographic methods. Here, a new technique is reported based on anisotropic lubricity at the van der Waals interface between monolayer and bilayer SnSe nanoplates and a graphene substrate to achieve precise control of the crystal orientation and the interface during the welding process. As‐grown SnSe monolayer and bilayer nanoplates are commensurate with graphene's armchair direction but lack commensuration along graphene's zigzag direction, resulting in a reduced friction along that direction and a rail‐like, 1D movement that permits joining nanoplates with high precision. This way, molecular beam epitaxially grown SnSe nanoplates of lateral sizes 30–100 nm are manipulated by the tip of a scanning tunneling microscope at room temperature. In situ annealing is applied afterward to weld contacting nanoplates without atomic defects at the interface. This technique can be generalized to any van der Waals interfaces with anisotropic lubricity and is highly promising for the construction of complex quantum devices, such as field effect transistors, quantum interference devices, lateral tunneling junctions, and solid‐state qubits.

2D ferroelectrics↗

DNA-assembled superconducting 3D nanoscale architectures

Studies of nanoscale superconducting structures have revealed various physical phenomena and led to the development of a wide range of applications. Most of these studies concentrated on one- and two-dimensional structures due to the lack of approaches for creation of fully engineered three-dimensional (3D) nanostructures. Here, we present a ‘bottom-up’ method to create 3D superconducting nanostructures with prescribed multiscale organization using DNA-based self-assembly methods. We assemble 3D DNA superlattices from octahedral DNA frames with incorporated nanoparticles, through connecting frames at their vertices, which result in cubic superlattices with a 48 nm unit cell. The superconductive superlattice is formed by converting a DNA superlattice first into highly-structured 3D silica scaffold, to turn it from a soft and liquid-environment dependent macromolecular construction into a solid structure, following by its coating with superconducting niobium (Nb). Through low-temperature electrical characterization we demonstrate that this process creates 3D arrays of Josephson junctions. This approach may be utilized in development of a variety of applications such as 3D Superconducting Quantum interference Devices (SQUIDs) for measurement of the magnetic field vector, highly sensitive Superconducting Quantum Interference Filters (SQIFs), and parametric amplifiers for quantum information systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Infrared-Bolometer Arrays with Reflective Backshorts

Integrated circuits that incorporate square arrays of superconducting-transition- edge bolometers with optically reflective backshorts are being developed for use in image sensors in the spectral range from far infrared to millimeter wavelengths. To maximize the optical efficiency (and, thus, sensitivity) of such a sensor at a specific wavelength, resonant optical structures are created by placing the backshorts at a quarter wavelength behind the bolometer plane. The bolometer and backshort arrays are fabricated separately, then integrated to form a single unit denoted a backshort-under-grid (BUG) bolometer array. In a subsequent fabrication step, the BUG bolometer array is connected, by use of single-sided indium bump bonding, to a readout device that comprises mostly a superconducting quantum interference device (SQUID) multiplexer circuit. The resulting sensor unit comprising the BUG bolometer array and the readout device is operated at a temperature below 1 K. The concept of increasing optical efficiency by use of backshorts at a quarter wavelength behind the bolometers is not new. Instead, the novelty of the present development lies mainly in several features of the design of the BUG bolometer array and the fabrication sequence used to implement the design. Prior to joining with the backshort array, the bolometer array comprises, more specifically, a square grid of free-standing molybdenum/gold superconducting-transition-edge bolometer elements on a 1.4- m-thick top layer of silicon that is part of a silicon support frame made from a silicon-on-insulator wafer. The backshort array is fabricated separately as a frame structure that includes support beams and contains a correspond - ing grid of optically reflective patches on a single-crystal silicon substrate. The process used to fabricate the bolometer array includes standard patterning and etching steps that result in the formation of deep notches in the silicon support frame. These notches are designed to interlock with the support beams on the backshort-array structure to provide structural support and precise relative positioning. The backshort-array structure is inserted in the silicon support frame behind the bolometer array, and the notches in the frame serve to receive the support beams of the backshort-array structure and thus determine the distance between the backshort and bolometer planes. The depth of the notches and, thus, the distance between the backshort and bolometer planes, can be tailored to a value between 25 to 300 m adjusting only a few process steps. The backshort array is designed so as not to interfere with the placement of indium bumps for subsequent indium bump-bonding to the multiplexing readout circuitry

Miller, Timothy M.↗

Entanglement generation of nitrogen-vacancy centers via coupling to nanometer-sized resonators and a superconducting interference device

We present a potential scheme to entangle negatively charged nitrogen-vacancy (N-V) centers in distance using nanomechanical resonators (NAMRs) and a common superconducting quantum interference device (SQUID). By virtually exciting the vibrational modes of the NAMRs, we show the effective coupling between the N-V centers and the SQUID, which is a promising step toward large-sized quantum-information processing with separate N-V centers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magneto-Inductive Communications for Ocean Worlds

We propose a “magneto-inductive” technology, employing a sensitive receiver based on a Superconducting Quantum Interference Device (SQUID), to enable communications through conductive media, so as to pave the way for exploration of ocean worlds, especially a Europa scenario. Concepts for ice penetration systems to access the presumed liquid ocean on Europa are under development but it was previously considered impractical if not impossible to communicate through the briny ice with conventional propagating electromagnetic signals.

superconducting quantum interference device↗

Interface-driven magnetic anisotropy in relaxed La 0.7 Sr 0.3 CrO 3 /La 0.7 Sr 0.3 MnO 3 heterostructures on MgO

We investigate the structural and magnetic properties of La 0.7 Sr 0.3 CrO 3 /La 0.7 Sr 0.3 MnO 3 (LSMO) heterostructures grown on (001)-oriented MgO by molecular beam epitaxy. Due to the large film-substrate lattice mismatch, strain relaxation is found to occur within the first 2–3 unit cells (uc) of the film as evidenced by reflection high energy electron diffraction and high-resolution synchrotron x-ray reciprocal space mapping. Furthermore, we find that the presence of the LSCO spacer and capping layers leads to ferromagnetism in ultra-thin LSMO layers with thicknesses of the order of 2 uc with the magnetic easy axis oriented in the film plane. Net magnetic moments of 1.4 and 2.4 μ B /Mn are measured for (2 uc LSCO/2 uc LSMO) and (2 uc LSCO/4 uc LSMO) superlattices, respectively, by superconducting quantum interference device magnetometry. The effective magnetic anisotropy of the relaxed (2 uc LSCO/4 uc LSMO) heterostructure is found to be an order of magnitude higher than bulk LSMO highlighting the critical role of interfacial interactions in tuning magnetic anisotropy at complex oxide interfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flux-pumped impedance-engineered broadband Josephson parametric amplifier

Broadband quantum-limited amplifiers play a critical role in the single-shot readout of superconducting qubits, but a popular implementation, the traveling wave parametric amplifier, involves a complex design and fabrication process. Here, we present a simple design for a Josephson parametric amplifier, using a lumped element resonator comprising a superconducting quantum interference device whose useful bandwidth is enhanced with an on-chip impedance-matching circuit. Additionally, we demonstrate a flux-coupling geometry that maximizes the coupling to the Josepson loop and minimizes spurious excitation of the amplifier resonant circuit. The amplifier, which operates in a flux-pumped mode, is demonstrated with a power gain of more than 20dB over a bandwidth of about 300MHz, where approximate noise measurements indicate quantum-limited pehrformance. A procedure is given for optimizing the bandwidth for this kind of amplifier, using a linearized circuit simulation while minimizing non-linearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Growth, structural, and magnetic properties of single-crystal full-Heusler Co 2 TiGe thin films

This paper presents the growth, structural characterization, and measurement of magnetic properties of Co 2 TiGe thin films grown by molecular beam epitaxy on insulating MgO (001) substrates and conductive lattice matched InAlAs/InGaAs/InAlAs epitaxial layers grown on n-InP (001) substrates. A GdAs diffusion barrier was used to minimize interfacial reactions during Co 2 TiGe growth on InAlAs. The surface morphology, structural quality, and magnetic behavior were examined by reflection high-energy electron diffraction, scanning tunneling microscopy, X-ray diffraction, and superconducting quantum interference device magnetometry. The results reveal high quality Co 2 TiGe thin films with a saturation magnetization of ~1.8 μ B /formula unit and a Curie temperature of ~375 K. Finally, the magnetic easy axis was found to lie in the [110] direction but magnetometry also reveals that there is only a small difference in energy between the [110] and [010] magnetization directions.

36 MATERIALS SCIENCE↗