Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a Convolutional Neural Network Classifier for Data Starved Spectra - 20199

The Institute for Clean Energy Technology (ICET) at Mississippi State University is exploring the utility of machine learning in augmenting its mobile radiation surveying platforms, which are currently being developed as means to survey depleted uranium contaminated areas in support of remediation and decommissioning efforts. Mobile survey platforms provide a means to efficiently scan large areas of interest while reducing human exposure to radiation and other hazards. The survey platforms can also be used for scanning for any gamma emitting isotope in addition to depleted uranium. The spectral data that the platforms collect may be data starved with relatively low counts and poorly defined spectral features depending on the speed of the platforms and scintillation detector selection. Such data-starved spectra are difficult to use for isotope identification, requiring advanced knowledge of the possible radionuclides that could be present and environmental factors that could attenuate signals or introduce background noise. These factors in combination with the volume of survey data increases the time it takes to perform analysis of survey data when the source type is unknown. There are a number of algorithms in the field of machine learning that can be used to classify data that would be challenging and time-consuming for a human to identify. Supervised machine learning algorithms train models based on extensive amounts of human-labeled training data. Once sufficiently trained, these models can be used to quickly make high-fidelity predictions on new data. Convolutional neural networks are machine learning algorithms that excel in learning representations of 'shapes'. They do this by taking numerical input data and convolving them with spatial feature detectors referred to as filters. These filters are incrementally adjusted to reduce the prediction error on the data during the backpropagation step of training. Discussed in this paper is the development of a convolutional neural network classifier (CNNC) that can utilize spectral survey data for source discrimination and isotope identification. Bench-top laboratory experiments data using LaBr{sub 3}(Ce) scintillation detectors were used to train and evaluate the performance of the developed CNNC. The CNNC is capable of discriminating a variety of gamma emitting source types, differentiating different forms of uranium (depleted vs. natural), and estimating the amount of uranium for a known geometry. The discussed CNNC may be useful in scenarios where survey systems are deployed in situations where hazardous radioactive material maybe present, but the type is unknown. When used in remediation applications the CNNC can be used to screen-out false positives, helping reduce remediation costs. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Definitions for Testing Whether Evaluated Nuclear Data Relative Uncertainties are Realistic in Size

This document describes various tests that can be used to check whether evaluated relative uncertainties stored in nuclear-data covariances are realistic. To be more specific, these tests check whether nuclear-data uncertainties could be either over- or under-estimated given the input that usually enters the evaluation of nuclear-data mean values and covariances. Warning and error messages on the reliability of nuclear-data uncertainties will result from these tests. If uncertainties of one specific nuclear-data observable trigger warning messages from multiple tests, an evaluator should counter-check the reliability of the relative uncertainties of this particular nuclear-data covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response to Comment on “Radiation-Belt Remediation Using Space-Based Antennas and Electron Beams” by G. Ganguli and C. Crabtree

Ganguli and Crabtree have written a comment about a recent article by the authors listed above on radiation-belt remediation. They have objected to our evaluation of the Naval Research Laboratory’s chemical release concept which states that this concept may be impractical due to an apparently low overall efficiency. In their comment, they provide a scientific argument and refer to the published literature to counter our statement. Here, in this response, we provide more details on our numerical calculations and experimental results which led to this evaluation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Force-free Wave Interaction in Magnetar Magnetospheres: Computational Modeling in Axisymmetry

Abstract Crustal quakes of highly magnetized neutron stars can disrupt their magnetospheres, triggering energetic phenomena like X-ray and fast radio bursts. Understanding plasma wave dynamics in these extreme environments is vital for predicting energy transport across scales to the radiation length. This study models relativistic plasma wave interaction in magnetar magnetospheres with force-free electrodynamics simulations. For propagation along curved magnetic field lines, we observe the continuous conversion of Alfvén waves to fast magnetosonic (FMS) waves. The conversion efficiency can be up to three times higher when counter-propagating Alfvén waves interact in the equatorial region. Alfvén waves generate FMS waves of twice their frequency during their first crossing of the magnetosphere. After the initial transient burst of FMS waves, Alfvén waves convert to FMS waves periodically, generating variations on timescales of the magnetospheric Alfvén wave crossing time. This decaying FMS wave tail carries a significant portion (half) of the total energy emitted. Plastic damping of “bouncing” Alfvén waves by the magnetar crust has minimal impact on the FMS efficiency. We discuss the implications of the identified wave phenomena for magnetar observations. Outgoing FMS waves can develop electric zones, potential sources of coherent radiation. Long wavelength FMS waves could generate FRBs through reconnection beyond the light cylinder.

Astronomy & Astrophysics↗

Solar geoengineering may not prevent strong warming from direct effects of CO2 on stratocumulus cloud cover

Discussions of countering global warming with solar geoengineering assume that warming owing to rising greenhouse gas concentrations can be compensated by artificially reducing the amount of sunlight Earth absorbs. However, here we show that solar geoengineering may not be fail-safe to prevent global warming because CO2 has direct effects on cloud cover: it reduces cloud cover by modulating the longwave radiative cooling within the atmosphere, which is not mitigated by solar geoengineering. We use high-resolution simulations of clouds to show that under a sustained solar geoengineering scenario, the direct CO2 effects may lead to loss of subtropical stratocumulus clouds at concentrations above 1700~ppm. Because stratocumulus clouds cover large swaths of subtropical oceans and cool Earth by reflecting incident sunlight, their loss would trigger strong (about 5 K) global warming. Thus, the results highlight that, at least in an extreme scenario, solar geoengineering may be incapable to counter greenhouse-gas driven global warming.

Schneider, Tapio↗

Influence of uranyl complexation on the reaction kinetics of the dodecane radical cation with used nuclear fuel extraction ligands (TBP, DEHBA, and DEHiBA)

Specialized extractant ligands – such as tri-butyl phosphate (TBP), N,N-di-(2-ethylhexyl)butyramide (DEHBA), and N,N-di-2-ethylhexylisobutryamide (DEHiBA) – have been developed for the recovery of uranium from used nuclear fuel by reprocessing solvent extraction technologies. These ligands must function in the presence of an intense multi-component radiation field, and thus it is critical that their radiolytic behaviour be thoroughly evaluated. This is especially true for their metal complexes, where there is negligible information on the influence of complexation on radiolytic reactivity, despite the prevalence of metal complexes in used nuclear fuel reprocessing solvent systems. Here we present a kinetic investigation into the effect of uranyl (UO 2 2+ ) complexation on the reaction kinetics of the dodecane radical cation (RH˙ + ) with TBP, DEHBA, and DEHiBA. Complexation had negligible effect on the reaction of RH˙ + with TBP, for which a second-order rate coefficient (k) of (1.3 ± 0.1) × 10 10 M -1 s -1 was measured. For DEHBA and DEHiBA, UO 2 2+ complexation afforded an increase in their respective rate coefficients: k(RH˙ + + [UO 2 (NO 3 ) 2 (DEHBA) 2 ]) = (2.5 ± 0.1) × 10 10 M -1 s -1 and k(RH˙ + + [UO 2 (NO 3 ) 2 (DEHiBA) 2 ]) = (1.6 ± 0.1) × 10 10 M -1 s -1 . This enhancement with complexation is indicative of an alternative RH˙ + reaction pathway, which is more readily accessible for [UO 2 (NO 3 ) 2 (DEHBA) 2 ] as it exhibited a much larger kinetic enhancement than [UO 2 (NO 3 ) 2 (DEHiBA) 2 ], 2.6× vs. 1.4×, respectively. Complementary quantum mechanical calculations suggests that the difference in reaction kinetic enhancement between TBP and DEHBA/DEHiBA is attributed to a combination of reaction pathway (electron/hole transfer vs. proton transfer) energetics and electron density distribution, wherein attendant nitrate counter anions effectively ‘shield’ TBP from RH˙ + electron transfer processes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A short tutorial on uranium electropolishing

Electropolishing of uranium metal is best performed in a simple aqueous solution of phosphoric acid. With +3 to +10 volts of bias potential applied to the uranium (anode) relative to a Pt counter electrode (cathode). As summarized in a Pourbaix stability diagram, these conditions yield dissolution of the U surface as UOX containing solution species without the possibility of injecting hydrogen into the metal surface. However, if the uranium is biased to negative potentials relative to the counter electrode then water may be reduced at the U surface and hydrogen gas becomes available for reaction with the U metal. The stability diagram may be modified if there are other complexing species present in solution and the potential scale shifted if a different metal is use for the counter electrode. These effects can be understood in a known way as long as solution and electrochemical cell conditions are recognized.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Prototype for Unclassified Algorithm

Continuing previous efforts to investigate and develop the Unclassified Radioisotope Algorithm, the goal of the FY19-FY20 effort was to develop a prototype detector system which uses the algorithm to confirm warhead attributes related to the presence of either weapons grade plutonium (WGPu) or highly enriched uranium (HEU). The final deliverable is a prototype attribute measurement system built with common, commercially available gamma radiation detector components, capable of confirming the presence of specific, complex radioactive sources of interest, without the collection and storage of gamma energy spectra. This is accomplished by processing each gamma pulse as it is received, applying weight values based on the energy and incrementing or decrementing scalar counters which can be compared with expected values to determine if the measured source is consistent with WGPu or HEU. This report documents the design of the prototype system as well as the development of the algorithm and performance testing results. While the previously conceptualized, simple algorithm resulted in a prohibitive amount of false positives, the goal for a simple attribute measurement system capable of verifying Ba-133 and Ra-226 (weapons grade plutonium and highly enriched uranium surrogate testing sources) at over 95% accuracy with sub 5% false positive rate was demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Impacts of Neodymium Complexation on Radiolysis of Tetramethyl Diglycolamide (TMDGA) in Aqueous Solutions

Hydrophilic diglycolamides (DGA) ligands have been explored for use as stripping agents in various lanthanide and actinide partitioning processes.1 The separation of lanthanide fission products and transplutonic actinides can serve multifaceted advantages, in that the separation of neutron poisoning rare earth element (REE) fission products from the minor actinides in used nuclear fuel (UNF) can be mutually beneficial to the fundamental research behind REE separations and UNF separations. Considerable efforts have been devoted to understanding the radiation chemistry of hydrophilic DGAs. However, recent studies with lipophilic DGAs have shown that metal ion complexation can promote significant changes in their radiolytic susceptibility.2,3 These effects have been attributed to various parameters, including delocalization of electron density, the presence of radiolytically more susceptible counter ions, and steric hindrance. As such, it is pivotal for these complexation effects to be more thoroughly probed to establish mechanistic knowledge for their effects on hydrophilic DGA molecules. Here we present a time-resolved electron pulse and accumulated gamma dose irradiation study on neodymium ion complexes of tetramethyl diglycolamide (TMDGA) under aqueous solution conditions. References (1) Rostaing, C.; Poinssot, C.; Warin, D.; Baron, P.; Lorrain, B. Development and Validation of the EXAm Separation Process for Single Am Recycling. Procedia Chem. 2012, 7, 367–373. https://doi.org/doi: 10.1016/j.proche.2012.10.057. (2) Horne, G. P.; Conrad, J. K.; McLachlan, J. R.; Rotermund, B. M.; Cook, A. R.; Celis-Barros, C.; Mezyk, S. P. Impact of Lanthanide Complexation and Temperature on the Chemical Reactivity of N,N,N’,N’-Tetraoctyl Diglycolamide (TODGA) with the Dodecane Radical Cation. Phys. Chem. Chem. Phys. 2023, Under Review. (3) Kimberlin, A.; Saint-Louis, G.; Guillaumont, D.; Camès, B.; Guilbaud, P.; Berthon, L. Effect of Metal Complexation on Diglycolamide Radiolysis: A Comparison between Ex Situ Gamma and in Situ Alpha Irradiation. Phys. Chem. Chem. Phys. PCCP 2022, 24 (16), 9213–9228. https://doi.org/10.1039/d1cp05731f.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Development of a new CEDAR for kaon identification at the NA62 experiment at CERN

The NA62 experiment at CERN utilises a differential Cherenkov counter with achromatic ring focus (CEDAR) for tagging kaons within an unseparated monochromatic beam of charged hadrons. The CEDAR-H detector was developed to minimise the amount of material in the path of the beam by using hydrogen gas as the radiator medium. The detector was shown to satisfy the kaon tagging requirements in a test-beam before installation and commissioning at the experiment. The CEDAR-H performance was measured using NA62 data collected in 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cooling and instabilities in colliding radiative flows with toroidal magnetic fields

ABSTRACT We report on the results of a simulation-based study of colliding magnetized plasma flows. Our set-up mimics pulsed power laboratory astrophysical experiments but, with an appropriate frame change, is relevant to astrophysical jets with internal velocity variations. We track the evolution of the interaction region where the two flows collide. Cooling via radiative losses is included in the calculation. We systematically vary plasma beta (βm) in the flows, the strength of the cooling (Λ0), and the exponent (α) of temperature dependence of the cooling function. We find that for strong magnetic fields a counter-propagating jet called a ‘spine’ is driven by pressure from shocked toroidal fields. The spines eventually become unstable and break apart. We demonstrate how formation and evolution of the spines depend on initial flow parameters and provide a simple analytical model that captures the basic features of the flow.

79 ASTRONOMY AND ASTROPHYSICS↗