Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION FALL OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modeling the target dose fall-off in IMRT and VMAT planning techniques for cervical SBRT

There has been growing interest in the use of stereotactic body radiotherapy (SBRT) technique for the treatment of cervical cancer. The purpose of this study was to characterize dose distributions as well as model the target dose fall-off for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques using 6 and 10 MV photon beam energies. Fifteen (n = 15) patients with non-bulky cervical tumors were planned in Pinnacle{sup 3} with a Varian Novalis Tx (HD120 MLC) using 6 and 10 MV photons with the following techniques: (1) IMRT with 10 non-coplanar beams (2) dual, coplanar 358° VMAT arcs (4° spacing), and (3) triple, non-coplanar VMAT arcs. Treatment volumes and dose prescriptions were segmented according to University of Texas Southwestern (UTSW) Phase II study. All plans were normalized such that 98% of the planning target volume (PTV) received 28 Gy (4 fractions). For the PTV, the following metrics were evaluated: homogeneity index, conformity index, D{sub 2cc}, D{sub mean}, D{sub max}, and dose fall-off parameters. For the organs at risk (OARs), D{sub 2cc}, D{sub 15cc}, D{sub 0.01cc}, V{sub 20}, V{sub 40}, V{sub 50}, V{sub 60}, and V{sub 80} were evaluated for the bladder, bowel, femoral heads, rectum, and sigmoid. Statistical differences were evaluated using a Friedman test with a significance level of 0.05. To model dose fall-off, expanding 2-mm-thick concentric rings were created around the PTV, and doses were recorded. Statistically significant differences (p 3-arc , as compared with IMRT. VMAT{sub 3-arc} improved the bladder V{sub 40}, V{sub 50}, and V{sub 60}, and the bowel V{sub 20} and V{sub 50}. All fitted regressions had an R{sup 2} ≥ 0.98. For cervical SBRT plans, a VMAT{sub 3-arc} approach offers a steeper dose fall-off outside of the target volume. Faster dose fall-off was observed in smaller targets as opposed to medium and large targets, denoting that OAR sparing is dependent on target size. These improvements are further pronounced with the use of 10-MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Environmental Factors Associated With Fall Phytoplankton Blooms in the Northern Bering and Chukchi Seas

This study investigates environmental drivers of fall phytoplankton blooms in the Arctic, focusing on the northern Bering and Chukchi seas. Random Forests models were used to analyze covariates of fall phytoplankton blooms from 2013 to 2018, incorporating shipboard, remote sensing, and modeled environmental properties. Four regional models and one comprehensive all-station model considered fall as well as midsummer conditions. Midsummer properties included suspended particulate matter, chlorophyll-a, and the proportion of degraded pheophytin to chlorophyll-a used as a proxy for bloom stage. Open water duration was one of the highest ranked factors in predicting fall blooms. Open water duration also influences the stage of midsummer (July) blooms as indicated by pheophytin proportions, which in turn were the highest-ranked factor for predicting fall bloom events in the Chirikov Basin (northern Bering Sea between St. Lawrence Island and the Bering Strait) and the Chukchi Sea. Wind direction, specifically easterly winds, was an important predictor in the northern Bering Sea. Maximum wind speed ranked highly at stations located within the nutrient-poor Alaska Coastal Current in the Chukchi Sea. However, stormy days, average and maximum wind speeds generally ranked low in importance as a predictor of fall bloom events. Other parameters, including photosynthetic active radiation, modeled nutrient concentrations, mixed layer depth, and time since sea ice breakup date showed strong but regionally varying relationships with fall blooms. Altogether, results from these Random Forests models suggest that high wind events and storms in the absence of sea ice provide an incomplete narrative for initiating fall bloom events.

Gaffey, C. B. [Clark University, Worcester, MA (Un↗

Emission of the third continuum of argon excited by a pulsed volume discharge

This paper presents the results of the observation of the third continuum band at 190 nm in a pulsed volume discharge at an argon pressure of 0.17-2 bar. The spatial-time kinetics of ultraviolet-visible photorecombination continuum and the third continuum of argon were measured and analyzed for the high- and low-current excitation regimes. Time-resolved imaging experiments with an intensified charge coupled device camera have shown that the second continuum of argon at 127 nm, Ar* lines and photorecombination continuum had a uniform distribution across the positive column of the discharge. However, the third continuum and Ar{sup +}* lines were emitted exclusively from the negative glow zone. This indicates to the existence of runaway electrons, accelerated in the electric field of the cathode layer and retarded in the negative glow zone. These electrons can achieve the energy of the cathode fall potential (130-250 eV). The radiative decay of the Ar{sub 2}{sup 2+} ions, created from Ar{sup 2+} precursors, is modeled. A good agreement has been achieved between the calculated and measured kinetics of the third continuum at different pressures, which supports the assignment of this continuum to the emission of Ar{sub 2}{sup 2+} ions. In contrast to the third continuum, the origin of the afterglow emission bands at 190 and 260 nm are connected with carbon-containing contaminants, accumulated inside the discharge chamber. These bands were disappeared during the gas circulation through the getter purifier.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hydrodynamic Coupling to a Homogenized Radiation Transport Method based on Young Measures

Resolving radiation transport fields subject to opacity profiles with strong, oscillatory line structure while potentially falling under intermediate optical depth conditions presents a numerical challenge in radiation transport modeling. The Young measure-based homogenization technique formulated by Haut et al. (2017) was investigated as a candidate method for resolving radiation fields under such conditions more accurately. The method was compared against frequently-utilized mean opacity methods as the Rosseland and Planck formulations. In this work, all methods were tested through radiation slab calculations separately comprised of aluminum, copper, and krypton, each for different thermodynamic conditions. Following these offline radiation slab calculations, demonstrations shifted towards the SCEPTRE radiation transport code and, subsequently, the multiphysics ALEGRA code for approximately-coupled radiation-material simulations. Throughout all the simulations shown in this study, for a fixed computational cost, the homogenized method was observed to be more accurate than any of the solutions determined through traditional mean opacity approaches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The luminescence characteristics of CsI(Na) crystal under {alpha} and X/{gamma} excitation

In this paper, we study the effective decay time characteristic of CsI(Na) crystal under {sup 239}Pu alpha particle and {sup 137}Cs gamma-ray excitation using a single photon counting decay time measurement system. The measurement system employs a silicon optical fiber to couple and transit single photon. The slow decay time component of CsI(Na) crystal is 460-550 ns. We observe a 15 ns fast decay component under alpha particle excitation. In addition, we find that the primary stage of the falling edge in the decay time curve is non-exponential and drops rapidly when CsI(Na) crystal is excited by {sup 239}Pu alpha particles. Since the high density of self-trapped-excitons (STEs) is produced in alpha particle excitation process, we propose that the fast falling edge is corresponding to the quenching process of STEs which transit with non-radiation in the case of high excitation density. To prove this proposal, we excited the CsI(Na) crystal with sub-nanosecond intensive pulsed X-ray radiation. Our X-ray impinging results show that the fast falling edge also exists under low energy (average 100 keV) bremsstrahlung X-ray excitation.

36 MATERIALS SCIENCE↗

Radiation Therapy Infrastructure and Human Resources in Low- and Middle-Income Countries: Present Status and Projections for 2020

Purpose: Radiation therapy, a key component of cancer management, is required in more than half of new cancer patients, particularly in low- and middle-income countries (LMICs). The projected rise in cancer incidence over the next decades in LMICs will result in an increasing demand for radiation therapy services. Considering the present cancer incidence and that projected for 2020 (as listed in GLOBOCAN), we evaluated the current and anticipated needs for radiation therapy infrastructure and staffing by 2020 for each of the LMICs. Methods and Materials: Based on World Bank classification, 139 countries fall in the category of LMICs. Details of teletherapy, radiation oncologists, medical physicists, and radiation therapy technologists were available for 84 LMICs from the International Atomic Energy Agency–Directory of Radiotherapy Centres (IAEA-DIRAC) database. Present requirements and those for 2020 were estimated according to recommendations from the IAEA and European Society for Radiotherapy and Oncology (ESTRO-QUARTS). Results: Only 4 of the 139 LMICs have the requisite number of teletherapy units, and 55 (39.5%) have no radiation therapy facilities at present. Patient access to radiation therapy in the remaining 80 LMICs ranges from 2.3% to 98.8% (median: 36.7%). By 2020, these 84 LMICs would additionally need 9169 teletherapy units, 12,149 radiation oncologists, 9915 medical physicists, and 29,140 radiation therapy technologists. Moreover, de novo radiation therapy facilities would have to be considered for those with no services. Conclusions: Twelve pragmatic steps are proposed for consideration at national and international levels to narrow the gap in radiation therapy access. Multipronged and coordinated action from all national and international stakeholders is required to develop realistic strategies to curb this impending global crisis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding detachment of the W7-X island divertor

The fundamental behavior of the W7-X island divertor under detached conditions, which has been theoretically predicted with the EMC3-Eirene code, is re-examined here under the experimental conditions achieved so far and compared with the first experimental results. Both simulations and experiments cover a range of divertor configurations and plasma parameters, and show the following common trends: (1) with rising impurity radiation, the target heat load decreases 'uniformly' over the entire target surface in the sense that both the peak and average heat loads can drop by an order of magnitude. Impurity radiation (mainly from intrinsic carbon) occurs primarily at the plasma edge and the resulting negative impact on the stored energy is less than 10%. (2) When the total radiation exceeds a critical level, the target particle flux (the recycling flux Γrecy) begins to fall and can drop by a factor of 3–5 at high radiation levels without an obvious indication of significant volume recombination. (3) While Γ recy decreases, the divertor neutral pressure continues to build up and reaches a maximum, at which point Γ recy has declined significantly. (4) During detachment, the electron temperature at the last closed flux surface falls in a way that is not quantitatively understandable from parallel classical heat conduction processes. This paper presents a physical explanation of the numerical/experimental results described above. Furthermore, using the EMC3-Eirene code as a diagnostic tool, we are able, apparently for the first time, to provide a full quantitative analysis of each transport channel in the island divertor, aiming to clarify how the island divertor plasma self-regulates to maintain particle, energy, and momentum balance under detached conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Arctic observations and numerical simulations of surface wind effects on Multi-Angle Snowflake Camera measurements

Abstract. Ground-based measurements of frozen precipitation are heavily influenced by interactions of surface winds with gauge-shield geometry. The Multi-Angle Snowflake Camera (MASC), which photographs hydrometeors in free-fall from three different angles while simultaneously measuring their fall speed, has been used in the field at multiple midlatitude and polar locations both with and without wind shielding. Here, we present an analysis of Arctic field observations – with and without a Belfort double Alter shield – and compare the results to computational fluid dynamics (CFD) simulations of the airflow and corresponding particle trajectories around the unshielded MASC. MASC-measured fall speeds compare well with Ka-band Atmospheric Radiation Measurement (ARM) Zenith Radar (KAZR) mean Doppler velocities only when winds are light (≤5ms-1) and the MASC is shielded. MASC-measured fall speeds that do not match KAZR-measured velocities tend to fall below a threshold value that increases approximately linearly with wind speed but is generally <0.5ms-1. For those events with wind speeds ≤1.5ms-1, hydrometeors fall with an orientation angle mode of 12∘ from the horizontal plane, and large, low-density aggregates are as much as 5 times more likely to be observed. Simulations in the absence of a wind shield show a separation of flow at the upstream side of the instrument, with an upward velocity component just above the aperture, which decreases the mean particle fall speed by 55 % (74 %) for a wind speed of 5 m s−1 (10 m s−1). We conclude that accurate MASC observations of the microphysical, orientation, and fall speed characteristics of snow particles require shielding by a double wind fence and restriction of analysis to events where winds are light (≤5ms-1). Hydrometeors do not generally fall in still air, so adjustments to these properties' distributions within natural turbulence remain to be determined.

54 ENVIRONMENTAL SCIENCES↗

Third-order correlation function and ghost imaging of chaotic thermal light in the photon counting regime

In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is 6 times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Transition Radiation System for ATF2

In this paper we present the first measurements performed during the fall 2010 and early 2011 runs. Software development, simulations and hardware improvements to the Multi-Optical Transition Radiation System installed in the beam diagnostic section of the Extraction line of ATF2 are described. 2D emittance measurements have been performed and the system is being routinely used for coupling correction. Realistic beam simulations have been made and compared with the measurements. A demagnifier lens system to improve the beam finding procedure has been designed and will be implemented in a future run. We also discuss further work planned for the subsequent run periods.

43 PARTICLE ACCELERATORS↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transition radiation from relativistic electrons crossing a perfectly conducting conical surface: Calculation and experiment

The angular distributions of the transition radiation intensity when a charged particle passes through the vertex of a perfectly conducting conical surface have been calculated. The radiation generated both when the particle exits the conductor and when it falls on the conductor has been considered. The angular distributions of the intensity of the transition radiation generated by a bunch of relativistic electrons have been measured in the millimeter wavelength range. A microtron with a particle energy of 7.4 MeV was the source of electrons. The influence of the particle injection direction and the conical-surface opening angle on the angular distribution of the radiation intensity has been studied. The measurements have shown that the distribution of the radiation generated by a charge when it enters the horn differs significantly in pattern from the distribution when it exits the horn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser Disdrometer Quantities (LDQUANTS) and Video Disdrometer Quantities (VDISQUANTS) Value-Added Products Report

Disdrometers are useful instruments that measure the distribution of raindrop sizes (drop size distribution: DSD) and the associated rainfall rates/accumulation as those raindrops fall to the ground. These DSDs are a quantity of interest to members of the modeler and observational communities. However, use of disdrometer data for model evaluation, radar monitoring, or other activities requires careful quality control and processing for key DSD properties of interest (e.g., the number concentration of drops) to ensure appropriate physical (scattering, fall speed) assumptions. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Laser Disdrometer Quantities and Video Disdrometer Quantities Value-Added Product (LDQUANTS/VDISQUANTS VAP) uses standard methods from Tokay et al. (e.g., 2013, 2014) to filter drops with unrealistic fall speeds. Further, it estimates several microphysical/geophysical quantities of parameterized DSDs (gamma or exponential assumption type fitting methods) as in previous disdrometer studies and ARM long-term efforts (e.g., Testud et al. 2001, Giangrande et al. 2014, Thompson et al. 2015). Disdrometers are also beneficial for cross-checks with other instrumentation, including rain gauges and radars. To support research interests and related radar monitoring activities, this product calculates radar equivalent quantities, including dual polarization radar quantities (e.g., Z, Differential Reflectivity ZDR, etc.), using T-Matrix scattering and additional wavelength, temperature, and drop shape assumptions (e.g., Thurai et al. 2007). All of these efforts allow disdrometer data sets to become more useful and easily handled by modeling and observational studies, or routine instrumentation checks.

47 OTHER INSTRUMENTATION↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Multiphase Modeling in a Parallel Plate Fluidized Bed Receiver for Concentrating Solar Power

A novel high temperature particle solar receiver is developed by using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a packed bed at the lower end, leaving the system from the bottom at a constant flow rate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built and a near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2K.

CSP↗

Approaches to attributing underwater noise to a wave energy converter

Radiated noise from marine energy harvesting is of environmental and engineering interest. Here, drifting hydrophones measure underwater noise in the vicinity of a relatively small wave energy converter. A statistical approach is demonstrated for attributing range-dependent, commonly occurring sounds in the frequency band from 90 to 600 Hz. Time-delay-of-arrival localization is then demonstrated for attribution of individual acoustic events likely associated with the power takeoff and wave-hull interactions. Because the radiated noise from the wave energy converter falls below ambient levels at a range of approximately 150 m, it is unlikely to substantially affect marine life at greater distance.

16 TIDAL AND WAVE POWER↗

Sample Management Tools for the Irradiation Test Area (ITA)

The ITA offers onsite radiation testing, and will be available starting Fall 2020. It is projected to have testing slots about 40x/year and a capacity to reach fluences of 1016 protons/cm2 in four hours. A 400 MeV proton beam is directed to samples in a concrete shielding cave, with variations in place available to the user’s preferences. The ITA regulates all its experiment data through ITA’s Data Manager (IDM).

43 PARTICLE ACCELERATORS↗

The signature of the central engine in the weakest relativistic explosions: GRB 100316D

We present late-time radio and X-ray observations of the nearby sub-energetic gamma-ray burst (GRB)100316D associated with supernova (SN) 2010bh. Our broad-band analysis constrains the explosion properties of GRB 100316D to be intermediate between highly relativistic, collimated GRBs and the spherical, ordinary hydrogen-stripped SNe. We find that ∼10{sup 49} erg is coupled to mildly relativistic (Γ = 1.5-2), quasi-spherical ejecta, expanding into a medium previously shaped by the progenitor mass-loss with a rate of M-dot ∼ 10{sup −5} M{sub ⊙} yr{sup −1} (for an assumed wind density profile and wind velocity v{sub w} = 1000 km s{sup –1}). The kinetic energy profile of the ejecta argues for the presence of a central engine and identifies GRB 100316D as one of the weakest central-engine-driven explosions detected to date. Emission from the central engine is responsible for an excess of soft X-ray radiation that dominates over the standard afterglow at late times (t > 10 days). We connect this phenomenology with the birth of the most rapidly rotating magnetars. Alternatively, accretion onto a newly formed black hole might explain the excess of radiation. However, significant departure from the standard fall-back scenario is required.

79 ASTRONOMY AND ASTROPHYSICS↗