Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION PYROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

69 records · Page 4

Thermal Control in Hypersonic Leading Edges Using Liquid Metal High Temperature Oscillating Heat Pipes

The desire to increase the range and speed of hypersonic vehicles requires sharp, shape-stable Wing Leading Edges (WLE) with performance capabilities well beyond the current state of the art. The concentrated heat flux on sharp leading edges can lead to runaway thermal and mechanical failures. Heat pipes provide a passive solution to minimize the peak temperature, thermal gradients, and resulting thermal stresses near the WLE. Conventional heat pipes have been shown to address these issues at conditions as high as Mach 8. Oscillating heat pipes (OHPs) could be used to extend this benefit to missions with higher Mach numbers since their heat transport capacity typically exceeds that of conventional heat pipes. In the current investigation, several identical liquid metal high-temperature oscillating heat pipes (LMHOHPs) were constructed and tested to demonstrate the concept. The LMHOHPs had six turns, internal diameters of 2 mm, and total lengths of 100 mm. They were additively manufactured from C103 niobium alloy and charged with lithium to reach a fill ratio of approximately 50%. The boundary conditions of the experiment were designed to resemble those of various hypersonic flight profiles. Testing was performed with a system consisting of flow-controlled acetylene torch heating and radiation dominated heat rejection. The LMHOHP’s performance was measured using temperature data from an infrared camera and pyrometer. The experimental results were used to evaluate the capability of C103/lithium LMHOHPs under various flight regimes. A heat transfer model of the LMHOHP was proposed and validated against test data. Insights from the model were then extrapolated to evaluate a Tungsten-RHC/Gallium LMHOHP with anticipated capabilities beyond that of the C103/lithium system.

Max Pawlick↗

Pyrometry Without Spurious Reflections

Temperature of heated spherical specimen of opaque material with specular surface measured by optical pyrometry, without need to correct for effect of reflected thermal radiation upon measured radiances, provided reflections eliminated. To prevent unwanted reflections, apparatus must be arranged so field of view of pyrometer does not contain any lines of sight to image of wall. Particularly useful for making accurate noncontact measurements of levitated specimens of molten metal and other materials in containerless processing.

Thomas, Andrew S. W.↗

Infrared shield facilitates optical pyrometer measurements

Water-cooled shield facilitates optical pyrometer high temperature measurements of small sheet metal specimens subjected to tensile stress in fatigue tests. The shield excludes direct or reflected radiation from one face of the specimen and permits viewing of the infrared radiation only.

Eichenbrenner, F. F.↗

Thermal Conductivity of Ceramic Thermal Barrier and Environmental Barrier Coating Materials

Thermal barrier and environmental barrier coatings (TBC's and EBC's) have been developed to protect metallic and Si-based ceramic components in gas turbine engines from high temperature attack. Zirconia-yttria based oxides and (Ba,Sr)Al2Si2O8(BSAS)/mullite based silicates have been used as the coating materials. In this study, thermal conductivity values of zirconia-yttria- and BSAS/mullite-based coating materials were determined at high temperatures using a steady-state laser heat flux technique. During the laser conductivity test, the specimen surface was heated by delivering uniformly distributed heat flux from a high power laser. One-dimensional steady-state heating was achieved by using thin disk specimen configuration (25.4 mm diam and 2 to 4 mm thickness) and the appropriate backside air-cooling. The temperature gradient across the specimen thickness was carefully measured by two surface and backside pyrometers. The thermal conductivity values were thus determined as a function of temperature based on the 1-D heat transfer equation. The radiation heat loss and laser absorption corrections of the materials were considered in the conductivity measurements. The effects of specimen porosity and sintering on measured conductivity values were also evaluated.

Zhu, Dong-Ming↗

Wedge Heat-Flux Indicators for Flash Thermography

Wedge indicators have been proposed for measuring thermal radiation that impinges on specimens illuminated by flash lamps for thermographic inspection. Heat fluxes measured by use of these indicators would be used, along with known thermal, radiative, and geometric properties of the specimens, to estimate peak flash temperatures on the specimen surfaces. These indicators would be inexpensive alternatives to high-speed infrared pyrometers, which would otherwise be needed for measuring peak flash surface temperatures. The wedge is made from any suitable homogenous material such as plastic. The choice of material is governed by the equation given. One side of the wedge is covered by a temperature sensitive compound that decomposes irreversibly when its temperature exceeds a rated temperature (T-rated). The uncoated side would be positioned alongside or in place of the specimen and exposed to the flash, then the wedge thickness at the boundary between the white and blackened portions measured.

Koshti, Ajay M.↗

Optical Sensor Of High Gas Temperatures

Contact pyrometer resists effects of heat, vibration, and moisture. New sensor consists of shielded sapphire rod with sputtered layer of precious metal on end. Metal layer acts as blackbody. Emits radiation having known dependence of spectral distribution with temperature of metal and temperature of hot gas flowing over metal. Fiber-optic cable carries radiation from sapphire rod to remote photodetector.

Hill, Arthur J.↗

High-Resolution, Two-Wavelength Pyrometer

Modified two-color pyrometer measures temperatures of objects with high spatial resolution. Image focused on hole 0.002 in. (0.05 mm) in diameter in brass sheet near end of bundle, causing image to be distributed so fibers covered by defocused radiation from target. Pinhole ensures radiation from only small part of target scene reaches detector, thus providing required spatial resolution. By spreading radiation over bundle, pinhole ensures entire active area of detectors utilized. Produces signal as quiet as conventional instruments but with only 1/64 input radiation.

Bickler, Donald B.↗

Remote Heat Flux Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material

A self calibrating multiwavelength pyrometer was used to conduct remote heat flux measurements using a transparent sapphire disk by determining the sapphire disk's front and back surface temperatures. Front surface temperature (Tfs) was obtained from detection of surface emitted radiation at long wavelengths (k = 6 gm). Back surface temperature (Tbs) was obtained from short wavelength (1 to 5 gm) radiation transmitted through the sapphire disk. The thermal conductivity of the sapphire disk and the heat transfer coefficients h, and h2 of its surfaces are determined experimentally. An analysis of the heat flux measurement is presented.

Ng, Daniel↗

Remote Heat Flux Measurement Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material

A self calibrating multiwavelength pyrometer was used to conduct remote heat flux measurements using a transparent sapphire disk by determining the sapphire disk's front and back surface temperatures. Front surface temperature (Tfs) was obtained from detection of surface emitted radiation at long wavelengths (lambda > 6 micrometers). Back surface temperature (Tbs) was obtained from short wavelength (1 to 5 micrometers) radiation transmitted through the sapphire disk. The thermal conductivity k of the sapphire disk and the heat transfer coefficients h(sub 1) and h(sub 2) of its surfaces are determined experimentally. An analysis of the heat flux measurement is presented.

Ng, Daniel↗

Temperature Distributions in Hollow Cathode Emitters

Life-limiting processes in hollow cathodes are determined largely by the temperature of the emitter. To support development of cathode life models we have developed a noncontact temperature measurement technique which employs a stepper motor-driven fiber optic probe. The probe is driven inside the hollow cathode and collects light radiated by the hot interior surface of the emitter. Ratio pyrometry is used determine the axial temperature profile. Thermocouples on the orifice plate provide measurements ofthe external temperature during cathode operation and are used to calibrate the pyrometer system in situ with a small oven enclosing the externally heated cathode. Initial measurements of the temperature distribution in a hollow cathode with the same geometry as a cathode that failed after operating at 12 A emission current for 27800 hours are discussed.

ratio pyrometer system↗

TPSAS-NF1676L-33668-DND

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of the camera lens allows separate 2D images to be obtained at three different wavelengths. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, a sooting butane flame and a luminous sulfur match flame. The images were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument could measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D measurements of the radiation heater, flame and match are shown.

Paul M Danehy↗

A cooled-gas pyrometer for use in hypersonic engine testing

A cooled-gas pyrometer designed for application in a hypersonic research engine program was fabricated and tested. Design and operational considerations and calibration data are presented. The probe was tested in a rocket-engine exhaust stream operating at Mach 2 and 2300 K. Test temperature measurements agreed to within 2 percent with a radiation shielded thermocouple probe.

Glawe, G. E.↗

A Plenoptic Multi-Color Imaging Pyrometer

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of a camera lens allow separate 2D images to be obtained on a single image sensor at three different and adjustable wavelengths selected by the user. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, and a luminous sulfur match flame. The images obtained of the calibration furnace and radiation heater were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument can measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D temperature measurements of the radiation heater are shown.

Danehy, Paul M.↗

Directional spectral emissivity measurement system

Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

Halyo, Nesim↗

Radiation Effects in a Semitransparent Gray Coating Heated by Convection and Cooled by Radiation

A parametric study using a one dimensional model of a semitransparent gray thermal barrier coating was performed to gain an understanding of the role thermal radiation can play in the heat transferred. Some ceramic materials are semitransparent in the wavelength ranges were thermal radiation is important. Therefore, absorption, emission, and scattering of thermal radiation can affect the he at transfer through the coating. In this paper, a one dimensional layer was used to model the heat transfer process occurring, in a burner test rig. The semitransparent layer is heated by a hot gas flowing over its surface. The layer and substrate at a cooled by radiation to the surroundings. The back side of the substrate is insulated. The coating is assumed to be gray (absorption and scattering coefficients are not function of wavelength). An absorption coefficient of 0.3/cm and scatter a rig coefficients of 0 (no scattering) and 100/cm (isotropic scattering) were used. The thickness and thermal conductivity of the layer are varied. The results show that the temperatures are affected by the properties of the semitransparent .ever and the emissivity of the substrate. The substrate and surface temperatures are presented. The apparent temperature an optical pyrometer would read for the emitted energy is also given. An apparent thermal conductivity was calculated for the layer.

Spuckler, Charles M.↗