Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Low-Tech, Low-Budget Storage Solution for High Level Radioactive Sources

The need for safe, secure, and economical storage of radioactive material becomes increasingly important as beneficial uses of radioactive material expand (increases inventory), as political instability rises (increases threat), and as final disposal and treatment facilities are delayed (increases inventory and storage duration). Several vendor-produced storage casks are available for this purpose but are often costly — due to the required design, analyses, and licensing costs. Thus the relatively high costs of currently accepted storage solutions may inhibit substantial improvements in safety and security that might otherwise be achieved. This is particularly true in areas of the world where the economic and/or the regulatory infrastructure may not provide the means and/or the justification for such an expense. This paper considers a relatively low-cost, low-technology radioactive material storage solution. The basic concept consists of a simple shielded storage container that can be fabricated locally using a steel pipe and a corrugated steel culvert as forms enclosing a concrete annulus. Benefits of such a system include 1) a low-tech solution that utilizes materials and skills available virtually anywhere in the world, 2) a readily scalable design that easily adapts to specific needs such as the geometry and radioactivity of the source term material), 3) flexible placement allows for free-standing above-ground or in-ground (i.e., below grade or bermed) installation, 4) the ability for future relocation without direct handling of sources, and 5) a long operational lifetime . ‘Le mieux est l’ennemi du bien’ (translated: The best is the enemy of good) applies to the management of radioactive materials – particularly where the economic and/or regulatory justification for additional investment is lacking. Development of a low-cost alternative that considerably enhances safety and security may lead to a greater overall risk reduction than insisting on solutions that remain economically and/or politically ‘out of reach’.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Securing the metal recycling chain for the steel industry by detecting orphan radioactive sources in scrap metal

Experimental tests are reported for the detection of the heavy metal shielding of orphan sources hidden inside scrap metal by using a recently developed muon tomography system. Shielded sources do not trigger alarm in radiation portal commonly employed at the entrance of steel industry using scrap metal. Future systems integrating radiation portals with muon tomography inspection gates will substantially reduce the possibility of accidental melting of radioactive sources securing the use of recycled metal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small-angle Compton Scattering to Determine the Depth of a Radioactive Source in Matter

A gamma-ray peak in a spectrum is often accompanied by a discontinuity in the Compton continuum at the peak. The Compton continuum results from Compton scattering in the detector. The discontinuity at a peak results from small-angle Compton scattering by the gamma rays in matter situated directly between the gamma-ray source and the detector. The magnitude of this discontinuity with respect to the gamma-ray peak is therefore an indicator of the amount of material or shielding between the gamma-ray source and the detector. This small-angle scattering was used to determine the depth of highly-enriched uranium (HEU) solution standards in a concrete floor mockup. The empirical results of the use of this small-angle scattering discontinuity in a concrete floor experiment will be described. A Monte Carlo calculation of the experiment will also be described. In addition, the depth determined from small-angle scattering was used in conjunction with differential attenuation to more accurately measure the uranium content of the mockup. Following these empirical results, the theory of small-angle scattering will be discussed. The magnitude of the discontinuity compared to the peak count rate is directly related to the depth of the gamma-ray source in matter. This relation can be described by relatively simple mathematical expressions. This is the first instance that we are aware of in which the small-angle Compton scattering has been used to determine the depth of a radioactive source. Furthermore this is the first development of the theoretical expressions for the magnitude of the small-angle scattering discontinuity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tracking of moving radioactive sources

A system for detecting unsecured nuclear materials. Whereas current portal monitors rely in part on physical prominence to deter materials from entering the country, their application at intra-modal transport points may actually serve to divert the movement of nuclear materials rather than aid in interception. A flexible and low-profile system has been developed for unobtrusive detection and tracking of radioactive sources in transit suited for deployment at traffic choke points such as rest stops, toll collection plazas, truck stops, and bridges. The system includes gamma radiation detectors, networking for linking these detectors, signal processing algorithms, and a central processing and control unit.

Klann, Raymond↗

Calibration of a time-resolved hard-x-ray detector using radioactive sources

A four-channel, time-resolved, hard x-ray detector (HXRD) has been operating at the Laboratory for Laser Energetics for more than a decade. The slope temperature of the hot-electron population in direct-drive inertial confinement fusion experiments is inferred by recording the hard x-ray radiation generated in the interaction of the electrons with the target. Measuring the energy deposited by hot electrons requires an absolute calibration of the hard x-ray detector. A novel method to obtain an absolute calibration of the HXRD using single photons from radioactive sources was developed, which uses a thermoelectrically cooled, low-noise, charge-sensitive amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics

The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a $^{60}$Co radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Lastly we describe the instrumentation details and the operational experiences related to the sourcing test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National nuclear forensics libraries: a case study on benefits and possibilities for identification of sealed radioactive sources

A National Nuclear Forensic Library (NNFL) is a useful nuclear forensics tool which consists of information and subject matter expertise on radioactive and nuclear (RN) materials produced, used or stored within a State. If RN material is found out of regulatory control the NNFL can be used as part of a nuclear forensics investigation to help identify whether or not the material is consistent with a country’s national holdings. In previous work, a number of signatures which can be useful to identify sealed sources of 241 Am were investigated. To validate the measurement results, an official query concerning information about two of the previously investigated 241 Am sources was sent to the United States Department of State, the international point-of-contact (POC) for the U.S. NNFL. The aim of this work is to show how data obtained in a characterization of a radioactive source can be used in conjunction with an NNFL to investigate the history of a source out of regulatory control.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Burnup estimation of fuel sourcing radioactive material based on monitored Cs and Pu isotopic activity ratios in Fukushima N. P. S. accident

After the severe core damage of Fukushima Dai-Ichi Nuclear Power Station, radioactive material leaked from the reactor buildings. As part of monitoring of radioactivity in the site, measurements of radioactivity in soils at three fixed points have been performed for {sup 134}Cs and {sup 137}Cs with gamma-ray spectrometry and for Pu, Pu, and {sup 240}Pu with {alpha}-ray spectrometry. Correlations of radioactivity ratios of {sup 134}Cs to {sup 137}Cs, and {sup 238}Pu to the sum of {sup 239}Pu and {sup 240}Pu with fuel burnup were studied by using theoretical burnup calculations and measurements on isotopic inventories, and compared with the Cs and Pu radioactivity rations in the soils. The comparison indicated that the burnup of the fuel sourcing the radioactivity was from 18 to 38 GWd/t, which corresponded to that of the fuel in the highest power and, therefore, the highest decay heat in operating high-burnup fueled BWR cores. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non Accountable Sealed Radioactive Sources

Presentation describes investigation into defective 10 uCi Cs-137 "button" sources and response to potential contamination, to include radiological control measures, notifications, and awareness reports. Effort involves benchmarking of EFCOG member processes for use and handling of non-accountable sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

FOSTERING MULTI-LATERAL COOPERATION BETWEEN THE GOVERNMENTS OF DOMINICAN REPUBLIC, COLOMBIA, AND THE UNITED STATES TO ENHANCE THE PROTECTION OF HIGH-ACTIVITY RADIOACTIVE SOURCES

The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide from sabotage, theft or diversion. The GTRI has worked successfully with foreign countries to remove and protect nuclear and radioactive materials including high-activity sources used in medical, commercial, and research applications. There are many barriers to successful bilateral cooperation that must be overcome including language, preconceived perceptions, long distances, and different views on the threat and protection requirements. Successful cooperation is often based on relationships and building trusting relationships takes time. In the case of Dominican Republic, the GTRI first received contact in 2008 from the Government of Dominican Republic. They requested cooperation that was similar to the tri-partite cooperation between Colombia, Mexico and the United States. Throughout the region it was widely known that the GTRI’s cooperation with the Government of Colombia was a resounding success resulting in the securing of forty sites; the consolidation of numerous disused/orphan sources at a secure national storage facility; and, the development of a comprehensive approach to security including, inter alia, training and sustainability. The Government of Colombia also showcased this comprehensive approach to thirteen Central American and Caribbean countries at a GTRI regional security conference held in Panama in October 2004. In 2007, Colombia was an integral component of GTRI multi-lateral cooperation initiation in Mexico. As a result, twenty two of Mexico’s largest radioactive sites have been upgraded in the past eighteen months. These two endeavors served as catalysts for cooperation opportunities in the Dominican Republic. Representatives from the Colombian government were aware of GTRI’s interest in initiating cooperation with the Government of Dominican Republic and to facilitate this cooperation, they traveled to the Dominican Republic and provided briefings and presentations which demonstrated its successful cooperation with the GTRI. Shortly after that visit, the Government of Dominican Republic agreed to move forward and requested that the cooperative efforts in Dominican Republic be performed in a tripartite manner, leveraging the skills, experience, and resources of the Colombians, and the financial and technical support of the United States. As a result, two of Dominican Republic’s largest radioactive sites had security upgrades in place within 90 days of the cooperation visit in December 2008.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FOSTERING MULTI-LATERAL COOPERATION BETWEEN THE GOVERNMENTS OF MEXICO, COLOMBIA, AND THE UNITED STATES TO ENHANCE THE PROTECTION OF HIGH-ACTIVITY RADIOACTIVE SOURCES

The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide from sabotage, theft or diversion. The GTRI program has worked successfully with foreign countries to remove and protect nuclear and radioactive materials including high-activity sources used in medical, commercial, and research applications. There are many barriers to successful bilateral cooperation that must be overcome including language, preconceived perceptions, long distances, and different views on the threat and protection requirements. Successful cooperation is often based on relationships and building trusting relationships takes time. In the case of Mexico, GTRI first made contact in 2005. The project then lost momentum and stalled. At the same time, GTRI’s cooperation with the Republic of Colombia was a resounding success resulting in the securing of forty sites; the consolidation of numerous disused/orphan sources at a secure national storage facility; and, the development of a comprehensive approach to security including, inter alia, training and sustainability. The government of Colombia also showcased this comprehensive approach to thirteen Central American and Caribbean countries at a GTRI regional security conference held in Panama in October 2004. Representatives from the Colombian government were aware of GTRI’s interest in initiating cooperation with the Government of Mexico and to facilitate this cooperation, they offered to invite their Mexican counterparts to Colombia to observe its successful cooperation with GTRI. Shortly after that visit, the Government of Mexico agreed to move forward and requested that the cooperative efforts in Mexico be performed in a tripartite manner, leveraging the skills, experience, and resources of the Colombians. As a result, 22 of Mexico’s largest radioactive sites have had security upgrades in place within 18 months of cooperation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LATIN AMERICAN AND CARIBBEAN WORKSHOP ON THE SUSTAINABILITY OF RADIOACTIVE SOURCE PHYSICAL PROTECTION UPGRADES HOSTED IN GUATEMALA

The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide. The GTRI program has worked successfully to remove and protect nuclear and radioactive materials, including orphaned and disused high-activity sources, and is now working to ensure sustainability. Internationally, over 40 countries are cooperating with GTRI to enhance the security of radiological materials. GTRI is now seeking to develop and enhance sustainability by coordinating its resources with those of the partner country, other donor countries, and international organizations such as the International Atomic Energy Agency (IAEA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CENTRAL STORAGE FACILITY PROJECT IN COLOMBIA TO PROVIDE THE SAFE STORAGE AND PROTECTION OF HIGH-ACTIVITY RADIOACTIVE SOURCES

The Global Threat Reduction Initiative (GTRI) reduces and protects vulnerable nuclear and radiological material located at civilian sites worldwide. Internationally, over 40 countries are cooperating with GTRI to enhance the security of these materials. The GTRI program has worked successfully with foreign countries to remove and protect nuclear and radioactive materials, including orphaned and disused high-activity sources. GTRI began cooperation with the Republic of Colombia in April 2004. This cooperation has been a resounding success by securing forty high-risk sites, consolidating disused/orphan sources at an interim secure national storage facility, and developing a comprehensive approach to security, training, and sustainability. In 2005 the Colombian Ministry of Mines and Energy requested the Department of Energy’s support in the construction of a new Central Storage Facility (CSF). In December 2005, the Ministry selected to construct this facility at the Institute of Geology and Mining (Ingeominas) site in Bogota. This site already served as Colombia’s national repository, where disused sources were housed in various buildings around the complex. The CSF project was placed under contract in May 2006, but environmental issues and public protests, which led to a class action lawsuit against the Colombian Government, forced the Ministry to quickly suspend activities, thereby placing the project in jeopardy. Despite these challenges, however, the Ministry of Mines and Energy worked closely with public and environmental authorities to resolve these issues, and continued to be a strong advocate of the GTRI program. In June 2008, the Ministry of Mines and Energy was granted the construction and environmental licenses. As a result, construction immediately resumed and the CSF was completed by December 2008. A commissioning ceremony was held for the new facility in January 2009, which was attended by representatives from the Department of Energy, U.S. Embassy, and the Ministry of Mines and Energy, including the Minister and Vice Minister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Small Radioactive Source in a Large Media - Localization by Multi-detector Measurement. The Case of a Lung Counter

Considerable errors in the determination of radioactive contamination in lungs can be induced if there is no homogeneous distribution, as assumed for the calibration. Modern lung counter systems use several detectors, and the count rate ratios of the detectors can be used for localization of the radioactive contamination, enabling the use of correction algorithms. This greatly reduces the errors in the determination of the activity. Further reduction of the errors can be obtained by simultaneous analysis of several gamma lines (if several energies are emitted by the radioisotope), and by optimizing the number and location of the detectors. This presentation deals with the case of a point source of natural uranium in human lungs.

07 ISOTOPE AND RADIATION SOURCES↗

Proposal of a Categorization of the Disused Sealed Radioactive Sources with a View to Safe - 17285

In the Nuclear and Energy Research Institute (IPEN-CNEN/Brazil) many works to improve and develop characterization of radioactive waste techniques have been deployed by the Radioactive Waste Management Department (IPEN-CNEN/SP). In this line, this work aims to suggest a new categorization of sealed sources, which considers their activities, as suggested by the International Atomic Energy Agency (IAEA), but also the time required for the activity to decrease to a safe value. We considered the sealed sources categorization system suggested by the IAEA and we applied such categorization system to various sources currently stored by institutes of Brazilian Nuclear and Energy Commission (CNEN). Then, we also applied the categorization system defined herein, it follows that the categorization system presented by the IAEA has many applications and their use should not be abandoned. However, since the new proposed categorization systems allow to differentiate sources that in the IAEA system are in the same category, they can help define the long-term management of radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Gamma-ray Detector Energy Resolution on the Ability to Identify Radioactive Sources

This report describes the results of an initial study on radiation detector spectral resolution, along with the underlying methodology used. The study was done as part of an ongoing effort in Detection Modeling and Operational Analysis (DMOA) for the DNDO System Architecture Directorate. The study objective was to assess the impact of energy resolution on radionuclide identification capability, measured by the ability to reliably discriminate between spectra associated with 'threats' (defined as fissile materials) and radioactive 'non-threats' that might be present in the normal stream of commerce. Although numerous factors must be considered in deciding which detector technology is appropriate for a specific application, spectral resolution is a critical one for homeland security applications in which a broad range of non-threat sources are present and very low false-alarm rates are required. In this study, we have proposed a metric for quantifying discrimination capability, and have shown how this metric depends on resolution. In future work we will consider other important factors, such as efficiency and volume, and the relative frequency of spectra known to be discrimination challenges in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Sealed Radioactive Sources: An Uncertainty Analysis to Improve Detection Methods

The characterization of several types of sealed radiation sources has been accomplished. Specifically, cesium and strontium sources have been chemically characterized by inductively coupled plasma mass spectrometry (ICP-MS). One of the important pieces of information coming from the characterization is the “age” since purification. The age refers to the time since purification of the Cs or Sr components. A detailed error analysis of the mass spectrometric work has been undertaken to identify areas of improvement, as well as quantitating the effect the errors have on the “age” determined. This paper reports an uncertainty analysis associated with the measurements and identifying areas of improvement and alternative techniques that may reduce the uncertainties. In particular, work on isotope dilution using ICP-MS for the “age” determination of sealed sources will be presented, along with a detailed error analysis. The results will be compared to the original work done with simple instrument calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗