Search NASA⌕ Search

SEARCH · Search NASA

Results for “RCCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design considerations and experimental observations for the TAMU air-cooled reactor cavity cooling system for the VHTR

The Reactor Cavity Cooling System (RCCS) is a promising passive decay heat removal system for the Very High Temperature Reactor (VHTR) to ensure reliability of the transfer of the core residual and decay heat to the environment under all off-normal circumstances. A small scale experimental test facility was constructed at Texas A and M University (TAMU) to study pertinent multifaceted thermal hydraulic phenomena in the air-cooled reactor cavity cooling system (RCCS) design based on the General Atomics (GA) concept for the Modular High Temperature Gas-Cooled Reactor (MHTGR). The TAMU Air-Cooled Experimental Test Facility is ⅛ scale from the proposed GA-MHTGR design. Groundwork for experimental investigations focusing into the complex turbulence mixing flow behavior inside the upper plenum is currently underway. The following paper illustrates some of the chief design considerations used in construction of the experimental test facility, complete with an outline of the planned instrumentation and data acquisition methods. Computational Fluid Dynamics (CFD) simulations were carried out to furnish some insights on the overall behavior of the air flow in the system. CFD simulations assisted the placement of the flow measurement sensors location. Preliminary experimental observations of experiments at 120oC inlet temperature suggested the presence of flow reversal for cases involving single active riser at both 5 m/s and 2.25 m/s, respectively and four active risers at 2.25 m/s. Flow reversal may lead to thermal stratification inside the upper plenum by means of steady state temperature measurements. A Particle Image Velocimetry (PIV) experiment was carried out to furnish some insight on flow patterns and directions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Water NSTF Design, Instrumentation, and Test Planning

The following report serves as a formal introduction to the water-based Natural convection Shutdown heat removal Test Facility (NSTF) program at Argonne. Since 2005, this US Department of Energy (DOE) sponsored program has conducted large scale experimental testing to generate high-quality and traceable validation data for guiding design decisions of the Reactor Cavity Cooling System (RCCS) concept for advanced reactor designs. The most recent facility iteration, and focus of this report, is the operation of a 1/2 scale model of a water-RCCS concept. Several features of the NSTF prototype align with the conceptual design that has been publicly released for the AREVA 625 MWt SC-HTGR. The design of the NSTF also retains all aspects common to a fundamental boiling water thermosiphon, and thus is well poised to provide necessary experimental data to advance basic understanding of natural circulation phenomena and contribute to computer code validation. Overall, the NSTF program operates to support the DOE vision of aiding US vendors in design choices of future reactor concepts, advancing the maturity of codes for licensing, and ultimately developing safe and reliable reactor technologies. In this report, the top-level program objectives, testing requirements, and unique considerations for the water cooled test assembly are discussed, and presented in sufficient depth to support defining the program’s overall scope and purpose. A discussion of the proposed 6-year testing program is then introduced, which outlines the specific strategy and testing plan for facility operations. The proposed testing plan has been developed to meet the toplevel objective of conducting high-quality test operations that span across a broad range of single- and two-phase operating conditions. Details of characterization, baseline test cases, accident scenario, and parametric variations are provided, including discussions of later-stage test cases that examine the influence of geometric variations and off-normal configurations. The facility design follows, including as-built dimensions and specifications of the various mechanical and liquid systems, design choices for the test section, water storage tank, and network piping. Specifications of the instrumentation suite are then presented, along with specific information on performance windows, measurement uncertainties, and installation locations. Finally, descriptions of the control systems and heat removal networks are provided, which have been engineered to support precise quantification of energy balances and facilitate well-controlled test operations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Reference Model for Molten-Salt-Cooled Pebble-Bed Reactor Using SAM

To support the development and utilization of the SAM code for fluoride-salt-cooled high-temperature pebble-bed reactor (PB-FHR) safety analysis and licensing, an effort was devoted to developing reference models for PB-FHR primary loop and the reactor cavity cooling system (RCCS). A reference standard problem of a prototypical reactor design is foundational to NRC and industry to verify the adequacy of computer codes and evaluation models for a specific reactor type. The SAM code was enhanced for the reference PB-FHR model development, including a 1D-3D flow coupling scheme and conjugate heat transfer between porous media and solid structures. The reference FHR primary loop model was developed based on the UC Berkeley Mk1 FHR design with additional design features from the Kairos Power’s KP-FHR core. The PB-FHR core is modeled by a two-dimensional porous medium while the rest of the primary loop is represented by a SAM one-dimensional model. A SAM one-dimensional primary loop model was also developed for comparison using a single channel approach for the reactor core. Furthermore, the water-based NSTF cavity was modeled using SAM multi-dimensional flow module, to assist in evaluating SAM capabilities of modeling the emergency heat removal systems relying on RCCS concepts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ring Model Development and Validation for Prismatic HTGR Core Thermal-hydraulics and Safety Analysis

Because of the complex core geometry, prismatic high temperature gas-cooled reactors (prismatic HTGRs) often exhibit complex thermal fluid behaviors during both normal operating and transient conditions. Most HTGR designs rely on passive safety system for decay heat removal, such as the reactor cavity cooling system (RCCS). During postulated accidents like Pressurized Conduction Cooldown (PCC) event, the decay heat is first radially transferred from the core region to the reactor vessel outer surface, then to the RCCS cooling panels. The peak fuel temperature is controlled by heat transfer mechanisms with two distinctive characteristic length scales, i.e., the core-wise effective heat conduction and local heat conduction in the fuel pellet scale. As both length scales are essential to determine the fuel temperature, from the modeling perspective, computer codes must be able to capture heat transfer in both scales. This is challenging for both computational fluid dynamics (CFD) tools because of extremely large amount of computation resources required, and for system analysis codes because of the challenge to model the complex core geometry. Under the support of DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, efforts have been pursued to support HTGR technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior during safety-related transients. In our previous studies, the ring model was adopted in SAM and further developed to simulate the normal operating condition and a PCC event using the MHTGR-350 design of General Atomics as the reference design. This current work represents a continuation of these previous efforts, and the focus is to critically review and examine simplifications and assumptions made to develop the ring model, and to perform code validation using experimental data from an integral-effect test facility, the High Temperature Test Facility (HTTF) at the Oregon State University. In this study, the test PG-27 from the HTTF test suite was selected for code validation purpose. The test PG-27 is a transient test designed to simulate the PCC event of the MHTGR design. Very good agreements between SAM prediction and experimental measurements were found in both coolant and solid structure temperatures during the transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY23 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY23. As a continuation of the modeling effort from FY22, this year’s work focuses on improving the RELAP5-3D model developed previously for two-phase flow simulations. The RELAP5-3D model is updated to more accurately capture the heat loss experienced by the facility. The updated model is compared against experimental data for benchmarking purposes of the RELAP5-3D input model. By correctly accounting for heat loss, the updated RELAP5-3D model can now predict the two-phase baseline case more accurately. The onset and the duration of instability are captured well by the model. Furthermore, analyses are performed to better understand the instability mechanism experienced by the flow where the expansion of the boiling boundary in the chimney is studied in details and the fundamental frequencies of the oscillations are obtained. The updated RELAP5-3D model is further compared against four fault conditions, namely the reduction of riser header inlet flow area, depletion of system inventory, blocked riser channels, and static boiling scenario. For each fault condition, minor modifications and tuning are performed to improve the predictions of the model. The purpose of the analyses is to investigate the capability of RELAP5-3D in predicting complex two-phase flows in possible accident scenarios in actual Reactor Cavity Cooling System (RCCS). Overall, the model is able to capture the behaviors and trends of these fault conditions relatively well. Some discrepancies remain between the experimental data and the predictions, many of which are likely due to the differences in the predicted and experimental vapor generation rate. Future work will focus on the continued development of the current RELAP5-3D input model of the NSTF to both improve the accuracy of the model’s predictive capability and continue supporting the experimental program needs. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY25 Report on Water NSTF Testing: Parametric and Accident Testing with Lower Tank Inlet

The Natural Convection Shutdown Heat Removal Test Facility (NSTF) at Argonne National Laboratory has continued to generate empirical validation data on the performance of water-based reactor cavity cooling system (RCCS) for seven years. This data is actively being used to support the development of passive decay heat removal systems for advanced reactors. Distinguishing this facility are 1) the large, ½ scale of the facility and 2) its governance under an NQA-1 qualified program for producing data of the highest pedigree for advanced reactor designers and regulators. In addition to the experimental activities discussed in this report, a computational modeling program continues to support the experimental program and further accuracy and understanding of the computational models. Together, the experimental and computational work create a mutually beneficial relationship integral to the overall program objective of advancing the understanding of the RCCS technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microarray analysis of genes differentially expressed in HepG2 cells cultured in simulated microgravity: preliminary report

Developed at NASA, the rotary cell culture system (RCCS) allows the creation of unique microgravity environment of low shear force, high-mass transfer, and enables three-dimensional (3D) cell culture of dissimilar cell types. Recently we demonstrated that a simulated microgravity is conducive for maintaining long-term cultures of functional hepatocytes and promote 3D cell assembly. Using deoxyribonucleic acid (DNA) microarray technology, it is now possible to measure the levels of thousands of different messenger ribonucleic acids (mRNAs) in a single hybridization step. This technique is particularly powerful for comparing gene expression in the same tissue under different environmental conditions. The aim of this research was to analyze gene expression of hepatoblastoma cell line (HepG2) during early stage of 3D-cell assembly in simulated microgravity. For this, mRNA from HepG2 cultured in the RCCS was analyzed by deoxyribonucleic acid microarray. Analyses of HepG2 mRNA by using 6K glass DNA microarray revealed changes in expression of 95 genes (overexpression of 85 genes and downregulation of 10 genes). Our preliminary results indicated that simulated microgravity modifies the expression of several genes and that microarray technology may provide new understanding of the fundamental biological questions of how gravity affects the development and function of individual cells.

Non-NASA Center↗

Induction of three-dimensional assembly of human liver cells by simulated microgravity

The establishment of long-term cultures of functional primary human liver cells (PHLC) is formidable. Developed at NASA, the Rotary Cell Culture System (RCCS) allows the creation of the unique microgravity environment of low shear force, high-mass transfer, and 3-dimensional cell culture of dissimilar cell types. The aim of our study was to establish long-term hepatocyte cultures in simulated microgravity. PHLC were harvested from human livers by collagenase perfusion and were cultured in RCCS. PHLC aggregates were readily formed and increased up to 1 cm long. The expansion of PHLC in bioreactors was further evaluated with microcarriers and biodegradable scaffolds. While microcarriers were not conducive to formation of spheroids, PHLC cultured with biodegradable scaffolds formed aggregates up to 3 cm long. Analyses of PHLC spheroids revealed tissue-like structures composed of hepatocytes, biliary epithelial cells, and/or progenitor liver cells that were arranged as bile duct-like structures along nascent vascular sprouts. Electron microscopy revealed groups of cohesive hepatocytes surrounded by complex stromal structures and reticulin fibers, bile canaliculi with multiple microvilli, and tight cellular junctions. Albumin mRNA was expressed throughout the 60-d culture. A simulated microgravity environment is conducive to maintaining long-term cultures of functional hepatocytes. This model system will assist in developing improved protocols for autologous hepatocyte transplantation, gene therapy, and liver assist devices, and facilitate studies of liver regeneration and cell-to-cell interactions that occur in vivo.

NASA Center JSC↗

CFD analyses of natural circulation in the air-cooled reactor cavity cooling system

The Natural Convection Shutdown Heat Removal Test Facility (NSTF) is currently being built at Argonne National Laboratory, to evaluate the feasibility of the passive Reactor Cavity Cooling System (RCCS) for Next Generation Nuclear Plant (NGNP). CFD simulations have been applied to evaluate the NSTF and NGNP RCCS designs. However, previous simulations found that convergence was very difficult to achieve in simulating the complex natural circulation. To resolve the convergence issue and increase the confidence of the CFD simulation results, additional CFD simulations were conducted using a more detailed mesh and a different solution scheme. It is found that, with the use of coupled flow and coupled energy models, the convergence can be greatly improved. Furthermore, the effects of convection in the cavity and the effects of the uncertainty in solid surface emissivity are also investigated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical simulation of break flows occurring in the reactor cavity cooling system of a very high temperature reactor using a system CFD approach - 18437

To avoid accidents due to human error or the failure of components, the reactor cavity cooling system (RCCS) of a high temperature reactor must be able to operate naturally or passively safe. The system under consideration in this investigation is an air-cooled system which consists of an annular downcomer which is connected via a bottom-header to riser tubes. The downcomer and riser tubes are connected to the atmosphere via inlet and outlet manifold systems respectively. In this study the entire system is simulated using the 1D network codes GAMMA+ and Flownex. The study investigates the effect that breaks, causing a short circuit between one half of the inlet manifold and the corresponding half of the outlet manifold, will have on the performance of the cooling system. The agreement between the results obtained with the two codes is good. When the break size exceeds a certain value the flow may reverse in the relevant half of the outlet manifold. The critical break size is dependent on the elevation at which the break occurs. The reversal in the flow results in a drop of 10% in the heat removal capacity of the RCCS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examining Two-Phase Flow with Optical Sensors

In lieu of the events that occurred at Fukushima in 2011, passive safety shutdowns for nuclear reactors has become a focus area for recent research. At Argonne National Laboratory this research has been simulated using air as a means of cooling down a experimental reactor core. This operates on the principals of natural convection and can be further studied in the report devised by Lisowski et al. in 2014. The air reactor cavity cooling system (RCCS) at Argonne National Laboratory is currently being transitioned into a water cooled system for passive safety reactor shutdown systems. In this system eight water pipes (1.5'' schedule 160 stainless steel) will transfer heat by means of natural convection. However, the primary network pipe will be 4 inch schedule 40 stainless steel pipe. The adiabatic chimney portion of this piping segment will be under analysis for void fraction. Based on the internal temperature of the water pipes, the characteristic regimes of two-phase flow that could exist inside of the pipe are an area of interest for experimental analysis. Determining which phase the water exists is instrumental to understanding the state of the processes inside of the water cooling pipe. Knowledge of these states allows for analysis of the efficiency of the RCCS as it shuts down. The state of two-phase flow can be measured by the analysis of the fluids void fraction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary Report Of The FY25 Computational Fluid Dynamics Verification And Validation Exercises In The Advanced Reactor Technologies - Gas-cooled Reactor Program

Verification and Validation (V&V) of numerical tools is critical for ensuring reasonable predictions during design, safety analysis, and licensing. Recent work in the Advanced Reactor Technologies - Gas-cooled Reactor (ART-GCR) program has focused on V&V of common Computational Fluid Dynamics (CFD) tools that are used within the Untied States. This report presents an update on these CFD V&V activities. These Generation IV Forum (GIF) Very High Temperature Reactor (VHTR) Computational Methods, Validation, and Benchmarking (CMVB) is an international organization dedicated to the verification and validation of High Temperature Gas-Cooled Reactor (HTGR) simulation tools. Participation in the CMVB provides additional value to the V&V activities, as it allows for access to a wider range of data, and provides valuable benchmarking exercises. Three HTGR phenomena are targeted: Reactor Cavity Cooling System (RCCS) performance, core bypass flow, and lower plenum mixing. Simulations of the University of Wisconsin-Madison (UW-Madison) RCCS facilities are performed with Reynolds Averaged Navier-Stokes (RANS) in StarCCM+. Results are compared for both forced and natural convection conditions, with both exhibiting good agreement with experimental measurements. The Idaho National Laboratory (INL) matched index of refraction (MIR) and Korean Atomic Energy Research Institute (KAERI) bypass flow expeirments are used to validation CFD predictions of bypass flow. Simulations are performed with RANS in StarCCM+ and with Large Eddy Simulation (LES) in NekRS. Finally, preliminary simulations of the Institute of Nuclear and New Energy Technology (INET) lower plenum mixing facilities are presented. Initial work has developed models with LES, RANS, and porous media models. These preliminary models are presented and compared to each other to gauge differences in predictions with each of the three methods.

and Benchmarking (CMVB)↗

NRC Multiphysics Analysis Capability Deployment (FY2021--Part 1)

This report details progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” The tasks completed for this report are as follows: First, Task 1d: The net radiation transfer method was implemented into MOOSE for modeling reactor cavity cooling system geometries. RCCS models for two experiments were created: (1) Natural Convection Shutdown Heat Removal Test Facility (NSTF) experiment R022, and (2) HTTR VCS mockup. For validation, computed temperature distributions were compared to measured temperatures. Next, Task 4c: An algorithm for computing the pebble bed reactor equilibrium core isotopic com-position was developed and an initial version is implemented into the reactor multi-physics code Griffin. Initial results for a simplified axisymmetric pebble bed reactor are presented. Finally, Task 7: generation of a reference plant model for molten salt cooled pebble bed reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-3 of Water NSTF Matrix Testing: Two-Phase Parametric Test Series

The Natural convection Shutdown heat removal Test Facility (NSTF) is large scale test facility constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactor concepts. With support from the Department of Energy (DOE) offices of Advanced Reactor Technologies (ART) and Advanced Reactors Regulatory Development (RD), this facility reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical Results

Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 {+-} 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 {+-} 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 {+-} 13.6 min and 43.7 {+-} 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 {+-} 8.8 months, local recurrence-free survival was 14.4 {+-} 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 {+-} 16.6 ml/min/1.73 m{sup 2} before RF ablation vs. 47.2 {+-} 11.9 ml/min/1.73 m{sup 2} after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation Versus Robotic-Assisted Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

IntroductionThe authors compared the oncologic outcomes of radiofrequency ablation (RFA) with robotic-assisted partial nephrectomy (RPN) for the treatment of T1 stage renal cell carcinoma (RCC).Materials and methodsThis was a retrospective data analysis of a high-volume single tertiary centre. Patients were treated with RFA or RPN following multidisciplinary decision making. Only histologically proven RCCs were included. Baseline demographics were collected, and PADUA scores of tumour features were calculated to standardize baseline anatomy. Peri-operative complications, kidney function and oncological outcomes were compared.ResultsSixty-three cases were included in each group. Baseline renal function was poorer in RFA, and 16/63 RFA patients had tumours in single kidneys compared to 1/63 RPN cases (p < 0.001). Length of stay was shorter in RFA (1 vs. 3 days, p < 0.0001). Post-procedure renal function decline at 30 days was significantly less in RFA [(−0.8) ± 9.6 vs. (−16.1) ± 19.5 mls/min/1.73 m{sup 2}; p < 0.0001]. More minor complications were recorded in RPN (10/63 vs. 4/63, p = 0.15), but local recurrence was numerically higher in RFA (6/63 vs. 1/63, p = 0.11). Disease-free survival (DFS) was not significantly different (adjusted HR = 0.6, 95 % Cl 0.1–3.7; p = 0.60). Increasing tumour size was an independent predictor of local recurrence (adjusted HR = 1.7; 95 % Cl 1.1–2.6 per cm; p = 0.02).ConclusionsBoth RPN and RFA offer very good oncological outcomes for the treatment of T1 RCC with low peri-operative morbidity and similar oncologic outcomes. RFA demonstrated fewer peri-operative complications and better preservation of renal function, whereas RPN had an insignificantly lower local recurrence rate. RFA should be offered alongside RPN for selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗