Search NASASearch

SEARCH · Search NASA

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons

RD53 pixel readout integrated circuits for ATLAS and CMS HL-LHC upgrades

The RD53 collaboration has since 2013 developed new hybrid pixel detector chips with 50 × 50 μm2 pixels for the HL-LHC upgrades of the ATLAS and CMS experiments at CERN. A common architecture, design and verification framework has been developed to enable final pixel chips of different sizes to be designed, verified and tested to handle extreme hit rates of 3 GHz/cm2 (up to 12 GHz per chip) together with an increased trigger rate of 1 MHz and efficient readout of up to 5.12 Gbits/s per pixel chip. Tolerance to an extremely hostile radiation environment with 1 Grad over 10 years and induced SEU (Single Event Upset) rates of up to 100 upsets per second per chip have been major challenges to make reliable pixel chips. Three generations of pixel chips, and many specific mixed signal building blocks and radiation test chips, have been submitted and extensively tested to get to final production chips. The large, complex and high rate pixel chips have been developed with a strong emphasis on low power consumption together with a concurrent development and qualification of novel serial powering at chip, module and system level, to minimize detector material budget.

Alimonti, G

Testing the limits of ITkPixV2: the ATLAS inner tracker pixel detector readout chip

The ITkPixV2 chip is the final production readout chip for the ATLAS Phase 2 Inner Tracker (ITk) upgrade at the upcoming High-Luminosity LHC (HL-LHC). Due to the extraordinarily high peak luminosity at the HL-LHC of 5 × 1034 cm-1 s-1, ITkPixV2 must meet significant increases in nearly all design requirements compared to the current ATLAS Inner Detector (ID), including a 10× increase in trigger rate, a 7.5× increase in hit rate, a 3× increase in radiation tolerance, and a 12.5× decrease in pixel current draw per unit area, all while maintaining a similar power per unit area as present pixel detectors. Here we present the first measurements of the ITkPixV2 chip operated at the limits of the full chip design requirements, including in particular a measurement of the activity-induced current of the chip as a function of increasing hit rate.

Le Pottier, L

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators

A Radiation-Hard 8-Channel 15-Bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The custom design of a radiation-hardened, 8-channel, 40-MSPS, 15-bit resolution, 14.2-bit dynamic range, 11.4-ENOB ADC data acquisition ASIC fabricated in a commercial 65-nm triple-well CMOS technology is presented. The ADC is developed for and integrates seamlessly into the readout system for the ATLAS liquid argon (LAr) calorimeter in the high-luminosity large hadron collider (HLLHC) upgrade at CERN, which will require a total of 364 936 ADC channels. A three-stage MDAC+SAR pipelined ADC architecture was designed to meet the physics requirements and scientific goals of the ATLAS experiment. The ADC is a fully self-contained data acquisition system that includes foreground calibration, digital data processing, digital control, and supporting circuitry. The measured performance shows the ADC achieves a competitive dynamic range and SNDR, and it meets or exceeds the ATLAS analog requirements. Radiation tolerance and scalability design considerations were implemented at the device-, circuit-, and system-level. Radiation-hardening-by-design techniques used include redundancy for digital circuits, the use of MiM capacitors, and a hybrid RC-DAC for the ADC core. The ADC ASIC was demonstrated to be robust against the effects of the intense radiation expected in the HL-LHC experimental environment.

DAQ

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza

Reusable Verification Components for High-Energy Physics readout ASICs

Verification is a critical aspect of designing front-end (FE) readout ASICs for High-Energy Physics (HEP) experiments. These ASICs share several similar functional features, resulting in similar verification objectives, which can be addressed using comparable verification strategies. This contribution presents a set of re-usable verification components for addressing common verification tasks, such as clock generation, reset handling, configuration, as well as hit and fault injections. The components were developed as part of the CHIPS initiative and they have been successfully used in the verification of multiple HEP ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Thermal neutron imaging detector with wavelength shifting fiber and digital readout

Here, we developed a large area, digital thermal neutron imaging detector. The detector uses a 6 LiF/ZnS(Ag) neutron-sensitive scintillator combined with wavelength shifting fiber technology. The signals from fiber channels are amplified, integrated, and digitized using individual analog-to-digital converters for each channel. The neutron position is determined from the digitized signal using a least-squares gaussian-fitting algorithm. The detector size was 77 × 38 cm 2 (2926 cm 2 ), it provided 1.3 mm resolution, and its resolution can further be improved. The detector was designed for a powder diffraction neutron scattering beamline and provided substantial improvement of d-space resolution compared with existing detectors. This detector may have broader applications due to its large area and high spatial resolution extended over its large area.

6LiF/ZnS(Ag) scintillator

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Readout of Oriented Triplet Excitons in Linear Acenes via Room-Temperature Electrically Detected Magnetic Resonance

In this study, optically generated molecular spin centers offer an attractive platform for room-temperature spintronic and quantum applications. The linear acene family of molecules are especially good candidates due to their efficient generation of highly polarized triplet excitons via singlet fission. However, the direct detection and manipulation of these spin centers in thin films via the electrical means desirable for ultimate microelectronic devices has proven challenging. In particular, highly oriented triplet features have previously been detected in crystalline anthracene but longer acenes reveal only doublet features in Electrically-Detected Magnetic Resonance (EDMR). In this work we present EDMR spectra of highly oriented triplet excitons in pentacene for the first time, using a host-guest style device made of tetracene and pentacene. The guest acts as an energetic trap site, permitting the isolation and detection of molecular triplets at room temperature. Modeling of these results shows that the observed resonance features correspond to triplet sublevel transitions on isolated pentacene guest molecules. Rotation of the applied field confirms the tendency of the linear acenes to self-orient with the longest molecular axis perpendicular to the device substrate. Lastly, we find the disappearance of resonant triplet features in the neat acenes is not primarily due to the effects of exciton delocalization, but a broader mechanism of spin relaxation primarily influenced by exciton diffusivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Real Time implementation of Artificial Intelligence compression algorithm for High-Speed Streaming Readout signals

The new generation of high-energy physics experiments plans to acquire data in streaming mode. With this approach, it is possible to access the information of the whole detector (organized in time slices) for optimal and lossless triggering of data acquisitions. With this approach, data rates, especially in large detectors, are often very high, and the network is likely to be the bottleneck for the entire Streaming Read Out system. The aim of this work is to study the implementation of a lossy compression algorithm based on Artificial Intelligence: an Autoencoder. With Machine Learning it is possible to achieve a high compression ratio and fast inference time with only a small degradation of the signals, almost negligible for the specific application. This work explores different configurations of the Autoencoder and the implementation on different hardware. Different Autoencoder configurations are explored to find the best trade-off between compression ratio and reconstruction loss, both for signals and energy spectrum. Different hardware implementations are also explored to find the best platform to achieve real-time performance for the specific application.

Rossi, Fabio (ORCID:0009000385713885)

A sensing material-free and simple readout MEMS sensor for detecting Helium

Abstract In this work, we report a method that enables a standard electrostatic MEMS device to perform complex sensing functionalities, such as detecting the presence of helium without a sensing material or a conditioning circuit. Helium is a noble, odorless, non-reactive gas that is very challenging to detect. It is used in critical applications such as storing nuclear fuel waste inside a dry cask. In these applications, its leakage from the dry cask may indicate the cask's safe operation's degradation. A departure from the common practice of exciting the MEMS around its mechanical resonance, the method is based on exciting the MEMS around its electrical resonance circuit. This method shows that the tiny difference between the air dielectric constant (1.00059) and helium (1.000067) corresponding to only a few Femtofarad level capacitances produces a 25 mV difference without a conditioning circuit. Simulation results confirmed those findings and explored the sensor response at different operation conditions. This method eliminates the need for a heated microstructure and the need for absorption material. This method is not limited to gas sensing. It can be applied to other sensing mechanisms, such as acceleration and pressure measurements, and eliminate the complex circuit to read small capacitance in these applications.

Mohaidat, Sulaiman