Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

DAISY Benchmark Performance Data

This repository contains the underlying data from benchmark experiments for Drifting Acoustic Instrumentation SYstems (DAISYs) in waves and currents described in "Performance of a Drifting Acoustic Instrumentation SYstem (DAISY) for Characterizing Radiated Noise from Marine Energy Converters" (https://link.springer.com/article/10.1007/s40722-024-00358-6). DAISYs consist of a surface expression connected to a hydrophone recording package by a tether. Both elements are instrumented to provide metadata (e.g., position, orientation, and depth). Information about how to build DAISYs is available at https://www.pmec.us/research-projects/daisy. The repository's primary content is three compressed archives (.zip format), each containing multiple MATLAB binary data files (.mat format). A table relating individual data files to figures in the paper, as well as the structure of each file, is included in the repository as a Word document (Data Description MHK-DR.docx). Most of the files contain time series information for a single DAISY deployment (file naming convention: [site]_DAISY_[Drift #].mat) consisting of processed hydrophone data and associated metadata. For a limited number of DAISY deployments, the hydrophone package was replaced with an acoustic Doppler velocimeter (file naming convention: [site]_DAISY_[Drift #]_ADV.mat). Data were collected over several years at three locations: (1) Sequim Bay at Pacific Northwest National Laboratory's Marine & Coastal Research Laboratory (MCRL) in Sequim, WA, the energetic tidal channel in Admiralty Inlet, WA (Admiralty Inlet), and the U.S. Navy's Wave Energy Test Site (WETS) in Kaneohe, HI. Brief descriptions of data files at each location follow. - MCRL - (1) Drift #4 and #16 contrast the performance of a DAISY and a reference hydrophone (icListen HF Reson), respectively, in the quiescent interior of Sequim Bay (September 2020). (2) Drift #152 and #153 are velocity measurements for a drifting acoustic Doppler velocimeter in in the tidally-energetic entrance channel inside a flow shield and exposed to the flow, respectively (January 2018). (3) Two non-standard files are also included: DAISY_data.mat corresponds to a subset of a DAISY drift over an Adaptable Monitoring Package (AMP) and AMP_data.mat corresponds to approximately co-temporal data for a stationary hydrophone on the AMP (February 2019). - Admiralty Inlet - (1) Drift #1-12 correspond to tests with flow shielded DAISYs, unshielded DAISYs, a reference hydrophone, and drifting acoustic Doppler velocimeter with 5, 10, and 15 m tether lengths between surface expression and hydrophone recording package (July 2022). (2) Drift #13-20 correspond to tests of flow shielded DAISYs with three different tether materials (rubber cord, nylon line, and faired nylon line) in lengths of 5, 10, and 15 m (July 2022). - WETS - (1) Drift #30-32 correspond to tests with a heave plate incorporated into the tether (standard configuration for wave sites), rubber cord only, and rubber cord, but with a flow shielded hydrophone (November 2022). (2) Drift #49-58 and Drift #65-68 correspond to measurements around mooring infrastructure at the 60 m berth where time-delay-of-arrival localization was demonstrated for different DAISY arrangements and hydrophone depths (November 2022).

16 TIDAL AND WAVE POWER↗

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Real-time and post-hoc compression for data from Distributed Acoustic Sensing

Distributed Acoustic Sensing (DAS) is an emerging sensing technology that records the strain-rate along fiber optic cables at high spatial and temporal resolution. This technique is becoming a popular tool in seismology, hydrology, and other subsurface monitoring applications. However, due to the large coverage (10’s of km) and high density of measurements (1m spacing at 100’s of Hz), a DAS installation could produce terabytes of data records per day. Because many DAS instruments are deployed in remote locations, this large data size poses significant challenges to its transfer and storage. In this paper, we explore lossless compression methods to reduce the storage requirement in both real-time and post-hoc scenarios. Here we propose a two-stage compression method to improve the compression ratio and compression speed. This two-stage compression method could reduce the storage requirement by 40%, which is 20% more than other lossless methods, such as ZSTD. We demonstrate that the compression method could complete its operation well before the DAS instrument needs to output the next file, making it suitable for real-time DAS acquisition. We also implement a parallel compression method for a post-hoc scenario and demonstrate that our method could effectively utilize a parallel computer. With 256 CPU cores, our parallel compression method achieves the speed of 26GB/second.

58 GEOSCIENCES↗

Reverse Time Migration of Explosion-generated Infrasound and Ground-Coupled Airwaves

Accurately locating sources of seismic and infrasonic energy is integral to global monitoring of earthquakes and explosions. Infrasound arrivals times can be used to calculate the origins of events that generate acoustic energy. Picking times of emergent infrasound arrivals, however, can be difficult and prone to uncertainty. Reverse time migration (RTM) is a waveform based location method that does not rely on picked arrival times. Here we use RTM to locate a known chemical explosion that generated acoustic and acoustic-to-seismic signals on 26 and 108 receivers, respectively. All location predictions are less than 24 km from the known location with time errors of less than three minutes. We find strong overall agreement between our results and those of existing RTM and arrival time based methods. Our initial results suggest that RTM is a promising method of event location using acoustic arrivals recorded on both infrasound and seismic instrumentation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Global Climate

The 2019 global lower tropospheric temperature (LTT), which encompasses the atmosphere from the surface to ~10 km, ranked second warmest in seven datasets and first or third in the remaining two (Fig. 2.7). These records extend back to 1958 using radiosonde (balloon-borne instrumentation) data and one reanalysis dataset (JRA55), which demonstrate reasonable agreement with the 40+ year satellite record (since late 1978) and two other reanalysis datasets (since 1979 and 1980, ERA5 and MERRA2, respectively). Aweak El Niño contributed to increased global temperatures as 2019 values were +0.44° to +0.68°C higher than the 1981–2010 average (depending on the dataset), being just slightly cooler (~0.07°C on average) than the record warm year of 2016. At least fourof the five globally complete datasets (ERA5, MERRA2, JRA55, RSS, UAH) recorded each of the four months—June, September, November, and December—as experiencing their warmest monthly global LTT.

58 GEOSCIENCES↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

Hindsight logging for model training

In modern Machine Learning, model training is an iterative, experimental process that can consume enormous computation resources and developer time. To aid in that process, experienced model developers log and visualize program variables during training runs. Exhaustive logging of all variables is infeasible, so developers are left to choose between slowing down training via extensive conservative logging, or letting training run fast via minimalist optimistic logging that may omit key information. As a compromise, optimistic logging can be accompanied by program checkpoints; this allows developers to add log statements post-hoc, and "replay" desired log statements from checkpoint---a process we refer to as hindsight logging. Unfortunately, hindsight logging raises tricky problems in data management and software engineering. Done poorly, hindsight logging can waste resources and generate technical debt embodied in multiple variants of training code. In this paper, we present methodologies for efficient and effective logging practices for model training, with a focus on techniques for hindsight logging. Our goal is for experienced model developers to learn and adopt these practices. To make this easier, we provide an open-source suite of tools for Fast Low-Overhead Recovery (flor) that embodies our design across three tasks: (i) efficient background logging in Python, (ii) adaptive periodic checkpointing, and (iii) an instrumentation library that codifies hindsight logging for efficient and automatic record-replay of model-training. Model developers can use each flor tool separately as they see fit, or they can use flor in hands-free mode, entrusting it to instrument their code end-to-end for efficient record-replay. Our solutions leverage techniques from physiological transaction logs and recovery in database systems. Evaluations on modern ML benchmarks demonstrate that flor can produce fast checkpointing with small user-specifiable overheads (e.g. 7%), and still provide hindsight log replay times orders of magnitude faster than restarting training from scratch.

Computer Science↗

Terrestrial laser scanning data (Levels 0 and 1) from Urban Biogeochemistry Pilot Project sites, Knoxville, Tennessee, Jul 2024 - Jul 2025

This data package contains data from terrestrial laser scanning (TLS) at five urban park sites in Knoxville, Tennessee, USA. All parks include open-grown and/or closed-canopy trees and mixed nearby land use. These study sites were established as part of the Urban Biogeochemistry Pilot Project, which has an overall goal of better understanding how hydrobiogeochemical cycling is altered within the human environment. These five sites represent a gradient of urbanization, and were instrumented to understand hydrological and biogeochemical cycling (e.g., soil moisture, soil physical properties and biogeochemistry, tree transpiration, species type). The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree- and stand-level characterization of woody structure and leaf area. TLS scans were placed to capture the area around trees with sap flow sensors, and as much of a 50 m radius area around the meteorological station as possible given site property limits. Derived products will allow upscaling of water content and transpiration data. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Performance of a Drifting Acoustic Instrumentation SYstem (DAISY) for characterizing radiated noise from marine energy converters

Marine energy converters can generate electricity from energetic ocean waves and water currents. Because sound is extensively used by marine animals, the radiated noise from these systems is of regulatory interest. However, the energetic nature of these locations poses challenges for performing accurate passive acoustic measurements, particularly with stationary platforms. The Drifting Acoustic Instrumentation SYstem (DAISY) is a modular hydrophone recording system purpose-built for marine energy environments. Using a flow shield in currents and mass–spring–damper suspension system in waves, we demonstrate that DAISYs can effectively minimize the masking effect of flow noise at frequencies down to 10 Hz. In addition, we show that groups of DAISYs can utilize time-delay-of-arrival post-processing to attribute radiated noise to a specific source. Consequently, DAISYs can rapidly measure radiated noise at all frequencies of interest for prototype marine energy converters. Furthermore, the resulting information from future operational deployments should support regulatory decision-making and allow technology developers to make design adjustments that minimize the potential for acoustic impacts as their systems are scaled up for utility-scale power generation.

16 TIDAL AND WAVE POWER↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Tree-ring evidence marks year 2022 as the driest spring season in nearly four centuries in the Western Himalayas

The Hindukush-Karakoram-Himalayan region is a crucial freshwater source for billions across South Asia, yet its climate remains poorly understood due to limited long-term records. Winter and spring precipitation govern snow accumulation and downstream water availability in dry months particularly across the Western Himalayas (WH), but recent decades show intensifying droughts with unclear long-term context. Here, we have reconstructed a nearly four-century-long spring i.e. February to May (FMAM) precipitation for the Lahaul region of the (WH), an area dominated by the Western Disturbances. This record was developed using moisture-sensitive Cedrus deodara (Deodar) tree-rings from three high-elevation sites. A regional composite tree-ring-width chronology, developed through a Nested Principal Component Analysis and modeled with a nonlinear Generalized Additive Model (GAM) that explains 71 % of the variance during the calibration period. We identified the last two decades as the most precipitation deficit phase and the year 2022 showing the driest FMAM on record. The observed rise in the FMAM dry episodes post 1999 CE in our reconstruction, corresponds to the meteorological records. This recent drying is linked to a northward shift of the subtropical westerly jet and reduced moisture transport, both associated with unusual sea surface temperature patterns in the tropical Indian Ocean and the Western Pacific Ocean. Our results provide compelling evidence of long-term hydroclimatic instability in the WH and emphasize the value of tree-ring records in extending precipitation histories beyond the instrumental observations. Such reconstructions can be benchmarks to validate high-resolution climate models and formulate adaptation policies to mitigate future risks.

Cedrus deodara↗

Combined Optical and Radio-Frequency Measurements of a Lightning Megaflash by the FORTE Satellite

The optical and VHF instrumentation on the Fast On-Orbit Recording of Transient Events (FORTE) satellite is used to document the combined phenomenology evolution of a lightning “megaflash” – mesoscale lightning that propagates laterally over exceptional distances. We identify a FORTE flash whose maximum extent was 82 km and inferred length over multiple distinct branches exceeded 100 km. This flash lasted 1.2 s and produced 250 optical and 591 RF events. We find that the channel development mapped by FORTE’s pixelated lightning imager (LLS) occurred at a typical speed of 2.6x10 5 m s -1 and was accompanied by sustained periods of VHF emission that could individually exceed 100 ms in duration. The impulsive IC events generated by the flash indicate that this development occurred at altitudes between 3 and 8 km. Four +CG strokes were identified in the VHF waveform data that are responsible for two of the three highly-radiant LLS groups (two of the +CGs were not as optically bright as the others). These strokes occurred at different locations throughout the flash footprint with the most distant strokes separated by approximately 50 km. These space-based observations match previous observations of megaflashes as well as ground-based measurements of negative leader development during “spider” lightning, suggesting that FORTE is sensing the same phenomena.

Peterson, Michael Jay↗

EPCAPE – Proton Transfer Reaction Mass Spectrometer Field Campaign Report

The Eastern Pacific Cloud Aerosol Precipitation Experiment – Proton Transfer Reaction Mass Spectrometer (EPCAPE-PTRMS) campaign was created in response to the urgent need expressed by EPCAPE co-investigators for measurements of volatile organic compounds (VOCs) during the EPCAPE intensive operational period. A proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS, model 8000, Ionicon Analytik) was deployed to Mt. Soledad, San Diego, California, on 15 May 2023 for the measurement of VOCs. The instrument was installed in the same Atmospheric Radiation Measurement (ARM) user facility guest container that the Smith group used for the EPCAPE – Ultrafine Particle Properties (EPCAPE-UPP) campaign. The Smith group provided the sample inlet and operated and maintained the instrument. A complete VOC mass spectrum was recorded every 10 sec, continuously. Calibrations using a traceable VOC mixture were performed onsite at the end of the campaign.

54 ENVIRONMENTAL SCIENCES↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Node Monitoring as a Fault Detection Countermeasure against Information Leakage within a RISC-V Microprocessor

Advanced, superscalar microprocessors (μP) are highly susceptible to wear-out failures because of their highly complex, densely packed circuit structure and extreme operational frequencies. Although many types of fault detection and mitigation strategies have been proposed, none have addressed the specific problem of detecting faults that lead to information leakage events on I/O channels of the μP. Information leakage can be defined very generally as any type of output that the executing program did not intend to produce. In this work, we restrict this definition to output that represents a security concern, and in particular, to the leakage of plaintext or encryption keys, and propose a counter-based countermeasure to detect faults that cause this type of leakage event. Fault injection (FI) experiments are carried out on two RISC-V microprocessors emulated as soft cores on a Xilinx multi-processor System-on-chip (MPSoC) FPGA. The μP designs are instrumented with a set of counters that records the number of transitions that occur on internal nodes. The transition counts are collected from all internal nodes under both fault-free and faulty conditions, and are analyzed to determine which counters provide the highest fault coverage and lowest latency for detecting leakage faults. We show that complete coverage of all leakage faults is possible using only a single counter strategically placed within the branch compare logic of the μPs.

42 ENGINEERING↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

SAIL-Net CloudPuck CCN Data

SAIL-Net is a DOE funded project in the East River Watershed near Crested Butte, Colorado with the goal of advancing our understanding of aerosol-cloud interactions in complex, mountainous regions. Through the deployment of a network of six low cost microphysics nodes in Fall 2021 in the same domain at the SAIL campaign, SAIL-Net provides data on aerosol size distributions, cloud condensation nuclei (CCN), and ice nucleations particles (INP). This network enables the investigation of small-scale variations in complex terrain. This specific dataset provides the cleaned data recorded from the CloudPuck, an in house instrument made by Handix Scientific that counts CCN concentrations. The CloudPuck was deployed at the sites for the summer/fall of 2022 before winter conditions were too harsh to maintain the instrument. For more information on the the CloudPuck or how the raw data are processed, see the read me.

54 ENVIRONMENTAL SCIENCES↗

A Modular 512-Channel Neural Signal Acquisition ASIC for High-Density 4096 Channel Electrophysiology

The complexity of information processing in the brain requires the development of technologies that can provide spatial and temporal resolution by means of dense electrode arrays paired with high-channel-count signal acquisition electronics. In this work, we present an ultra-low noise modular 512-channel neural recording circuit that is scalable to up to 4096 simultaneously recording channels. The neural readout application-specific integrated circuit (ASIC) uses a dense 8.2 mm × 6.8 mm 2D layout to enable high-channel count, creating an ultra-light 350 mg flexible module. The module can be deployed on headstages for small animals like rodents and songbirds, and it can be integrated with a variety of electrode arrays. The chip was fabricated in a TSMC 0.18 µm 1.8 V CMOS technology and dissipates a total of 125 mW. Each DC-coupled channel features a gain and bandwidth programmable analog front-end along with 14 b analog-to-digital conversion at speeds up to 30 kS/s. Additionally, each front-end includes programmable electrode plating and electrode impedance measurement capability. We present both standalone and in vivo measurements results, demonstrating the readout of spikes and field potentials that are modulated by a sensory input.

47 OTHER INSTRUMENTATION↗