Search NASA⌕ Search

SEARCH · Search NASA

Results for “REINFORCED PLASTIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Test Report - Fault Current Through Graphite Filament Reinforced Plastic

Tests were performed to determine the damage to samples of composite material when a current carrying wire is shorted to the surface of the composite material, and to determine whether enough current can flow through the material to blow a fuse before damage can occur. Fault current tests were performed on samples of graphite epoxy materials. Samples consisted of six layers of IM7 graphite fiber mat in Hercules 8552 epoxy resin. A variable power supply provided up to 35 amps of current. The high voltage side of the power supply was attached to a wire at the end of a hinged arm, and the low side was attached to the edge of the sample. To test joints, the return was connected to the edge of one sample, and the high side was shorted to the top of the other sample. Tests show that when current exceeds approximately 5 amps, the graphite glows, and the epoxy melts out at the shorted contact. At higher current levels the epoxy burns. At voltages above 15 volts the epoxy outer coat is easily broken, and fire, flame, and a rise in current occur suddenly. When joints are introduced, resistance is increased, and the maximum current resulting from a short circuit to the graphite epoxy is reduced. This condition can easily result in fault current lower than the circuit breaker limit and higher than the 5 amp ignition level. The shorting contact and the joint become hot spots with melting epoxy, smoke, and fire.

Evans, R. W.↗

Structure and properties of polymeric composite materials during 1501 days outer space exposure at Salyut-7 orbital station

Specimens of polymeric composite materials for aviation and space applications such as glass fiber reinforced plastics (GFRP), carbon fiber reinforced plastics (CFRP), organic fiber reinforced plastics (OFRP), and hybrid plastics (HP) based on epoxy compounds were exposed to the space environment on the surface of Salyut-7 orbital station. The space exposure lasted 1501 days as a maximum. The data relating to the change in mechanical properties, mass losses, glass transition temperature, linear thermal expansion coefficient, and microstructure after various periods of exposure are given. It has been found that the change in properties is caused by the processes of binder postcuring and microerosion of the exposed surface of plastics. The phenomenon of strengthening of the surface layer of hybrid composites, due to which the nature of destruction changes at bending loads, has been revealed.

Startsev, Oleg V.↗

Impact resistance of fiber composites

Stress-strain curves are obtained for a variety of glass fiber and carbon fiber reinforced plastics in dynamic tension, over the stress-strain range of 0.00087-2070/sec. The test method is of the one-bar block-to-bar type, using a rotating disk or a pendulum as the loading apparatus and yielding accurate stress-strain curves up to the breaking strain. In the case of glass fiber reinforced plastic, the tensile strength, strain to peak impact stress, total strain and total absorbed energy all increase significantly as the strain rate increases. By contrast, carbon fiber reinforced plastics show lower rates of increase with strain rate. It is recommended that hybrid composites incorporating the high strength and rigidity of carbon fiber reinforced plastic with the high impact absorption of glass fiber reinforced plastics be developed for use in structures subjected to impact loading.

Chamis, C. C.↗

Transition from glass to graphite in manufacture of composite aircraft structure

The transition from fiberglass reinforced plastic composites to graphite reinforced plastic composites is described. Structural fiberglass design and manufacturing background are summarized. How this experience provides a technology base for moving into graphite composite secondary structure and then to composite primary structure is considered. The technical requirements that must be fulfilled in the transition from glass to graphite composite structure are also included.

Buffum, H. E.↗

Pyrolysis Rate and Yield Strength Reduction Incarbon Fiber and Glass Fiber Composites Underreentry Heating Conditions

The behavior of composite materials, specifically carbon fiber reinforced plastic (CFRP) and glass fiber reinforced plastic (GFRP), under reentry conditions poses a problem for space debris reentry risk modeling. Since these materials pyrolyze rather than melt and their different components demise at different rates, modeling their destruction to determine ground impact risk is complex. Modern spacecraft are using these materials in ever-greater quantities owing to their superior strength-to-weight characteristics, and this has required that the orbital debris community improve its understanding of how these materials demise on reentry. The NASA Orbital Debris Program Office undertook an extensive test campaign to better understand the rate at which several types of GFRP and CFRP materials pyrolyze under reentry heating conditions and how that pyrolysis affects the ultimate strength of the material. GFRP with a polyester resin (G10/FR-4) and CFRP with epoxy, cyanate ester, vinyl ester, and phenolic resins were tested. The test campaign was carried out at the Inductively Coupled Plasma (ICP) Torch Facility at the University of Texas at Austin. Because the ICP facility operates in a shirt-sleeve environment, test samples can be changed within seconds or minutes, allowing many samples to be tested in a short period. Two heat flux rates, 20 W/m2 and 30W/m2, and two oxygen concentration conditions, 0% and 2% of atmospheric, were applied to all five types of material. To measure both the char rate and the effect of pyrolysis on the ultimate material strength, two types of test were carried out for each material: a char rate test on a ~10 mm thick sample of material and an in-situ bending stress test of a ~2 mm thick sample of material. Measurements of the char rate showed very similar average pyrolysis front velocity in epoxy resin CFRP as in G10 at 3.6 mm/min and 3.4 mm/min, respectively. However, the total mass loss rate in theG10 was nearly double that of the CFRP at 3.8 g/min and 2.2 g/min, respectively. This result represented a slow ablation rate of carbon fibers in the CFRP at the temperatures encountered in low Earth orbit reentry and a comparatively rapid removal of the glass fibers in G10 due to melting and spallation. Pyrolysis front velocity was more significantly affected by the type of plastic than the type of fiber, with the cyanate ester CFRP samples displaying an average pyrolysis front velocity of only 1.9 mm/min. Similarly, the effect of thermal exposure on the ultimate strength of the material depended heavily on the type of plastic and very little on the type of fiber in the material. Epoxy, vinyl ester, and polyester resins all behaved very similarly, with complete structural failure at between 400 J/g and 600 J/g of specific absorbed heat. Phenolic and cyanate ester resins, on the other hand, displayed a change in structural properties that was only barely measurable with the current apparatus even after the maximum exposure time tested. These data are being incorporated into a numerical model of the ablation and demise of composite materials that will be used to more accurately calculate the ground casualty risk of future spacecraft.

Benton R. Greene↗

Static and dynamic fatigue behavior of glass filament-wound pressure vessels at ambient and cryogenic temperatures.

Investigation of the pressure load carrying capacity and fatigue strength of filament-wound glass-reinforced plastic pressure vessels subjected to static and cyclic loading at ambient and cryogenic (liquid nitrogen) temperature environments. The results indicate that the static fatigue problem is not critical at cryogenic temperatures. Under static loading at liquid nitrogen temperature, a reinforced plastic cylinder sustained pressurization for 88 days without failure at about 90% of the single cycle burst strength. At ambient temperature, the static life at 90% of the burst strength was about 7 min. Under cyclic loading in liquid nitrogen, no failure resulted after 1509 cycles at 55% of the single cycle burst strength. Under the same cyclic loading at ambient temperature, the test results would predict failure in the reinforced plastic. The results of similar tests upon adhesively bonded polyimide aluminum-foil lined cylinders are also reviewed.-

Hanson, M. P.↗

Summary of Marine and Hydrokinetic (MHK) Composites Testing at Montana State University

Marine and hydrokinetic (MHK) energy technologies convert the energy of waves, tides, and river and ocean currents into electricity. The primary structure of MHK energy devices have difficult and challenging environments for which fiber reinforced plastics are often considered. For cost benefits, glass fiber reinforced plastics (GFRP) are the most prevalent system under consideration. Montana State University and Sandia National Laboratories have performed research into the moisture effects on the stiffness, strength, and damage of GFRPs for many years. This paper presents a summary of a portion of this effort and also provides references to the thesis and conferences that contain the detailed information. The results include models of moisture absorption, effects of stress on moisture uptake, effects of moisture on damage modes and development, laminate stacking order effects, and culminates with moisture uptake effects on a large sample of industry collected coupons.

13 HYDRO ENERGY↗

Electrically conductive carbon fiber layers as lightning strike protection for non-conductive epoxy-based CFRP substrate

A large amount of electrically conductive fillers is needed to enhance a Carbon Fiber Reinforced Plastics (CFRP) electrical conductivity enough to withstand lightning strikes of peak currents. However, such large alien constituents hamper the inherent good mechanical properties of CFRP structures. In this work, a solution has been proposed to retain both desired properties in a CFRP laminate. Layer-wise hybrid laminate has been demonstrated as a solution for lightning strike protection of Carbon Fiber Reinforced Plastics (CFRP). Top few layers of a hybrid laminate are prepared using electrically conductive polymer-based resin (CF/C-POLY) to provide effective dissipation of lightning current while epoxy-based CFRP substrate (CF/Epoxy) provides the main structural strength. An insulating adhesive layer is used to bond CF/C-POLY and CF/Epoxy to prepare the laminate. The hybrid laminates were tested for their effectiveness against lightning strikes. Laminates were struck by modified lightning waveform of component A with peak current of -14 kA and -40 kA. The performance of the laminates against lightning strike were evaluated using high speed camera, high-speed and thermal camera. It is found that CF/C-POLY layer successfully defended the main structural component i.e. CF/Epoxy from lightning direct damage.

36 MATERIALS SCIENCE↗

Strength of anisotropic wood and synthetic materials

The possibility of using general formulas for determining the strength of different anisotropic materials is considered, and theoretical formulas are applied and confirmed by results of tests on various nonmetallic materials. Data are cited on the strength of wood, plywood, laminated wood plastics, fiber glass-reinforced plastics and directed polymer films.

Ashkenazi, Y. K.↗

Combining Reclaimed PET with Bio-Based Monomers Enables Plastics Upcycling

Less than 30% of PET plastic is recycled in the United States. The low reclamation rate may be due to mechanical recycling accounting for the majority of commercial PET recycling. Mechanical recycling yields a lower-quality recycled plastic than the process of chemically recycling back to the monomer phase, which can be energetically and economically expensive. In this work, recently published in Joule, reclaimed PET bottles are chemically recycled and converted into higher-value fiberglass-reinforced plastics (FRPs).This presentation will focus on the supply-chain level energy and greenhouse gas emissions intensities associated with this novel upcycling route. The Materials Flows through Industry supply chain analysis tool, developed at NREL, is used to estimate these impacts. Depending on the extent and speed of adoption, this strategy for plastic upcycling could lead to significant energy usage and emissions reductions over the traditional FRP supply chain. Overall, this approach may provide an economic incentive for plastics recycling and renewable feedstock use through the creation of higher-value FRPs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Structural Optimization (Final Technical Report V.2.0)

The overall Project (Project) objective is to materially decrease the leveled cost of energy (LCOE) of the Columbia Power (CPwr) StingRAY utility-scale wave energy converter (WEC). This will be achieved by reducing structural material and manufacturing costs and increasing energy output. In this Project, improving the overall Power-to-Weight ratio (PWR) is accomplished through lowering design margins - allowing for weight reduction and more efficient, cost-effective WEC manufacturing and assembly - and by optimizing mass-related WEC performance parameters, such as center of gravity and system inertia. A mixed materials approach to further structural optimization was developed under this Project and validated with extensive laboratory structural testing. This approach substitutes fiber-reinforced plastic (FRP) for steel where appropriate. The benefits of steel are maintained where most useful, for instance at structural joints where the stiffness of steel is required, and the complex geometry is more readily fabricated with steel. However, there are structural spans whose simple shapes are readily fabricated with mandrel-wound FRP and where significant cost and weight savings can be found. An adhesive, double lap shear joint is used to join the FRP and steel subcomponents.

16 TIDAL AND WAVE POWER↗

An experiment on the use of disposable plastics as a reinforcement in concrete beams

Illustrated here is the concept of reinforced concrete structures by the use of computer simulation and an inexpensive hands-on design experiment. The students in our construction management program use disposable plastic as a reinforcement to demonstrate their understanding of reinforced concrete and prestressed concrete beams. The plastics used for such an experiment vary from plastic bottles to steel reinforced auto tires. This experiment will show the extent to which plastic reinforcement increases the strength of a concrete beam. The procedure of using such throw-away plastics in an experiment to explain the interaction between the reinforcement material and concrete, and a comparison of the test results for using different types of waste plastics are discussed. A computer analysis to simulate the structural response is used to compare the test results and to understand the analytical background of reinforced concrete design. This interaction of using computers to analyze structures and to relate the output results with real experimentation is found to be a very useful method for teaching a math-based analytical subject to our non-engineering students.

Chowdhury, Mostafiz R.↗