Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL SECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

2015 South Carolina PV Soft Cost and Workforce Development Part 2: Six Month Confirmation of Anticipated Job Growth

In 2015, a program was initiated to carefully track and monitor the growth of the solar industry in SC. Prior to then, little information was available on the costs associated with distributed photovoltaic (PV) installations in the Southeastern US. For this report, data were collected from businesses on the number of hires they had at the end of 2014 and compared with data for 2015 and June 2016. It was found that the percentage of installers within the state who serve the residential sector increased to 82% from 67%. During the same time period, the average size of initiated installations for residential, commercial, and utility scale installations all trended upwards. Where residential installations were typically 5 kW-DC in 2014, they were typically 10 kW-DC by late 2015 and in mid-2016. For commercial installations, the average size grew from 84 kW-DC in 2014 to between 136-236 kW-DC in 2015 and then 188-248 kWDC in mid-2016. An exception was seen in utility scale installations where a 2.3 MW-DC system was common in 2014, the size grew to be 5-15 MW-DC in late 2015. The average size dropped 3.1-4.4 MWDC in mid-June 2016, though individual averages up to 20 MW-DC were reported.

99 GENERAL AND MISCELLANEOUS↗

Beyond-the-Meter: Unaccounted Sources of Methane Emissions in the Natural Gas Distribution Sector

The United States Environmental Protection Agency maintains an inventory of greenhouse gas emissions in accordance with the Intergovernmental Panel on Climate Change. Methane (CH 4 ), a potent gas with a global warming potential 86–125× that of carbon dioxide (CO 2 ) over a twenty-year period, is the main component of natural gas (NG). As NG becomes an increasingly larger percentage of the energy resources used in the United States, it is ever more important to evaluate the CH 4 emissions inventory. However, the inventory also does not account for all possible sources of CH 4 leaks, contributing to uncertainty in the national CH 4 inventory. Discrepancies between top-down and bottom-up inventories of CH 4 emissions imply that there are significant unaccounted-for sources of CH 4 leaks, especially over cities. Diffuse CH 4 plumes above cities that are not attributable to distribution pipelines or other NG infrastructure suggest many small beyond-the-meter leaks together contribute to large emissions. Here, we evaluate the distribution sector of the CH 4 emissions inventory and make suggestions to improve the inventory by analyzing end-user emissions. Preliminary research into beyond-the-meter emissions suggests that while individually small, the appliances and buildings that make up the residential sector could contribute significantly to national scale emissions. Furnaces are the most leak-prone of appliances, contributing to 0.14% of total CH 4 emissions from the NG sector in the United States. Combining measurements from whole house emissions and steady-state operation of appliances, we estimate that residential homes and appliances could release 9.1 Gg CH 4 yearly in the United States, totaling over 2% of the CH 4 released from the NG sector. Here, while factors such as appliance age and usage, climate, and residential setting could influence the emissions profile of individual appliances, these preliminary estimates justify further exploration of beyond-the-meter emissions.

03 NATURAL GAS↗

A Hybrid dasymetric and machine learning approach to high-resolution residential electricity consumption modeling

As urban areas continue to grow and evolve in a world of increasingenvironmental awareness, the need for detailed information regarding residentialenergy consumption patterns has become increasingly important. Though currentmodeling efforts mark significant progress in the effort to better understand thespatial distribution of energy consumption, the majority of techniques are highlydependent on region-specific data sources and often require building- ordwelling-level details that are not publicly available for many regions in the UnitedStates. Furthermore, many existing methods do not account for errors in input datasources and may not accurately reflect inherent uncertainties in model outputs. Wepropose an alternative and more general hybrid approach to high-resolution residentialelectricity consumption modeling by merging a dasymetric model with acomplementary machine learning algorithm. The method’s flexible data requirementand statistical framework ensure that the model both is applicable to a widerange of regions and considers errors in input data sources.

cities↗

A study of appliance ownership and electricity consumption determinants in urban Ghanaian households

The residential sector in Ghana accounts for about 40% of aggregate electricity consumption out of which urban centers contribute 70%. The high weighted share of residential electricity use is attributed to high appliance ownership and use, and other household/building factors. The ability to determine how changes in the pattern of these factors influence electricity demand is critical if efforts to reduce consumption are to be effective. Here this study combines a residential electricity consumption survey (RECS) with electricity end-use monitoring of 60 households in Tema city Ghana, to yield the first ever comprehensive investigation of city-scale electricity consumption in urban Ghanaian homes. A multiple linear regression analysis is used to identify the most statistically significant indicators of appliance ownership and household electricity consumption. Results indicate that ownership of air conditioner, freezer, fan, refrigerator and television; and changes in socio-economic and building factors such as energy efficiency awareness and practice; income; household size and floor space show high statistical significance, and collectively explain 57% variance in households’ total electricity consumption. The presence of dependent children increases ownership of television, iron, washing machine and small kitchen appliances. This work provides a solid foundation for developing more tailored energy-saving policy interventions targeted at households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residential savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in multiple jurisdictions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

energy efficiency↗

A Method for Modeling Household Occupant Behavior to Simulate Residential Energy Consumption

This paper presents a statistical method for modeling the behavior of household occupants to estimate residential energy consumption. Using data gathered by the U.S. Census Bureau in the American Time Use Survey (ATUS), actions carried out by survey respondents are categorized into ten distinct activities. These activities are defined to correspond to the major energy consuming loads commonly found within the residential sector. Next, time varying minute resolution Markov chain based statistical models of different occupant types are developed. Using these behavioral models, individual occupants are simulated to show how an occupant interacts with the major residential energy consuming loads throughout the day. From these simulations, the minimum number of occupants, and consequently the minimum number of multiple occupant households, needing to be simulated to produce a statistically accurate representation of aggregate residential behavior can be determined. Finally, future work will involve the use of these occupant models along side residential load models to produce a high-resolution energy consumption profile and estimate the potential for demand response from residential loads.

American Time Use Survey↗

Exploring the potential of non-residential solar to tackle energy injustice

Despite the observed disparities in US residential solar deployment, there is limited insight into whether these disparities exist for the non-residential sector. Here we use DeepSolar, a comprehensive photovoltaic database constructed with satellite imagery, to assess solar deployment equity based on the US Justice40’s disadvantaged community measure. We find that disadvantaged communities have less non-residential solar (–38%), but this disparity is notably higher for residential solar (–67%). Across-state variations are consistent for residential solar (–81% to –49%) yet highly heterogeneous for non-residential solar (–66% to +34%). Using scenarios to explore the potential for microgrids powered by solar on building rooftops larger than 1,000 square metres, we estimate that 63% of disadvantaged communities could meet at least 20% of annual residential electricity demand. Furthermore, our research argues for a new focus on non-residential solar as a way to strengthen resilience and accelerate local deployment of clean energy resources to promote energy justice.

14 SOLAR ENERGY↗

Residential Electricity Prices: A Review of Data Sources and Estimation Methods

This paper presents an empirical study of residential electricity prices based on a compilation of tariff data collected for Lawrence Berkeley Lab's Tariff Analysis Project (TAP). We also review other data sources commonly used to estimate residential sector electricity prices, including utility data published by the Energy Information Administration (EIA), the Typical Bills reports published by the Edison Electric Institute, and household-level electricity consumption and expenditure data included with the EIA's Residential Energy Consumption Surveys. We define three different types of price that can be estimated from the data, construct estimation methods, compare the results and evaluate the relative strengths and weaknesses of each approach. We examine several sources of variation including seasonal, regional, industry structure, and the magnitude of baseline household consumption. The tariff data are also used to explore the impact of moving households from standard tariffs to time-of-use pricing, and to summarize how this affects predictions of electricity bill savings for both demand reduction and demand shifting. (auth)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Association rule mining based quantitative analysis approach of household characteristics impacts on residential electricity consumption patterns

The comprehensive understanding of the residential electricity consumption patterns (ECPs) and how they relate to household characteristics can contribute to energy efficiency improvement and electricity consumption reduction in the residential sector. After recognizing the limitations of current studies (i.e. unreasonable typical ECP (TECP) extraction method and the problem of multicollinearity and interpretability for regression and machine learning models), this paper proposes an association rule mining based quantitative analysis approach of household characteristics impact on residential ECPs trying to address them together. First, an adaptive density-based spatial clustering of applications with noise (DBSCAN) algorithm is utilized to create seasonal TECP of each individual customer only for weekdays. K-means is then adopted to group all the TECPs into several clusters. An enhanced Apriori algorithm is proposed to reveal the relationships between TECPs and thirty five factors covering four categories of household characteristics including dwelling characteristics, socio-demographic, appliances and heating and attitudes towards energy. Results of the case study using 3326 records containing smart metering data and survey information in Ireland suggest that socio-demographic and cooking related factors such as employment status, occupants and whether cook by electricity have strong significant associations with TECPs, while attitudes related factors almost have no effect on TECPs. The results also indicate that those households with more than one person are more likely to change ECP across seasons. The proposed approach and the findings of this study can help to support decisions about how to reduce electricity consumption and CO2 emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling and Analysing the Impact of Heat Pump Water Heaters on Distribution Systems Using GridLAB-D

With the constant increase in energy demand, finding ways to reduce peak load and the energy-costs factors has become more imperative. Domestic water heating showcases a significant opportunity for such applications. Water heating is the second-highest energy consumer in the residential sector across the United States. Electric Water Heaters (EWHs), in particular, constitute nearly 43% of American household water heating energy consumption. Heat Pump Water Heater (HPWH), on the other hand, are an advanced water heating technology that has recently emerged in the United States residential market. The objectives of this work are to develop a HPWH model and build a case study that evaluates various penetration levels of HPWH in providing reduced peak load and cost-effective energy savings for both utilities and customers. The HPWH model was developed and integrated within the GridLAB-D simulation environment. The model behavior was then validated against a real HPWH unit at Portland State University (PSU). The case studies incorporated five HPWH penetration levels, ranging from 20% to 100%. In each case, EWHs were replaced with HPWHs. The results showed that a high penetration level of HPWHs can reduce the energy consumption on a distribution system to 38%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Fault Detection & Diagnostics: Residential Market Analysis

This report provides an overview of the market potential for automated fault detection and diagnostics (AFDD) in the residential sector, focusing on embedded AFDD in central air conditioners (CAC) and air-source heat pumps (ASHP) as well as the use of smart diagnostic tools to ensure quality installation of CAC/ASHP equipment. The contents include background on AFDD, stakeholder engagement efforts, a technology assessment of AFDD and smart diagnostic tools, residential CAC and ASHP market trends, a characterization of the CAC and ASHP installed base, a synopsis of utility provider programs, and market barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Laboratory Performance Evaluation of Residential Scale Gas Engine Driven Heat Pump

Building space cooling is, and until 2040 is expected to continue to be, the single largest use of electricity in the residential sector in the United States (EIA Energy Outlook 2015 .) Increases in electric-grid peak demand leads to higher electricity prices, system inefficiencies, power quality problems, and even failures. Thermally-activated systems, such as gas engine-driven heat pump (GHP), can reduce peak demand. This study describes the performance of a residential scale GHP. It was developed as part of a cooperative research and development agreement (CRADA) that was authorized by the Department of Energy (DOE) between OAK Ridge National Laboratory (ORNL) and Southwest Gas. Results showed the GHP produced 16.5 kW (4.7 RT) of cooling capacity at 35 C (95 F) rating condition with gas coefficient of performance (COP) of 0.99. In heating, the GHP produced 20.2 kW (5.75 RT) with a gas COP of 1.33. The study also discusses other benefits and challenges facing the GHP technology such as cost, reliability, and noise.

Abu-Heiba, Ahmad↗

Assessing outdoor air quality and public health impact attributable to residential black carbon emissions in rural China

Black carbon (BC) is a significant component of particulate matter (PM) that relates to air pollution, climate forcing, and further implications for public health. BC is predominantly released from the combustion of solid fuels. Combustion of low-quality fuels in rural China may induce severe respiratory and cardiopulmonary health outcomes for residents, which have however been inadequately assessed. One major reason for the limited understanding is the lack of a high-resolution inventory. An improved method of estimating the BC-associated public health burden is needed. This work quantified premature mortalities due to residential BC emissions in rural China. Domestic BC emissions at 1×1 km resolution were compiled based on previous field investigation, which were further configured for air quality simulation. A chemistry transport model, WRF–CMAQ v5.2, was employed for simulating BC concentrations. The consequent premature mortalities were quantified by a BC-specific concentration-response function (CRF) derived from an epidemiological study. Results show that residential combustion of solid fuel in rural China emitted 648.0 Gg (95%CI: 361.0–965.9) BC in 2014, after dispersion, accounting for 51.8% of annual mean ground-level BC concentration in China. Such impact was most severe in North and Northeast China, and the Sichuan Basin. The further investigation estimated 171,000 (95%CI: 69,000–387,000) premature mortalities that were attributable to exposure to rural residential BC. These findings reveal the major contribution of rural residential BC emissions to air pollution formation and public health impacts. Our findings are anticipated to provide useful information for enacting the next-stage environmental strategy for the residential sector in China.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Coping with residential electricity demand in India’s future – How much can efficiency achieve?

The time when energy-related carbon emissions come overwhelmingly from developed countries is coming to a close. China will soon overtake the United States as the world’s leading emitter of greenhouse gas emissions. Meanwhile, India also seems to be on track to experience rapid long-term economic expansion. With this growth will surely come continued massive growth in energy demand. This paper explores the dynamics of that demand growth for one sector – residential electricity – and the realistic potential for coping with it through efficiency.

Letschert, Virginie↗

Quantifying the economic costs of power outages owing to extreme events: A systematic review

Quantifying the economic cost of long-duration power outages is crucial to justifying investments in resiliency and reliability improvements. However, extensive study on the subject complicates the identification of power outage costs and determining the most suitable approach to quantify them for an individual, specific facility, particularly in the context of extreme events. Here, this research provides a systematic review of economic studies estimating the impact of environmental disasters at the microeconomic and macroeconomic levels. Of 326 articles, evaluating the costs of power outages in extreme events, this work identified 22 studies that attempted to quantify the economic costs. These findings indicate that quantifying power outage costs lacks standardization, posing challenges for comparing different studies. Most analyses aiming to quantify these costs for utilities, sectors, and the overall economy rely on outdated survey data, which offer generalized rather than specific cost estimations. The costs of power outages exhibit a significant dependence on factors such as the sector involved, the type of customer affected, and the outage duration. To quantify industry costs, the research in this study suggests that using the National Renewable Energy Laboratory's online, open-access Customer Damage Function Calculator is the best option for individual-level assessments of industries, hospitals, offices, education centers, and similar facilities. However, the Interruption Cost Estimate Calculator can estimate outage costs across industrial, commercial, and residential sectors for macroeconomic outcomes. Finally, this article discusses the relative strengths of these methods and tools and the potential directions for future research.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗