Summary of FY11 Sulfate Retention Studies for Defense Waste Processing Facility Glass

This report describes the results of studies related to the incorporation of sulfate in high level waste (HLW) borosilicate glass produced at the Savannah River Site (SRS) Defense Waste Processing Facility (DWPF). A group of simulated HLW glasses produced for earlier sulfate retention studies was selected for full chemical composition measurements to determine whether there is any clear link between composition and sulfate retention over the compositional region evaluated. In addition, the viscosity of several glasses was measured to support future efforts in modeling sulfate solubility as a function of predicted viscosity. The intent of these studies was to develop a better understanding of sulfate retention in borosilicate HLW glass to allow for higher loadings of sulfate containing waste. Based on the results of these and other studies, the ability to improve sulfate solubility in DWPF borosilicate glasses lies in reducing the connectivity of the glass network structure. This can be achieved, as an example, by increasing the concentration of alkali species in the glass. However, this must be balanced with other effects of reduced network connectivity, such as reduced viscosity, potentially lower chemical durability, and in the case of higher sodium and aluminum concentrations, the propensity for nepheline crystallization. Future DWPF processing is likely to target higher waste loadings and higher sludge sodium concentrations, meaning that alkali concentrations in the glass will already be relatively high. It is therefore unlikely that there will be the ability to target significantly higher total alkali concentrations in the glass solely to support increased sulfate solubility without the increased alkali concentration causing failure of other Product Composition Control System (PCCS) constraints, such as low viscosity and durability. No individual components were found to provide a significant improvement in sulfate retention (i.e., an increase of the magnitude necessary to have a dramatic impact on blending, washing, or waste loading strategies for DWPF) for the glasses studied here. In general, the concentrations of those species that significantly improve sulfate solubility in a borosilicate glass must be added in relatively large concentrations (e.g., 13 to 38 wt % or more of the frit) in order to have a substantial impact. For DWPF, these concentrations would constitute too large of a portion of the frit to be practical. Therefore, it is unlikely that specific additives may be introduced into the DWPF glass via the frit to significantly improve sulfate solubility. The results presented here continue to show that sulfate solubility or retention is a function of individual glass compositions, rather than a property of a broad glass composition region. It would therefore be inappropriate to set a single sulfate concentration limit for a range of DWPF glass compositions. Sulfate concentration limits should continue to be identified and implemented for each sludge batch. The current PCCS limit is 0.4 wt % SO 4 2- in glass, although frit development efforts have led to an increased limit of 0.6 wt % for recent sludge batches. Slightly higher limits (perhaps 0.7-0.8 wt %) may be possible for future sludge batches. An opportunity for allowing a higher sulfate concentration limit at DWPF may lay lie in improving the laboratory experiments used to set this limit. That is, there are several differences between the crucible-scale testing currently used to define a limit for DWPF operation and the actual conditions within the DWPF melter. In particular, no allowance is currently made for sulfur partitioning (volatility versus retention) during melter processing as the sulfate limit is set for a specific sludge batch. A better understanding of the partitioning of sulfur in a bubbled melter operating with a cold cap as well as the impacts of sulfur on the off-gas system may allow a higher sulfate concentration limit to be established for the melter feed. This approach would have to be taken carefully to ensure that a sulfur salt layer is not formed on top of the melt pool while allowing higher sulfur based feeds to be processed through DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced diffusion and enhanced retention of multiple radionuclides from pore structure characterization of barrier materials for enhanced repository performance

Fluid flow and chemical transport in porous media are the macroscopic consequences of pore structure, which integrates geometry (e.g., pore size and surface area, pore-size distribution) and topology (e.g., pore connectivity). Low-permeability geological media whose pores are poorly interconnected will exhibit the characteristics of anomalous diffusion and sample size-dependent effective porosity, which will strongly impact long-term net diffusion and retention of radionuclides in geological repository settings involving different host rocks and barrier materials. A suite of innovative and complementary experimental approaches is utilized to study the microscopic pore structure and macroscopic fluid flow & chemical transport for a range of host rocks and barrier materials, in addition to standard clay minerals and reference rocks. With a particular focus on quantifying the presence and magnitude of “isolated” pores for a reduced effective porosity in low-permeability geomedia, the integrated methodologies for basic properties and pore structure characterization of these geomedia include X-ray diffraction, thin section petrography, grain size distribution, water immersion porosimetry after vacuum-pulling for full saturation, mercury intrusion porosimetry, nitrogen physisorption, scanning electron microscopy, X-ray computed tomography, and (ultra-)small angle neutron (X-ray) scattering. In addition, custom-designed gas diffusion, tracer recipe involving a range of anionic and cationic chemicals with subsequent analyses by laser ablation and inductively coupled plasma-mass spectrometry, along with batch sorption, column transport, and imbibition tests were conducted for coupled effects of pore structure and chemical retention/transport. From the perspectives of pore structure in conjunction with multiple and complementary approaches to examining a range of sample sizes under different observational scales, we find that the poor pore connectivity is prevalent in low-permeability media (mudstone and crystalline rock) that is related to geological processes (e.g., compaction, diagenesis and thermal maturation). For example, the deep and organic matter-rich mudstones have a much smaller effective porosity than the total porosity (as a result of poor pore connectivity) and associated diffusion coefficient, and the effective porosity & diffusion coefficients are also dependent upon the sample sizes used in the measurement. Similarly, most of the pore space in the shallow mudstone is also controlled by pore-throat diameters in the 5-50 nm range of intergranular pore types from its fine-grained nature, but with an overall good pore connectivity. However, the nm-sized pore space (physically pore-network architecture) and strong sorption capacities (chemical retention from clay minerals) of both shallow and deep mudstones lead to the synergistic retention of cationic radionuclides and their utilities as effective host rocks and barrier materials. Our unique approaches of studying how the micro-scale pore structure affect macro-scale fluid flow, diffusion & retention, and chemical transport produce improved mechanistic understanding, and realistic quantification, of diffusion and retention of typical radionuclides in a range of generic host rocks and barrier materials (clay/shale, salt, crystalline rock, and tuff), with the overall results leading to scientifically-based understanding of enhanced isolation (from both diffusion and retention) of radionuclides and improved confidence on the long-term performance of geological repository to store high-level radioactive wastes. In addition to the training of 25 undergraduates, graduates, and postdocs of UTA, the scientists (organizations) involved in performing this work (e.g., discussion, sample sharing, and operation of SANS and SAXS instruments) include Ed Matteo, Yifeng Wang, and Kristopher Kuhlman (Sandia National Laboratories), Jens Birkholzer, Liange Zheng, Tim Kneafsey, and Sharon Borglin (Lawrence Berkeley National Laboratory), Mavrik Zavarin (Lawrence Livermore National Laboratory), Yukio Tachi and Yuta Fukatsu (Japan Atomic Energy Agency), Mieke de Craen (Euridice, Belgium), Markus Bleuel (NIST), Wei-Ren Chen, Gergely Nagy, Changwoo Do, William Heller, Larry Anovitz, and Kenneth Littrell (ORNL), as well as Jan Illvsky, Ivan Kuzmenko, Ju-Sang Park and Jon Almers (ANL). Key deliverables include a total of 13 peer-reviewed journal articles (nine published and three under review), 23 presentations at scientific conferences (AAPG, AAPG Southwest Section, AGU, Asian Clay Conference, GSA, GSA South-Central Section, IHLRWM, InterPore, International Conference on Chemistry and Migration Behavior of Actinides and Fission Products in the Geosphere, International Conference on Coupled Processes in Fractured Geological Media: Observation, Modeling and Application), and academic institutions (UTA, New Mexico State University; University of Poitiers, France; University of Helsinki, Finland; Uppsala University, Sweden; Istanbul Technical University, Turkey) and other organizations (Andra, France; Posiva Oy, Finland).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Behavior of deuterium retention and surface morphology for VPS–W/F82H

The deuterium (D) retention for Vacuum Plasma Spray (VPS)–tungsten (W)/F82H was studied using two different implantation methods, namely D plasma exposure and View the MathML source implantation. The D retention for polished VPS–W/F82H after plasma exposure was found to be reduced compared to that for polycrystalline tungsten. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) observations indicated that porous structures around grain boundaries and the interface between VPS–W layers would be potential D diffusion paths, leading to low D retention. In the case of View the MathML source implantation, the shape of D2 TDS spectrum was almost the same as that for D plasma-exposed VPS–W/F82H; however, the D retention was quite high for unpolished VPS–W/F82H, indicating that most of D was trapped by the oxide layer, which was produced by the VPS process. The reduction of surface area due to the polishing process also reduces D retention for VPS–W/F82H. These results indicate that controlling the surface chemical states is important for the reduction of tritium retention for future fusion reactors.

99 GENERAL AND MISCELLANEOUS↗

Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children <5 y of age. To explore possible reasons for the lack of response to HD-VAS among Zambian children, we quantified the absorption, retention, and urinary elimination of either a single HDVAS (60 mg) or a smaller dose of stable isotope (SI)-labeled VA (5 mg), which was used to estimate VA pool size, in 3-4 y old Zambian boys (n = 4 for each VA dose). A 25 nCi tracer dose of [{sup 14}C{sub 2}]-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of {sup 14}C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting {sup 14}C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 {+-} 7.1%, 76.3 {+-} 6.7%, and 1.9 {+-} 0.6%/d, respectively, for the HD-VAS and 76.5 {+-} 9.5%, 71.1 {+-} 9.4%, and 1.8 {+-} 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

59 BASIC BIOLOGICAL SCIENCES↗

Progress Summary: 12-Month Compression Set and Load Retention of Thermally Accelerated Aged Siloxane Specimens (Additively Manufactured by the Direct-Ink-Write (DIW) 3D Printing Technique) Was Measured

Motivation: Accelerated aging of polymeric materials is needed to predict their long-term mechanical functionality. Two key metrics used to evaluate their performance are compression set and load retention. A baseline(time=0)mechanical assessment was done prior to initiating the accelerated aging process to acquire initial thickness and load values for future calculation of compression set and load retention.Specimens are beingaged under compressive strain (13%for the current studies) at four different temperatures (25, 40, 55, and 70°C) for at least 1 year; compression set and load retention will be measured at various timepoints. Time-temperature superposition (TTS) will be applied to the isothermal data to obtain long-term predictions. Significance: Compression set is increasing with time and temperature, as expected. The increasing compression set is accompanied by decreasing load retention.The relativelylow compression set indicates the material is performing well.In a previous aging study, the legacy S5370 RTV foam exhibited 40% relative compression set after 12 months at 70°C, which is more than twice that of the DIW material. Progress:Data has been acquired out to the 12-month timepoint. Relative compression set and load retention versus time are shown in Fig. 1.A technical issue with the method of measuring load retention was discovered and previously reported load retention values have been adjusted; the current load retention values are estimates. TTS predictions are shown in Fig. 2.

36 MATERIALS SCIENCE↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

The Association of Age-Related and Off-Target Retention with Longitudinal Quantification of [ 18 F]MK6240 Tau PET in Target Regions

6-(fluoro- 18 F)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([ 18 F]MK6240) tau PET tracer quantifies the brain tau neurofibrillary tangle load in Alzheimer disease. The aims of our study were to test the stability of common reference region estimates in the cerebellum over time and across diagnoses and evaluate the effects of age-related and off-target retention on the longitudinal quantification of [ 18 F]MK6240 in target regions. Methods: We assessed reference, target, age-related, and off-target regions in 125 individuals across the aging and Alzheimer disease spectrum with longitudinal [ 18 F]MK6240 SUVs and SUV ratios (SUVRs) (mean ± SD, 2.25 ± 0.40 y of follow-up). We obtained SUVR from meninges, exhibiting frequent off-target retention with [ 18 F]MK6240. Additionally, we compared tracer uptake between 37 cognitively unimpaired young (CUY) (mean age, 23.41 ± 3.33 y) and 27 cognitively unimpaired older (CU) adults (amyloid-β–negative and tau-negative, 58.50 ± 9.01 y) to identify possible nonvisually apparent, age-related signal. Two-tailed t testing and Pearson correlation testing were used to determine the difference between groups and associations between changes in region uptake, respectively. Results: Inferior cerebellar gray matter SUV did not differ on the basis of diagnosis and amyloid-β status, cross-sectionally and over time. [ 18 F]MK6240 uptake significantly differed between CUY and CU adults in the putamen or pallidum (affecting ~75% of the region) and in the Braak II region (affecting ~35%). Changes in meningeal and putamen or pallidum SUVRs did not significantly differ from zero, nor did they vary across diagnostic groups. We did not observe significant correlations between longitudinal changes in age-related or meningeal off-target retention and changes in target regions, whereas changes in all target regions were strongly correlated. Conclusion: Inferior cerebellar gray matter was similar across diagnostic groups cross-sectionally and stable over time and thus was deemed a suitable reference region for quantification. Despite not being visually perceptible, [ 18 F]MK6240 has age-related retention in subcortical regions, at a much lower magnitude but topographically colocalized with significant off-target signal of the first-generation tau tracers. The lack of correlation between changes in age-related or meningeal and target retention suggests little influence of possible off-target signals on longitudinal tracer quantification. Nevertheless, the age-related retention in the Braak II region needs to be further investigated. Future postmortem studies should elucidate the source of the newly reported age-related [ 18 F]MK6240 signal, and in vivo studies should further explore its impact on tracer quantification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fuel nozzle tube retention

A system for retaining a fuel nozzle premix tube includes a retention plate and a premix tube which extends downstream from an outlet of a premix passage defined along an aft side of a fuel plenum body. The premix tube includes an inlet end and a spring support feature which is disposed proximate to the inlet end. The premix tube extends through the retention plate. The spring retention feature is disposed between an aft side of the fuel plenum and the retention plate. The system further includes a spring which extends between the spring retention feature and the retention plate.

42 ENGINEERING↗

Effect of rhenium addition on deuterium retention in neutron-irradiated tungsten

In this work, the effects of rhenium (Re) addition on deuterium (D) retention in neutron-irradiated tungsten (W) were investigated. Pure W and W-5Re (5 at.%) alloy samples were irradiated with neutrons at High Flux Isotope Reactor using MFE-RB-19 J capsule. The sample temperature and the damage level were 864 K and 0.35 dpa for pure W and 792 K and 0.26 dpa for W-5Re alloy. A portion of the samples was exposed to D plasma at Tritium Plasma Experiment at Idaho National Laboratory at 823 K to a fluence of 5 × 1025 m -2 . Vacancy-type defects in neutron-irradiated samples were examined using positron annihilation spectroscopy (PAS); D retention after plasma exposure was evaluated by thermal desorption spectrometry (TDS). TDS measurements revealed that D retention in the neutron-irradiated W-5Re alloy was similar to that in the unirradiated W sample, whereas a significant increase in D retention was observed in neutron-irradiated W. Thus, Re addition significantly suppressed the increase in D retention after neutron irradiation. This effect was attributed to the suppression of vacancy-type defect formation, as confirmed by PAS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strong-Sludge Gas Retention and Release Mechanisms in Clay Simulants

The Hanford Site has 28 double-shell tanks (DSTs) and 149 single-shell tanks (SSTs) containing radioactive wastes that are complex mixes of radioactive and chemical products. The mission of the Department of Energy's River Protection Project is to retrieve and treat the Hanford tank waste for disposal and close the tank farms. A key aspect of the mission is to retrieve and transfer waste from the SSTs, which are at greater risk for leaking, into DSTs for interim storage until the waste is transferred to and treated in the Waste Treatment and Immobilization Plant. There is, however, limited space in the existing DSTs to accept waste transfers from the SSTs, and approaches to overcoming the limited DST space will benefit the overall mission. The purpose of this study is to summarize and analyze the key previous experiment that forms the basis for the relaxed controls and to summarize progress and results on new experiments focused on understanding the conditions that result in low gas retention. The previous large-scale test used about 50 m3 of sediment, which would be unwieldy for doing multiple parametric experiments. Accordingly, experiments began with smaller-scale tests to determine whether the desired mechanisms can be studied without the difficulty of conducting very large experiments. The most significant results from the current experiments are that progressively lower gas retention occurs in tests with progressively deeper sediment layers and that the method of gas generation also affects the maximum retention. Based on the results of this study, it is plausible that relatively low gas retention could occur in sufficiently deep tank waste in DSTs. The current studies and previous work, however, have not explored how gas retention and release will behave when two or more layers with different properties are present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intraosseous Venography with Carbon Dioxide in Percutaneous Vertebroplasty: Carbon Dioxide Retention in Renal Veins

The objective of the present study was to determine the frequency of gas retention in the renal vein following carbon dioxide intraosseous venography in the prone position and, while citing references, to examine its onset mechanisms. All percutaneous vertebroplasties performed at our hospital from January to December 2005 were registered and retrospectively analyzed. Of 43 registered procedures treating 79 vertebrae, 28 procedures treating 54 vertebrae were analyzed. Vertebral intraosseous venography was performed using carbon dioxide as a contrast agent in all percutaneous vertebroplasty procedures. In preoperative and postoperative vertebral CT, gas retention in the renal vein and other areas was assessed. Preoperative CT did not show gas retention (0/28 procedures; 0%). Postoperative CT confirmed gas retention in the renal vein in 10 of the 28 procedures (35.7%). Gas retention was seen in the right renal vein in 8 procedures (28.6%), in the left renal vein in 5 procedures (17.9%), in the left and right renal veins in 3 procedures (10.7%), in vertebrae in 22 procedures (78.6%), in the soft tissue around vertebrae in 14 procedures (50.0%), in the spinal canal in 12 procedures (42.9%), and in the subcutaneous tissue in 5 procedures (17.9%). In conclusion, in our study, carbon dioxide gas injected into the vertebra frequently reached and remained in the renal vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Water retention and gas relative permeability of two industrial concretes

This experimental study aims at identifying the water retention properties of two industrial concretes to be used for long term underground nuclear waste storage structures. Together with water retention, gas transfer properties are identified at varying water saturation level, i.e. relative gas permeability is assessed directly as a function of water saturation level S{sub w}. The influence of the initial de-sorption path and of the subsequent re-saturation are analysed both in terms of water retention and gas transfer properties. Also, the influence of concrete microstructure upon water retention and relative gas permeability is assessed, using porosity measurements, analysis of the BET theory from water retention properties, and MIP. Finally, a single relative gas permeability curve is proposed for each concrete, based on Van Genuchten-Mualem's statistical model, to be used for continuous modelling approaches of concrete structures, both during drying and imbibition.

36 MATERIALS SCIENCE↗

The influence of helium on deuterium retention in beryllium co-deposits

Tritium co-deposition with materials from the plasma-facing components is expected to be the main contributor to tritium retention in ITER. Since He will also be present in the plasma as fusion ash during the DT campaign, this study focuses on the effect of He on D retention in Be co-deposits. The PISCES-B linear plasma device was used to create co-deposited Be-D-He layers for various deposition temperatures (295 K - 475 K) and He concentrations in D - αHe plasma mixtures (0 ≤ α ≤ 0.1). Thermal desorption spectroscopy and nuclear reaction analysis were used to determine the D concentration in co-deposits. For the lowest He concentration (1%) an increase of D retention was observed for the deposition at room temperature, whereas for higher He concentrations a declining trend of D retention was found. Including 10% of He in the plasma is found to reduce D retention at deposition temperatures below 425 K and have a negligible effect at higher deposition temperatures.

36 MATERIALS SCIENCE↗

Deuterium retention in pre-lithiated samples and Li–D co-deposits in the DIII-D tokamak

Divertor designs involving liquid lithium have been proposed as an alternative to solid designs and wall conditioning techniques. However, Li affinity with tritium poses a risk for the fuel cycle. This study investigates deuterium retention in pre-lithiated samples and Li–D co-deposits in the DIII-D tokamak, making for the first time a direct comparison between Li–D co-deposits and pre-deposited Li films. Samples were exposed to H-mode plasmas in the far scrape-off layer (SOL), and Li powder was injected in-situ with the impurity powder dropper to study the uniformity of Li coatings, and the dependence of fuel retention on Li thickness. The results show that at temperatures below the melting point of lithium, deuterium retention is independent of the thickness of pre-deposited Li layers, with Li–D co-deposits being the primary factor for fuel retention. Both pre-deposited and in-situ deposited Li showed lower erosion than predicted by sputtering yield calculations. These results suggest that fuel retention in fusion reactors using lithium in the divertor will likely be dominated by co-deposits rather than in the divertor itself. If one desires to use Li to achieve flatter temperature profiles, operando Li injection is advantageous over pre-deposited Li films, at least at temperatures below the melting point of lithium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Influence of Microstructure on Deuterium Retention in Polycrystalline Tungsten

The retention of hydrogen isotopes in the plasma-facing materials of a fusion reactor is dependent on the density of trapping sites in the material. One factor that can influence the trapping defects is the surface state of the material before exposure. Mechanically polished, electropolished, and recrystallized tungsten samples were compared by exposing them to 350 eV D + beams with peak fluences of ~1 × 10 24 D + /m 2 at 500 and 740 K at the Multicharged Ion Research Facility (MIRF). At the exposure temperature of 740 K, no significant retention was detected. For material exposed at 500 K, significant differences in retention were observed, and the order of increasing retention was recrystallized, electropolished, and mechanically polished. Lastly, the other variable besides surface treatment was the time delay between ion exposure and thermal desorption spectroscopy which also may have impacted the retention measurements if there was out-gassing of the D while samples were in storage before thermal desorption spectroscopy (TDS).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of a Cr-rich surface layer on D retention in various RAFM steels

In this work, deuterium (D) retention is compared between various reduced-activation ferritic/martensitic steels, including CLF-1, Eurofer, F82H, and Rusfer, exposed to pure D plasma (ion flux ~1.5–2 × 10 21 m -2 s -1 , fluence, &straightphi; D , ~1 × 10 25 m -2 , sample temperature ~373 K, and incident ion energy ~100 eV). It is found that there is a large difference (up to ~30x) in the D retention between CLF-1 and F82H even with the same plasma exposure condition and similar nominal composition. The &straightphi; D dependence of the D retention exhibits a peculiar, counterintuitive feature: the D retention decreases with an increase in &straightphi; D from 2 × 10 23 m -2 to 1 × 10 25 m -2 . Surface analyses reveal that a Cr-rich surface layer is formed during outgassing at 773 K for 1 h before plasma exposure, and that there exists a clear correlation between the D retention and the Cr content in the surface layer.

36 MATERIALS SCIENCE↗

Oxygen plasma immersion ion implantation treatment to enhance data retention of tungsten nanocrystal nonvolatile memory

Data retention characteristics of tungsten nanocrystal (W-NC) memory devices using an oxygen plasma immersion ion implantation (PIII) treatment are investigated. With an increase of oxygen PIII bias voltage and treatment time, the capacitance–voltage hysteresis memory window is increased but the data retention characteristics become degraded. High-resolution transmission electron microscopy images show that this poor data retention is a result of plasma damage on the tunneling oxide layer, which can be prevented by lowering the bias voltage to 7 kV. In addition, by using the elevated temperature retention measurement technique, the effective charge trapping level of the WO{sub 3} film surrounding the W-NCs can be extracted. This measurement reveals that a higher oxygen PIII bias voltage and treatment time induces more shallow traps within the WO{sub 3} film, degrading the retention behavior of the W-NC memory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Order-of-magnitude differences in retention of low-energy Ar implanted in Si and SiO{sub 2}

The retention of 1 and 5 keV Ar implanted at 45° in Si and 4.3 nm SiO{sub 2} on Si was studied at fluences between 3 × 10{sup 14} and 1.5 × 10{sup 16} cm{sup −2}. X-ray photoelectron spectroscopy (XPS) served to monitor the accumulation of Ar as well as the removal of SiO{sub 2}. Bombardment induced changes in oxygen chemistry caused the O 1s peak position to move toward lower binding energies by as much as 2.2 eV. Plotted versus depth of erosion, the fluence dependent changes in oxygen content, and peak position were similar at 1 and 5 keV. The Ar content of Si increased with increasing exposure, saturating at fluences of ∼2 × 10{sup 15} cm{sup −2} (1 keV) and ∼6 × 10{sup 15} cm{sup −2} (5 keV). Much less Ar was retained in the SiO{sub 2}/Si sample, notably at 1 keV, in which case the low-fluence Ar signal amounted to only 8% of the Si reference. The results imply that essentially no Ar was trapped in undamaged SiO{sub 2}, i.e., the Ar atoms initially observed by XPS were located underneath the oxide. At the lowest fluence of 5 keV Ar, the retention ratio was much higher (43%) because the oxide was already highly damaged, with an associated loss of oxygen. The interpretation was assisted by TRIM(SRIM) calculations of damage production. Partial maloperation of the ion beam raster unit, identified only at a late stage of this work, enforced a study on the uniformity of bombardment. The desired information could be obtained by determining x,y line scan profiles of O 1s across partially eroded SiO{sub 2}/Si samples. Fluence dependent Ar retention in Si was described using an extended version of the rapid relocation model which takes into account that insoluble implanted rare-gas atoms tend to migrate to the surface readily under ongoing bombardment. The range parameters required for the modeling were determined using TRIM(SRIM); sputtering yields were derived from the literature. The other three parameters determining the Ar signal, i.e., (1) the thickness w of the near-surface Si region devoid of Ar, (2) the relocation efficiency Ψ{sub rlc}, and (3) the effective attenuation length L in XPS analysis were varied within reasonable limits until the calculated retention curves for 1 and 5 keV Ar in Si agreed with experimental data to better than 8%, using the same XPS sensitivity factor throughout. Results: w = 1.4 ± 0.1 nm, Ψ{sub rlc} = 6.6 ± 0.5, and L = 2.7 ± 0.2 nm. Combining experimental and calculated data, it was found that the Ar trapping efficiency of the damaged oxide is intimately correlated with the loss of oxygen. The calculated stationary areal densities of all retained Ar are compared with results obtained by high-resolution medium-energy ion scattering spectrometry. Attractive areas of future research in rare gas retention and nanobubble formation are sketched briefly.

42 ENGINEERING↗