We present simulations and experimental progress toward the development of a high-current electron source with the potential to deliver high charge electron bunches at GHz-level repetition rates. To achieve these goals electrons are generated through field-emission and the cathode is immersed in a conduction-cooled superconducting 650-MHz RF cavity. The field-emitters consist of microscopic silicon pyramids and have a typical enhancement factor of about 500. To trigger field-emission, the peak field inside the RF cavity of about 6 MV/m is further enhanced by placing the field-emitters on the top of a superconducting Nb rod inserted in the RF cavity. So far, we cannot control the duration of the electron bunches which is of the order of RF period. Also, the present cryo-cooler power of about 2 W limits the beam current to microamp level.
Calabazas Creek Research, Inc. (CCR) and its collaborators are developing high efficiency, low cost RF sources. Phase and Amplitude Controlled Magnetrons: CCR, Fermilab, and Communications & Power Industries, LLC (CPI) recently developed a 100 kW, 1.3 GHz magnetron system with amplitude and phase control. The system operated at more than 80% efficiency and demonstrated rapid control of amplitude and phase. Multiple Beam Triodes: CCR, in collaboration with CPI and JP Accelerator Works, Inc., is developing 200 kW, pulsed and CW RF sources from 350 to 700 MHz with projected efficiencies exceeding 80% and cost of $0.50/Watt. Prototype tubes are scheduled for tests in spring 2021. High Efficiency Klystrons:CCR, CPI, and Leidos, Inc. are building a 1.3 GHz, 100 kW klystron operating at 80% efficiency. High power testing is scheduled for summer 2021. Multiple Beam IOTs: CCR and Georgia Tech Research Institute are developing MBIOTs with simplified input coupling and high efficiency. Simulations indicate that 3rd harmonic drive power can increase the efficiency 8-10 %. The program is developing a prototype tube to produce 200 kW peak, 100 kW average power at 704 MHz.
We present the design and performance of a four-phased radiofrequency (RF) carpet system for ion transport between 200–600 mbar, significantly higher than previously demonstrated RF carpet applications. The RF carpet, designed with a 160 μm pitch, is applied to the lateral collection of ions in xenon at pressures up to 600 mbar. We demonstrate transport efficiency of caesium ions across varying pressures, and compare with microscopic simulations made in the SIMION package. The novel use of an N-phased RF carpet can achieve ion levitation and controlled lateral motion in a denser environment than is typical for RF ion transport in gases. This feature makes such carpets strong candidates for ion transport to single ion sensors envisaged for future neutrinoless double-beta decay experiments in xenon gas.
The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.
The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.
Effective resonance control of superconducting radio frequency (SRF) cavities is critical for large machines like LCLS-II, as failure to achieve proper control can result in increased RF power consumption, higher cryogenic heat loads, and increased costs. To address this challenge, we have developed a machine learning (ML) model based on the dynamic mode decomposition method to represent the forced cavity dynamics. Using this model, we designed a model predictive controller (MPC) and demonstrated through simulation that the MPC can effectively stabilize the amplitude and phase of SRF cavities using only a frequency actuator, even in the presence of multiple mechanical modes. The lightweight and explicit ML model makes the controller suitable for direct implementation on field-programmable gate arrays, unlocking the full potential of SRF linacs like LCLS-II, enabling higher beam power and energy, and also serving as an advanced motion controller for various applications, such as photon beamlines and storage rings.
While a demonstration of TW resonance excitation in the 3-cell structure in 2K liquid helium had been prepared and carried out at Fermilab in collaboration with Euclid Techlabs, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab as the next step of TW development towards an accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing), Fermilab has proposed a half-meter scale TW RF design consisting of a 7-cell structure and a power feedback waveguide (WG) loop. The WG loop design includes the new RF configurations for TW resonance control during a high-power operation. 1-year US-Japan collaboration program focused on EBW optimization for the TW shape iris joint within the narrow gap was awarded and the efforts has been made by Fermilab, Jlab, and KEK. 1-year LDRD program of Fermilab is awarded recently to fabricate a low-cost mockup of the WG loop with new RF configurations and validate them. Here we will present a preliminary 7-cell TW RF design and will report the progress and challenges through the programs awarded.
A superconducting radio-frequency photo-injector cryomodule is being developed for the high-energy upgrade of the Linac Coherent Light Source (LCLS-II-HE). This effort is a collaboration between the Facility for Rare Isotope Beams at Michigan State University (MSU), Argonne National Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, and SLAC National Accelerator Laboratory. The cryomodule features a 185.7 MHz superconducting quarter-wave resonator (QWR) designed to operate with an RF electric field of 30 MV/m at the photo-cathode. Mechanical vibrations must be controlled for operation with stable amplitude and phase. The first prototype cryomodule was cold-tested at MSU with a QWR, fundamental power coupler, tuner, and cathode stalk. In the cold test, we observed microphonics that made it difficult to control the RF phase at high gradient. The cryogenic circuit was identified as a likely culprit. This paper presents our studies of microphonics during the cryomodule cold test and follow-up investigations at room temperature. Our findings provided valuable feedback for modifications to the cryogenic circuit and a successful second cold test of the cryomodule.
Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become “standard” components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.
Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become "standard" components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.
This program studied the two-gap nature of magnesium diboride and its possible effects on the superconducting rf properties of this material. Magnesium diboride (MgB 2 ) is a BCS superconductor with a superconducting critical temperature of 39 K, high critical current density and no weak link behavior across the grain boundary. These properties make this material ideal for both power applications and electronic devices. In particular, the high superconducting critical temperature and high thermodynamic field suggests that MgB 2 could be an ideal material also for superconducting radio frequency (SRF) cavities operating at a much higher temperature than Nb cavities and, therefore, reducing noticeably the cryogenics costs. However, MgB 2 is a two gap superconductor and it has been suggested that the RF properties are dominated by the smaller gap, which would make this material not competitive with Nb and especially Nb 3 Sn. The main problem does not seem to be the double-gap nature of this material but rather the weak-coupling of the two gaps that in the presence of an RF field suppresses superconductivity all together at fields much lower than the thermodynamic field. The main goal of this proposal is to address the fundamental question of the coupling between the two gaps in MgB 2 and understand if it is possible to control it and ultimately improve the RF performance of MgB 2 . The project studied these questions by measuring the density of states in the presence of an in-plane current and focused on the effect of controlled disorder. Disorder, indeed, provides an important knob to tune the properties of MgB2 and provides the possibility of changing the coupling between the two bands, making this material a competitive material for SRF applications.
PIP-II is a superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of cavities with five different acceleration \(β\). The LLRF system for the linac has to provide field and resonance control for a total of 125 RF cavities. Various components of the LLRF system have been tested with and without beam at the PIP-II test stands. The LLRF system design is derived from the LCLS-II project with its self-excited loop architecture used in the majority of the cryo-modules. The PIP-II beam loading at 2 mA is much higher than the LCLS-II linac. The control system architecture is analyzed and evaluated for the operational limits of feedback gains and their ability to meet the project regulation requirements for cavity field amplitude and phase regulation.
CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.
PIP-II is an 800 MEV superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an ion source, RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of five different acceleration \(\beta\). The LLRF system for the LINAC has to provide field and resonance control for a total of 125 RF cavities.The LLRF system design is in the final design review phase and will enter the production phase next year. The PIP-II project is an international collaboration with various partner labs contributing subsystems. The LLRF system design for the PIP-II Linac is presented and the specification requirements and system performance in various stages of testing are described in this paper.
This work presents an automated control system for the synthesis of nanomaterials by plasma-enhanced chemical vapor deposition (PECVD), implemented using the LabVIEW software environment. The main objective of the study is to develop an integrated hardware-software platform that enables sequential control of the key stages of the PECVD process, including vacuum chamber preparation, pressure monitoring, working gas supply, plasma ignition, power matching, cyclic nanomaterial growth, and optical monitoring of nanoparticles in the plasma environment. The use of LabVIEW made it possible to integrate actuator control, experimental parameter acquisition, and realtime process visualization within a single automated system. The automated cycle begins with evacuation of the reaction chamber to a predefined base pressure. Transition to the next stage is permitted only after the specified pressure threshold has been reached, ensuring reproducible initial conditions for each experiment. The program then controls the supply of the working gas through mass flow controllers (MFCs). In this work, two gas-flow control modes were considered: analog control using a 0-5 V voltage signal and digital communication via RS-232 interface. It was shown that the analog approach requires accurate scaling of the control voltage, since applying 5 V corresponds to full-scale opening of the controller and results in the maximum gas flow. In contrast, the RS232 interface enables the gas flow rate to be specified directly in sccm, improving the accuracy, flexibility, and convenience of gas-environment control. After pressure stabilization, LabVIEW initiates RF plasma ignition and executes the RF matching algorithm aimed at minimizing reflected power and improving the stability of the plasma process. A separate software module implements the cyclic nanomaterial growth mode, in which the plasma-on time, plasma duration, and total number of synthesis cycles are predefined. This approach makes it possible to control material accumulation on the substrate and to correlate the process parameters with the morphological characteristics of the resulting nanostructures. The final module of the system is designed for optical monitoring of the nanoparticle cloud density in dusty plasma. For this purpose, the change in the intensity of laser radiation passing through the plasma region is recorded using a photodetector and a Keithley 2401 measuring unit connected to LabVIEW via RS-232 interface. The difference between the initial and modified optical signal intensity is used as a diagnostic parameter characterizing the formation and temporal evolution of nanoparticles. The developed system demonstrates that LabVIEW can be effectively applied not only for the automation of individual instruments, but also for the implementation of a complete digital control cycle for PECVD-based nanomaterial synthesis.
We report on recent research on high-gradient radio frequency (RF) accelerating structures indicates that the use of hard copper alloys provides improvement in high gradient performance over annealed copper. Such structures are made by bonding individually manufactured parts. However, there are no well-established bonding techniques that preserve the hardness, surface finish and cleanliness required for high gradient operation. To preserve the copper hardness, RadiaBeam has developed a novel high-gradient split accelerating structure, based on electron beam welding joining technique. This technique provides efficient bonding with strong, clean welds and minimal thermal loading, while maintaining a clean inner RF environment. Our RF design and fabrication methodology limits the small heat affected zone to the outer cavity envelop, with virtually no distortions or thermal loading of critical RF surfaces. It also incorporates provisions to precisely control the gap despite conventional issues with weld joint shrinkage. To date we have manufactured and validated an RF accelerating structure joined by electron-beam welding that incorporates a novel open split design to significantly reduce the assembly complexity and cost. In this paper, we will present the electromagnetic design of this structure, discuss bonding, and present the results of high-power tests, where the accelerating gradients of 140 MV m -1 with surface peak fields of 400 MV m -1 were achieved for flat-top pulse length of 600 ns with an RF breakdown rate of 10 -4 1/(pulsecm).
Electron transport layers (ETLs) used as components of photocathodes for light-driven CO 2 reduction (CO 2 R) in aqueous media should have good electronic transport, be stable under CO 2 R conditions, and, ideally, be catalytically inert for the competing hydrogen evolution reaction (HER). Here, using planar p-Si (100) as the absorbing material, we show that TaO x satisfies all three of the above criteria. TaO x films were synthesized by both pulsed laser deposition (PLD) and radio-frequency (RF) sputtering. In both cases, careful control of the oxygen partial pressure during growth was required to produce ETLs with acceptable electron conductivity. p-Si/TaO x photocathodes were interfaced with ca. 10 nm of a CO 2 R catalyst: Cu or Au. Under front illumination with simulated AM 1.5G in CO 2 -saturated bicarbonate buffer, we observed, for both metals, faradaic efficiencies for CO 2 R products of ~50% and ~30% for PLD TaO x and RF sputtered TaO x , respectively, at photocurrent densities up to 8 mA cm -2 . p-Si/TiO 2 /Cu photocathodes were also evaluated but produced mostly H 2 (>97%) due to reduction of the TiO 2 to Ti metal under CO 2 R conditions. In contrast, a dual ETL photocathode (p-Si/TiO 2 /TaO x /Cu) was selective for CO 2 R, which suggests a strategy for separately optimizing selective charge collection and the stability of the ETL/water interface. The maximum photovoltage obtained with p-Si/TaO x /Cu devices was 300 mV which was increased to 430–460 mV by employing ion implantation to make pn + -Si/TaO x /Cu structures. Photocathodes with RF sputtered TaO x ETLs are stable for CO 2 R for at least 300 min. In conclusion, techno-economic analysis shows that the reported system, if scaled, could allow for an economically viable production of feedstocks for chemical synthesis under the adoption of specific CO 2 credit schemes, thus becoming a significant component of carbon-neutral manufacturing.