Search NASA⌕ Search

SEARCH · Search NASA

Results for “RPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SOX2-driven enhancer landscape defines the transcriptional architecture of retinogenesis

Retinal neurogenesis is mediated by the coordinated activities of a complex gene regulatory network (GRN) of transcription factors (TFs) in multipotent retinal progenitor cells (RPCs). How this GRN mechanistically guides neural competence remains poorly understood. In this study, we present integrated transcriptional, genetic and genomic analyses to uncover the regulatory mechanisms of SOX2, a key factor in establishing neural identity in RPCs. We show that SOX2 is preferentially enriched in the RPC-specific enhancer landscape associated with essential regulators of retinogenesis. Disruption of SOX2 expression impairs retinogenesis, marked by a selective loss of enhancer activity near genes essential for RPC proliferation and lineage specification. We identified the RPC transcription factor VSX2 as a binding partner for SOX2 and, together, SOX2 and VSX2 co-target a core, retina-specific chromatin repertoire characterized by enhanced TF binding and robust chromatin accessibility. This cooperative binding establishes a shared SOX2-VSX2 transcriptional code that promotes the expression of crucial regulators of neurogenesis while repressing the acquisition of alternative lineage cell fate. Our data illuminate fundamental biological insights on how transcription factors act in concert to drive chromatin-based genetic programs underlying retinal neural identity.

Chromatin↗

HFTS-2 Completions Design and State-of-the-Art Diagnostics Results

Various completion schemes were tested as part of the Hydraulic Fracture Test Site-2 (HFTS-2) project. The wells were instrumented with permanent fiber optic (FO) cable, and unique near-wellbore and far-field region surveys were acquired to evaluate spatial and temporal hydraulic fracture characteristics. The state-of-the-art diagnostics included substantial monitoring of both the well stimulation and longer-term production performance. The objective was to evaluate and improve stimulation distribution effectiveness (SDE) for different completion designs based on the diagnostics results. A hydraulic fracturing (HF) profile (i.e., proppant/fluid allocation among clusters) was obtained using near-wellbore Distributed Acoustic Sensing (DAS) data acquired during stimulation. Statistical analysis provided a quantitative assessment of SDE for the different completion designs. A novel workflow was developed to assess time-lapse fracture property changes at the cluster and stage levels based on Distributed Strain Sensing (DSS) data acquired during the production phase. These time-lapse fracture property changes were compared with the HF profile. Based on the statistical analysis, Rate Per Cluster (RPC) during proppant slurry placement appears to be a primary completion design variable, rather than the typical Rate Per Perf (RPP). If RPC was not maintained at a certain level, the likelihood of uneven distribution increased dramatically. The stage configurations that created low RPC while maintaining high RPP did not show improved SDE. The strain change results based on DSS data during the production phase indicated near-wellbore fracture property changes (e.g., aperture changes during well shut-in and flow periods) and aligned well with near-wellbore DAS signals acquired during stimulation. More importantly, fracture property changes based on DSS data acquired during two tests over a 7-month period show high consistency and good alignment with the near-wellbore HF profile. This workflow quantitatively evaluates SDE for different completion designs using diagnostic results and could help optimize completion strategy for future development projects. Here, the analysis and interpretation of results demonstrate the technical feasibility of using permanent fiber optic cable for stimulation and production monitoring and indic

58 GEOSCIENCES↗

Solid state d.c. power controller design philosophies and their evaluation.

Evaluation of remote power controllers (RPC), which has enhanced knowledge of the capabilities of various design philosophies and has indicated certain limitations that RPC's exhibit. Additionally, this activity has clearly emphasized that certain RPC design parameters merit further consideration in development. The major design parameters to be analyzed in more detail are the rates of change of the rise and fall times of the output current. The major reason why transient voltages and currents should be reduced is the minimization of the reverse collector-to-emitter voltage. The requirement for higher bus voltage coupled with the present problem of improving the efficiency of power control points out the urgent need for improvement and advancement of higher current, voltage, and gain power semiconductors.

Maus, L. G.↗

The solid state remote power controller: Its status, use and perspective

Solid state remote power controllers (RPC's) are now available to control and protect all types of loads in both ac and dc power distribution systems. RPC's possess many outstanding qualities that make them attractive for most system applications. A review is given of the present state-of-the-art and applications for solid state RPC's for both aerospace and terrestrial systems.

Sundberg, G. R.↗

Size-distributions of chondrule types in the Inman and Allan Hills A77011 L3 chondrites

The size distributions of barred-olivine (BO) and radial-pyroxene/cryptocrystalline (RPC) chondrules are investigated in a petrographic study of nine and 18 thin sections (respectively) of the L3 chondrites Inman and ALHA77011. It is found that the Inman chondrules are significantly larger than the ALHA77011 chondrules and that RPC chondrules in Inman and BO chondrules in ALHA77011 are relatively more numerous, but no significant difference in the BO and RPC size distributions is observed. A formation mechanism involving size sorting of dustball chondrule precursors by aerodynamic particle-gas interactions in a large region of the solar nebula, melting of sorted dustballs in relatively small regions, and chondrule mixing and agglomeration (from subreservoirs containing uniformly large or uniformly small chondrules of a particular compositional type) to form chondrites is proposed.

Rubin, A. E.↗

Retrievable payload carrier: Next generation Long Duration Exposure Facility

This paper describes the Retrievable Payload Carrier (RPC), which is a multi-experiment, free flyer spacecraft being privately developed to make in-space experimentation more accessible and economically feasible for research and development organizations. The carrier concept was derived from NASA's highly successful and flight proven Long Duration Exposure Facility (LDEF). The LDEF capabilities have been enhanced to meet new customer requirements. This reusable payload carrier is planned for launch and retrieval by the space shuttle on a regular basis. The RPC's flexible design will facilitate manifesting of the shuttle cargo bay space. The vehicle is designed so that either the entire vehicle or only individual experiments can be removed and replaced. A fully operational RPC program consists of: (1) a carrier spacecraft; (2) a ground control station; (3) a ground processing facility; and (4) the personnel required to support both the development and operational phases of the program.

Perry, Arthur T.↗

Potential of VIIRS Time Series Data for Aiding the USDA Forest Service Early Warning System for Forest Health Threats: A Gypsy Moth Defoliation Case Study

The Healthy Forest Restoration Act of 2003 mandated that a national forest threat Early Warning System (EWS) be developed. The USFS (USDA Forest Service) is currently building this EWS. NASA is helping the USFS to integrate remotely sensed data into the EWS, including MODIS data for monitoring forest disturbance at broad regional scales. This RPC experiment assesses the potential of VIIRS (Visible/Infrared Imager/Radiometer Suite) and MODIS (Moderate Resolution Imaging Spectroradiometer) data for contribution to the EWS. In doing so, the RPC project employed multitemporal simulated VIIRS and MODIS data for detecting and monitoring forest defoliation from the non-native Eurasian gypsy moth (Lymantria despar). Gypsy moth is an invasive species threatening eastern U.S. hardwood forests. It is one of eight major forest insect threats listed in the Healthy Forest Restoration Act of 2003. This RPC experiment is relevant to several nationally important mapping applications, including carbon management, ecological forecasting, coastal management, and disaster management

Spruce, Joseph P.↗

The multigap resistive plate chamber

The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

Zeballos, E. Cerron↗

Algorithms Used in Heterogeneous Dose Calculations Show Systematic Differences as Measured With the Radiological Physics Center's Anthropomorphic Thorax Phantom Used for RTOG Credentialing

Purpose: To determine the impact of treatment planning algorithm on the accuracy of heterogeneous dose calculations in the Radiological Physics Center (RPC) thorax phantom. Methods and Materials: We retrospectively analyzed the results of 304 irradiations of the RPC thorax phantom at 221 different institutions as part of credentialing for Radiation Therapy Oncology Group clinical trials; the irradiations were all done using 6-MV beams. Treatment plans included those for intensity-modulated radiation therapy (IMRT) as well as 3-dimensional conformal therapy (3D-CRT). Heterogeneous plans were developed using Monte Carlo (MC), convolution/superposition (CS), and the anisotropic analytic algorithm (AAA), as well as pencil beam (PB) algorithms. For each plan and delivery, the absolute dose measured in the center of a lung target was compared to the calculated dose, as was the planar dose in 3 orthogonal planes. The difference between measured and calculated dose was examined as a function of planning algorithm as well as use of IMRT. Results: PB algorithms overestimated the dose delivered to the center of the target by 4.9% on average. Surprisingly, CS algorithms and AAA also showed a systematic overestimation of the dose to the center of the target, by 3.7% on average. In contrast, the MC algorithm dose calculations agreed with measurement within 0.6% on average. There was no difference observed between IMRT and 3D CRT calculation accuracy. Conclusion: Unexpectedly, advanced treatment planning systems (those using CS and AAA algorithms) overestimated the dose that was delivered to the lung target. This issue requires attention in terms of heterogeneity calculations and potentially in terms of clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator

In the case of photovoltaic (PV) systems acting as distributed generation (DG) systems, the DC energy that is produced is fed to the grid through the power-conditioning unit (inverter). The majority of contemporary inverters used in DG systems are current source inverters (CSI) operating at unity power factor. If, however, we assume that voltage source inverters (VSI) can replace CSIs, we can generate reactive power proportionally to the remaining unused capacity at any given time. According to the theory of instantaneous power, the inverter reactive power can be regulated by changing the amplitude of its output voltage. In addition, the inverter active power can be adjusted by modifying the phase angle of its output voltage. Based on such theory, both the active power supply and the reactive power compensation (RPC) can be carried out simultaneously. When the insolation is weak or the PV modules are inoperative at night, the RPC feature of a PV system can still be used to improve the inverter utilisation factor. Some MATLAB simulation results are included here to show the feasibility of the method. (author)

14 SOLAR ENERGY↗

Novel rotating field probe for inspection of tubes

Inspection of steam generator tubes in nuclear power plants is extremely critical for safe operation of the power plant. In the nuclear industry, steam generator tube inspection using eddy current techniques has evolved over the years from a single bobbin coil, to rotating probe coil (RPC) and array probe, in an attempt to improve the speed and reliability of inspection. The RPC probe offers the accurate spatial resolution but involves complex mechanical rotation. This paper presents a novel design of eddy current probes based on rotating fields produced by three identical coils excited by a balanced three-phase supply. The sensor thereby achieves rotating probe functionality by electronic means and eliminates the need for mechanical rotation. The field generated by the probe is largely radial that result in induced currents that flow circularly around the radial axis and rotating around the tube at a synchronous speed effectively producing induced eddy currents that are multidirectional. The probe will consequently be sensitive to cracks of all orientations in the tube wall. The finite element model (FEM) results of the rotating fields and induced currents are presented. A prototype probe is being built to validate simulation results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

It’s a catfish! Novel approaches are needed to study the effects of rapid decompression on benthic species

Barotrauma due to rapid decompression has been recorded as the most common injury among fish captured in the tailrace of hydropower dams in Brazil, with catfishes representing the majority of them. Nevertheless, studies investigating barotrauma on catfish are scarce, with the majority determining dose-response curves and thresholds of pressure changes for nektonic species as salmonids. Experiments conducted with Pimelodus pictus showed that the current hypo-hyperbaric chambers used to study barotrauma in nektonic species have limitations when applied to benthic groups. The negative buoyancy showed by the catfish prevent the definition of the acclimation pressure of the fish prior to exposure to decompression and, therefore, hinder calculation of the ratio of pressure change (RPC). RPC has been considered the main factor explaining the likelihood of barotrauma on fish. Since its calculation is restricted for benthic species, new approaches deemed to be needed to complement barotrauma studies with this group. We aimed to discuss the limitations observed for studies with benthonic species and present potential methods to overcome them. The diversification of approaches for barotrauma studies with benthonic species is critical to provide information for the development of mitigation and new turbine designs that would improve protection of this group.

Do Vale Beirao, Bernardo↗

UPC++: A High-Performance Communication Framework for Asynchronous Computation

© 2019 IEEE UPC++ is a C++ library that supports high-performance computation via an asynchronous communication framework. This paper describes a new incarnation that differs substantially from its predecessor, and we discuss the reasons for our design decisions. We present new design features, including future-based asynchrony management, distributed objects, and generalized Remote Procedure Call (RPC). We show microbenchmark performance results demonstrating that one-sided Remote Memory Access (RMA) in UPC++ is competitive with MPI-3 RMA; on a Cray XC40 UPC++ delivers up to a 25% improvement in the latency of blocking RMA put, and up to a 33% bandwidth improvement in an RMA throughput test. We showcase the benefits of UPC++ with irregular applications through a pair of application motifs, a distributed hash table and a sparse solver component. Our distributed hash table in UPC++ delivers near-linear weak scaling up to 34816 cores of a Cray XC40. Our UPC++ implementation of the sparse solver component shows robust strong scaling up to 2048 cores, where it outperforms variants communicating using MPI by up to 3.1x. UPC++ encourages the use of aggressive asynchrony in low-overhead RMA and RPC, improving programmer productivity and delivering high performance in irregular applications.

Bachan, John↗

SYMBIOSYS: A Methodology for Performance Analysis of Composable HPC Data Services

Microservices are a powerful new way of building, customizing, and deploying distributed services owing to their flexibility and maintainability. Several large-scale distributed platforms have emerged to serve the growing needs of data-centric workloads and services in commercial computing. Concurrently, high-performance computing (HPC) systems and software are rapidly evolving to meet the demands of diversified applications and heterogeneity. The interplay of hardware factors, software configuration parameters, and the flexibility offered with a microservice architecture makes it nontrivial to estimate the optimal service instantiation for a given application workload. Further, this problem is exacerbated when considering that these services operate in a dynamic and heterogeneous HPC environment. An optimally integrated service can be vastly more performant than a haphazardly integrated one. Existing performance tools for HPC either fail to understand the request-response model of communication inherent to microservices or they operate within a narrow scope, limiting the insight that can be gleaned from employing them in isolation. We propose a methodology for integrated performance analysis of HPC microservices frameworks and applications called SYMBIOSYS. We describe its design and implementation within the context of the Mochi framework. This integration is achieved by combining distributed callpath profiling and tracing with a performance data exchange strategy that collects fine-grained, low-level metrics from the RPC communication library and network layers. The result is a portable, low-overhead performance analysis setup that provides a holistic profile of the dependencies among microservices and how they interact with the Mochi RPC software stack. Using HEPnOS, a production-quality Mochi data service, we demonstrate the low-overhead operation of SYMBIOSYS at scale and use it to identify the root causes of poorly performing service configurations.

microservices↗

Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom

Purpose: To calibrate a Gamma Knife (GK) Perfexion using TG-21 with updated chamber-dependent values for modern microionization chambers in the new solid water Leksell dosimetry phantom. This work illustrates a calibration method using commercially available equipment, instruments, and an established dosimetry protocol that may be adopted at any GK center, thus reducing the interinstitutional variation in GK calibration. The calibration was verified by three third-party dosimetry checks. In addition, measurements of the relative output factors are presented and compared to available data and the new manufacturer-provided relative output factors yet to be released. Methods: An absolute dose calibration based on the TG-21 formalism, utilizing recently reported phantom material and chamber-dependent factors, was performed using a microionization chamber in a spherical solid water phantom. The result was compared to other calibration protocols based on TG-51. Independent verification of the machine output was conducted through M.D. Anderson Dosimetry Services (MDADS), using thermoluminescent dosimeters (TLDs) in an anthropomorphic head phantom; the Radiological Physics Center (RPC), using TLDs in the standard Elekta ABS plastic calibration phantom (gray phantom), included with the GK; and through a collaborative international calibration survey by the University of Pittsburgh Medical Center (UPMC) using alanine dosimeters, also in the gray phantom. The alanine dosimeters were read by the National Institute of Standards and Technology. Finally, Gafchromic EBT film was used to measure relative output factors and these factors were compared to values reported in the literature as well as new values announced for release by Elekta. The films were exposed in the solid water phantom using an included film insert accessory. Results: Compared to the TG-21 protocol in the solid water phantom, the modified and unmodified TG-51 calibrations resulted in dose rates which were 1.8% and 1.3% lower, respectively. Ratios of the doses measured by third parties to the dose reported showed excellent agreement. MDADS returned ratios of 1.00 and 0.98 for the two TLDs irradiated. The RPC returned a mean ratio of 0.98 of the dose reported and the UPMC alanine study returned a mean ratio of 1.008. Relative output factors were found to be 0.817{+-}0.009 and 0.897{+-}0.008 for the 4 and 8 mm collimators, respectively, which are in excellent agreement with revised Monte Carlo-derived relative output factors Elekta is expected to recommend with the next version of the GK treatment planning software (GAMMAPLAN version 10). Conclusions: The TG-21 dosimetry protocol, performed in a solid water phantom in conjunction with modern dosimeters and phantom material and chamber-dependent factors, can yield an accurate dose measurement in the unique GK treatment geometry. The technique described here can be easily adopted by institutions worldwide since all equipment and instruments used are commercially available, thus reducing the existing interinstitutional variation in GK calibration techniques. Relative output factor measurements made in this same solid water phantom were used to verify the relative output factors provided by Elekta and agreed excellently with output factors expected to be released in conjunction with GAMMAPLAN version 10.

60 APPLIED LIFE SCIENCES↗

Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer

Purpose: The novel deterministic radiation transport algorithm, Acuros XB (AXB), has shown great potential for accurate heterogeneous dose calculation. However, the clinical impact between AXB and other currently used algorithms still needs to be elucidated for translation between these algorithms. The purpose of this study was to investigate the impact of AXB for heterogeneous dose calculation in lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Methods: The thorax phantom from the Radiological Physics Center (RPC) was used for this study. IMRT and VMAT plans were created for the phantom in the Eclipse 11.0 treatment planning system. Each plan was delivered to the phantom three times using a Varian Clinac iX linear accelerator to ensure reproducibility. Thermoluminescent dosimeters (TLDs) and Gafchromic EBT2 film were placed inside the phantom to measure delivered doses. The measurements were compared with dose calculations from AXB 11.0.21 and the anisotropic analytical algorithm (AAA) 11.0.21. Two dose reporting modes of AXB, dose-to-medium in medium (D{sub m,m}) and dose-to-water in medium (D{sub w,m}), were studied. Point doses, dose profiles, and gamma analysis were used to quantify the agreement between measurements and calculations from both AXB and AAA. The computation times for AAA and AXB were also evaluated. Results: For the RPC lung phantom, AAA and AXB dose predictions were found in good agreement to TLD and film measurements for both IMRT and VMAT plans. TLD dose predictions were within 0.4%-4.4% to AXB doses (both D{sub m,m} and D{sub w,m}); and within 2.5%-6.4% to AAA doses, respectively. For the film comparisons, the gamma indexes ({+-}3%/3 mm criteria) were 94%, 97%, and 98% for AAA, AXB{sub Dm,m}, and AXB{sub Dw,m}, respectively. The differences between AXB and AAA in dose-volume histogram mean doses were within 2% in the planning target volume, lung, heart, and within 5% in the spinal cord. However, differences up to 8% between AXB and AAA were found at lung/soft tissue interface regions for individual IMRT fields. AAA was found to be 5-6 times faster than AXB for IMRT, while AXB was 4-5 times faster than AAA for VMAT plan. Conclusions: AXB is satisfactorily accurate for the dose calculation in lung cancer for both IMRT and VMAT plans. The differences between AXB and AAA are generally small except in heterogeneous interface regions. AXB D{sub w,m} and D{sub m,m} calculations are similar inside the soft tissue and lung regions. AXB can benefit lung VMAT plans by both improving accuracy and reducing computation time.

60 APPLIED LIFE SCIENCES↗

SU-F-T-606: Monte Carlo Evaluation of Tissue Inhomogeneity Corrections in the Treatment of Liver Cancer Patients Using Stereotactic Body Radiotherapy

Purpose: To evaluate the dosimetric performance of X-ray Voxel Monte Carlo(XVMC) algorithm in effort to clinically validate Monte Carlo-approach in heterogeneous liver phantom and liver SBRT plans. Methods: An anthropomorphic RPC liver phantom incorporating a liver structure with two cylindrical targets and organs-at-risk (OARs) was used in phantom validation. Subsequently, five patients with metastatic liver cancer were treated using heterogeneity-corrected pencil-beam(PB-hete)algorithm were analyzed following RTOG-1112 criteria .ITV was delineated on MinIP and OARs were contoured on MeanIP images of 4D-CT. PTV was generated from ITV with 5-10mm uniform margin. Mean PTV was 81.3±46.4cc. Prescription was 30–45Gy in 5 fractions, with at least PTV(D95%)=100%. Hybrid SBRT plans were generated with noncoplanar/3D-conformal arcs plus static-beams at Novalis-TX consisting of HD-MLC and 6MV-SRS. SBRT plans were re-computed using XVMC algorithm utilizing identical beam-geometry, MLC-positions, and monitor units and subsequently compared to clinical PB-hete plans. Results: Our results using RPC liver motion phantom validation were all compliance with MD Anderson standards. However, compared to PB-hete, average target volume encompassed by the prescribed percent isodose (Vp) was 9.1% and 8.5% less for PTV1 and PTV2 with XVMC. For the clinical liver SBRT plans, PB-hete systematically overestimated PTV dose (D95, Dmean and D10) within ±2.0% (p<0.05) compared to XVMC. Mean value of Vp was about 3.8% less with XVMC compared to PB-hete (ranged 2.9–5.7% (p<0.003)). However, mean liver dose (MLD) was 3.2% higher (p<0.003), on average, with XVMC compared to clinical PB-hete (ranged −1.0to−3.9%). OARs doses were statistically insignificant. Conclusion: Results from our XVMC dose calculations and validation study for liver SBRT indicate small-to-moderate under-dosing of the tumor volume when compared to PB-hete. Results were consistent with phantom validation and patients plans. However, Vp was less by up to 5.7% for some liver SBRT patients with XVMC–suggesting under-dosing of the target volume and overdosing of MLD by up to 3.9% occurred with PB-hete plan. These differences between PB-hete and XVMC dose calculations may be of clinical interest.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗