Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Hardness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Annual LDRD Report (FY2019)

The performance of Nuclear Deterrence (ND) systems could be improved by adopting advanced commercial CMOS technologies. However, the radiation hardness of these ND systems must be assured. This project quantified dose rate upset thresholds, allowing us to evaluate whether advanced commercial technologies can be used in rad hard applications. This project also evaluated the susceptibility of advanced commercial technologies to neutron displacement damage and single event effects, and developed hardness assurance methods. As a result of this work, Sandia is now collaborating more closely with DoD agencies and their contractors to understand and improve the radiation hardness of advanced commercial technologies. Sandia Capabilities (SPHINX, lon Beam Lab, FPGA test capabilities) were developed and are being utilized by other programs. Staff were trained to do radiation survivability testing and developed proposals that were funded. Internal and external collaborations and partnerships were developed, including with Georgia Tech. This project received the Best Paper award at the 2019 Hardened Electronics And Radiation Technology (HEART) Conference.

36 MATERIALS SCIENCE↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Resilience of High-Efficiency CdSeTe:As and CdSeTe:Cu Solar Cells to Proton Irradiation

Power generation in space is currently dominated by expensive III-V multi-junction photovoltaic (PV) devices and cheap crystalline silicon (c-Si) PV devices. Both of these technologies degrade rapidly in proton-radiation-rich space environments, such as the Van Allen belt. The present study of cadmium selenide telluride- (CdSeTe-) based PV devices exposed to 150-to-1500 keV proton irradiation with fluences up to 9 x 1013 cm-2 reveal a more radiation-hard alternative to III-V and c-Si PV technologies. We report on measurement and analysis of current density vs voltage (JV), external quantum efficiency (EQE), external radiative efficiency, and capacitance vs voltage (CV) characteristics. JV characteristics of As-doped CdSeTe devices show 80% remaining power conversion efficiency (PCE) relative to unexposed controls when exposed to 650 keV protons at a fluence of 1012 cm-2. Under these same irradiation conditions, Cu-doped CdSeTe devices demonstrate an even better 95% PCE retention compared with unirradiated control devices. Evidence of radiation-induced absorber p-type doping compensation is observed in the glass-side EQE at 0 V and CV characteristics of most of the irradiated CdSeTe:As devices, but clear compensation is evident only for the most heavily irradiated CdSeTe:Cu devices. Elevated blue-green photocurrent in the film-side 0 V EQE suggests a buried junction in the most heavily irradiated CdSeTe:As devices. Although CdSeTe:Cu devices are the more resilient of the CdSeTe structures, both CdSeTe-based technologies are radiation-hard when compared to c-Si and III-V multi-junction PV.

14 SOLAR ENERGY↗

Exploring Functional Materials by Understanding Beam‐Sample Interactions

Abstract Ultra‐low‐dose electron diffraction is performed with a double metal cyanide catalyst (DMC) to understand how electron irradiation stimulates structural alterations in functional materials. The commonly fading diffraction patterns with dose accumulation depend on the irradiated area and the beam current even when below 50 femto Amperes. Heat generation is observed and modeled by statistical, inelastic scattering events to describe how phonon excitations modulate radiation hardness. Specifically, the characteristic 1/e‐decay of Bragg intensities from DMC is delayed from 6 to 30 eÅ −2 at room temperature, which is comparable to the effect of embedding radiation soft matter in ice. DMC's radiation hardness is enhanced by a latency dose that forms during a phase transformation. This unifying model predicts that a critical dose rate exists for any material that varies between 0.1 and 10 4 eÅ −2 s −1 because of a material dependent competition of heat generation and spread. It shows that Brillouin scattering causes time dependent perturbations in electron irradiated solids that trigger time‐temperature‐transformations on a time scale of nanoseconds to microseconds at room temperature, which is not included in traditional models describing the decay of Bragg intensities by radiolysis.

Kisielowski, Christian↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Assessing the sources of reionization: a spectroscopic case study of a 30× lensed galaxy at z ~ 5 with Ly α , C IV, Mg ιι, and [Ne ιιι]

We present a detailed spectroscopic analysis of a galaxy at z ≃ 4.88 that is, by chance, magnified ~30× by gravitational lensing. Only three sources at z ≳ 5 are known with such high magnification. This particular source has been shown to exhibit widespread, high equivalent width ${{\rm C\, \small {IV}}}\ \lambda 1549\, \mathring{\rm A}$ emission, implying it is a unique example of a metal-poor galaxy with a hard radiation field, likely representing the galaxy population responsible for cosmic reionization. Using ultraviolet (UV) nebular line ratio diagnostics, Very Large Telescope (VLT)/X-shooter observations rule out strong active galactic nuclei (AGN) activity, indicating a stellar origin of the hard radiation field instead. We present a new detection of ${[{\rm Ne\, \small {III}}]}\ \lambda 3870\, \mathring{\rm A}$ and use the [${\rm Ne\, \small {III}}$]/[${\rm O\, \small {II}}$] line ratio to constrain the ionization parameter and gas-phase metallicity. Closely related to the commonly used [${\rm O\, \small {III}}$]/[${\rm O\, \small {II}}$] ratio, our [${\rm Ne\, \small {III}}$]/[${\rm O\, \small {II}}$] measurement shows this source is similar to local ‘Green Pea’ galaxies and Lyman-continuum leakers. It furthermore suggests this galaxy is more metal poor than expected from the fundamental metallicity relation, possibly as a consequence of excess gas accretion diluting the metallicity. Finally, we present the highest redshift detection of ${{\rm Mg\, \small {II}}}\ \lambda 2796\, \mathring{\rm A}$, observed at high equivalent width in emission, in contrast to more evolved systems predominantly exhibiting ${\rm Mg\, \small {II}}$ absorption. Strong ${\rm Mg\, \small {II}}$ emission has been observed in most z ~ 0 Lyman-continuum leakers known and has recently been proposed as an indirect tracer of escaping ionizing radiation. In conclusion, this strongly lensed galaxy, observed just $300\, \mathrm{Myr}$ after reionization ends, enables testing of observational diagnostics proposed to constrain the physical properties of distant galaxies in the James Webb Space Telescope (JWST)/Extremely Large Telescope (ELT) era.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Before and After Irradiation of Pixelated 3D Silicon Sensors for the HL-LHC CMS Tracker

The Large Hadron Collider (LHC) particle accelerator at European Center for Nuclear Research (CERN) will be shut down starting in 2026 to achieve the High Luminosity Large Hadron Collider (HL-LHC) upgrade. The upgrade will allow for higher fluences, in order to increase the probability of detecting increasingly rare particles, and to obtain higher precision measurements of known particles. To accommodate the new accelerator conditions, many aspects of the Compact Muon Solenoid (CMS) detector will be upgraded; of particular interest for this thesis are the silicon pixel detectors located in the inner tracker. These will be replaced and upgraded to accommodate the higher fluences of the HL-LHC upgrade, as well as to replace existing sensors which have sustained radiation damage. In order for the new sensors to operate under high luminosity conditions, they must be increasingly radiation hard, and in order to detect rare particles, they must be increasingly more precise. The performance of one Centro Nacional de Microelectronica (CNM) 3D silicon sensor before and after undergoing irradiation at fluences similar to those which will be observed at the HL-LHC was investigated to determine radiation hardness and precision. Data was collected at Fermi National Laboratory (Fermilab), in the Fermi National Laboratory Test Beam Facility (FTBF) silicon tracker telescope, which can be used to determine the number of particles, and tracks made by high energy protons passing through. The sensor was also irradiated at Fermilab in the Irradiation Test Area (ITA). Prior to data collection a tuning procedure is carried out to determine ideal bias voltage operating conditions, mask noisy and dead pixels, adjust to the ideal threshold, and map sensor gain. Data is then collected at the FTBF, where the sensor is installed in the center of the FTBF silicon telescope. Variables, including angle and bias voltage, are varied throughout data collection. Data is then processed using an alignment software to determine the exact telescope geometry, along with the tracks which were observed passing through the sensor and telescope. Sensor performance was found to be comparable before and after irradiation, with irradiated results showing slightly lower efficiencies and cluster sizes. Position resolution is comparable both before and after irradiation, and similar distributions of cluster shape are observed. After irradiation, the sensor shows increasing collected charge with bias, an indication of increased width of the depletion region. Peak charge pre-irradiation is higher than post-irradiation peak charge, indicating the irradiated results are not taken under fully-depleted conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

MEMS RF accelerators for nuclear energy and advanced manufacturing

Energetic ions are widely used to develop radiation hard structural materials and fuels for advanced nuclear energy. Ion beams are also used to generate neutrons for nuclear materials testing, as well as in a series of high impact, high value adding manufacturing processes (ranging from doping of semiconductors to hardening of materials against wear and to increase bio-compatibility of materials). But to date, high power beams of high energy ions are simply too expensive because they are delivered from large single beam accelerators. We have recently demonstrated that MEMS technology enables massively parallel, low cost batch fabrication of ion beams. We propose to scale intense ion accelerators based on MEMS (micro-electro mechanical systems) to high beam power (>10 kW). With our approach, hundreds to thousands of ion beamlets will be densely packed on silicon wafers. Ions are injected and accelerated across gaps formed in stacks of wafers, leading to uniquely high current densities for intense ion accelerators with variable kinetic energy (0.1 to 10 MeV) and variable ion species. Our team brings together experts in high power ion accelerators from Lawrence Berkeley National Laboratory and leading experts in MEMS technology from Cornell University. We will deliver a disruptive technology of low cost, flexible and massively scalable ion accelerators that will enable the rapid development of radiation hard nuclear materials for advanced nuclear energy and enable new applications in manufacturing.

43 PARTICLE ACCELERATORS↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hardened Engineered Substrates for Time and Space Resolution

Low Gain Avalanche Diodes (LGADs) have become sensors of choice for fast timing of minimum ionizing particles. The current generation of these devices suffer from only moderate radiation hardness, low fill factor, and limited design options. Cactus Materials Inc. proposes to develop sensors with gain layer implants buried beneath the surface which will, with AC coupling developed by Brookhaven National Laboratory (BNL) and University of California Santa Cruz (UC Santa Cruz) solve these problems. Fermilab has a major role in the CMS timing upgrade using the current generation of LGADs and development of AC-coupled, buried layer LGADs will solve some of the central problems inherent in this technology. Annex B included a two-year work plan, deliverables, schedule and funding for the project’s SBIR Phase II award to develop and test prototype LGADs utilizing wafer bonding technology and epitaxial growth, that will allow for fabrication of radiation hard AC coupled devices with 100% fill factor and adjustable operating point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HARD: A performance portable radiation hydrodynamics code based on FleCSI framework

Hydrodynamics And Radiation Diffusion (HARD) is an open-source application for high-performance simulations of compressible hydrodynamics with radiation-diffusion coupling. Built on the FleCSI (Bergen et al., 2021 [1]) (Flexible Computational Science Infrastructure) framework, HARD expresses its computational units as tasks whose execution can be orchestrated by multiple back-end runtimes, including Legion (Bauer et al., 2012 [2]), MPI (Forum, 1994 [3]), and HPX (Kaiser et al., 2020 [4]). Node-level parallelism is handled through Kokkos (Edwards et al., 2014 [5]), providing a single-source, portable code base that runs efficiently on laptops, small homogeneous clusters, and the largest heterogeneous supercomputers currently available. To ensure scientific reliability, HARD includes a regression test suite that automatically reproduces canonical verification problems such as the Sod and LeBlanc shock tubes, and the Sedov blast wave, comparing numerical solutions against known analytical results. The project is distributed under an OSI-approved license, hosted on GitHub, and accompanied by reproducible build scripts and continuous integration workflows. This combination of performance portability, verification infrastructure, and community-focused development makes HARD a sustainable platform for advancing radiation hydrodynamics research across multiple domains.

97 MATHEMATICS AND COMPUTING↗

UV–Visible reflectance of common light reflectors and their degradation after an ionization dose up to 100 Mrad

We report light reflectors are widely used to enhance scintillation light collection. Their enhancement level depends on the reflector’s reflectance at the scintillator’s emission wavelength. We report UV–Visible reflectance spectra, relative to BaSO 4 , for several common reflectors. Also reported is their radiation hardness against an ionization dose up to 100 Mrad. The results of this investigation provide a reference for applications of these reflectors in a severe radiation environment.