Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation biosensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Biosentinel: Mission Summary and Lessons Learned From the First Deep Space Biology CubeSat Mission

Launched on Artemis-1, BioSentinel carries a biology experiment into deep space for the first time in 50 years. A 6U CubeSat form factor was utilized for the spacecraft which included technologies newly developed or adapted for operations beyond Earth orbit. The spacecraft carries onboard budding yeast, Saccharomyces cerevisiae, as an analog to human cells to test the biological response to deep space radiation. This was the maiden deep-space voyage for many of the subsystems, and the first time to evaluate their performance in flight operation. Flying a CubeSat beyond LEO comes with unique challenges with respect to trajectory uncertainty and mission operations planning. The nominal plan was a lunar fly-by, followed by an insertion into Heliocentric orbit. However, some possible scenarios included lunar eclipses that could have severely impacted the power budget during that phase of the mission, while others could have resulted in a “Retrograde” hyperbola at swing-by resulting in the spacecraft traveling inward toward Earth or even towards a collision with the lunar surface. The commissioning phase of the mission was successful and completed a week ahead of schedule. It did not come without its exciting moments and challenges. First contact with the spacecraft uncovered that the vehicle was unexpectedly tumbling after deployment, a situation that needed to be corrected urgently. The mission operations team executed a contingency plan to stabilize the spacecraft, with just moments to spare before the battery ran out of power. The BioSensor payload onboard the spacecraft is a complex instrument that includes microfluidics, fluid systems, sensor control electronics, as well at the living yeast cells. BioSentinel also included a TimePix radiation sensor implemented by JSC’s RadWorks group. Dose and Linear Energy Transfer (LET) data is compared directly to the rate of DSB-and repair events measured by the S. cerevisiae cells. BioSentinel mature nanosatellite technologies included: deep space communications and navigation, autonomous attitude control and momentum management, and micro-propulsion systems, to provide an adaptable nanosatellite platform for deep space uses. This paper discusses the performance of the BioSentinel spacecraft through the mission phase, and includes lessons learned from challenges and anomalies. BioSentinel had many successes and will be a pathfinder for future deep space CubeSats and biology missions.

BioSentinel↗

Biosentinel: The First Deep Space Biology CubeSat Mission- Mission Summary and Lessons Learned

Launched on Artemis-1, BioSentinel carries a biology experiment into deep space for the first time in 50 years. A 6U CubeSat form factor was utilized for the spacecraft which included technologies newly developed or adapted for operations beyond Earth orbit. The spacecraft carries onboard budding yeast, Saccharomyces cerevisiae, as an analog to human cells to test the biological response to deep space radiation. This was the maiden deep-space voyage for many of the subsystems, and the first time to evaluate their performance in flight operation. Flying a CubeSat beyond LEO comes with unique challenges with respect to trajectory uncertainty and mission operations planning. The nominal plan was a lunar fly-by, followed by an insertion into Heliocentric orbit. However, some possible scenarios included lunar eclipses that could have severely impacted the power budget during that phase of the mission, while others could have resulted in a “Retrograde” hyperbola at swing-by resulting in the spacecraft traveling inward toward Earth or even towards a collision with the lunar surface. The commissioning phase of the mission was successful and completed a week ahead of schedule. It did not come without its exciting moments and challenges. First contact with the spacecraft uncovered that the vehicle was unexpectedly tumbling after deployment, a situation that needed to be corrected urgently. The mission operations team executed a contingency plan to stabilize the spacecraft, with just moments to spare before the battery ran out of power. The BioSensor payload onboard the spacecraft is a complex instrument that includes microfluidics, fluid systems, sensor control electronics, as well at the living yeast cells. BioSentinel also included a TimePix radiation sensor implemented by JSC’s RadWorks group. Dose and Linear Energy Transfer (LET) data is compared directly to the rate of DSB-and repair events measured by the S. cerevisiae cells. BioSentinel mature nanosatellite technologies included: deep space communications and navigation, autonomous attitude control and momentum management, and micro-propulsion systems, to provide an adaptable nanosatellite platform for deep space uses. This paper discusses the performance of the BioSentinel spacecraft through the mission phase, and includes lessons learned from challenges and anomalies. BioSentinel had many successes and will be a pathfinder for future deep space CubeSats and biology missions.

BioSentinel↗

Advanced performance and scalability of Si nanowire field-effect transistors analyzed using noise spectroscopy and gamma radiation techniques

High-quality Si nanowire field effect transistors (FETs) were fabricated using thermal nanoimprint and chemical wet etching technologies. FET structures of different lengths demonstrate high carrier mobility with values of about 750 cm{sup 2}/Vs and low volume densities of active traps in the dielectric layers of 5 × 10{sup 17} cm{sup −3} eV{sup −1}. We investigated the transport properties of these n-type channel structures using low-frequency noise spectroscopy before and after gamma radiation treatment. Before gamma irradiation, FET structures with lengths of less than 4 μm exhibited noise from contact regions with 1/(L{sup 2}) dependence for the relative 1/f noise. After gamma radiation, the spectra reflected the priority of channel noise with 1/L dependence for all samples. The transport characteristics show that the fabricated nanowire FETs improved scalability, decreased parameter scattering, and increased stability after treatment. The results demonstrate that these nanowire FETs are promising for nanoelectronic and biosensor applications due to the cost-efficient technology and advanced performance of FETs with improved stability and reliability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Biosensors Based on Photonic Crystals Supporting Bound States in the Continuum

A novel optical label-free bio-sensing platform based on a new class of resonances supported in a photonic crystal metasurface is reported herein. Molecular binding is detected as a shift in the resonant wavelength of the bound states in the continuum of radiation modes. The new configuration is applied to the recognition of the interaction between protein p53 and its protein regulatory partner murine double minute 2 (MDM2). A detection limit of 66 nM for the protein p53 is found. The device provides an excellent interrogation stability and loss-free operation, requires minimal optical interrogation equipment and can be easily optimized to work in a wide wavelength range.

47 OTHER INSTRUMENTATION↗

Localized surface plasmon mediated energy transfer in the vicinity of core-shell nanoparticle

Multipole spectral expansion based theory of energy transfer interactions between a donor and an acceptor molecule in the vicinity of a core-shell (nanoshell or core@shell) based plasmonic nanostructure is developed. In view of the diverse applications and rich plasmonic features such as tuning capability of surface plasmon (SP) frequencies, greater sensitivity to the change of dielectric environment, controllable redirection of electromagnetic radiation, closed form expressions for Energy Transfer Rate Enhancement Factor (ETREF) near core-shell particle are reported. The dependence of ETREF on different parameters is established through fitting equations, perceived to be of key importance for developing appropriate designs. The theoretical approach developed in the present work is capable of treating higher order multipoles, which, in turn, are also shown to play a crucial role in the present context. Moreover, closed form expressions derived in the present work can directly be used as formula, e.g., for designing SP based biosensors and estimating energy exchange between proteins and excitonic interactions in quantum dots.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slow light enhanced bio sensing properties of silicon sensors

In this paper, we investigated slow light to increase sensitivity and quality factor of our recently designed bio-sensors. A finite difference time domain and Plane Wave Expansion methods are employed to figure out sensors’ performances. We proposed slow light based photonic crystal structures with elliptical cells and we obtained higher sensitivity and quality factor as previously reported. For the first proposed sensor, the results showed that quality factor increased from 570 to 723 and a detection limit below 10{sup −3}. For the second sensor, the sensitivity increased from 550 to 650 nm/RIU and the detection limit is around 10{sup −3}. These two proposed structures would offer great potential for novel compact biosensors in medical application.

36 MATERIALS SCIENCE↗

Detecting ionizing radiation using halide perovskite semiconductors processed through solution and alternative methods

We report the direct detection of high-energy radiation such as X-rays and.-rays by semiconductors at room temperature is a challenging proposition that requires remarkably pure and nearly perfect crystals. The emergence of metal halide perovskites, defect-tolerant semiconductors, is reviving hope for new materials in this field after an almost 20 year hiatus. Metal halide perovskites, which combine exceptional optoelectronic properties, versatile chemistry and simple synthesis, are challenging traditional approaches for the development of novel semiconductors for detecting hard radiation. We discuss the relevant physical properties, promising materials, fabrication techniques and device architectures for high-performance, low-cost detectors by targeting next-generation semiconductors for radiation detection. We also present a perspective on the impact of such advances in future medical imaging applications.

36 MATERIALS SCIENCE↗

Synthesis of TiO{sub 2} nanoparticles decorated with gold nanoclusters using pulsed laser ablation in liquid

Amorphous spherical titanium dioxide (TiO{sub 2}) nanoparticles, decorated gold nanoparticles, are shown to be formed under irradiation of commercial TiO{sub 2} nanopowders dispersed in aqueous solution of hydrogen tetrachloroaurate (HAuCl{sub 4}) by second-harmonic nanosecond pulses of an Nd : YAG laser. It is found that these hybrid nanostructures are formed during laser-induced remelting of the initial nanoparticles, stimulated by gold nanoclusters (providing more efficient absorption of visible laser radiation by titanium dioxide) recovered on their surface. The morphology and chemical composition of the newly formed hybrid nanomaterials are investigated in detail by electron microscopy, Raman spectroscopy, and energy-dispersive analysis. It is shown that the average size and number of gold nanoparticles recovered on the TiO{sub 2} surface can be controlled by varying the concentration ratio of the initial nanomaterial and HAuCl{sub 4}. A spectroscopic analysis of light scattering by single hybrid nanoparticles and the results of numerical calculation of the structure of electromagnetic fields near their surface indicate good prospects of these hybrid nanomaterials for various applications in modern optics, optoelectronics, and nanophotonics; for example, for designing chemo- and biosensor platforms and new-generation solar cells. (nanoparticles)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Amplification of interference color by using liquid crystal for protein detection

Micrometer-sized, periodic protein lines printed on a solid surface cause interference color which is invisible to the naked eye. However, the interference color can be amplified by using a thin layer of liquid crystal (LC) covered on the surface to form a phase diffraction grating. Strong interference color can thus be observed under ambient light. By using the LC-amplified interference color, we demonstrate naked-eye detection of a model protein—immunoglobulin G (IgG). Limit of detection can reach 20 μg/ml of IgG without using any instrumentation. This detection method is potentially useful for the development of low-cost and portable biosensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carbon Nanotube Based Nanotechnology for NASA Mission Needs and Societal Applications

Carbon nanotubes (CNT) exhibit extraordinary mechanical properties and unique electronic properties and therefore, have received much attention for more than a decade now for a variety of applications ranging from nanoelectronics, composites to meeting needs in energy, environmental and other sectors. In this talk, we focus on some near term potential of CNT applications for both NASA and other Agency/societal needs. The most promising and successful application to date is a nano chem sensor at TRL 6 that uses a 16-256 sensor array in the construction of an electronic nose. Pristine, doped, functionalized and metal-loaded SWCNTs are used as conducting materials to provide chemical variation across the individual elements of the sensor array. This miniaturized sensor has been incorporated in an iPhone for homeland security applications. Gases and vapors relevant to leak detection in crew vehicles, biomedical, mining, chemical threats, industrial spills and others have been demonstrated. SWCNTs also respond to radiation exposure via a change in conductivity and therefore, a similar strategy is being pursued to construct a radiation nose to identify radiation sources (gamma, protons, neutrons, X-ray, etc.) with their energy levels. Carbon nanofibers (CNFs) grown using plasma enhanced CVD typically are vertical, individual, freestanding structures and therefore, are ideal for construction of nanoelectrodes. A nanoelectrode array (NEA) can be the basis for an affinity-based biosensor to meet the needs in applications such as lab-on-a-chip, environmental monitoring, cancer diagnostics, biothreat monitoring, water and food safety and others. A couple of demonstrations including detection of e-coli and ricin will be discussed. The NEA is also useful for implantation in the brain for deep brain stimulation and neuroengineering applications. Miniaturization of payload such as science instrumentation and power sources is critical to reduce launch costs. High current density (greater than 100 mA/per square centimeters) field emission capabilities of CNTs can be exploited for construction of electron gun for electron microscopy and X-ray tubes for spectrometers and baggage screening. A CNT pillar array configuration has been demonstrated, not only meeting the high current density needs but more importantly providing long term emitter stability. Finally, supercapacitors hold the promise to combine the high energy density of a battery with the high power density of capacitors. Traditional graphite electrodes have not delivered this promise yet. A novel design and processing approach using MWCNTs has shown a record 550 F/g capacitance along with significant device endurance. This supercapacitor is suitable for railgun launch application for NASA, powering rovers and robots, consumer electronics and future hybrid vehicles.

Li, Jing↗

NASA SmallSat LEARN Forum Briefing: BioSentinel

We will focus on the technologies developed for BioSentinel, primarily the science payloads. One of them, the BioSensor, is a microfluidics-based instrument that houses a series of fluidic cards and manifolds. The fluidic cards can be loaded with microbial organisms to study the effect of the space environment on biology. For BioSentinel, we used the budding yeast as our model organism to study the response to the radiation environment in both low Earth orbit (ISS) and in deep space. The second instrument is a radiation spectrometer. This sensor allows the quantification of ionizing radiation as well as the characterization of the different particles based on the linear energy transfer or LET. Given that BioSentinel launched this past November (Artemis I), part of the presentation will include lessons learned and how we will apply them to future missions, including LEIA. LEIA was recently selected for a mission to the lunar surface on a CLPS lander vehicle, and is primarily based at NASA Ames.

BioSentinel↗

Glycerol capped PbS/CdS core/shell nanoparticles at different molar ratio and its application in biosensors: An optical properties study

Glycerol capped PbS/CdS core/shell type nanoparticles fabricated with two different molar ratios are characterized for study of structural and optical properties. The X-ray diffraction (XRD) pattern exhibits cubic phased polycrystalline nanocrystals. The calculated grain sizes from Williamson-Hall plot were found to be around 6 nm with increased strain. HRTEM investigation confirms the formation of core/shell nanostructures and the sizes of the particles were found to be around 7 nm which is in good agreement with the results of the W-H plot. An increase of band gap with the decrease in precursor concentration is confirmed from the blue shift in the absorption spectra and also from Tauc plot. A clear blue shifted intense emission is observed in the photoluminescence spectra with decrease in particle size. Intense luminescence from the core/shell nanostructure may be applied in bio labelling and biosensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spectroscopic investigations on oxidized multi-walled carbon nanotubes

The pristine multi-walled carbon nanotubes (MWCNTs) were oxidized by the ultrasonication process. The oxidized MWCNTs were characterized by the X-ray diffraction (XRD), ultraviolet–visible (UV-Vis) and Fourier transform -Raman (FT-Raman) spectroscopic techniques. The XRD analysis confirms that the oxidized MWCNTs exist in a hexagonal structure and the sharp XRD peak corresponds to the (002) Bragg’s reflection plane, which indicates that the MWCNTs have higher crystalline nature. The UV-Vis analysis confirms that the MWCNTs functionalized with the carboxylic acid. The red shift was observed corresponds to the D band in the Raman spectrum, which reveals that the reduced disordered graphitic structure of oxidized MWCNTs. The strong Raman peak was observed at 2563 cm{sup -1} corresponds to the overtone of the D band, which is the characteristic vibrational mode of oxidized MWCNTs. The carboxylic acid functionalization of MWCNTs enhances the dispersibility, which paves the way for potential applications in the field of biosensors and targeted drug delivery.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A new fluorescence-based method to monitor the pH in the thylakoid lumen using GFP variants

The ΔpH-dependent/Tat pathway is unique for using only the proton motive force for driving proteins transport across the thylakoid membrane in chloroplasts. 9-aminoacridine fluorescence quenching is widely used to monitor the ΔpH developed across the thylakoid membrane in the light. However, this method suffers from limited sensitivity to low ΔpH values and to spurious fluorescence signals due to membrane binding. In order to develop a more sensitive method for monitoring the real pH of the thylakoid lumen without these problems we transformed Arabidopsis thaliana with a ratiometric pH-sensitive GFP variant (termed pHluorin) targeted to the lumen by the prOE17 transit peptide. Positive transgenic plants displayed localization of pHluorin in the chloroplast by confocal microscopy, and fractionation experiments revealed that it is in the lumen. The pHluorin signal was the strongest in very young plants and diminished as the plants matured. The pHluorin released from the lumen displayed the expected fluorescence intensity changes in response to pH titration. The fluorescence signal in isolated chloroplasts responded to illumination in a manner consistent with light-dependent lumen acidification. Future experiments will exploit the use of this new pH-indicating probe of the thylakoid lumen to examine the influence of the thylakoid ΔpH on ATP synthesis and protein transport.

60 APPLIED LIFE SCIENCES↗

Evolution of Biological Satellites: From Low Earth Orbit to NASA’s BioSentinel Deep Space Mission

NASA has set its sights on human exploration in deep space with the Artemis missions, with an ambitious plan to put astronauts back on the Moon and to eventually land human missions on Mars. Such missions will require significant countermeasures, likely both technological and biomedical, to protect biology from chronic radiation exposure. Small satellites like CubeSats can inform these countermeasures by querying relevant space environments with model organisms over relevant durations. NASA has launched five biological CubeSats into low Earth orbit (LEO) from GeneSat in 2006 to EcAMSat in 2017. Each one of these missions increased our understanding of the effects of spaceflight, while refining technologies and imparting valuable lessons to the next generation of CubeSats. The Artemis I rocket will carry ten CubeSats, each of them with its own objective. One in particular, BioSentinel, will conduct the first study of the biological response to interplanetary space radiation beyond LEO since Apollo 17. Once it reaches its heliocentric orbit – after a short lunar fly-by – BioSentinel will measure the DNA damage response to ambient radiation in a model organism, the budding yeast Saccharomyces cerevisiae, which will be compared to information provided by an onboard radiation sensor and to data obtained in LEO (on ISS) and on Earth. Once in interplanetary space, fluidic cards containing desiccated yeast cells will be activated by growth medium addition at different time points throughout the mission. Growth and metabolic activity will be tracked continuously via optical density. BioSentinel is a complete, autonomous spacecraft capable of conducting experiments in deep space. Its 4U BioSensor payload is a fully automated and adaptable platform that can perform biological measurements with a range of microorganisms in multiple space environments, including the ISS, free flyers, and other platforms like the Lunar Gateway and lander vehicles.

Sergio R Santa Maria↗

Direct laser immobilization of photosynthetic material on screen printed electrodes for amperometric biosensor

This letter demonstrates the direct laser printing of photosynthetic material onto low cost nonfunctionalized screen printed electrodes for the fabrication of photosynthesis-based amperometric biosensors. The high kinetic energy of the transferred material induces direct immobilization of the thylakoids onto the electrodes without the use of linkers. This type of immobilization is able to establish efficient electrochemical contact between proteins and electrode, stabilizing the photosynthetic biomolecule and transporting electrons to the solid state device with high efficiency. The functionality of the laser printed biosensors was evaluated by the detection of a common herbicide such as Linuron.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beyond BioSentinel: Iterative Development of Automated Microfluidics

NASA Ames has flown a series of Bio-CubeSats that performed biology experiments supported by automated fluidic systems. Since Genesat-1 in 2006, these payloads have increased in complexity and functionality, building upon previous successes, and applying lessons learned. BioSentinel was the most recent of this series, launched into heliocentric orbit onboard Artemis-1 in 2022. This presentation will discuss how the fluidic technology developed for these Bio-CubeSat missions, including the multi-layer polycarbonate manifolds at the heart of the BioSentinel BioSensor, have spurred the development of several additional projects. Most directly is the modified BioSensor that will be a part of LEIA, which will perform its Lunar biology experiment onboard a Commercial Lunar Payload Services lander. Several search-for-life manifolds have been designed to prepare samples from icy moons for downstream analyses. Two early career Polaris projects are developing fluidics to perform genetic sequencing on samples from multigenerational cell culture and to extract and quantify target miRNAs to support astronaut radiation health assessment. Improving the readiness of these systems has been accelerated by adopting the established flight heritage and microgravity-compatibility of the Bio-CubeSat fluidic hardware and designs, while focusing development efforts on the integration of novel functionalities and components.

microfluidics↗

Laser-ablative engineering of phase singularities in plasmonic metamaterial arrays for biosensing applications

By using methods of laser-induced transfer combined with nanoparticle lithography, we design and fabricate large-area gold nanoparticle-based metamaterial arrays exhibiting extreme Heaviside-like phase jumps in reflected light due to a strong diffractive coupling of localized plasmons. When employed in sensing schemes, these phase singularities provide the sensitivity of 5 × 10{sup 4} deg. of phase shift per refractive index unit change that is comparable with best values reported for plasmonic biosensors. The implementation of sensor platforms on the basis of such metamaterial arrays promises a drastic improvement of sensitivity and cost efficiency of plasmonic biosensing devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗