Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progress at RML is improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation measurements from polar and geosynchronous satellites

Measurements of the earth's radiation budget, its climatology and its interannual variation, are described briefly. In addition, preliminary results are given on ocean energy transports, specific large scale and local radiation budget anamolies, and studies of the separate radiation budgets of the atmosphere and ocean. Initial work in preparation for additional radiation budget measurements from EOS and ATS satellites is described. A radiation budget system simulation program and several smaller projects (including a radiance normalization technique) are also mentioned. First annual global maps of the earth's radiation budget as measured from Nimbus 3 are included.

Vonderhaar, T. H.↗

Twenty Years of Radiation Measurements in Low-Earth Orbit - What Have We Learned Space Radiation Environment?

The advent of the Space Shuttle program has made possible space radiation environment measurements spanning a wide range of altitudes and orbital inclinations over multiple solar cycles. These measurements range from routine integral dose measurements with thermoluminescent dosimeters to particle energy spectra measurements made with a charged particle telescope. This paper will review the new understanding about the space radiation environment gained from this diverse data set. Major findings from these measurements include: estimations of the westward drift rate of the South Atlantic Anomaly (SAA) of 0.28-0.49/y; evidence for a northward component to the SAA drift of 0.08-0.12/y; observation of the formation and decay of the pseudo-stable additional radiation belt following the Mar 1991 SPE and geomagnetic storm with an estimated decay e-folding time of 9-10 months; observation of a local geomagnetic east-west trapped proton exposure anisotropy with an estimated magnitude of 1.6-3.3; demonstration that the trapped proton exposure in low-Earth orbit (LEO) can be reasonably modeled as a power law function of atmospheric density in the SAA region, with best correlations obtained when the exospheric temperature saturates at 938-975 K; the actual solar cycle modulation of trapped proton exposure in LEO is less than predicted by the AP8 model; and the testing and validation of GCR flux models, radiation transport codes, and dynamic geomagnetic cutoff models. Long-term, time-resolved proportional counter measurements made aboard the Mir during the same period provides further demonstration of the solar cycle modulation of the trapped protons at low altitudes - the observed modulation is also well described as power law function of atmospheric density. These data and findings have helped to improve the overall accuracy of pre-mission crew exposure projections using various semi-empirical space environment models, radiation transport codes, and spacecraft radiation shielding models. During the rise phase of solar cycle 22 (1987-1991), the RMS error between preflight exposure projections and measured crew exposure was 73%. For the rise phase of cycle 23 (1997-2001), the preflight exposure projection RMS error has decreased to 23%. The launch and assembly of the Space Station has begun a new era of long-term LEO space environment monitoring. The radiation environment at the Space Station will be monitored with three external charged particle telescopes oriented in the velocity vector, anti-velocity vector, and zenith directions. Data from the telescopes will provide charge, mass, energy, and arrival direction for incident particles with energy to mass ratios of 13- 450 MeV/amu and Z of 1-24. The external environment data will be complimented by measurements from a portable charged particle telescope and proportional counter located inside the vehicle.

Golightly, Michael J.↗

The effect of data analysis techniques on the interpretation of wide-angle longwave radiation measurements

Three different data analysis techniques - shape factor, parameter estimation, and deconvolution - have been applied to the same set of satellite radiation measurements to determine their effect on the estimated radiation field. The measurements are from a wide-angle, horizon-to-horizon, nadir-pointing sensor. The shape factor technique reduces each measurement to a radiant exitance at the top of the atmosphere by simple division by a constant. The parameter estimation technique processes all measurements together as a batch and defines the radiant exitance as a least-squares fit to the data. The deconvolution technique takes advantage of the fact that spherical harmonics are the eigenfunctions of the measurement operator. All three techniques are derived, and their assumptions, advantages and disadvantages are discussed. Their results are compared globally, zonally, regionally and on a spatial spectrum basis. All three techniques give comparable results for global parameters; however, results on a regional scale were quite different. The standard deviations of the regional differences in radiant exitance varied from 7.4 to 13.5 W/sq m. Of the three techniques, the parameter estimation technique produced the best regional results and is the choice of the author.

Green, R. N.↗

2023 Atmospheric Radiation Measurement (ARM) (Annual Report)

For more than 30 years, the Atmospheric Radiation Measurement (ARM) user facility, which is managed by the U.S. Department of Energy (DOE) Office of Science, has provided freely available data and resources to scientists worldwide. Providing these services effectively requires getting out in the field and engaging with the science community. With COVID travel restrictions behind us, we are focused on connecting in person with ARM users, establishing new partnerships, and supporting fieldwork that might have waited during the pandemic.

54 ENVIRONMENTAL SCIENCES↗

Solar-Radiation Measuring Equipment and Glossary

1976 listing of commercially available solar-radiation measuring equipment is presented in 50-page report. Sensor type, response time, cost data, and comments concerning specifications and intended usage are listed for 145 instruments from 38 manufactures.

Carter, E. A.↗

Nonequilibrium and equilibrium shock front radiation measurements

The intensities of the radiation emitted behind a normal shock wave in N were measured in an electric-arc driven shock tube at a shock velocity of 6.2 km/sec. Both a time-resolved broad-band radiation intensity measurement and a time-frozen spectral measurement were conducted. The rotational and vibrational temperatures are determined in both the equilibrium and the nonequilibrium regions. The results are compared with the similar data obtained by Allen et al. (1961). The measured rotational temperature seems to be in nonequilibrium, contradicting the two-temperature assumption of Park (1988), but the measured vibrational temperature agrees with Park's model.

Sharma, Surendra P.↗

Radiation measurements aboard Spacelab 1

The radiation environment inside Spacelab 1 was measured by a set of passive radiation detectors distributed throughout the volume inside the module, in the access tunnel, and outside on the pallet. Measurements of the low linear energy transfer (LET) component obtained from the thermoluminescence detectors ranged from 102 to 190 millirads, yielding an average low LET dose rate of 11.2 millirads/day inside the module, about twice the low LET dose rate measured on previous flights of the Space Shuttle. Because of the higher inclination of the orbit (57 versus 28.5 deg for previous Shuttle flights), substantial fluxes of highly ionizing high charge and energy galactic cosmic ray particles were observed, yielding an overall average mission dose-equivalent of about 150 millirems, more than three times higher than that measured on previous Shuttle missions.

Benton, E. V.↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

Determination of the scaled optical thickness of clouds from reflected solar radiation measurements

A method for determination of scaled optical thickness from reflected solar radiation measurements is described in which measurements of the reflected function are compared with asymptotic expressions for the reflection function of optically thick layers. Analytic formulas are derived which show the dependence of the reflection and transmission functions of nonabsorbing atmospheres on cloud optical thickness, ground albedo, and the asymmetry factor. An expression is derived which shows that the ground albedo produces a constant bias in the derived optical thickness, regardless of the value of the measured reflection function. Results from an analysis of high-resolution images, obtained in Oklahoma, of the reflection function of clouds shows the impact of details of the single scattering phase function on the derived optical thickness.

King, Michael D.↗