Reference for radiographic film interpreters

Reference of X-ray film images provides examples of weld defects, film quality, stainless steel welded tubing, and acceptable weld conditions. A summary sheet details the discrepancies shown on the film strip. This reference aids in interpreting and evaluating radiographic film of weldments.

Austin, D. L.↗

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.↗

Non-invasive assessment of otolith formation during development of the Japanese red-bellied newt, Cynops pyrrhogaster

Pre-mated adult female newts and embryos have been flown on the International Microgravity Laboratory-2 (IML-2) Space Shuttle flight in 1994 (Wiederhold et al., 1992b). With the specimens available from this flight, the calcification of otoliths, ulna, radius and backbone of the flown larvae and adult newts were analyzed. The experiments presented here studied the development of the otoliths on the ground. Otoliths of living newts, from embryo to adult, were observed in situ with the application of a new X-ray and bio-imaging analyzer system. For the establishment of this method, newts at different developmental stages were used. An imaging plate temporarily stores the X-ray energy pattern at the bio-imaging analyzer. A latent image on the imaging plate was transformed into a digital time series signal with an image reader. Acquired digital information was computed with the image processor. The processed information was recorded on film with an image recorder, in order to visualize it on an enlargement computed radiograph. To analyze development of the otoliths, photo-stimulated luminescence level was detected by an image analyzer, using transmitted X-ray photons. A single clump of otoconia could first be seen at stage 33. Stage-36 embryos first have distinguishable otoliths, with the utricle in front and saccule behind. Our results show that this X-ray method detects the otoliths equally as well as sectioning. In the newt, the mandibular/maxillary bone formed before the spine. It is suspected that for the newt embryo, living in water, feeding becomes necessary prior to support of the body.

NASA Discipline Neuroscience↗

Radiographic evidence of disuse osteoporosis in the monkey /M. nemestrina/

Radiological techniques were utilized for monitoring progressive changes in compact bone in the tibia of monkeys during experimentally induced osteopenia. Bone mass loss in the tibia during restraint was evaluated from radiographs, from bone mineral analysis, and from images reconstructed from gamma ray computerized tomography. The losses during 6 months of restraint tended to occur predominantly in the proximal tibia and were characterized by subperiosteal bone loss, intracortical striations, and scalloped endosteal surfaces. Bone mineral content in the cross section of the tibia declined 17-21%. In 6 months of recovery, the mineral content of the proximal tibia remained depressed.

Young, D. R.↗

A review of computer aided interpretation technology for the evaluation of radiographs of aluminum welds

Industrial radiography is a well established, reliable means of providing nondestructive structural integrity information. The majority of industrial radiographs are interpreted by trained human eyes using transmitted light and various visual aids. Hundreds of miles of radiographic information are evaluated, documented and archived annually. In many instances, there are serious considerations in terms of interpreter fatigue, subjectivity and limited archival space. Quite often it is difficult to quickly retrieve radiographic information for further analysis or investigation. Methods of improving the quality and efficiency of the radiographic process are being explored, developed and incorporated whenever feasible. High resolution cameras, digital image processing, and mass digital data storage offer interesting possibilities for improving the industrial radiographic process. A review is presented of computer aided radiographic interpretation technology in terms of how it could be used to enhance the radiographic interpretation process in evaluating radiographs of aluminum welds.

Lloyd, J. F., Sr.↗

Improvements in solid state radiographic converter screens.

Description of two different kinds of solid-state radiographic converter screens which have been developed. After briefly reviewing the working principles of the solid-state image converter - a sandwich type structure consisting of a photoconductive layer and an electroluminescent layer with a semiconductive layer and a black layer between them, two different kinds of radiographic converter screens are described - a radiographic amplifier screen that can be used as a substitute for the fluoroscopic screen, and a radiographic storage screen that can be used instead of radiographic films. The construction of both kinds of converters is fundamentally the same, the only difference being in the sensing photoconductive material. The radiographic amplifier screen has a moderately fast response, while the radiographic storage screen displays the image long after the irradiation is stopped.

Szepesi, Z.↗

Advancement of X-Ray Microscopy Technology and its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 micrometers can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.↗

Advancement of X-Ray Microscopy Technology and Its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 microns can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.↗

Neutron-image intensifier

Electronic intensifier tube with a demagnification ratio of 9-1 enhances the usefulness of neutron-radiographic techniques. A television signal can be obtained by optical coupling of a small-output phosphor-light image to a television camera.

Berger, H.↗

Modelling melt-solid interfaces in Bridgman growth

Doped epoxy models with abrupt interfaces were prepared to test radiographic and computer enhancement procedures used to study the images of melt-solid interfaces during crystal growth in Bridgman furnaces. A column averaging procedure resulted in improved images that faithfully reproduced the positions and shapes of interfaces even at very low density differences. These techniques were applied to lead tin telluride growing in Bridgman furnaces.

Barber, Patrick G.↗

Image analysis techniques associated with automatic data base generation.

This paper considers some basic problems relating to automatic data base generation from imagery, the primary emphasis being on fast and efficient automatic extraction of relevant pictorial information. Among the techniques discussed are recursive implementations of some particular types of filters which are much faster than FFT implementations, a 'sequential similarity detection' technique of implementing matched filters, and sequential linear classification of multispectral imagery. Several applications of the above techniques are presented including enhancement of underwater, aerial and radiographic imagery, detection and reconstruction of particular types of features in images, automatic picture registration and classification of multiband aerial photographs to generate thematic land use maps.

Bond, A. D.↗

Video enhancement of X-ray and neutron radiographs

System was devised for displaying radiographs on television screen and enhancing fine detail in picture. System uses analog-computer circuits to process television signal from low-noise television camera. Enhanced images are displayed in black and white and can be controlled to vary degree of enhancement and magnification of details in either radiographic transparencies or opaque photographs.

Vary, A.↗

Verifying X-Radiographs With Computed Tomographs

Nondestructive technique gives added confidence in inspection. Ambiguous indications in radiographic inspections of metal castings checked by computed tomography. Fast and inexpensive conventional x-ray inspection used to make film image of overall casting, and slower, more costly computed tomography used to reinspect relatively few parts of casting presenting possible diffraction patterns or other difficult-to-interpret features. Method effective in resolving ambiguities in radiographs of turbine blades. Provides same information as metallurgical sectioning.

Roy, Jagatjit↗

Determination of Local Densities in Accreted Ice Samples Using X-Rays and Digital Imaging

At the NASA Lewis Research Center's Icing Research Tunnel ice shapes, similar to those which develop in-flight icing conditions, were formed on an airfoil. Under cold room conditions these experimental samples were carefully removed from the airfoil, sliced into thin sections, and x-rayed. The resulting microradiographs were developed and the film digitized using a high resolution scanner to extract fine detail in the radiographs. A procedure was devised to calibrate the scanner and to maintain repeatability during the experiment. The techniques of image acquisition and analysis provide accurate local density measurements and reveal the internal characteristics of the accreted ice with greater detail. This paper will discuss the methodology by which these samples were prepared with emphasis on the digital imaging techniques.

Broughton, Howard↗

Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

Sargsyan, Ashot E.↗

Neutron radiographic viewing system

The design, development and application of a neutron radiographic viewing system for use in nondestructive testing applications is considered. The system consists of a SEC vidicon camera, neutron image intensifier system, disc recorder, and TV readout. Neutron bombardment of the subject is recorded by an image converter and passed through an optical system into the SEC vidicon. The vidicon output may be stored, or processed for visual readout.