Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Microwave Radiometer - UND Radiometrics MWR, Rufus - Reviewed Data

Reviewed dataset that also includes post-reprocessed level1 and level2 data files from November 2015 to May 2016 (refer to "Additional Information"). Monitor real-time profiles of temperature (K), water vapor (gm-3), relative humidity (%), and liquid water (gm-3) up to 10 km.

17 WIND ENERGY↗

PAMTRA 1.0: the Passive and Active Microwave radiative TRAnsfer tool for simulating radiometer and radar measurements of the cloudy atmosphere

Forward models are a key tool to generate synthetic observations given knowledge of the atmospheric state. In this way, they are an integral part of inversion algorithms that aim to retrieve geophysical variables from observations or in data assimilation. Their application for the exploitation of the full information content of remote sensing observations becomes increasingly important when these are used to evaluate the performance of cloud-resolving models (CRMs). Herein, CRM profiles or fields provide the input to the forward model whose simulation results are subsequently compared to the observations. This paper introduces the freely available comprehensive microwave forward model PAMTRA (Passive and Active Microwave TRAnsfer), demonstrates its capabilities to simulate passive and active measurements across the microwave spectral region for upward- and downward-looking geometries, and illustrates how the forward simulations can be used to evaluate CRMs and to interpret measurements to improve our understanding of cloud processes. PAMTRA is unique as it treats passive and active radiative transfer (RT) in a consistent way with the passive forward model providing upwelling and downwelling polarized brightness temperatures and radiances for arbitrary observation angles. The active part is capable of simulating the full radar Doppler spectrum and its moments. PAMTRA is designed to be flexible with respect to instrument specifications and interfaces to many different formats of input and output, especially CRMs, spanning the range from bin-resolved microphysical output to one- and two-moment schemes, and to in situ measured hydrometeor properties. A specific highlight is the incorporation of the self-similar Rayleigh–Gans approximation (SSRGA) for both active and passive applications, which becomes especially important for the investigation of frozen hydrometeors.

54 ENVIRONMENTAL SCIENCES↗

Passive millimeter wave radiometer system for calibration of infrared cameras

An apparatus for accurate measurement of surface and sub-surface temperatures of an object from a distance without contacting the object is provided. Illustrative embodiments provide for simultaneous measurement of thermal emission and emissivity in the mm-wave regime thereby enabling real-time non-contact measurement of emissivity. Corrected temperatures for the object which may be used for calibration of infrared thermographic cameras are determined from the measurement of emissivity.

Murphy, Ryan D.↗

Solution target for cyclotron production of radiometals

Methods of producing and isolating 68Ga, 89Zr, 64Cu, 63Zn, 86Y, 61Cu, 99mTc, 45Ti, 13N, 52Mn, or 44Sc and solution targets for use in the methods are disclosed. The methods of producing 68Ga, 89Zr, 64Cu, 63Zn, 86Y, 61Cu, 99mTc, 45Ti, 13N, 52Mn, or 44Sc include irradiating a closed target system with a proton beam. The system can include a solution target. The methods of producing isolated 68Ga, 89Zr, 64Cu, 63Zn, 86Y, 61Cu, 99mTc, 45Ti, 52Mn, or 44Sc further include isolating 68Ga, 89Zr, 64Cu, 63Zn, 86Y, 61Cu, 99mTc, 45Ti, 52Mn, or 44Sc by ion exchange chromatography. An example target includes a target body including a target cavity for receiving the target material; a housing defining a passageway for directing a particle beam at the target cavity; a target window for covering an opening of the target cavity; and a coolant gas flow path disposed in the passageway upstream of the target window.

DeGrado, Timothy R.↗

NREL Pyrheliometer Comparisons: September 23 - September 28, 2023 (NPC-2023)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, for improving our understanding of Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ACR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an quinquennial International Pyrheliometer Comparison (IPC) event for transferring the WRR to participating radiometers by invitation. The National Renewable Energy Laboratory (NREL) has represented the U.S. Department of Energy (DOE) in each IPC since 1980. And NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and it uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025-accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.

14 SOLAR ENERGY↗

New Absolute Cavity Pyrgeometer equation by application of Kirchhoff's law and adding a convection term

An equation for the Absolute Cavity Pyrgeometer (ACP) is derived from application of Kirchhoff's law and the addition of a convection term to account for the thermopile being open to the environment, unlike a domed radiometer. The equation is then used to investigate four methods to characterise key instrumental parameters using laboratory and field measurements. The first uses solar irradiance to estimate the thermopile responsivity, the second uses a minimisation method that solves for the thermopile responsivity and transmission of the cavity, and the third and fourth revisit the Reda et al. (2012) linear least squares calibration technique. Data were collected between January and November 2020, when the ACP96 and two IRIS radiometers monitoring terrestrial irradiances were available. The results indicate good agreement with IRIS irradiances using the new equation. The analysis also indicates that while the thermopile responsivity, concentrator transmission and emissivity of an ACP can be determined independently, as an open instrument, the impact of the convection term is minor in steady-state conditions but significant when the base of the instrument is being subjected to rapid artificial cooling or heating. Using laboratory characterisation of the transmission and emissivity, together with use of an estimated solar calibration of the thermopile, generated mean differences of less than 1.5 Wm -2 to the two IRIS radiometers. A minimisation method using each IRIS radiometer as the reference also provided similar results, and the derived thermopile responsivity was within 0.3 µV W -1 m 2 of the solar-calibration-derived infrared responsivity estimate of 10.5 µV W -1 m 2 estimated using a nominal solar calibration and provide irradiances within ±2 % of the terrestrial irradiance measured by the reference pyrgeometers traceable to the International System of Units (SI). The calibration method using linear least squares regression introduced by Reda et al. (2012) that relies on rapid cooling of the ACP base but utilising the new equation was found to produce consistent results but was dependent on the assumed temperature of the air above the thermopile. This study demonstrates the potential of the ACP as another independent reference radiometer for terrestrial irradiance once the magnitude of the convection coefficient and any potential variations in it have been resolved.

47 OTHER INSTRUMENTATION↗