Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman frequencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Study of Cluster Formation and its Effects on Rayleigh and Raman Scattering Measurements in a Mach 6 Wind Tunnel

Using a frequency-doubled Nd-YAG pulsed laser and a single-intensified CCD camera, Rayleigh scattering measurements have been performed to study the cluster formation in a Mach 6 wind tunnel at NASA Langley Research Center. These studies were conducted both in the free stream and in a model flow field for various flow conditions to gain an understanding of the dependence of the Rayleigh scattering (by clusters) on the local pressures and temperatures in the facility. Using the same laser system, we have also performed simultaneous measurements of the local temperature using the rotational Raman scattering of molecular nitrogen and determined the densities of molecular oxygen and nitrogen by using the vibrational Raman scattering from these species. Quantitative results will be presented in detail with emphasis on the applicability of the Rayleigh scattering for obtaining quantitative measurements of molecular densities both in the free stream and in the model flow field.

Shirinzadeh, B.↗

Optical Stark effect in the four-wave mixing and stimulated Raman spectra of N2

The influence of the optical Stark effect on spectral line shapes in four-wave-mixing Raman spectroscopy (FWMRS) and stimulated Raman spectroscopy (SRS) is investigated experimentally and theoretically. Using an experimental setup capable of rapid alternation between the simultaneous measurement of coherent Stokes Raman spectroscopy and inverse Raman spectroscopy at low and high intensities, together with a sophisticated frequency reference scheme, it was possible to perform a rather direct comparison between Stark-broadened and non-Stark-broadened spectra of both classes of Raman spectroscopies. The results demonstrate that SRS spectra show more Stark shift and broadening than their FWMRS counterparts. A discrepancy with theoretical results is pointed out, and an attempt is made to explain it.

Moosmuller, H.↗

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX

Singh, Jagdish P.↗

Frequency conversion system

Laser diode pumped mid-IR wavelength sources include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

High power pumped mid-IR wavelength systems using nonlinear frequency mixing (NFM) devices

Laser diode pumped mid-IR wavelength systems include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

High power pumped MID-IR wavelength devices using nonlinear frequency mixing (NFM)

Laser diode pumped mid-IR wavelength sources include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

Using Cloud Top Pressures Derived from Raman Scattering in the UV for the OMI Total Column Ozone Retrievals

The OMI cloud pressure product is necessary for accounting for cloud effects on the mission- critical total ozone product. One of the OM1 cloud pressure algorithms uses UV measurements to derive cloud pressures from the high frequency structure of top- of-atmosphere reflectance caused by rotational Raman scattering (RRS) in the atmosphere. RRS results in filling-in of Fraunhofer lines in the backscatter UV spectra (also known as the Ring effect). The magnitude of filling-in of the Fraunhofer lines is roughly proportional to the average number of solar photon scatterings in the atmosphere above the clouds. This property of RRS is used to deduce an effective cloud pressure. The cloud pressure algorithm retrieves the cloud pressure and cloud fraction using a concept of the Mixed Lambert Equivalent Reflectivity (MLER) also used for the TOMS-V8 OM1 total column ozone algorithm. Currently, this OMI total column ozone algorithm utilizes information about cloud top pressures from a climatology based on IR measurements. The IR-derived cloud top pressure is known to be lower than UV-derived cloud top pressure because UV radiation penetrates clouds deeper than IR radiation. That is why the UV-derived cloud pressure may be more consistent withthe total ozone algorithm. We estimate total column ozone differences caused by replacing the cloud pressure climatology with cloud pressures retrieved from GOME data same as used for retrieval of ozone.

Joiner, J.↗

Preventing Raman Lasing in High-Q WGM Resonators

A generic design has been conceived to suppress the Raman effect in whispering- gallery-mode (WGM) optical resonators that have high values of the resonance quality factor (Q). Although it is possible to exploit the Raman effect (even striving to maximize the Raman gain to obtain Raman lasing), the present innovation is intended to satisfy a need that arises in applications in which the Raman effect inhibits the realization of the full potential of WGM resonators as frequency-selection components. Heretofore, in such applications, it has been necessary to operate high-Q WGM resonators at unattractively low power levels to prevent Raman lasing. (The Raman-lasing thresholds of WGM optical resonators are very low and are approximately proportional to Q(sup -2)). Heretofore, two ways of preventing Raman lasting at high power levels have been known, but both entail significant disadvantages: A resonator can be designed so that the optical field is spread over a relatively large mode volume to bring the power density below the threshold. For any given combination of Q and power level, there is certain mode volume wherein Raman lasing does not start. Unfortunately, a resonator that has a large mode volume also has a high spectral density, which is undesirable in a typical photonic application. A resonator can be cooled to the temperature of liquid helium, where the Raman spectrum is narrower and, therefore, the Raman gain is lower. However, liquid-helium cooling is inconvenient. The present design overcomes these disadvantages, making it possible to operate a low-spectral-density (even a single-mode) WGM resonator at a relatively high power level at room temperature, without risk of Raman lasing.

Savchenkov, Anatoliy↗

Polarization Maintaining, Very-Large-Mode Area, Er Fiber Amplifier for High Energy Pulses at 1572.3 nm

We demonstrate the first polarization maintaining, very-large-mode-area Er-doped fiber amplifier with ~1000 square micron effective area. The amplifier is core pumped by a Raman fiber laser and is used to generate single frequency one microsecond pulses with pulse energy of 368 microJoules, M2 of 1.1, and polarization extinction greater than 20 dB. The amplifier operates at 1572.3 nm, a wavelength useful for trace atmospheric CO2 detection.

solid-state laser↗

Atmospheric Instrument Systems and Technology in the Goddard Earth Sciences Division

Studies of the Earth’s atmosphere require a comprehensive set of observations that rely on instruments flown on spacecraft, aircraft, and balloons as well as those deployed on the surface. Within NASA’s Goddard Space Flight Center (GSFC) Earth Sciences Division-Atmospheres, laboratories and offices maintain an active program of instrument system development and observational studies that provide: 1) information leading to a basic understanding of atmospheric processes and their relationships with the Earth’s climate system, 2) prototypes for future flight instruments, 3) instruments to serve as calibration references for satellite missions, and 4) instruments for future field validation campaigns that support ongoing space missions. Our scientists participate in all aspects of instrument activity, including component and system design, calibration techniques, retrieval algorithm development, and data processing systems. The Atmospheres Program has well-equipped labs and test equipment to support the development and testing of instrument systems, such as a radiometric calibration and development facility to support the calibration of ultraviolet and visible (UV/VIS), space-borne solar backscatter instruments. This document summarizes the features and characteristics of 46 instrument systems that currently exist or are under development. The report is organized according to active, passive, or in situ remote sensing across the electromagnetic spectrum. Most of the systems are considered operational in that they have demonstrated performance in the field and are capable of being deployed on relatively short notice. Other systems are under study or of low technical readiness level (TRL). The systems described herein are designed mainly for surface or airborne platforms. However, two Cubesat systems also have been developed through collaborative efforts. The Solar Disk Sextant (SDS) is the single balloon-borne instrument. The lidar systems described herein are designed to retrieve clouds, aerosols, methane, water vapor pressure, temperature, and winds. Most of the lasers operate at some wavelength combination of 355, 532, and 1064 nm. The various systems provide high sensitivity measurements based on returns from backscatter or Raman scattering including intensity and polarization. Measurements of the frequency (Doppler) shift of light scattered from various atmospheric constitutes can also be made. Microwave sensors consist of both active (radar) and passive (radiometer) systems. These systems are important for studying processes involving water in various forms. The dielectric properties of water affect microwave brightness temperatures, which are used to retrieve atmospheric parameters such as rainfall rate and other key elements of the hydrological cycle. Atmosphere radar systems operate in the range from 9.6 GHz to 94 GHz and have measurement accuracies from -5 to 1 dBZ; radiometers operate in the 50 GHz to 874 GHz range with accuracies from 0.5 to 1 degree K; conical and cross-track scan modes are used. Our passive optical sensors, consisting of radiometers and spectrometers, collectively operate from the UV into the infrared. These systems measure energy fluxes and atmospheric parameters such as trace gases, aerosols, cloud properties, or altitude profiles of various species. Imager spatial resolution varies from 37 m to 400 m depending on altitude; spectral resolution is as small as 0.5 nm. Many of the airborne systems have been developed to fly on multiple aircraft.

Platnick, Steven E.↗

A study of transient stimulated Raman scattering and self-focusing in the picosecond time regime

Two third order processes, stimulated Raman scattering and self-focusing, with picosecond pulses are studied. In the case of transient stimulated scattering, the gain is reduced from the steady state value, and qualitatively new features, such as shortening and delay of the Stokes pulse relative to the laser pulse, appear. These predictions are extended to realistic laser pulses, and experiments confirm all of the theoretical predictions. The self-focusing and frequency broadening of picosecond pulses is studied in the absence of stimulated Raman scattering in several materials with large orientational Kerr constants. Measurements of the relaxation time indicate that the orientational Kerr effect is important in the self-focusing of picosecond pulses. Self-focused filaments are observed to propagate with constant diameters over a distance greater than 10 cm, but disappear before the end of a 20 cm cell. The filaments radiate light continuously along their path and the spectrum of the light shows that the frequency content extends symmetrically for several hundred wave numbers on either side of the laser frequency.

Reintjes, J. F.↗

Stimulated Raman scattering of light absorbing media excited by ultrashort laser pulses

The fluctuation-dissipation theory of spontaneous and stimulated vibration Raman scattering is worked out taking into account the dissipation losses at frequencies of laser pump and scattering radiation. General expressions are found, which describe the absolute intensities and shape, energy and duration of scattered pulses in terms of the parameters of the medium and the the input laser pulses. The general regularities are analyzed in detail. Conditions are found for the realization of spontaneous or stimulated Raman scattering and its dependence on absorption, pulse duration and other parameters of the problem.

Marchevskiy, F. N.↗

Parametric instability of a relativistically strong electromagnetic wave.

The stability of a circularly polarized electromagnetic wave that is strong enough to make plasma electrons, but not ions, relativistic is studied. Small perturbations are considered which propagate parallel to the large-amplitude driver. A relativistically strong wave can be unstable on time scales as short as twice its own oscillation period, and decays into a forward-going plasma oscillation and either one or two electromagnetic waves. Ion motion introduces an additional instability which can be important at short perturbation wavelengths, where the driver would otherwise be stable. The unstable ion and electron modes both have potential for producing anomalously large acceleration of relativistic particles, as well as significant amounts of backscattered light. These effects may be important in two applications: (1) the use of intense lasers to heat or compress plasma, and (2) the plasma surrounding a pulsar, if the pulsar is losing energy by radiation of electromagnetic waves at its rotation frequency. Instability persists in the nonrelativistic regime, reducing to stimulated Raman scattering as a special case.

Max, C. E.↗

Electron cyclotron resonance deposition and plasma diagnostics of a-Si:H and a-C:H films

Amorphous silicon (a-Si:H) and amorphous carbon (a-C:H) films deposited by electron cyclotron resonance (ECR) microwave plasma-enhanced chemical vapor deposition are discussed. It is shown that the ECR microwave plasma deposition technique can produce a-Si:H films with material qualities similar to and with a deposition rate one order of magnitude higher than for films deposited by radio-frequency glow discharge. The ECR-deposited a-C:H films are characterized by fluorescence, IR, and Raman spectroscopy. In situ optical emission spectroscopy plasma diagnostics indicates that ECR plasmas have a strong emission at 434 nm, which indicates a higher chemical reactivity than radio-frequency glow discharge plasmas. The radio frequency bias to the substrate is found to play a critical role in determining the film structure and the carbon bonding configuration of ECR-deposited a-C:H films.

Shing, Y. H.↗

A spectroscopic study of intermediates in the condensation of refractory smokes: Matrix isolation experiments SiO

The infrared and Raman spectra of N2 matrix isolated silicon oxides are investigated. The vibrational frequencies of SiO, Si2O2, and Si3O3 were identified and assigned on the basis of normal coordinate analyses. Heating the solid to 50 K (evaporating the matrix) leaves a residue whose infrared spectrum is identical to that of a smoke condensed at ambient temperatures. Further heating of the sample to 500 K leads to significant changes in the band shapes. Investigations of the infrared spectra at several stages of the diffusion process result in the proposal of a mechanism for the transition from molecular properties to those of the residue (bulk) material, which is characterized as Si2O3.

Khanna, R. K.↗