Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

OrganiCam

Researchers at Los Alamos have developed OrganiCam, a compact, lightweight laser-induced fluorescence imaging camera and a Raman spectrometer for Mars caves, icy-moon and asteroid surface exploration, and terrestrial sterile laboratory use. It was designed to make remote observations in extreme environments to identify organic molecules and the biosignatures of life. OrganiCam is a bold step in a new direction—space missions need an imager that can “see” (observe and positively identify) organic molecules and potential biosignatures and direct the arm to sample the most promising locations. This ability to clearly see and characterize organic materials is exactly what OrganiCam does. We are seeking a commercialization partner to license the technology or participate in a Cooperative Research and Development Agreement (CRADA) to develop the technology into a commercial ready product for terrestrial applications.

42 ENGINEERING↗

Recombination of Hydrogen in the Iodine Reactors

The H-Canyon facility is currently dissolving spent nuclear fuel, including Material Test Reactor (MTR) and High Flux Isotope Reactor (HFIR) fuel. Dissolution of aluminum spent nuclear fuel produces hydrogen and other NOx gases. A theory long held by H-Canyon Engineering and Facility Technical Advisors that the silver nitrate-coated berl saddles, present in the iodine reactor, used for off-gas treatment were acting as a catalytic hydrogen recombiner was captured during an external review of the Accelerated Basin Deinventory program. Results from a separate SRNL project using a Raman Spectrometer to monitor the offgas from the dissolution process indicated a lack of the expected hydrogen in the off-gas stream. To test this hypothesis, a laboratory scale iodine reactor was assembled and filled with silver nitrate-coated berl saddles. Testing with this laboratory scale reactor confirmed the recombination of hydrogen when a simulated dissolver off-gas was passed through the reactor containing silver nitrate-coated berl saddles at 173-188 °C. Control experiments performed with uncoated berl saddles resulted in no change to the hydrogen concentration after passing through the reactor. The residence time of the gas in the reactor was varied to determine if residence time had an impact on the amount of hydrogen recombination occurring. Results from these experiments indicated that at the shortest residence times tested (~5 seconds) recombination of the hydrogen still exceeded 90%; however, the percent recombination did increase at longer residence times, reaching 97.9% or greater for residence times over 10 seconds. Finally, testing performed with a simplified off-gas composition containing only hydrogen and air gave similar results, indicating that the presence of NO and N 2 O gases in the stream do not play a role in the recombination reaction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

H-Canyon Dissolver Offgas Monitoring Using Raman Spectroscopy

This report describes the development and in facility demonstration of a Raman spectrometer to monitor known aluminum offgas components generated during the dissolution of Spent Nuclear Fuel at the Savannah River Site H-Canyon facility. The presence of these gases is an indicator that material is actively being dissolved. This process monitoring technique, which measures the offgas in real time, has the potential to improve the efficiency of facility operations. If the dissolution time is too short, time is wasted due to extended dissolution periods with additional probing of the dissolver pot to confirm that fragment levels are below the thresholds for continuing to the next charge or moving the dissolvent to a receiving tank. If the dissolution time is too long, time and energy are wasted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mars Mineralogy by Microbeam Raman Spectrometry

The Mars Microbeam Raman Spectrometer, under development at Washington University and the Jet Propulsion Laboratory, can identify oxide, sulfide, and oxyanion minerals, bound water and OH, and organic and graphitic carbon in Mars rocks and soils in situ. Additional information is contained in the original extended abstract.

Haskin, Larry A.↗

Versatile Vials

Advanced Fuel Research, Inc. (AFR) developed a new sol-gel material coating for sample vials to be used in surface-enhanced Raman (SER) spectroscopy. In the fields of biomedical and forensic science, the coated vials are used to identify physiological chemicals present in blood and urine. The vials are used in the pharmaceutical industry in the area of drug development and discovery. In the drug enforcement field, using the vials helps with detection of trace amounts of drugs on surfaces. The SER vials will also help to identify contaminants in water sources, such as various inorganics and pesticides. The new vials have advantages over other SER materials. Former products required that samples be pre-mixed or dissolved into specific solvents or reagents. The SER vials do not have these limitations, and measurements can be performed using any solvent. Furthermore, the signal appears in less than one second. The sol-gel material will stay active for at least one year and the vials are compatible with any Raman spectrometer. Most importantly, the SER activity can be duplicated from vial-to-vial, allowing for reproducible results.

Source record↗

Near-Field Spectroscopy with Nanoparticles Deposited by AFM

An alternative approach to apertureless near-field optical spectroscopy involving an atomic-force microscope (AFM) entails less complexity of equipment than does a prior approach. The alternative approach has been demonstrated to be applicable to apertureless near-field optical spectroscopy of the type using an AFM and surface enhanced Raman scattering (SERS), and is expected to be equally applicable in cases in which infrared or fluorescence spectroscopy is used. Apertureless near-field optical spectroscopy is a means of performing spatially resolved analyses of chemical compositions of surface regions of nanostructured materials. In apertureless near-field spectroscopy, it is common practice to utilize nanostructured probe tips or nanoparticles (usually of gold) having shapes and dimensions chosen to exploit plasmon resonances so as to increase spectroscopic-signal strengths. To implement the particular prior approach to which the present approach is an alternative, it is necessary to integrate a Raman spectrometer with an AFM and to utilize a special SERS-active probe tip. The resulting instrumentation system is complex, and the tasks of designing and constructing the system and using the system to acquire spectro-chemical information from nanometer-scale regions on a surface are correspondingly demanding.

Anderson, Mark S.↗

Drilling on the Moon and Mars: Developing the Science Approach for Subsurface Exploration with Human Crews

DOMEX (Drilling on the Moon and Mars in Human Exploration) is using analog missions to develop the approach for using human crews to perform science activities on the Moon and Mars involving exploration and sampling of the subsurface. Subsurface science is an important activity that may be uniquely enabled by human crews. DOMEX provides an opportunity to plan and execute planetary mission science activities without the expense and overhead of a planetary mission. Objectives: The objective of this first in a series of DOMEX missions were to 1) explore the regional area to understand the geologic context and determine stratigraphy and geologic history of various geologic units in the area. 2) Explore for and characterize sites for deploying a deep (10 m depth) drilling system in a subsequent field season. 3) Perform GPR on candidate drill sites. 4) Select sites that represent different geological units deposited in different epochs and collect soil cores using sterile procedures for mineralogical, organic and biological analysis. 5) Operate the MUM in 3 different sites representing different geological units and soil characteristics. 6) Collect rock and soil samples of sites visited and analyze them at the habitat. Results: At mission start the crew performed a regional survey to identify major geologic units that were correlated to recognized stratigraphy and regional geologic maps. Several candidate drill sites were identified. During the rest of the mission, successful GPR surveys were conducted in four locations. Soil cores were collected in 5 locations representing soils from 4 different geologic units, to depths up to 1m. Soil cores from two locations were analyzed with PCR in the laboratory. The remainder were reserved for subsequent analysis. XRD analysis was performed in the habitat and in the field on 39 samples, to assist with sample characterization, conservation, and archiving. MUM was deployed at 3 field locations and 1 test location (outside the habitat) where it operated autonomously for 2-4 hours at each site. Depths achieved ranged from 15 to 70 cm depending on the soil compressive strength and the presence and depth of subsurface indurated layers. Subsurface samples weighing 0.5 to 1 g were collected at the deepest depth encountered at each of the sites using the MUM automated sample collection system, and subsequently analyzed with XRD. Downhole inspection of holes produced by MUM with the Raman spectrometer was acquired on two of the holes and spectral features associated with selenite were identified in specific soil layers. Previously unreported fossilized remains of vertebrate fauna from the Jurassic era were discovered during our mission. Analysis of mineral biomarkers associated with this discovery are underway.

Stoker, C. R.↗

NASA Tech Briefs, July 2010

Topics covered include: Wirelessly Interrogated Wear or Temperature Sensors; Processing Nanostructured Sensors Using Microfabrication Techniques; Optical Pointing Sensor; Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging; High-Temperature Optical Sensor; Integral Battery Power Limiting Circuit for Intrinsically Safe Applications; Configurable Multi-Purpose Processor; Squeezing Alters Frequency Tuning of WGM Optical Resonator; Automated Computer Access Request System; Range Safety for an Autonomous Flight Safety System; Fast and Easy Searching of Files in Unisys 2200 Computers; Parachute Drag Model; Evolutionary Scheduler for the Deep Space Network; Modular Habitats Comprising Rigid and Inflatable Modules; More About N2O-Based Propulsion and Breathable-Gas Systems; Ultrasonic/Sonic Rotary-Hammer Drills; Miniature Piezoelectric Shaker for Distribution of Unconsolidated Samples to Instrument Cells; Lunar Soil Particle Separator; Advanced Aerobots for Scientific Exploration; Miniature Bioreactor System for Long-Term Cell Culture; Electrochemical Detection of Multiple Bioprocess Analytes; Fabrication and Modification of Nanoporous Silicon Particles; High-Altitude Hydration System; Photon Counting Using Edge-Detection Algorithm; Holographic Vortex Coronagraph; Optical Structural Health Monitoring Device; Fuel-Cell Power Source Based on Onboard Rocket Propellants; Polar Lunar Regions: Exploiting Natural and Augmented Thermal Environments; Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS; Improved Speed and Functionality of a 580-GHz Imaging Radar; Bolometric Device Based on Fluxoid Quantization; Algorithms for Learning Preferences for Sets of Objects; Model for Simulating a Spiral Software-Development Process; Algorithm That Synthesizes Other Algorithms for Hashing; Algorithms for High-Speed Noninvasive Eye-Tracking System; and Adapting ASPEN for Orbital Express.

Source record↗

NASAs Evolvable Mars Campaign: Mars Moons Robotic Precursor

Human exploration missions to the moons of Mars are being considered within NASA's Evolvable Mars Campaign (EMC) as an intermediate step for eventual human exploration and pioneering of the surface of Mars. A range of mission architectures is being evaluated in which human crews would explore one or both moons for as little as 14 days or for as long as 500 days with a variety of orbital and surface habitation and mobility options being considered. Relatively little is known about the orbital, surface, or subsurface characteristics of either moon. This makes them interesting but challenging destinations for human exploration missions during which crewmembers must be able to effectively conduct scientific exploration without being exposed to undue risks due to radiation, dust, micrometeoroids, or other hazards. A robotic precursor mission to one or both moons will be required to provide data necessary for the design and operation of subsequent human systems and for the identification and prioritization of scientific exploration objectives. This paper identifies and discusses considerations for the design of such a precursor mission based on current human mission architectures. Objectives of a Mars' moon precursor in support of human missions are expected to include: 1) identifying hazards on the surface and the orbital environment at up to 50-km distant retrograde orbits; 2) collecting data on physical characteristics for planning of detailed human proximity and surface operations; 3) performing remote sensing and in situ science investigations to refine and focus future human scientific activities; and 4) prospecting for in situ resource utilization. These precursor objectives can be met through a combination or remote sensing (orbital) and in-situ (surface) measurements. Analysis of spacecraft downlink signals using radio science techniques would measure the moon's mass, mass distribution, and gravity field, which will be necessary to enable trajectory planning. Laser altimetry would precisely measure the moon's shape and improve the accuracy of radio science measurements. A telescopic imaging camera would map the moon at submeter resolution and photograph selected areas of interest at subcentimeter resolution and a visible and near-infrared (0.4-3.0 mm) imaging spectrograph would produce a global map of mineral composition variations at a resolution of tens of meters and maps of selected areas of interest at meter resolution. Additional remote sensing capabilities could include a thermal infrared imager (heat flow, thermal inertia, and grain size distributions), a gamma-ray and neutron detector (atomic composition), a ground-penetrating radar (internal structure), and a magnetometer and Langmuir probe (magnetic properties and plasma field). Once on the surface of Phobos or Deimos, necessary instrumentation would include a penetrometer (regolith compressive strength), a motion-imagery camera (to observe the penetrometer tests before, during, and after contact), a dust-adhesion witness plate and camera (dust levitation), a microimager (dust particle sizes and shapes), and an alpha-proton-X-ray, X-ray fluorescence, Mossbauer, or Raman spectrometer (atomic and mineral composition of surface materials) and an optional temperature probe (regolith thermal properties). A variety of robotic mission design options to enable both orbital and surface measurements are being considered that include fully integrated and modular approaches. In-situ measurements from at least one surface location would be required, with additional measurement locations possible through use of multiple landers, through propulsive relocation of a single lander, or through electromechanical surface translation by a walking or hopping lander vehicle, which could also serve to evaluate such mobility capabilities for subsequent human missions. Preliminary orbital analysis suggests that remote sensing would likely be performed while in a distant retrograde orbit around the target moon. Mission design options to enable characterization of both Mars’ moons in a single mission are also being studied.

Gernhardt, Michael L.↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Apparatus Translates Crossed-Laser-Beam Probe Volume

Optomechanical apparatus translates probe volume of crossed-beam laser velocimeter or similar instrument while maintaining optical alignment of beams. Measures velocity, pressure, and temperature of flowing gas at several locations. Repeated tedious realignments no longer necessary. Designed to accommodate stimulated-Raman-gain spectrometer for noninvasive measurement of local conditions in flowing gas in supersonic wind tunnel. Applicable to other techniques like coherent anti-Stokes Raman spectroscopy involving use of laser beams crossed at small angles (10 degrees or less).

Herring, Gregory C.↗

Hyperspectral Raman Imaging using a Spatial Heterodyne Spectrometer (SHS)

Savannah River National Laboratory, and the larger community, has limited chemical-specific imaging capabilities, which would be beneficial for remote detection of threat chemicals or use in inaccessible and harsh environments, as well as in-line process monitoring. The project objective is to develop a novel, rugged, highly sensitive spectrometer to support real-time, chemically specific imaging using hyperspectral Raman spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First-results from the Perseverance SHERLOC Investigation: Aqueous Alteration Processes and Implications for Organic Geochemistry in Jezero Crater, Mars

The Perseverance rover landed in Jezero crater, a site selected to fulfill the Mars-2020 mission goals of characterizing the geology of habitable environments and searching for signs of life while collecting samples for return to Earth [1]. Jezero hosted an open-basin lake during the late Noachian/early Hesperian (~3.7 Ga) [1-2], has units associated with the largest carbonate deposit identified on Mars [3-4], and has a well-preserved delta with clay and carbonate-bearing sediments, well-suited to preservation of organics [1,3-4]. Investigating the nature of organics and aqueous environments within their geologic con-text allows us to understand important aqueous processes and determine habitability within Jezero crater. Previous in situ landed measurements of organics could not resolve their spatial and mineralogical con-text [5-6]. Although Martian meteorites lack geological context, the spatial distribution of organic compounds in Martian meteorites have allowed recognition of an association between aqueous processes and organics [7-8]. Here, we show for the first time in-situ associations between carbonate-forming ultramafic alteration process, later stage aqueous sulfate and perchlorate formation, and organics on the Martian surface. Methodology and geological context: We use the Perseverance rover’s SHERLOC instrument (Scanning Habitable Environments with Raman and Lumines-ence of Organics and Chemicals), a deep-ultraviolet fluorescence and Raman scattering spectrometer capable of mapping the organic and mineral composition with a spatial resolution of 100 μm resolution to report the presence of organics and aqueously formed minerals at Jezero crater [9]. These spectral detections were compared with co-located images obtained with the autofocus context imager (ACI) and the WATSON camera for textural analysis [9]. As of writing, the Per-severance rover has abraded five targets that were measured with the SHERLOC instrument. The five targets are located in two different orbitally-identified geological units within the floor of Jezero crater; the Crater Floor Fractured Rough unit (CF-Fr) and the Séítah region within the Crater Floor Fractured 1 unit (CF-F1) [10]. In orbital infrared spectroscopic data, the CF-Fr unit is associated with pyroxene spectral signatures and minor alteration, while the Séítah region is associated with olivine and minor Mg-rich carbonates and clays [3-4,10]. Carbonation of ultramafic protolith recorded within Jezero crater: All scans of abraded targets within the Séítah region reveal strong peaks at 1080–1090 cm−1 consistent with carbonate and peak singlets or doublets at 820–840 cm−1 attributed to olivine (Fig. 1), consistent with orbital infrared observations. Our detailed micron-scale petrographic and spectroscopic evidence shows that these carbonates formed through carbonation of an ultramafic protolith. The supporting observations include: (1) Carbonate cation compositions match those of olivine, suggesting mixed Fe- and Mg-olivine gave rise to mixed Fe- and Mg-carbonates, similar to observations of ultramafic systems on Earth and within Martian meteorites [3-4,7-8]. (2) The ob-served carbonates co-occur with hydrated materials, gypsum, and potentially aqueously-formed phases, amorphous silicates and phosphate. (3) The spectral and textural variation of olivine and carbonate dominated zones and olivine-carbonate mixtures within both primary grains and interstitial zones are expected for carbonated ultramafic protoliths. (4) These mineral associations and textures closely resemble those observed within the ALH84001 and Nakhlite meteorites attributed to olivine carbonation on Mars [6-7]. Taken together, micron-scale SHERLOC documentation of these phenomena bridge previous orbital and meteorite observations and demonstrate in-situ regionally extensive (~106 km2) ultramafic alteration resulting in geo-logical deposition of carbonates. Furthermore, we observe that olivine carbonation was involved in preserving and possibly synthesizing organics, which makes this environment potentially habitable, as previously suggested in [1,3-4] (Fig. 1). Late-stage aqueous perchlorate and sulfate in Jezero crater: An abrasion target within the CF-Fr unit contains combinations of high intensity 950-955 cm−1 peaks and minor 1090-1095 cm−1 and 1150-1155 cm−1 peaks that are spectral fits to anhydrous perchlorate (Fig. 1). Some spectra show a combination of 950-955 cm−1 peaks with equally strong 1010-1020 cm−1 peaks, low intensity broad features at 1120 cm−1, and occasional broad 3450 cm−1 hydration (-OH) features, indicating a mixture of Ca-sulfate and perchlorate that is minimally hydrated (Fig. 1). The detections of per-chlorates within Jezero crater differ from previous measurements (e.g. Phoenix lander, Curiosity rover, Tissint meteorite [7,11]) because they are observed to be intimately related to aqueous processes including sulfate formation, they present as a secondary white void-fill occurring within the interior of the rock, and they are found to likely be Na-perchlorate. implications for their formation: Three different types of organics embedded within three different lithologies were observed within the abraded targets. Organics associated with low intensity ~340 nm fluorescence were widespread within targets with no apparent association to particular minerals (Fig. 1). Organics associated with ~305 nm and ~275 nm fluorescence correlated with sulfates within the Bellegarde target in the CF-Fr unit, while organics associated with high intensity ~340 nm fluorescence correlated with carbonate, phosphate, and amorphous silicate mixtures within the Garde target in the Séítah region (Fig. 1). Although assignment of fluorescence signatures to specific organic compounds is not conclusive, ~340 nm fluorescence is generally more consistent with 2-ring aromatic organics, ~275 nm fluorescence is more consistent with 1-ring aromatic organics, and ~305 nm fluorescence can be created by either 2- or 1-ring aromatics [12]. These observations indicate that the strongest fluorescence signatures interpreted as organics were found in materials associated with aqueous processes, i.e. sulfate- and carbonate-bearing materials, suggesting both brines and ultramafic carbonation aqueous environments were capable of preserving organics on ancient Mars. In Martian meteorites, simple aromatic organics proposed to have been synthesized through aqueous processes can be found within minerals associated with olivine carbonation and in spatial association with perchlorate and sulfate materials [7-8], similar to SHERLOC observations. Hence, we advance an abiotic aqueous synthesis origin for the organics although we cannot rule out the presence of organics from meteoritic in-fall or putative organic biosignatures. Detailed analyses will be required upon return of these materials to Earth.

E L Scheller↗

Investigating Surface Mineralogy, Alteration Processes, and Biomarkers on Mars Using Laser Raman Spectroscopy

Despite a wealth of information from past and ongoing missions to Mars, the capability to determine the mineralogy of surface materials and to connect mineralogy with lithologic characteristics that are diagnostic of the environment in which those materials formed remains inadequate. The 2003 Mars Exploration Rovers (MER) will carry a Mini-TES and a Mossbauer spectrometer, which will provide some detailed mineralogy information. For general characterization of minerals and/or biogenic phases (reduced carbon, PAHs, etc) on the surface of Mars, we have been developing a miniaturized laser Raman spectrometer for in situ analyses -- the Mars Microbeam Raman Spectrometer, MMRS. We are also developing strategies to use Raman spectroscopy as a stand-alone technique and to be used synergistically with other in situ analysis methods in future planetary missions. Through studies of Martian meteorites and terrestrial analogs, we are gaining experience of what compositional and structural information can be obtained on key mineral groups using in-situ Raman measurements. We are developing methods for determining mineral proportions in rocks or soils and identifying rock types from sets of closely spaced, rapidly acquired spectra. We are studying how weathering and alteration affect the Raman and luminescence features of minerals and rocks, and we are investigating the Raman characteristics of biogenic organisms and their remains. These studies form the scientific basis for in-situ planetary Raman spectroscopy, and they are being done in parallel with instrument development towards a flight version of the MMRS.

Alian Wang↗

Nanostructure Diffraction Gratings for Integrated Spectroscopy and Sensing

The present disclosure pertains to metal or dielectric nanostructures of the subwavelength scale within the grating lines of optical diffraction gratings. The nanostructures have surface plasmon resonances or non-plasmon optical resonances. A linear photodetector array is used to capture the resonance spectra from one of the diffraction orders. The combined nanostructure super-grating and photodetector array eliminates the use of external optical spectrometers for measuring surface plasmon or optical resonance frequency shift caused by the presence of chemical and biological agents. The nanostructure super-gratings can be used for building integrated surface enhanced Raman scattering (SERS) spectrometers. The nanostructures within the diffraction grating lines enhance Raman scattering signal light while the diffraction grating pattern of the nanostructures diffracts Raman scattering light to different directions of propagation according to their wavelengths. Therefore, the nanostructure super-gratings allows for the use of a photodetector array to capture the surface enhanced Raman scattering spectra.

Guo, Junpeng↗