Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ramp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fluid-Thermal-Structural Interactions in Ramp-Induced Shock-Wave Boundary-Layer Interactions at Mach6

Shock-wave boundary-layer interactions (SWBLI) pose unique challenges for the slender airframes and sharp control surfaces characteristic of high-speed airbreathing aircraft. Spikes in pressure and thermal loading have been shown to occur in SWBLI regions; thus, predicting their location and behavior proves critical for assuring aircraft structural integrity and fatigue resilience. SWBLIs frequently lead to severe turbulent boundary-layer separation and corresponding unsteady motions characterized by a wide range of frequencies. Low-frequency motion has been shown to couple with the structure of a compliant panel, and turbulent boundary layers thus present a particular danger for thin control surfaces. Previous studies have shown that the thermal loading on a compliant panel in a ramp-induced SWBLI may have a signi cant impact on the panel vibrations. A multitude of studies has investigated the heating on rigid structures, but a charactrization of the heating effects on compliant structures is necessary to fully understand the fluid-thermal-structural interactions (FTSI) occurring in ramp-induced SWBLIs. This studuses infrared thermography and high-frequency Kulite pressure transducers to examine the heating loads on rigid and compliant ramps at various angles and flow conditions at Mach 6.

Hypersonic↗

Fluid-Thermal-Structural Interactions in Ramp-Induced Shock-Wave Boundary-Layer Interactions at Mach 6

Shock-wave boundary-layer interactions (SWBLI) pose unique challenges for the slender airframes and sharp control surfaces characteristic of high-speed airbreathing aircraft. Spikes in pressure and thermal loading have been shown to occur in SWBLI regions; thus, predicting their location and behavior proves critical for assuring aircraft structural integrity and fatigue resilience. SWBLIs frequently lead to severe turbulent boundary-layer separation and corresponding unsteady motions characterized by a wide range of frequencies. Low-frequency motion has been shown to couple with the structure of a compliant panel, and turbulent boundary layers thus present a particular danger for thin control surfaces. Previous studies have shown that the thermal loading on a compliant panel in a ramp-induced SWBLI may have a signi cant impact on the panel vibrations. A multitude of studies has investigated the heating on rigid structures, but a charactrization of the heating effects on compliant structures is necessary to fully understand the fluid-thermal-structural interactions (FTSI) occurring in ramp-induced SWBLIs. This studuses infrared thermography and high-frequency Kulite pressure transducers to examine the heating loads on rigid and compliant ramps at various angles and flow conditions at Mach 6.

Hypersonic↗

Ramp Traffic Console (RTC) Capabilities and Use in Operational Environment (Part 1)

This presentation provides an overview of ramp traffic control (RTC) and ramp manager traffic console (RMTC) features of ATD-2 Integrated Arrival, Departure, and Surface (IADS) system and will discuss operational use cases that cover surface metering, notification and optional hold of APREQ (approval request/call for release), EDCT (expected departure clearance time), and ground stops.

Airline Ramp Decision Support↗

Airspace Technology Demonstration II (ATD-2): American Airlines CLT Ramp Training RTC/RMTC: Baseline Integrated Arrival/ Departure/Surface (IADS) - ATD-2 Tech Transfer 1 - Phase 1

This training material was created to train CLT (Charlotte Douglas International Airport) ramp controllers on the ATD-2 (Airspace Technology Demonstration-2) system. It includes an overview of ATD-2 and the RTC/RMTC (Ramp Traffic Console/Ramp Manager Traffic Console). It discusses many interface details, data exchange and integration, metering modes, and scheduler advisories. It concludes with interactive exercises on all topics of the training course.

RTC/RMTC↗

Computer programs for pressurization (RAMP) and pressurized expulsion from a cryogenic liquid propellant tank

An analysis to predict the pressurant gas requirements for the discharge of cryogenic liquid propellants from storage tanks is presented, along with an algorithm and two computer programs. One program deals with the pressurization (ramp) phase of bringing the propellant tank up to its operating pressure. The method of analysis involves a numerical solution of the temperature and velocity functions for the tank ullage at a discrete set of points in time and space. The input requirements of the program are the initial ullage conditions, the initial temperature and pressure of the pressurant gas, and the time for the expulsion or the ramp. Computations are performed which determine the heat transfer between the ullage gas and the tank wall. Heat transfer to the liquid interface and to the hardware components may be included in the analysis. The program output includes predictions of mass of pressurant required, total energy transfer, and wall and ullage temperatures. The analysis, the algorithm, a complete description of input and output, and the FORTRAN 4 program listings are presented. Sample cases are included to illustrate use of the programs.

Masters, P. A.↗

Bayonet plug with ramp-activated lock

Matched pair of washers with broad surface ramps is locking mechanism in bayonet plug. It can be used where threaded springs and fasteners are impractical because of extreme temperatures or other environmental incompatibility. Matched pair of ramped washers is placed on plug and bayonet inserted. Inner slot of one washer matches contour of plug; this washer is stationary. Inner slot of second washer is circular. When second washer is rotated, washers push against bayonet plug, locking it in place. Retaining wire secures plug.

Wood, K. E.↗

Tangential blowing for control of strong normal shock - Boundary layer interactions on inlet ramps

The use of tangential blowing from a row of holes in an aft facing step is found to provide good control of the ramp boundary layer, normal shock interaction on a fixed geometry inlet over a wide range of inlet mass flow ratios. Ramp Mach numbers of 1.36 and 1.96 are investigated. The blowing geometry is found to have a significant effect on system performance at the highest Mach number. The use of high-temperature air in the blowing system, however, has only a slight effect on performance. The required blowing rates are significantly high for the most severe test conditions. In addition, the required blowing coefficient is found to be proportional to the normal shock pressure rise.

Schwendemann, M. F.↗

Experimental investigation of tangential blowing for control of the strong shock boundary layer interaction on inlet ramps

A 0.165-scale isolated inlet model was tested in the NASA Lewis Research Center 8-ft by 6-ft Supersonic Wind Tunnel. Ramp boundary layer control was provided by tangential blowing from a row of holes in an aft-facing step set into the ramp surface. Testing was performed at Mach numbers from 1.36 to 1.96 using both cold and heated air in the blowing system. Stable inlet flow was achieved at all Mach numbers. Blowing hole geometry was found to be significant at 1.96M. Blowing air temperature was found to have only a small effect on system performance. High blowing levels were required at the most severe test conditions.

Schwendemann, M. F.↗

Vectoring Single Expansion Ramp Nozzle (VSERN) static model test program

A variable throat-area, side-vectoring single expansion ramp nozzle (VSERN) concept's internal performance characteristics are studied with a view to controlling the bypass flow of an unmixed turbofan engine. Static tests have been conducted on VSERN at NASA-Langley using a variety of parametric models giving attention to the effects of upstream bend angle, ramp geometry, area ratio, and nozzle pressure ratio on static thrust and flow performance. Advantages of VSERN over the conventional vectoring axisymmetric convergent side-nozzles typified by those of the Harrier's Pegasus engine.

Eames, D. J. H.↗

The 3D computation of single-expansion-ramp and scramjet nozzles

A description of the computations for three-dimensional nonaxisymmetric nozzles and an analysis of the flowfields are presented. Two different types of nozzles are investigated for compressible flows at high Reynolds numbers. These are the single-expansion-ramp and scramjet nozzles. The computation for the single-expansion-ramp nozzle focuses on the condition of low pressure ratio, which requires the simulation for turbulent flow that is not needed at high pressure ratios. The flowfield contains the external quiescent air, and the internal regions of subsonic and low supersonic flows. The second type is the scramjet nozzle, which typically has a very large area ratio and is designed to operate at high speeds and pressure ratios. The freestream external flow has a Mach number of 6, and the internal flow leaving the combustion chamber is at a Mach number of 1.62. The flowfield is mostly supersonic except in the viscous region near walls. The computed results from both cases are compared with experimental data for the surface pressure distributions.

Lai, H. T.↗

Computation of turbulent, separated, unswept compression ramp interactions

Examination of the literature shows that the comparison between experiment and computation for highly separated unswept compression ramp flows is generally poor, irrespective of the turbulence model used. In general, the upstream influence is not correct, the wall pressure rise through separation is too steep, and the pressures under the separated shear layer are too high. In the current study, the objective is to determine if these discrepancies might be attributed more to other factors such as flowfield unsteadiness or three-dimensionality, rather than to inadequate turbulence modeling. To examine this possibility, multichannel wall pressure fluctuations were measured under the unsteady separation shock wave in a 28-deg unswept compression ramp flow at Mach 5. The results show that the large scale, low frequency separation shock unsteadiness controls the distribution of time-averaged surface properties and that neglect of the unsteadiness is probably the primary cause of the discrepancy between experiment and computation.

Marshall, T. A.↗

Programmable Multiple-Ramped-Voltage Power Supply

Ramp waveforms range up to 2,000 V. Laboratory high-voltage power-supply system puts out variety of stable voltages programmed to remain fixed with respect to ground or float with respect to ramp waveform. Measures voltages it produces with high resolution; automatically calibrates, zeroes, and configures itself; and produces variety of input/output signals for use with other instruments. Developed for use with ultraviolet spectrometer. Also applicable to control of electron guns in general and to operation of such diverse equipment used in measuring scattering cross sections of subatomic particles and in industrial electron-beam welders.

Ajello, Joseph M.↗

Prediction of static performance for single expansion ramp nozzles

A multiblock three-dimensional Navier-Stokes method was utilized in a two-dimensional fully implicit mode to calculate the flowfield of a single expansion ramp nozzle configuration. The code has been shown previously to be fairly accurate in predicting three-dimensional nozzle flowfields and internal performance for several axisymmetric and nonaxisymmetric geometries. A two-dimensional implementation of the method was used to reduce the resources required to obtain preliminary performance parameters of nozzle concepts. A two-dimensional description of a single-expansion ramp nozzle configuration was analyzed to verify the applicability of the Navier-Stokes code and nozzle performance package to this class of nozzles. Internal static pressure distributions, discharge coefficient and thrust ratio quantities were calculated for a range of operating conditions. Comparisons of predicted performance parameters with experimental data were within 0.5 percent for mass flow, and typically within l.5 percent for thrust ratio.

Carlson, John R.↗

Grid-refinement study of hypersonic laminar flow over a 2-D ramp

Computations were made for those test cases of Problem 3 which were designated as laminar flows, viz., test cases 3.1, 3.2, 3.4, and 3.5. These test cases corresponded to flows over a flat plate and a compression ramp at high Mach number and at high Reynolds number. The computations over the compression ramps indicate a substantial streamwise extent of separation. Based on previous experience with separated laminar flows at high Mach numbers which indicated a substantial effect with spatial grid refinement, a series of computations with different grid sizes were performed. Also, for the flat plate, comparisons of the results for two different algorithms were made.

Thomas, James L.↗

Experimental and numerical study of swept ramp injection into a supersonic flowfield

Time-averaged measurements of pressure, temperature, velocity, and injectant mole fraction are presented using the planar laser-induced iodine fluorescence (PLIIF) techniques in the complex 3D compressible flowfield around a swept ramp fuel injector. Within the range of thermodynamic conditions present in the test case studied, the technique's accuracy is estimated to be 4 percent for pressure, 4 percent for temperature, 4 percent for velocity, and 3 percent for injectant mole fraction. Comparisons to numerical simulations using the SPARK 3D Navier-Stokes computer code with an algebraic turbulence model are made at the centerplane of the flowfield as well as on three crossflow planes downstream of the injector, and good agreement is found. A weak asymmetry in the incoming flowfield appears to be amplified by boundary layer separation occuring when the the ramp generated shock reflects off the tunnel walls. In the near field of the injector, laminar calculations show better agreement to the measurements than turbulent calculations.

Donohue, James M.↗

Performance of a Blunt-lip Side Inlet with Ramp Bleed, Bypass, and a Long Constant-area Duct Ahead of the Engine : Mach Numbers 0.66 and 1.5 to 2.1

Unsteady shock-induced separation of the ramp boundary layer was reduced and stabilized more effectively by external perforations than by external or internal slots. At Mach 2.0 peak total-pressure recovery was increased from 0.802 to 0.89 and stable mass-flow range was increased 185 percent over that for the solid ramp. Peak pressure recovery occurred just before instability. The 7 and one-third-diameter duct ahead of the engine reduced large total-pressure distortions but was not as successful for small distortions as obtained with throat bleed. By removing boundary-layer air the bypass nearly recovered the total-pressure loss due to the long duct.

Allen, John L↗

Delta wing vortex manipulation using pulsed and steady blowing during ramp pitching

The effectiveness of steady and pulsed blowing as a method of controlling delta wing vortices during ramp pitching has been investigated in flow visualization experiments conducted in a water tunnel. The recessed angled spanwise blowing technique was utilized for vortex manipulation. This technique was implemented on a beveled 60 delta wing using a pair of blowing ports located beneath the vortex core at 40% chord. The flow was injected primarily in the spanwise direction but was also composed of a component normal to the wing surface. The location of vortex burst was measured as a function of blowing intensity and pulsing frequency under static conditions, and the optimum blowing case was applied at three different wing pitching rates. Experimental results have shown that, when the burst location is upstream of the blowing port, pulsed blowing delays vortex breakdown in static and dynamic cases. Dynamic tests verified the existence of a hysteresis effect and demonstrated the improvements offered by pulsed blowing over both steady blowing and no-blowing scenarios. The application of blowing, at the optimum pulsing frequency, made the vortex breakdown location comparable in static and ramp pitch-up conditions.

Moreira, J.↗