Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rated cooling capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Energy and AI: Evaluating Future Grid and Water Stress Due to Data Centers

Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This presentation highlights the grid and water implications of new data centers to support AI.

Mongird, Kendall (ORCID:0000000328077088)↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

One Earth Energy FEED Process Design Basis

This report establishes the process design basis for the front-end engineering design (FEED) of a carbon capture and injection facility at One Earth Energy's (OEE) ethanol production plant in Gibson City, Illinois, developed as part of the Illinois Storage Corridor CarbonSAFE Phase III project. The facility is designed to compress and dehydrate up to approximately 458,000 metric tonnes of CO 2 per year, sourced directly from OEE's ethanol fermenters, for permanent injection into a saline aquifer approximately four miles from the plant. At normal operating conditions, the system will process 1,290 metric tonnes of CO 2 per day, assuming 355 operating days per year and an ethanol production rate of 160 million gallons per year. The proposed process trains a multistage centrifugal blower with a five-stage reciprocating compressor, delivering CO 2 to the injection wellhead at up to 1,500 psig. Triethylene glycol (TEG) dehydration, applied after the fourth compression stage, reduces water content to a target of 10 lb/MMscf, well within the 30 lb/MMscf injection limit. Beyond dehydration, no additional treatment is required; trace impurities including oxygen and nitrogen will remain in the injected stream. Key design considerations include the absence of spare cooling tower capacity at the site, necessitating new cooling infrastructure, and the need for a new electrical substation to support large motor loads. The facility is designed for continuous, largely unattended operation, monitored around the clock by existing OEE operations staff. This document serves as the foundational reference for all subsequent detailed engineering activities associated with the OEE CO 2 injection facility.

01 COAL, LIGNITE, AND PEAT↗

Thermal Charging Rate of Composite Wax-Expanded Graphite Phase Change Materials

Phase change materials (PCMs) are valuable for their ability to store heat nearly isothermally around their phase transition temperature. PCMs are at the core of latent heat thermal energy storage (LHTES) systems, which provide the ability to buffer high thermal loads or decouple the time when heating or cooling is needed from when it is produced. Thermal charging and discharging of LHTES systems often employ a constant temperature source, and the rate at which heat can be exchanged is dependent on the thermophysical properties of the PCM. For graphite composite PCMs, the high thermal conductivity of the graphite enables an increased heat transfer rate through the material, but its presence displaces PCM which reduces the effective volumetric latent heat of the composite relative to the pure PCM. This results in a tradeoff between thermal power and volumetric energy storage capacity. The thermal charging rate is the average thermal energy stored in the material for some elapsed time. In this study, composite PCMs of compressed expanded natural graphite (CENG) and n-Octadecane are studied. Samples with varying CENG mass fractions were synthesized and the thermal charging rate was measured under a constant temperature boundary condition. For evaluation of the expanded graphite-PCM composite, one boundary of the material was exposed to a 50°C constant temperature plate, above the 27.5°C melting temperature of the PCM. The melting front progression [mm-s-1] and the thermal charging rate [W-cm-2] of the PCM were determined, and the results were compared with analytical predictions for the 1-D semi-infinite phase change. For CENG addition up to 5.75% mass fraction, a 450% thermal conductivity increase was observed with a 5% decrease in volumetric energy density as compared to pure octadecane. The average thermal charging rate was increased by over 430% for the melt to penetrate a depth of 22 mm. The experimental results matched analytical predictions, indicating that higher CENG fractions can be evaluated using analytical approaches.

Hirschey, Jason↗

Enhanced thermal reliability and performance of calcium chloride hexahydrate phase change material using cellulose nanofibril and graphene nanoplatelet

In recent years, thermal energy storage (TES) has gained attention for its role in enhancing renewable energy solutions and sustainable energy consumption. The usage of strontium chloride hexahydrate (SCH), graphene nanoplatelet (GNP), and cellulose nanofibril (CNF) additives were investigated to enhance the performance of calcium chloride hexahydrate (CCH) based on the melting/solidification behavior for TES applications. In this work, we develop a promising phase-change-material (PCM) formulation by introducing these additives that reduce supercooling, improve the thermal conductivity and stabilizing the energy storage capacity of CCH. Rheological characterizations demonstrated that the addition of 1 wt% of CNF into CCH produced the required improvement in viscosity and boosted solid-like rheological behavior. Structural characterizations show a physical mixing of the materials within the PCM composites. Our observations show that the amphiphilicity of CNF enables the surface attachment to GNP via hydrophobic interactions providing effective dispersion of GNP throughout the PCM composite. The addition of a nucleating agent, SCH decreased the degree of supercooling of ~20 g of CCH from >20 °C to 3 °C at a cooling rate of 5 °C/min. Thermal characterization showed the resulting PCM composite has a latent heat of melting of 186 Jg -1 , phase change temperature of 32 °C, and stable thermal properties after being subjected to 70 melt-freeze cycles. Adding CNF and GNP to pure CCH increased its thermal conductivity by 76 %. The high thermal conductivity of GNP and its effective dispersion by CNF is responsible for this enhancement. The study highlights the use of biodegradable nanocellulose for the preparation of sustainable PCM composites with improved performance. In conclusion, these PCM composites are scalable, they have potential to increase energy efficiency and revolutionalize the heating/cooling applications in buildings and other TES systems.

25 ENERGY STORAGE↗

Small Reactors in Microgrids: Technology Modeling and Selection (Net-Zero Microgrid Program Project Report)

This report demonstrates the capabilities of the net-zero microgrid (NZM) Xendee platform for modeling an SR module with electricity, heat extraction and thermal storage in microgrids configurations. The model effectively captures the most important technical and economic considerations for SR technology specific analysis: cost and operational characteristics of SR technology and financial costs and incentives. The model can analyze multiple scenarios to establish metrics for cost-competitive and zero-carbon microgrids connected to the grid or completely isolated. The model is fully integrated within the Xendee platform for modeling and analysis of clean energy microgrids with storage and generation from renewable energy sources. The model captures the capabilities, constraints, and nuances of SR by incorporating parameters related to plant economics, design efficiency and performance, plant operation and component and fuel lifespan. The cost and operational parameters modeled in the SR module are specific to the technology selected for integration in the microgrid. Cost parameters recognize advanced nuclear technology for modular production and installation based on economies of scale from factory manufacture and related commissioning, and cost reduction through technology maturation—first-of-a-kind (FOAK) and nth-of-a-Kind (NOAK). The cost parameters include installation, operations and maintenance (O&M), fuel refueling cycle, and reactor life. Installation cost reflects economies of scale due to unit sizing at scale and colocation. O&M economies of scale for both fixed- and variable-cost fuel life-cycle costs are incurred at every refueling interval, with separate front- and back-end fuel costs, as well as waste-handling and disposition costs. This report investigates key characteristics of different SR technologies suitable for microgrid applications, including design principles, sizing, coolant properties, temperature ratings, fuel structures, and life-cycle considerations. This also includes fuel technologies applicable to these SR systems, alongside strategies for nuclear-waste and spent-fuel management and approaches to address safety, security, and proliferation challenges. Four primary groups of SR technologies are examined: water-cooled, liquid-metal-cooled, high-temperature gas-cooled, and molten-salt-cooled systems. In this report, an initial guideline for technology selection is established, aligning the characteristics of the technologies with the requirements of microgrids. The selection of technology in a microgrid is influenced by various factors, including financial capacity, location and accessibility, demand type and characteristics, reliability and resilience requirements, area constraints, and the lifespan of the microgrid. The types of electrical and non-electrical applications within the microgrid also play a significant role in technology selection. The characteristics of SRs, such as their smaller size, modularity, transportability, long refueling interval, improved safety features, ability to operate in autonomous or semi-autonomous mode, and provision of high-grade heat, are particularly appealing for microgrids. Furthermore, a list of considerations for implementing SRs in microgrids is outlined. The SR model is created to be continuously improved with the acquisition of actual data on investment and operational costs, experience with supply chains, production at scale, and field deployments. In the near term, performance data on applications in microgrids will become available from lessons learned from laboratory tests, such as those planned for the Microreactor Applications Research Validation and Evaluation Project (MARVEL), led by Idaho National Laboratory (INL). The SR model incorporates scenario data and known SR design specifications, enabling technoeconomic analysis for SR deployment in microgrids. It specifically considers the distinctive attributes of SRs as generators in technoeconomic studies. SRs can be modeled and analyzed with generation from renewable-energy sources, energy storage, and flexible loads over a range of functionality and applications. This offers a comprehensive tool for feasibility studies, scenario development, and sensitivity analysis for “what-if” consideration of any range of assumptions about SRs in microgrids and other aggregations of distributed-energy resources, including virtual power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗

PUR-1 Water Processing and Cooling System Upgrade

The project objective was to purchase equipment related to the safety and operational capability of PUR-1. Following a 10x power uprate and the return to an active operational cycle, a water process system replacement is required to maintain the bulk coolant temperature within the bounds of the Technical Specification limit at the PUR-1. The replacement project will ensure safety and availability of the PUR-1 for long duration operational cycles and applicability to the largest possible customer base. The equipment to be purchased for this work includes a new main coolant pump rated to at least 30 gallons per minute, a heat exchanger to remove heat from the primary coolant, and a chiller system to release the heat to the environment via city water. The proposed system exactly replicates the installed system with a slight increase in capacity.

42 ENGINEERING↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical Properties of Candidate X-ray Detector Material Rb 4 Ag 2 BiBr 9

Recently, metal halide perovskites have emerged as promising semiconductor candidates for sensitive X-ray photon detection due to their suitable band gap energies, excellent charge transport properties, and low material cost afforded by their low-temperature solution-processing preparation. Furthermore, we report an improved methodology for single crystal growth and thermal and electrical properties of a two-dimensional (2D) layered halide material Rb 4 Ag 2 BiBr 9 , which has been identified as a potential candidate for X-ray radiation detection applications. The measured heat capacity for Rb 4 Ag 2 BiBr 9 implies that there are no structural phase transitions upon cooling. Temperature dependence of thermal transport measurements further suggests remarkably low thermal conductivities of Rb 4 Ag 2 BiBr 9 that are comparable to the lowest reported in literature. The bulk crystal resistivity is determined to be 2.59 × 10 9 Ω·cm from the current–voltage (I–V) curve. Density of trap states is estimated to be ~10 10 cm –3 using the space-charge-limited-current measurements. The fabricated Rb 4 Ag 2 BiBr 9 -based X-ray detector shows good operational stability with no apparent current drift, which may be ascribed to the 2D crystal structure of Rb 4 Ag 2 BiBr 9 . Finally, by varying the X-ray tube current to change the corresponding dose rate, the Rb4Ag2BiBr9 X-ray detector sensitivity is determined to be 222.03 μC Gy –1 cm –2 (at an electric field of E = 24 V/mm).

36 MATERIALS SCIENCE↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗