Search NASASearch

SEARCH · Search NASA

Results for “Reference correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Prototype Optical Correlator For Robotic Vision System

Known and unknown images fed in electronically at high speed. Optical correlator and associated electronic circuitry developed for vision system of robotic vehicle. System recognizes features of landscape by optical correlation between input image of scene viewed by video camera on robot and stored reference image. Optical configuration is Vander Lugt correlator, in which Fourier transform of scene formed in coherent light and spatially modulated by hologram of reference image to obtain correlation.

Scholl, Marija S.

Application of Gaussian Mixture Regression for the Correction of Low Cost PM2.5 Monitoring Data in Accra, Ghana

Low-cost sensors (LCSs) for air quality monitoring have enormous potential to improve air quality data coverage in resource-limited parts of the world such as sub-Saharan Africa. LCSs, however, are affected by environment and source conditions. To establish high-quality data, LCSs must be collocated and calibrated with reference grade PM2.5 monitors. From March 2020, a low-cost PurpleAir PM2.5 monitor was collocated with a Met One Beta Attenuation Monitor 1020 in Accra, Ghana. While previous studies have shown that multiple linear regression (MLR) and random forest regression (RF) can improve accuracy and correlation between PurpleAir and reference data, MLR and RF yielded suboptimal improvement in the Accra collocation (R2 = 0.81 and R2 = 0.81, respectively). We present the first application of Gaussian mixture regression (GMR) to air quality data calibration and demonstrate improvement over traditional methods by increasing the collocated PM2.5 correlation and accuracy to R2 = 0.88 and MAE = 2.2 μg/cu. m. Gaussian mixture models (GMMs) are a probability density estimator and clustering method from which nonlinear regressions that tolerate missing inputs can be derived. We find that even when given missing inputs, GMR provides better correlation than MLR and RF performed with complete data. GMR also allows us to estimate calibration certainty. When evaluated, 95% confidence intervals agreed with reference PM2.5 data 96% of the time, suggesting that the model accurately assesses its own confidence. Additionally, clustering within the GMM is consistent with climate characteristics, providing confidence that the calibration approach can learn underlying relationships in data.

Sensors

Some Analytic Results for the Study of Broadband Noise Radiation from Wings, Propellers and Jets in Uniform Motion

Alan Powell has made significant contributions to the understanding of many aeroacoustic problems, in particular, the problems of broadband noise from jets and boundary layers. In this paper, some analytic results are presented for the calculation of the correlation function of the broadband noise radiated from a wing, a propeller, and a jet in uniform forward motion. It is shown that, when the observer (or microphone) motion is suitably chosen, the geometric terms of the radiation formula become time independent. The time independence of these terms leads to a significant simplification of the statistical analysis of the radiated noise, even when the near field terms are included. For a wing in forward motion, if the observer is in the moving reference frame, then the correlation function of the near and far field noise can be related to a space-time cross-correlation function of the pressure on the wing surface. A similar result holds for a propeller in forward flight if the observer is in a reference frame that is attached to the propeller and rotates at the shaft speed. For a jet in motion, it is shown that the correlation function of the radiated noise can be related to the space-time crosscorrelation of the Lighthill stress tensor in the jet. Exact analytical results are derived for all three cases. For the cases under present consideration, the inclusion of the near field terms does not introduce additional complexity, as compared to existing formulations that are limited to the far field.

Farassat, F.

Some Analytic Results for the Study of Broadband Noise Radiation from Wings, Propellers and Jets in Uniform Motion

Alan Powell has made significant contributions to the understanding of many aeroacoustic problems, in particular, the problems of broadband noise from jets and boundary layers. In this paper, some analytic results are presented for the calculation of the correlation function of the broadband noise radiated from a wing, a propeller, and a jet in uniform forward motion. It is shown that, when the observer (or microphone) motion is suitably chosen, the geometric terms of the radiation formula become time independent. The time independence of these terms leads to a significant simplification of the statistical analysis of the radiated noise, even when the near field terms are included. For a wing in forward motion, if the observer is in the moving reference frame, then the correlation function of the near and far field noise can be related to a space-time cross-correlation function of the pressure on the wing surface. A similar result holds for a propeller in forward flight if the observer is in a reference frame that is attached to the propeller and rotates at the shaft speed. For a jet in motion, it is shown that the correlation function of the radiated noise can be related to the space-time crosscorrelation of the Lighthill stress tensor in the jet. Exact analytical results are derived for all three cases. For the cases under present consideration, the inclusion of the near field terms does not introduce additional complexity, as compared to existing formulations that are limited to the far field.

Farassat, F.

Achromatical Optical Correlator

Signal-to-noise ratio exceeds that of monochromatic correlator. Achromatical optical correlator uses multiple-pinhole diffraction of dispersed white light to form superposed multiple correlations of input and reference images in output plane. Set of matched spatial filters made by multiple-exposure holographic process, each exposure using suitably-scaled input image and suitable angle of reference beam. Recording-aperture mask translated to appropriate horizontal position for each exposure. Noncoherent illumination suitable for applications involving recognition of color and determination of scale. When fully developed achromatical correlators will be useful for recognition of patterns; for example, in industrial inspection and search for selected features in aerial photographs.

Chao, Tien-Hsin

Model correlation and damage location for large space truss structures: Secant method development and evaluation

On-orbit testing of a large space structure will be required to complete the certification of any mathematical model for the structure dynamic response. The process of establishing a mathematical model that matches measured structure response is referred to as model correlation. Most model correlation approaches have an identification technique to determine structural characteristics from the measurements of the structure response. This problem is approached with one particular class of identification techniques - matrix adjustment methods - which use measured data to produce an optimal update of the structure property matrix, often the stiffness matrix. New methods were developed for identification to handle problems of the size and complexity expected for large space structures. Further development and refinement of these secant-method identification algorithms were undertaken. Also, evaluation of these techniques is an approach for model correlation and damage location was initiated.

Smith, Suzanne Weaver

Integration of imagery and cartographic data through a common map base

Several disparate data types are integrated by using control points as the basis for spatially registering the data to a map base. The data are reprojected to match the coordinates of the reference UTM (Universal Transverse Mercator) map projection, as expressed in lines and samples. Control point selection is the most critical aspect of integrating the Thematic Mapper Simulator MSS imagery with the cartographic data. It is noted that control points chosen from the imagery are subject to error from mislocated points, either points that did not correlate well to the reference map or minor pixel offsets because of interactive cursorring errors. Errors are also introduced in map control points when points are improperly located and digitized, leading to inaccurate latitude and longitude coordinates. Nonsystematic aircraft platform variations, such as yawl, pitch, and roll, affect the spatial fidelity of the imagery in comparison with the quadrangles. Features in adjacent flight paths do not always correspond properly owing to the systematic panorama effect and alteration of flightline direction, as well as platform variations.

Clark, J.

Instrument remotely measures wind velocities

Doppler-shift spectrometer makes remote satellite measurements of atmospheric wind velocity and temperature at specified altitudes. As in correlation spectrometer, spectrum of gas in reference cell and spectrum of same gas in atmosphere are correlated both in emission and absorption.

Margolis, J. S.

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This paper presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the test section. Some icing spray clouds with large drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow in the measurement area of the probe between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a pitot-static probe affixed on the mounting plate next to the stand. Those findings were later verified in the Icing Research Tunnel using a new pitot-static probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations were performed with the airflow moving towards the probe head with a Langmuir-D 7-bin distribution cloud containing large drops. The simulation results helped identify a critical drop-size threshold of 300 μm above which the velocities of larger drops are negligibly affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This presentation presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the tunnel test section. Some icing spray clouds with large-sized drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a Pitot static probe affixed on the mounting plate. Those findings were later verified in the Icing Research Tunnel using a new Pitot probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations as airflow moving towards the probe head were run for a Langmuir-D 7-bin drop size distribution of a spray cloud with a nominally large value of medium volumetric diameter. The simulation results helped identify a critical drop-size threshold of 300 µm above which the velocities of larger drops are not affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD

Interference heating due to shock wave impingement on laminar boundary layers.

Laminar interference heating correlations have been developed based on recent experimental data obtained with wedge/flat plate models for wide ranges of Reynolds number and shock strength. Two correlation techniques were developed using the Eckert reference method. The peak interference Stanton number was first correlated with shock strength, Reynolds number, and Prandtl number based on flow conditions upstream of the interference region. The second approach was made by correlating peak interference Stanton number with only Reynolds number and Prandtl number based on downstream flow conditions. The laminar boundary layer remains laminar when both Reynolds number and shock strength are low but becomes transitional or turbulent when Reynolds number or/and shock strength are increased.

Hung, F. T.

Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

Validation Studies

Human eye movements during various forms of linear acceleration and weightlessness

Eye movements of human subjects were recorded electronystagmographically in complete darkness during rectilinear horizontal accelerations as achieved in cars on the ground and also during aircraft parabolic flight. The results were compared to the movements of blinded goldfish subjected to similar changes of gravitoinertial forces. The results indicate that there is a human correlation with the gravity reference response of fish. During horizontal forward accelerations on the ground the human eyes turn downward and during horizontal backward acceleration the eyes turn upward. The human eye response to g-loads below 1 g and to weightlessness is the reverse of the tilt of the fish. While fish dive down during low g, or loop forward during weightlessness, the eyes of subjects sitting upright in an aircraft which flies at 0 g move upward.

Vonbaumgarten, R. J.

Azimuth correlator for real-time synthetic aperture radar image processing

An azimuth correlator architecture is defined wherein a number of serial range-line buffer memories are cascaded such that the output stages of all buffer memories together form a complete and unique range bin in the azimuthal dimension at any given time. A range bin is automatically read out of the last stages of the registers in parallel on a range line sample-by-sample basis for subsequent range migration correction and correlation. Range migration correction is performed on the range bins by effectively varying the length of a delay register at the output of each range-line buffer memory. The corrected range bin output from the delay registers is then correlated with a Doppler reference function to form an image element on a real-time basis.

Arens, W. E.

Method for shaping and aiming narrow beams

A sonar method and apparatus is discribed which utilizes a linear frequency chirp in a transmitter/receiver having a correlator to synthesize a narrow beamwidth pattern from otherwise broadbeam transducers when there is relative velocity between the transmitter/receiver and the target. The chirp is so produced in a generator in bandwidth, B, and time, T, as to produce a time bandwidth product, TB, that is increased for a narrower angle. A replica of the chirp produced in a generator is time delayed and Doppler shifted for use as a reference in the receiver for correlation of received chirps from targets. This reference is Doppler shifted to select targets preferentially, thereby to not only synthesize a narrow beam but also aim the beam in azimuth and elevation.

Heyser, R. C.

Middle and high latitude Southern Hemispheric oscillations on the 35-60 day time scale

The low-frequency geopotential height fluctuations in the Southern Hemisphere were examined on the basis of one-point correlation maps. Results indicate that the 35-60 day fluctuations in the Southern-Hemisphere geopotential heights exhibit wavetrainlike characteristics. Correlations between a midlatitude reference point and tropical microwave temperature data were found to be weak, suggesting that the midlatitude wavetrain is not strongly coupled to the Madden and Julian (1971) 40-50 day oscillation.

Graves, Charles E.

A Pulse-Compression Method for Process Monitoring

This paper describes, from a deterministic view point, an on-line process monitoring method for small signal behavior of time invariant stable systems at a given operating point. The monitoring is accomplished by using an consequence modulated low-pass wavelet as the probing signal, and a cyclic reference signal as the correlator. This method allows to achieve high resolution, high signal to noise ratio monitoring, and the acquired data can be used for on-line diagnosis.

Wu, N. Eva

Rotational Alignment Altered by Source Position Correlations

In the construction of modern Celestial Reference Frames (CRFs) the overall rotational alignment is only weakly constrained by the data. Therefore, common practice has been to apply a 3-dimensional No-Net-Rotation (NNR) constraint in order to align an under-construction frame to the ICRF. We present evidence that correlations amongst source position parameters must be accounted for in order to properly align a CRF at the 5-10 (mu)as level of uncertainty found in current work. Failure to do so creates errors at the 10-40 (mu)as level.

Jacobs, Chris S.