Analytic prediction of baryonic effects from the EFT of large scale structures
We develop a method to describe analytically the effect of star formation physics on the clustering of galaxies at long distances.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
We develop a method to describe analytically the effect of star formation physics on the clustering of galaxies at long distances.
We identify 709 arc-shaped mid-infrared nebula in 24 μ m Spitzer Space Telescope or 22 μ m Wide Field Infrared Explorer surveys of the Galactic Plane as probable dusty interstellar bowshocks powered by early-type stars. About 20% are visible at 8 μ m or at shorter mid-infrared wavelengths. The vast majority (660) have no previous identification in the literature. These extended infrared sources are strongly concentrated near the Galactic mid-plane, with an angular scale height of ∼0.°6. All host a symmetrically placed star implicated as the source of a stellar wind sweeping up interstellar material. These are candidate “runaway” stars potentially having high velocities in the reference frame of the local medium. Among the 286 objects with measured proper motions, we find an unambiguous excess with velocity vectors aligned with the infrared morphology—kinematic evidence that many of these are “runaway” stars with large peculiar motions responsible for the bowshock signature. We discuss a population of “in situ” bowshocks (∼103 objects) that face giant H ii regions where the relative motions between the star and ISM may be caused by bulk outflows from an overpressured bubble. We also identify ∼58 objects that face 8 μ m bright-rimmed clouds and apparently constitute a sub-class of in situ bowshocks where the stellar wind interacts with a photoevaporative flow (PEF) from an eroding molecular cloud interface (i.e., “PEF bowshocks”). Orientations of the arcuate nebulae exhibit a correlation over small angular scales, indicating that external influences such as H ii regions are responsible for producing some bowshock nebulae. However, the vast majority of the nebulae in this sample appear to be isolated (499 objects) from obvious external influences.
The present disclosure relates to a gyroscope that makes use of a shuttle having a first plurality of fingers, a stator having a second plurality of fingers, at least one fixed support structure, and a plurality of flexors for supporting the shuttle for vibratory motion relative to the stator. The fingers of the shuttle are able to move in a vibratory motion adjacent the fingers of the stator without contacting the fingers of the stator. Portions of the fingers of at least one of the shuttle and the stator also make use of a grounded metal material layer to reduce parasitic capacitive coupling between the fingers of the shuttle and the fingers of the stator.
Purpose: We report our clinical experience using a non-invasive transperineal (TP) ultrasound (US) probe dedicated to pre-positioning and monitoring of prostate cancer patients. The accuracy of pre-treatment positioning was compared to CBCT for prostate and post-prostatectomy patients. Intrafraction motions were recorded for both localizations. The dosimetric impact of these displacements was finally investigated on prostate patients. Methods: Differences between CBCT/CT and TP-US/TP-US registrations were analyzed on 427 and 453 sessions for 13 prostate and 14 post-prostatectomy patients, respectively. Ten prostate patients’ dosimetries were retrospectively planned using 2 different protocols: 80Gy in 40 fractions and 36.25Gy in 5 fractions with a 5mm CTV- to- PTV margin. The delivery time was measured in order to analyze ranges of intrafraction motions related to each protocol. Mean prostate displacements were calculated for each patient and applied to the treatment isocenter coordinates to evaluate the dosimetric impact of these motions. Results: CBCT and TP-US shifts agreements at ±5mm were 76.6%, 95.1%, 96.3% and 90.3%, 85.0%, 97.6% in anterior- posterior, superior- inferior and left-right directions, for prostate and post-prostatectomy patients, respectively. Intrafraction motions were analyzed considering delivery times of 140 and 290s with an additional time of 120s for patient installation for doses of 2 and 7.25Gy, respectively. Intrafraction motions were patient-dependent and were larger as the irradiation time increased. Larger displacements were observed for prostate compared to post-prostatectomy localizations. Shifts above 3mm were observed on 17.6% and 4.5% of the 2Gy sessions against 30.6% and 7.3% of the 7.25Gy sessions in the anterior-posterior direction for prostate and post-prostatectomy localizations, respectively. Preliminary dosimetric results showed that intrafraction motions mainly impact the PTV coverage. Conclusion: 4D TP-US modality is a promising alternative to irradiating and/or invasive IGRT modalities for both inter and intrafraction motions management. Preliminary dosimetric results show that intrafraction monitoring is mandatory especially for hypofractionated treatments. M Fargier-Voiron was supported by a PhD grant from Elekta.
Atmospheric effects reduce the ability to detect or identify objects of interest due to spatial and spectral scintillation. Algorithms alone cannot correct for turbulence over long-range horizontal paths. While adaptive optics methods work well for astronomical viewing, they are not readily adapted for complex imagery over long-range horizontal paths. At MSS Parallel in 2016, we presented our work for the red/green/blue (RGB) wavefront sensor. Since then, we have completed our system to combine an off-the-shelf high-frame-rate USB3 color camera with a compact 90 mm Maksutov-Cassegrain telescope and an OKO deformable mirror (DM) to create a portable, real-time RGB wavefront sensor and turbulence mitigation system. The telescope’s aperture is covered with an aluminum plate holding three separate narrowband color filters. These filters, specifically matched to the relative spectral response of the sensor’s Bayer mask, provide nearly complete separation of the three color images. This device enables portable imaging through atmospheric turbulence and analysis thereof, where relative motion of the three-color Bayer-pixel video provides real-time wavefront information on the second-order statistics of Kolmogorov turbulence. We measured relative RGB pixel shifts and controlled this mirror using an ODROID single-board computer. We developed a bench setup to calibrate the relationship between pixel shifts and the deformable mirror actuators. We demonstrated the feasibility of this system on a benchtop and on scenes at 700 meters showing real time correction.
We present results from our ongoing program to map the visual orbits of pre-main sequence (PMS) binaries in the Taurus star forming region using adaptive optics imaging at the Keck Observatory. We combine our results with measurements reported in the literature to analyze the orbital motion for each binary. We present preliminary orbits for DF Tau, T Tau S, ZZ Tau, and the Pleiades binary HBC 351. Seven additional binaries show curvature in their relative motion. Currently, we can place lower limits on the orbital periods for these systems; full solutions will be possible with more orbital coverage. Five other binaries show motion that is indistinguishable from linear motion. We suspect that these systems are bound and might show curvature with additional measurements in the future. The observations reported herein lay critical groundwork toward the goal of measuring precise masses for low-mass PMS stars.
Purpose: To quantify the impact of respiratory motion on the treatment of lung tumors with spot scanning proton therapy. Methods and Materials: Four-dimensional Monte Carlo simulations were used to assess the interplay effect, which results from relative motion of the tumor and the proton beam, on the dose distribution in the patient. Ten patients with varying tumor sizes (2.6-82.3 cc) and motion amplitudes (3-30 mm) were included in the study. We investigated the impact of the spot size, which varies between proton facilities, and studied single fractions and conventionally fractionated treatments. The following metrics were used in the analysis: minimum/maximum/mean dose, target dose homogeneity, and 2-year local control rate (2y-LC). Results: Respiratory motion reduces the target dose homogeneity, with the largest effects observed for the highest motion amplitudes. Smaller spot sizes (σ ≈ 3 mm) are inherently more sensitive to motion, decreasing target dose homogeneity on average by a factor 2.8 compared with a larger spot size (σ ≈ 13 mm). Using a smaller spot size to treat a tumor with 30-mm motion amplitude reduces the minimum dose to 44.7% of the prescribed dose, decreasing modeled 2y-LC from 87.0% to 2.7%, assuming a single fraction. Conventional fractionation partly mitigates this reduction, yielding a 2y-LC of 71.6%. For the large spot size, conventional fractionation increases target dose homogeneity and prevents a deterioration of 2y-LC for all patients. No correlation with tumor volume is observed. The effect on the normal lung dose distribution is minimal: observed changes in mean lung dose and lung V{sub 20} are <0.6 Gy(RBE) and <1.7%, respectively. Conclusions: For the patients in this study, 2y-LC could be preserved in the presence of interplay using a large spot size and conventional fractionation. For treatments using smaller spot sizes and/or in the delivery of single fractions, interplay effects can lead to significant deterioration of the dose distribution and lower 2y-LC.
Purpose: Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interior. Such designs do not adequately represent respiration because the thoracic anatomy deforms internally as well as externally. In order to create a closer approximation of respiratory motion, the authors describe the construction and experimental testing of an externally as well as internally deformable, programmable lung phantom. Methods: The outer shell of a commercially available lung phantom (RS-1500, RSD, Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A custom-made insert was designed using a piece of natural latex foam block. A motion platform was programmed with sinusoidal and ten patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam “diaphragm” that compressed/decompressed the phantom interior. Experimental characterization comprised of determining the reproducibility and the external–internal correlation of external and internal marker trajectories extracted from kV x-ray fluoroscopy. Experiments were conducted to illustrate three example applications of the phantom—(i) validating the geometric accuracy of the VisionRT surface photogrammetry system; (ii) validating an image registration tool, NiftyReg; and (iii) quantifying the geometric error due to irregular motion in four-dimensional computed tomography (4DCT). Results: The phantom correctly reproduced sinusoidal and patient-derived motion, as well as realistic respiratory motion-related effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.25 mm RMS error. The motion trajectories of internal and external radio-opaque markers as measured by fluoroscopy were found to be highly correlated (R > 0.95). Using the phantom, it was demonstrated that the motion trajectories of regions-of-interest on the surface as measured by VisionRT are highly consistent with corresponding fluoroscopically acquired surface marker trajectories, with RMS errors within 0.26 mm. Furthermore, it was shown that the trajectories of external and internal marker trajectories derived from NiftyReg deformation vector fields were within 1 mm root mean square errors comparing to trajectories obtained by segmenting markers from individual fluoro frames. Finally, it was shown that while 4DCT can be used to localize internal markers for sinusoidal motion with reasonable accuracy, the localization error increases significantly (by a factor of ∼2) in the presence of cycle-to-cycle variations that are observed in patient-derived respiratory motion. Conclusions: The authors have developed a realistic externally and internally deformable, programmable lung phantom that will serve as a valuable tool for clinical and investigational motion management studies in thoracic and abdominal radiation therapies.
Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.
By the use of Einstein-Infeld-Hoffmann method, the equations of motion of a binary star system in the field of a supermassive black hole are derived. In spite of the fact that the motion of a binary system as a whole can be relativistic or even ultra-relativistic with respect to the supermassive black hole, it is shown, that under the assumption of non-relativistic relative motion of the stars in binary system, the motion of the binary system as a whole satisfies the Mathisson-Papapetrou equations with additional terms depending on quadrupole moments. Exemplary case of ultrarelativistic motion of a binary neutron star in the vicinity of non-rotating black hole is considered. It it shown that the motion of binary's center of mass may considerably differ from geodesic motion.
We study the linear stability of a planar interface separating two fluids in relative motion, focusing on conditions appropriate for the boundaries of relativistic jets. The jet is magnetically dominated, whereas the ambient wind is gas-pressure-dominated. We derive the most general form of the dispersion relation and provide an analytical approximation of its solution for an ambient sound speed much smaller than the jet Alfvén speed v A , as appropriate for realistic systems. The stability properties are chiefly determined by the angle ψ between the wavevector and the jet magnetic field. For ψ = π/2, magnetic tension plays no role, and our solution resembles the one of a gas-pressure-dominated jet. Here, only sub-Alfvénic jets are unstable ($0\lt {M}_{e}\equiv (v/{v}_{{\rm{A}}})\cos \theta \lt 1$ , where v is the shear velocity and θ the angle between the velocity and the wavevector). For ψ = 0, the free energy in the velocity shear needs to overcome the magnetic tension, and only super-Alfvénic jets are unstable ($1\lt {M}_{e}\lt \sqrt{{(1+{{\rm{\Gamma }}}_{w}^{2})/[1+({v}_{{\rm{A}}}/c)}^{2}{{\rm{\Gamma }}}_{w}^{2}]}$, with Γ w the wind adiabatic index). Our results have important implications for the propagation and emission of relativistic magnetized jets.
Purpose: Intrafractional organ motion imposes considerable challenges to scanned ion beam therapy and demands for a thorough verification of the applied treatment. At the Heidelberg Ion-Beam Therapy Center (HIT), the scanned ion beam delivery is verified by means of postirradiation positron-emission-tomography (PET) imaging. This work presents a first clinical evaluation of PET-based treatment monitoring in ion beam therapy under consideration of target motion. Methods: Three patients with mobile liver lesions underwent scanned carbon ion irradiation at HIT and postirradiation PET/CT (x-ray-computed-tomography) imaging with a commercial scanner. Respiratory motion was recorded during irradiation and subsequent image acquisition. This enabled a time-resolved (4D) calculation of the expected irradiation-induced activity pattern and, for one patient where an additional 4D CT was acquired at the PET/CT scanner after treatment, a motion-compensated PET image reconstruction. For the other patients, PET data were reconstructed statically. To verify the treatment, calculated prediction and reconstructed measurement were compared with a focus on the ion beam range. Results: Results in the current three patients suggest that for motion amplitudes in the order of 2 mm there is no benefit from incorporating respiratory motion information into PET-based treatment monitoring. For a target motion in the order of 10 mm, motion-related effects become more severe and a time-resolved modeling of the expected activity distribution can lead to an improved data interpretation if a sufficient number of true coincidences is detected. Benefits from motion-compensated PET image reconstruction could not be shown conclusively at the current stage. Conclusions: The feasibility of clinical PET-based treatment verification under consideration of organ motion has been shown for the first time. Improvements in noise-robust 4D PET image reconstruction are deemed necessary to enhance the clinical potential.
We present new [S II] images of the Herbig-Haro (HH) 30 jet and counterjet observed in 2006, 2007, and 2010 that, combined with previous data, allowed us to measure with improved accuracy the positions and proper motions of the jet and counterjet knots. Our results show that the motion of the knots is essentially ballistic, with the exception of the farthest knots, which trace the large-scale 'C'-shape bending of the jet. The observed bending of the jet can be produced by a relative motion of the HH 30 star with respect to its surrounding environment, caused either by a possible proper motion of the HH 30 star, or by the entrainment of environment gas by the red lobe of the nearby L1551-IRS5 outflow. Alternatively, the bending can be produced by the stellar wind from a nearby classical T Tauri star, identified in the Two Micron All Sky Survey catalog as J04314418+181047. The proper motion velocities of the knots of the counterjet show more variations than those of the jet. In particular, we identify two knots of the counterjet that have the same kinematic age but whose velocities differ by almost a factor of two. Thus, it appears from our observations that counterjet knots launched simultaneously can be ejected with very different velocities. We confirm that the observed wiggling of the jet and counterjet arises from the orbital motion of the jet source in a binary system. Precession, if present at all, is of secondary importance in shaping the jet. We derive an orbital period of {tau}{sub o} = 114 {+-} 2 yr and a mass function of m{mu}{sup 3}{sub c} = 0.014 {+-} 0.006 M{sub Sun }. For a mass of the system of m = 0.45 {+-} 0.04 M{sub Sun} (the value inferred from observations of the CO kinematics of the disk), we obtain a mass of m{sub j} = 0.31 {+-} 0.04 M{sub Sun} for the jet source, a mass of m{sub c} = 0.14 {+-} 0.03 M{sub Sun} for the companion, and a binary separation of a = 18.0 {+-} 0.6 AU. This binary separation coincides with the value required to account for the size of the inner hole observed in the disk, which has been attributed to tidal truncation in a binary system.
Two solitons in an optical fiber can form pairs in which the double-humped shape is maintained even when the pair is shifted in frequency by the Raman effect. We show here analytically that this is possible even when the two solitons have unequal power. We discuss the forces that cause relative motion of the two solitons, and determine a condition for balance, i.e., for a pair to maintain their separation while the phase keeps evolving. At a specific parameter point we find a solution in which even the phase profile of the pulse pair is maintained. We then discuss that this special point exists also for multipeak structures, or soliton trains. These trains can move as an entity due to Raman shifting. The results are tested by numerical simulation. A comparison to literature reveals that both the rotating phase pair and the constant phase soliton pair apparently have been seen before by others in numerical simulations. Our treatment provides the general framework.
The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.
Shear induced frictional networks have been proposed to be responsible for the emergence of discontinuous shear thickening (DST) in complex fluids. However, little experimental evidence exists to support this model directly. Here, in this study, using x-ray photon correlation spectroscopy (XPCS), we show the existence of an intrinsic heterodyne feature during shear cessation, which originates from the relative motion of mobile particles against an aggregated or jammed network induced by shear thickening. Upon removing the shear, the shear stress dissipates rather quickly in a two-step fashion, whereas the heterogeneous particle dynamics persist much longer with the relative velocity decaying slowly with time as 𝑡 −1 . More importantly, both continuous shear thickening (CST) and DST show similar heterodyne features, indicating the intrinsic mechanisms causing shear thickening are similar in nature
Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combined gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. Here,the complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.
On the basis of perturbative QCD and the relativistic quark model we calculate relativistic and bound state corrections in the production processes of a pair of S-wave and P-wave charmonium states. Relativistic factors in the production amplitude connected with the relative motion of heavy quarks and the transformation law of the bound state wave function to the reference frame of the moving S- and Pwave mesons are taken into account. For the gluon and quark propagators entering the production vertex function we use a truncated expansion in the ratio of the relative quark momenta to the center-of-mass energy {radical}s up to the second order. Relativistic corrections to the quark bound state wave functions in the rest frame are considered by means of the Breit-like potential. It turns out that the examined effects change essentially the nonrelativistic results of the cross section for the considered reactions at the center-of-mass energy {radical}s = 10.6 GeV.