At least 73 records · Page 4

The cesium bombardment engine north-south stationkeeping experiment on ATS-6

Two one millipound-thrust cesium bombardment ion thrusters have been developed and integrated on the ATS-F spacecraft for the purpose of demonstrating compatible north-south stationkeeping of a synchronous communication satellite. Preliminary operation of the two thrusters on ATS-6 was completely successful on the first run of each. In addition to verifying operation, the principal accomplishments were the demonstration of a total absence of interference with the communications systems, verification of the predicted spacecraft operating potential, demonstration of compatibility with the star tracker, and demonstration of spacecraft attitude by thrust vectoring. Subsequent attempts to operate the thrusters have not been successful. Analysis indicates that the problem is associated with operation of the propellant reservoirs in zero-g.

Worlock, R. M.↗

ATS-6 - Cesium bombardment engine north-south stationkeeping experiment

Two 0.004 N thrust cesium bombardment ion thrustors have been developed and used for north-south stationkeeping in the geostationary Applications Technology Satellite-6 (ATS-6). The thrustor subsystems are mounted on the north and south faces of the earth viewing module such that 0.0026 N of thrust is applied normal to the orbit plane and 0.0036 N is applied radially upward. The change in the orbit inclination of the satellite is maintained at zero by operating the two thrustors alternately so that their thrust components, normal to the orbital plane, are symmetrically applied about the nodal crossings. Initial operation of the thrustors was successful. There was no interference with the satellite communications systems and the predicted spacecraft operating potential was verified. Subsequent trials failed due to a defect in the operation of the propellant reservoirs in zero g. A feed line valve is under development to correct this difficulty.

Worlock, R. M.↗

The ultimate efficiency of photosensitive systems

These systems have in common two important but not independent features: they can produce a storable fuel, and they are sensitive only to radiant energy with a characteristic absorption spectrum. General analyses of the conversion efficiencies were made using the operational characteristics of each particular system. An efficiency analysis of a generalized system consisting of a blackbody source, a radiant energy converter having a threshold energy and operating temperature, and a reservoir is reported. This analysis is based upon the first and second laws of thermodynamics, and leads to a determination of the limiting or ultimate efficiency for an energy conversion system having a characteristic threshold.

Buoncristiani, A. M.↗

Miniature Reservoir Cathode: An Update

We report on recent work to produce a small low power, low cost reservoir cathode capable of long life (more than 100,000 hours) at high loading (> 5 A/sq cm). Our objective is a highly manufacturable, commercial device costing less than $30. Small highly loaded cathodes are needed, especially for millimeter wave tubes, where focusing becomes difficult when area convergence ratios are too high. We currently have 3 models ranging from .060-inch diameter to. 125-inch diameter. Reservoir type barium dispenser cathodes have a demonstrated capability for simultaneous high emission density and long life. Seven reservoir cathodes continue to operate on the cathode life test facility at NSWC, Crane, Indiana at 2 and 4 amps/sq cm. They have accumulated nearly 100,000 hours with practically no change in emission levels or knee temperature.

Vancil, Bernard K.↗

Water Membrane Evaporator

A water membrane evaporator (WME) has been conceived and tested as an alternative to the contamination-sensitive and corrosion-prone evaporators currently used for dissipating heat from space vehicles. The WME consists mainly of the following components: An outer stainless-steel screen that provides structural support for the components mentioned next; Inside and in contact with the stainless-steel screen, a hydrophobic membrane that is permeable to water vapor; Inside and in contact with the hydrophobic membrane, a hydrophilic membrane that transports the liquid feedwater to the inner surface of the hydrophobic membrane; Inside and in contact with the hydrophilic membrane, an annular array of tubes through which flows the spacecraft coolant carrying the heat to be dissipated; and An inner exclusion tube that limits the volume of feedwater in the WME. In operation, a pressurized feedwater reservoir is connected to the volume between the exclusion tube and the coolant tubes. Feedwater fills the volume, saturates the hydrophilic membrane, and is retained by the hydrophobic membrane. The outside of the WME is exposed to space vacuum. Heat from the spacecraft coolant is conducted through the tube walls and the water-saturated hydrophilic membrane to the liquid/vapor interface at the hydrophobic membrane, causing water to evaporate to space. Makeup water flows into the hydrophilic membrane through gaps between the coolant tubes.

Ungar, Eugene K.↗

Dynamic-reservoir lubricating device

Dynamic-reservoir lubricating device supplies controlled amounts of lubricating oil to ball bearings during operation of the bearings. The dynamic reservoir lubricating device includes a rotating reservoir nut, a hollow cylinder filled with lubricating oil, flow restrictors and a ball bearing retainer.

Ficken, W. H.↗

NASA’s MODIS/VIIRS Global Water Reservoir Product Suite from Moderate Resolution Remote Sensing Data

Global reservoir information can not only benefit local water management but can also improve our understanding of the hydrological cycle. This information includes water area, elevation, and storage; evaporation rate and volume values; and other characteristics. However, operational wall-to-wall reservoir storage and evaporation monitoring information is lacking on a global scale. Here we introduce NASA’s new MODIS/VIIRS Global Water Reservoir product suite based on moderate resolution remote sensing data—the Moderate Resolution Imaging Spectroradiometer (MODIS), and the Visible Infrared Imaging Radiometer Suite (VIIRS). This product consists of 8-day (MxD28C2 and VNP28C2) and monthly (MxD28C3 and VNP28C3) measurements for 164 large reservoirs (MxD stands for the product from both Terra (MOD) or Aqua (MYD) satellites). The 8-day product provides area, elevation, and storage values, which were generated by first extracting water areas from surface reflectance data and then applying the area estimations to the pre-established Area–Elevation (A–E) relationships. These values were then further aggregated to monthly, with the evaporation rate and volume information added. The evaporation rate and volume values were calculated after the Lake Temperature and Evaporation Model (LTEM) using MODIS/VIIRS land surface temperature product and meteorological data from the Global Land Data Assimilation System (GLDAS). Validation results show that the 250 m area classifications from MODIS agree well with the high-resolution classifications from Landsat (R^(2) = 0.99). Validation of elevation and storage products for twelve Indian reservoirs show good agreement in terms of R^(2) values (0.71–0.96 for elevation, and 0.79–0.96 for storage) and normalized root-mean-square error (NRMSE) values (5.08–19.34% for elevation, and 6.39–18.77% for storage). The evaporation rate results for two reservoirs (Lake Nasser and Lake Mead) agree well with in situ measurements (R^(2) values of 0.61 and 0.66, and NRMSE values of 16.25% and 21.76%). Furthermore, preliminary results from the VIIRS reservoir product have shown good consistency with the MODIS based product, confirming the continuity of this 20-year product suite. This new global water reservoir product suite can provide valuable information with regard to water-sources-related studies, applications, management, and hydrological modeling and change analysis such as drought monitoring.

Yao Li↗

A high-pressure carbon dioxide gasdynamic laser

A carbon dioxide gasdynamic laser was operated over a range of reservoir pressure and temperature, test-gas mixture, and nozzle geometry. A significant result is the dominant influence of nozzle geometry on laser power at high pressure. High reservoir pressure can be effectively utilized to increase laser power if nozzle geometry is chosen to efficiently freeze the test gas. Maximum power density increased from 3.3 W/cu cm of optical cavity volume for an inefficient nozzle to 83.4 W/cu cm at 115 atm for a more efficient nozzle. Variation in the composition of the test gas also caused large changes in laser power output. Most notable is the influence of the catalyst (helium or water vapor) that was used to depopulate the lower vibrational state of the carbon dioxide. Water caused an extreme deterioration of laser power at high pressure (100 atm), whereas, at low pressure the laser for the two catalysts approached similar values. It appears that at high pressure the depopulation of the upper laser level of the carbon dioxide by the water predominates over the lower state depopulation, thus destroying the inversion.

Kuehn, D. M.↗

Initial Testing of the Stainless Steel NaK-Cooled Circuit (SNaKC)

An actively pumped alkali metal flow circuit, designed and fabricated at the NASA Marshall Space Flight Center, is currently undergoing testing in the Early Flight Fission Test Facility (EFF-TF). Sodium potassium (NaK) was selected as the primary coolant. Basic circuit components include: simulated reactor core, NaK to gas heat exchanger, electromagnetic liquid metal pump, liquid metal flowmeter, load/drain reservoir, expansion reservoir, test section, and instrumentation. Operation of the circuit is based around the 37-pin partial-array core (pin and flow path dimensions are the same as those in a full core), designed to operate at 33 kWt. This presentation addresses the construction, fill and initial testing of the Stainless Steel NaK-Cooled Circuit (SNaKC).

Garber, Anne↗

Capabilities and Testing of the Fission Surface Power Primary Test Circuit (FSP-PTC)

An actively pumped alkali metal flow circuit, designed and fabricated at the NASA Marshall Space Flight Center, is currently undergoing testing in the Early Flight Fission Test Facility (EFF-TF). Sodium potassium (NaK), which was used in the SNAP-10A fission reactor, was selected as the primary coolant. Basic circuit components include: simulated reactor core, NaK to gas heat exchanger, electromagnetic (EM) liquid metal pump, liquid metal flowmeter, load/drain reservoir, expansion reservoir, test section, and instrumentation. Operation of the circuit is based around a 37-pin partial-array core (pin and flow path dimensions are the same as those in a full core), designed to operate at 33 kWt. NaK flow rates of greater than 1 kg/sec may be achieved, depending upon the power applied to the EM pump. The heat exchanger provides for the removal of thermal energy from the circuit, simulating the presence of an energy conversion system. The presence of the test section increases the versatility of the circuit. A second liquid metal pump, an energy conversion system, and highly instrumented thermal simulators are all being considered for inclusion within the test section. This paper summarizes the capabilities and ongoing testing of the Fission Surface Power Primary Test Circuit (FSP-PTC).

Garber, Anne E.↗

Loop Heat Pipe Startup Behaviors

A loop heat pipe must start successfully before it can commence its service. The start-up transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe start-up behaviors. Topics include the four start-up scenarios, the initial fluid distribution between the evaporator and reservoir that determines the start-up scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power start-up, and methods to enhance the start-up success. Also addressed are the thermodynamic constraint between the evaporator and reservoir in the loop heat pipe operation, the superheat requirement for nucleate boiling, pressure spike and pressure surge during the start-up transient, and repeated cycles of loop start-up andshutdown under certain conditions.

Loop Heat Pipes↗

Description and calibration of the Langley Hypersonic CF4 tunnel: A facility for simulating low gamma flow as occurs for a real gas

The Langley Hypersonic CF4 Tunnel is a Mach 6 facility which simulates an important aspect of dissociative real-gas phenomena associated with the reentry of blunt vehicles, i.e., the decrease in the ratio of specific heats (gamma) that occurs within the shock layer of the vehicle. A general description of this facility is presented along with a discussion of the basic components, instrumentation, and operating procedure. Pitot-pressure surveys were made at the nozzle exit and downstream of the exit for reservoir temperatures from 1020 to 1495 R and reservoir pressures from 1000 to 2550 psia. A uniform test core having a diameter of circa 11 in. (0.55 times the nozzle-exit diameter) exists at the maximum value of reservoir pressure and temperature. The corresponding free-stream Mach number is 5.9, the unit Reynolds number is 4 x 10 to the 5th power per foot, the ratio of specific heats immediately behind a normal shock is 1.10, and the normal-shock density ratio is 12.6. When the facility is operated at reservoir temperatures below 1440 R, irregularities occur in the pitot-pressure profile within a small region about the nozzle centerline. These variations in pitot pressure indicate the existence of flow distrubances originating in the upstream region of the nozzle. This necessitates testing models off centerline in the uniform flow between the centerline region and either the nozzle boundary layer or the lip shock originating at the nozzle exit. Samples of data obtained in this facility with various models are presented to illustrate the effect of gamma on flow conditions about the model and the importance of knowing the magnitude of this effect.

Midden, Raymond E.↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

Ku, Jentung↗

Monitoring of streamflow in the Verde River by ERTS-1 Data Collection System (DCS)

The Verde River watershed in central Arizona furnishes municipal, industrial, and agricultural water to the Salt River Valley --an area that contains more than half of Arizona's population and about one-fourth of the State's irrigated land. Water-management decisions related to the operation of large multiple-use reservoirs require accurate and continuous monitoring of moisture conditions over large remote areas. The U.S. Geological Survey in cooperation with the Salt River Valley Water Users' Association installed a specially designed gaging station on the Verde River near the town of Camp Verde to evaluate near-real time streamflow data furnished by the ERTS-1 Data Collection System (DCS). On Nov. 3, 1972, the installation was equipped with a Stevens digital water-level recorder, modified for telemetry, and an ERTS-1 data collection platform operating in the digital-parallel mode.

Schumann, H. H.↗

Engineering model 8-cm thruster subsystem

An Engineering Model (EM) 8 cm Ion Thruster Propulsion Subsystem was developed for operation at a thrust level 5 mN (1.1 mlb) at a specific impulse 1 sub sp = 2667 sec with a total system input power P sub in = 165 W. The system dry mass is 15 kg with a mercury-propellant-reservoir capacity of 8.75 kg permitting uninterrupted operation for about 12,500 hr. The subsystem can be started from a dormant condition in a time less than or equal to 15 min. The thruster has a design lifetime of 20,000 hr with 10,000 startup cycles. A gimbal unit is included to provide a thrust vector deflection capability of + or - 10 degrees in any direction from the zero position. The EM subsystem development program included thruster optimization, power-supply circuit optimization and flight packaging, subsystem integration, and subsystem acceptance testing including a cyclic test of the total propulsion package.

Herron, B. G.↗

Applications of ERTS-1 Data Collection System (DCS) in the Arizona Regional Ecological Test Site (ARETS)

The author has identified the following significant results. The DCS water-stage data from the USGS streamflow gaging station on the Verde River near Camp Verde furnished information sufficient for the accurate computation of daily mean streamflow rates during the first 2 months of operation. Daily mean flow rates computed from the DCS data agreed with those computed from the digital recorder data within + or - 5% during periods of stable or slowly changing flow and within + or - 10% during periods of rapidly changing high flow. The SRP was furnished near-real time DCS information on snow moisture content and streamflow rates for use in the management and operation of the multiple-use reservoir system. The SRP, by prudent water management and the use of near-real time hydrologic data furnished by microwave and ERTS DCS telemetry, was successful in anticipating the amount of flow into the Salt and Verde Rivers and in the subsequent release of water at rates that did not create flooding in metropolitan Phoenix. Only minor flooding occurred along the Gila River west of Phoenix. According to the Maricopa County Civil Defense agency, wage and salary losses of about $11,400,000 resulted from closing of roads across the Salt River in the winter and spring of 1972-73; however, the number and duration of the closing were minimized by use of DCS data.

Schumann, H. H.↗

Medium-Frequency Pseudonoise Georadar

Ground-probing radar systems featuring medium-frequency carrier signals phase-modulated by binary pseudonoise codes have been proposed. These systems would be used to locate and detect movements of subterranean surfaces; the primary intended application is in warning of the movement of underground water toward oil-well intake ports in time to shut down those ports to avoid pumping of water. Other potential applications include oil-well logging and monitoring of underground reservoirs. A typical prior georadar system operates at a carrier frequency of at least 50 MHz in order to provide useable range resolution. This frequency is too high for adequate penetration of many underground layers of interest. On the other hand, if the carrier frequency were to be reduced greatly to increase penetration, then bandwidth and thus range resolution would also have to be reduced, thereby rendering the system less useful. The proposed medium-frequency pseudonoise georadar systems would offer the advantage of greater penetration at lower carrier frequencies, but without the loss of resolution that would be incurred by operating typical prior georadar systems at lower frequencies.

Arendt, G. Dickey↗

Expert System For Heat Exchanger

Diagnosis simplified for non-engineers. Developmental expert-system computer program assists operator in controlling, monitoring operation, diagnosing malfunctions, and ordering repairs of heat-exchanger system dissipating heat generated by 20-kW radio transmitter. System includes not only heat exchanger but also pumps, fans, sensors, valves, reservoir, and associated plumbing. Program conceived to assist operator while avoiding cost of keeping engineer in full-time attendance. Similar programs developed for heating, ventilating, and air-conditioning systems.

Bagby, D. Gordon↗