Search NASA⌕ Search

SEARCH · Search NASA

Results for “Residential Construction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Certified Green Building Materials: Policy Impact Assessment

Chinese building construction is rapidly expanding, making it critical to focus on energy efficiency to curb the increase of energy consumption and emissions over a building’s lifetime. A key mechanism to do so is through building material certification systems and programs. These establish how building materials will perform and can be used to promote energy and resource efficiency, which help create a more sustainable and healthy building industry. This report begins by identifying characteristics of a strong certification system and ways to improve existing systems. To curb building energy demand, the Chinese government began developing a building material certification program to encourage energy and resource efficiency in the building sector. A timeline is provided of their program’s development and provides analysis. China’s building material database is highlighted and analyzed for their significance and opportunities for improvement. The report then continues to analyze the importance of policies such as procurement programs, and the Chinese government is developing their procurement programs for certified green building materials. To understand the potential large-scale impacts of green building material certifications, we conducted an analysis of the environmental and market impact of a nationwide green building procurement policy for all new residential and commercial construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Italian prototype building models for urban scale building performance simulation

Urban building energy modeling (UBEM) seeks to evaluate strategies to optimize building energy use at urban scale to support a city's building energy goals. Prototype building models are usually developed to represent typical urban building characteristics of a specific use type, construction year, and climate zone, as detailed characteristics of individual buildings at urban scale are difficult to obtain. This study investigated the Italian building stock, developing 46 building prototypes, based on construction year, for residential and office buildings. The study included 16 single-family buildings, 16 multi-family buildings, and 14 office buildings. Building envelope properties and heating, ventilation, and air conditioning system characteristics were defined according to existing building energy codes and standards for climatic zone E, which covers about half the Italian municipalities. Novel contributions of this study include (1) detailed specifications of prototype building energy models for Italian residential and office buildings that can be adopted by UBEM tools, and (2) a dataset in GeoJSON format of Italian urban buildings compiled from diverse data sources and national standards. Finally, the developed prototype building specifications, the building dataset, and the workflow can be applied to create other building prototypes and to support Italian national building energy efficiency and environmental goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

Decarbonizing residential buildings in the United States: A comparative analysis of households and construction professionals

In this study, we present a comparative analysis of surveys distributed to home occupants and construction professionals in the U.S., focused on energy upgrades and electrification retrofits that support residential building decarbonization. The surveys were executed by separate research groups and combined for this study. The study examines the decision-making, sentiments, perceptions, experiences, and practices of both groups by analyzing data from three separate surveys. These surveys assess technologies, attitudes, awareness, motivations, barriers, and opportunities related to energy retrofits and electrification. The analysis highlights key differences in the perceptions and behaviors of households and construction professionals, revealing substantial barriers to achieving decarbonization goals. For example, households cite climate change and sustainability as key motivators for pursuing energy retrofits (89%), while construction industry professionals view these themes as less important for their clients (44%). This suggests an opportunity for the construction industry to align its messaging with the values that households prioritize, helping to advance residential decarbonization. Overall, the study identifies challenges faced by both groups, factors influencing the adoption of energy-efficient practices, and inconsistencies between occupant and construction industry professionals' views. These insights contribute to the development of targeted strategies and policies to accelerate the decarbonization of residential buildings in the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safer Foundation Solar Demands Skill Collaborative

The milestones and accomplishments achieved in Safer’s Solar Demands Skill Training program required a collective effort of stakeholders. The ability to achieve the desired results and impact lives of the population we serve works best when collaborating with community stakeholders such as community-based organizations, faith-based organizations, community activists, local law enforcement, community residents, employers, and elected and appointed officials. We are working harder than ever to place clients in-demand careers and high-growth industry sectors. Our employer engagement with high growth sectors continues to increase, we have been able to deepen our relationships in this space by providing in demand stackable credential training. Launched our initiative in the green job space by partnering with organizations like ComEd, the Department of Energy, community-based organizations, faith-based organizations, and manufacturers that helped to train clients in the green jobs and renewable energy space. By the end of the year, we will have completed our tenth cohort of photovoltaic solar installation training. The training has been used as a foundation for solar panel installers to acquire new skills in in the green jobs career pathways, such as sales and customer service. It has also served as a pipeline to union-level trade positions through the skills participants obtained through partnership engagement. Safer Foundation's policy and advocacy team plays a major role in expanding opportunities for people with records to over one hundred occupations, including the trades. This reform has allowed many to secure living wage employment, reducing the high recidivism rate within Illinois. Safer continues to build our social enterprise with Reconstructive Technology Partners (RTP). RTP is introducing people with records to the construction trades such as solar, carpentry and electrical through residential remodeling of homes on smaller construction projects. Understanding the need to have a greater community presence, outreach was extended to a boots on the ground model, including, but not limited to door-to-door engagement, DE-EE0008571 Safer Foundation Page 4 of 29 local radio broadcasting and print ads in local newspapers. We continue to seek innovative ways to increase Safer Foundations' presence in the renewable energy space. Outreach efforts gave us an opportunity to share critical reentry information and opportunities about our PV installer program. Giving us reach with local and national audiences alike. We launched a systematic approach to improving client data and client tracking through an evidence-based practices initiative. That implemented an agency wide cross-functional data management system. The system supported our goal of reviewing, evaluating, and making recommendations to improve operational processes, program delivery, information sharing, and more. Played a significant part in the success of the solar program. Finally, economists around the nation agree that there is a significant labor shortage. The shortage directly threatens our ability to sustain our economic growth; if employers do not have access to the workers they need, it can lead to a shutdown in the economic recovery. The demand for Safer Foundation services is more important and impactful than ever. We will continue to build upon our 50 years of experience to address the challenges ahead and serve more people in a better way. We are confident we will accomplish beautiful things that benefit everyone involved because together, we are powerful.

14 SOLAR ENERGY↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

Comparative life cycle assessment of a modular cross-laminated timber residential building designed for disassembly and reuse versus traditional wood frame construction

There is a need for affordable housing across the U.S., with high-performance modular and prefabricated buildings providing a logical avenue for meeting some of this demand. However, there is a need to balance high performance construction – including low emissions – with affordability. To provide a proof-of-concept in meeting these goals, the Circular Home is a cross-laminated timber (CLT)-based deconstructible and reconfigurable single-family residence that meets high performance targets in moisture, energy, design, economics, and life cycle assessment (LCA). This study focuses on the LCA, presenting a cradle-to-cradle whole-building life cycle assessment (WBLCA) for the Circular Home and a functionally equivalent Baseline Home constructed with traditional materials and methods. The functional unit is 1 m 2 of gross floor area across 60 years. Revit building information models (BIM) provided material quantities and Tally LCA was utilized for impact data (inclusive of biogenic carbon sequestration), supplemented with manufacturer environmental product declarations (EPDs). The Circular Home outperforms the baseline residence in most measured impact categories, including global warming potential (GWP), producing −2.73 kgCO 2 eq/m 2 in embodied emissions, whereas the modeled baseline has an embodied GWP of 428 kgCO 2 eq/m 2 . The careful material selection and advanced building design optimizes performance, with the Circular Home containing only −0.006 times the embodied emissions and −0.02 times the operational emissions of its traditional counterpart. Finally, the unique contribution of this work is in the environmental impact comparison of a high-performance modular CLT structure that can be affordably scaled and mass produced in a U.S. market, compared to typical single family home construction.

Circularity↗

Inequality in the availability of residential air conditioning across 115 US metropolitan areas

Continued climate change is increasing the frequency, severity, and duration of populations’ high temperature exposures. Indoor cooling is a key adaptation, especially in urban areas, where heat extremes are intensified—the urban heat island effect (UHI)—making residential air conditioning (AC) availability critical to protecting human health. In the United States, the differences in residential AC prevalence from one metropolitan area to another is well understood, but its intra-urban variation is poorly characterized, obscuring neighborhood-scale variability in populations’ heat vulnerability and adaptive capacity. We address this gap by constructing empirically derived probabilities of residential AC for 45,995 census tracts across 115 metropolitan areas. Within cities, AC is unequally distributed, with census tracts in the urban “core” exhibiting systematically lower prevalence than their suburban counterparts. Moreover, this disparity correlates strongly with multiple indicators of social vulnerability and summer daytime surface UHI intensity, highlighting the challenges that vulnerable urban populations face in adapting to climate-change driven heat stress amplification.

54 ENVIRONMENTAL SCIENCES↗

Assessing the New Home Market Opportunity: Case Study and Cost Modeling for Solar and Storage in 2030

Residential solar and storage markets are growing in the United States. With approximately 1 million new homes constructed every year, this represents a significant opportunity for solar and storage installations. Some homebuilders have begun to build new homes with solar and storage included as a standard offering. It is not clear how solar and storage is incorporated into the new construction process and at what cost. Further, it is unclear what barriers or opportunities exist to scale this model nationwide. To fill this gap in the literature, this research conducts a case study of Mandalay Homes' new solar and storage community in Arizona to gather lessons learned. From this foundation, we further generate a set of pathways to reduce install costs and expand solar and storage market penetration in this sector. To model existing and 2030 solar and storage costs, we use the National Renewable Energy Laboratory's (NREL's) bottom-up cost model. This modeling is further informed by 12 interviews conducted with new home builders, solar contractors, and other subject matter expert organizations. Our case study analysis generated three key considerations for other homebuilders including: 1. Educating local permitting, inspection, and in some cases utility officials on solar and storage products, designs, and code compliant building practices may be required. The need for education may decline as more local governments and utilities review and approve solar and storage projects. 2. Incorporating solar and storage systems into the homebuilding process can add complexity and related coordination challenges. This does not need to result in home construction delays, but can result in costly contractor "dry runs" to construction sites. 3. Deploying solar and storage at the time of new construction has significant economies of scale, which can improve the value proposition of the systems. The case study, extant literature, and interviews were used to model both existing and future solar and storage installation costs at time of new construction. Here, we find three key cost reduction opportunities relating to solar and battery storage hardware, customer acquisition, and overhead. If future contractors can maximize the cost reduction opportunities outlined here, residential new construction costs could decline by 8 - 25% by 2030, depending on the modeled scenario. Though we expect costs to decline through 2030, it is unclear which of these scenarios may ultimately appear. Interviewees further identified a variety of barriers across each cost category that could temper the savings shown here. At the same time, interviewees described several pathways to scale the new construction solar and storage market, beyond installation cost savings. Interviewees confirmed that changes in finance, rate design, resilience policies, deployment mandates, and DER aggregation could all support more market adoption than seen today. These findings suggest that there are significant opportunities to expand new construction markets and this research can serve as a baseline to assess progress in this segment through 2030.

14 SOLAR ENERGY↗

Oregon Residential Energy Code Field Study

A research project in the state of Oregon identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in November 2019; data collection began in November 2019 and continued through February 2020. Analysis of the data has led to a better understanding of the energy features present in homes and identified over $600,000 in potential annual savings to Oregon homeowners that could result from increased compliance with the 2017 Oregon Residential Specialty Code (2017 ORSC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental exposure to industrial air pollution is associated with decreased male fertility

Objective: To understand how chronic exposure to industrial air pollution is associated with male fertility through semen parameters. Design: Retrospective cohort study. Subjects: Men in the Subfertility, Health and Assisted Reproduction cohort who underwent a semen analysis 2005-2017 with ≥1 measured semen parameter (N=21,563). Intervention(s): Residential histories for each man were constructed using locations from administrative records linked through the Utah Population Database. Industrial facilities with air emissions of nine endocrine disrupting compound chemical classes were identified from the Environmental Protection Agency Risk-Screening Environmental Indicators microdata. Chemical levels were linked with residential histories for the 5 years prior to each semen analysis. Main Outcome Measures: Semen analyses were classified as azoospermic or oligozoospermic (< 15 M/mL) using World Health Organization cutoffs for concentration. Bulk semen parameters such as concentration, total count, ejaculate volume, total motility, total motile count, and total progressive motile count were also measured. Multivariable regression models with robust standard errors were used to associate exposure quartiles for each of the nine chemical classes with each semen parameter, adjusting for age, race, and ethnicity, as well as neighborhood socioeconomic disadvantage. Results: After adjustment for demographic covariates, several chemical classes were associated with azoospermia and decreased total motility and volume. For exposure in the 4th relative to 1st quartile, significant associations were observed for acrylonitrile (β total motility = -0.87 pp), aromatic hydrocarbons (odds ratio [OR]azoospermia = 1.53; β volume = -0.14 mL), dioxins (OR azoospermia = 1.31; β volume = -0.09 mL; β total motility = -2.65 pp), heavy metals (β total motility = -2.78pp), organic solvents (OR azoospermia = 1.75; β volume = -0.10 mL), organochlorines (OR azoospermia = 2.09; β volume = -0.12 mL), phthalates (OR azoospermia = 1.44; β volume = -0.09 mL; β total motility = -1.21 pp), and silver particles (OR azoospermia = 1.64; β volume = -0.11 mL). All semen parameters significantly decreased with increasing socioeconomic disadvantage. Men who lived in the most disadvantaged areas had concentration, volume, and total motility of 6.70 M/mL, 0.13 mL, and 1.79 pp lower, respectively. Count, motile count, and total progressive motile count all decreased by 30–34 M.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development and Validation of Home Comfort System for Total Performance Deficiency/Fault Detection and Optimal Comfort Control

In this project, we developed and tested a learning-based home thermal model that facilitates the operation of a model predictive control (MPC)-based optimization agent and an automated fault detection and diagnosis (AFDD) agent. The home thermal model was constructed using a two-node resistor-capacitor model. Moreover, two accompanying parameter identification methods were introduced, least-squares and optimization. Based on the home thermal model, the MPC-based optimization agent was developed to optimize residential HVAC operation. Using two FDD methods, the AFDD agent was constructed to detect and diagnose two prevalent residential AC faults, airflow reduction and refrigerant undercharge. The home thermal model, along with the MPC-based optimization agent and AFDD agent, were tested at the Norman Test House, Miami Test House, Pacific Northwest National Laboratory (PNNL) Test House A, and PNNL Test House B. Finally, they were also field tested in nine demonstration homes with real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Colorado Residential Resiliency and Managed Charging

Validate and model impacts of electric vehicle (EV) home charging on service transformers; analyze diverse grid locations and configurations to determine 'risk factors'; finalize/deliver new design tools and typical EV load curves; improve/issue new construction standards for transformers, secondaries, and services. To ensure residential charging equity, smart charge management strategies will be studied and analyzed with the goal of creating affordable demand charges for customers.

33 ADVANCED PROPULSION SYSTEMS↗