At least 73 records · Page 4

GE 1.5 ESS Wind Turbine Retrofit Controller Development (CRADA Final Report)

National Renewable Energy Laboratory (NREL) and Bachmann electronic corp. will collaborate on the development of a software application to be used on an existing aftermarket Bachmann controller, utilizing and existing Bachmann software platform, which will be used on the General Electric (GE) 1.5 ESS wind turbine. This retrofit will significantly enhance NREL’s ability to control experiments it is planning to conduct on the GE 1.5 wind turbine as part of the Gearbox Reliability Collaborative, Atmosphere to Electrons and other future R&D. The proposed work is leveraging ongoing Department of Energy (DOE) Annual Operating Plan activities on the GE 1.5 ESS wind turbine at the National Wind Technology Center.

17 WIND ENERGY↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Countrywide LED Lighting Retrofit for Safety, Visibility, and Energy Efficiency (Final Technical Report)

The project supported national clean energy goals by reducing electricity demand and improving energy efficiency in public infrastructure. Tasks defined in the Statement of Project Objectives included site assessments, retrofit planning, lighting design optimization, installation, monitoring, and reporting. All milestones and go/no-go decision points were successfully met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar energy for process heat: Design/cost studies of four industrial retrofit applications

Five specific California plants with potentially attractive solar applications were identified in a process heat survey. These five plants were visited, process requirements evaluated, and conceptual solar system designs were generated. Four DOE (ERDA) sponsored solar energy system demonstration projects were also reviewed and compared to the design/cost cases included in this report. In four of the five cases investigated, retrofit installations providing significant amounts of thermal energy were found to be feasible. The fifth was rejected because of the condition of the building involved, but the process (soap making) appears to be an attractive potential solar application. Costs, however, tend to be high. Several potential areas for cost reduction were identified including larger collector modules and higher duty cycles.

French, R. L.↗

Solar energy retrofit for Clarksville Middle School, Clarksville, Indiana

The solar energy retrofit heating system installed to provide heating for two gymnasiums at the Clarksville Middle School located in Clarksville, Indiana is described in detail. The system type is hot water using existing chilled water piping and chilled water coils in an air handler system. Flat plate, single-glazed selectively coated solar collectors were installed on the roof of each gymnasium. Total collector area covers 6,520 square feet. The liquid is stored in a 10,000 gallon steel tank installed below grade.

Source record↗

Parametric tests of a traction drive retrofitted to an automotive gas turbine

The results of a test program to retrofit a high performance fixed ratio Nasvytis Multiroller Traction Drive in place of a helical gear set to a gas turbine engine are presented. Parametric tests up to a maximum engine power turbine speed of 45,500 rpm and to a power level of 11 kW were conducted. Comparisons were made to similar drives that were parametrically tested on a back-to-back test stand. The drive showed good compatibility with the gas turbine engine. Specific fuel consumption of the engine with the traction drive speed reducer installed was comparable to the original helical gearset equipped engine.

Rohn, D. A.↗

Motel DHW Retrofit--Dallas, Texas

Solar-energy system designed to provide 65% of total domestic-hot-water (DHW) demands for 100-room motel in Dallas, Texas is subject of a report now available. System is retrofit, and storage-tank size was limited to 1,000 gallons (3,785 1) by size of room where it is located.

Source record↗

Retrofit and acceptance test of 30-cm ion thrusters

Six 30 cm mercury thrusters were modified to the J-series design and evaluated using standardized test procedures. The thruster performance meets the design objectives (lifetime objective requires verification), and documentation (drawings, etc.) for the design is completed and upgraded. The retrofit modifications are described and the test data for the modifications are presented and discussed.

Poeschel, R. L.↗

Retrofit energy conservation in residential buildings in southern California

The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

Turner, R. H.↗

Retrofitting Vibration Dampers

Method of installing support tubes allows retrofitting of vibrationreducing elements. Tubes deform elastically as inserted and expand partially as gap becomes wider. Force-fit tubes eliminate fatigue problem.

Adams, T. C.↗

A graphics subsystem retrofit design for the bladed-disk data acquisition system

A graphics subsystem retrofit design for the turbojet blade vibration data acquisition system is presented. The graphics subsystem will operate in two modes permitting the system operator to view blade vibrations on an oscilloscope type of display. The first mode is a real-time mode that displays only gross blade characteristics, such as maximum deflections and standing waves. This mode is used to aid the operator in determining when to collect detailed blade vibration data. The second mode of operation is a post-processing mode that will animate the actual blade vibrations using the detailed data collected on an earlier data collection run. The operator can vary the rate of payback to view differring characteristics of blade vibrations. The heart of the graphics subsystem is a modified version of AMD's ""super sixteen'' computer, called the graphics preprocessor computer (GPC). This computer is based on AMD's 2900 series of bit-slice components.

Carney, R. R.↗

Retrofitting avionics - Closing the performance 'Generation gap'

The retrofitting of advanced avionics to in-service aircraft in order to increase operational safety and flexibility, and reduce operating costs is analyzed. Research in flight management planning and airborne guidance for full-and cost-effective flight is examined. The use of CRTs and thin film electroluminescent displays in aircraft is described. The development of more accurate and reliable fuel gauges using nuclear-based techniques or volumetric measurements to evaluate fluid levels is studied. Advances in airspace systems, such as the Microwave Landing System, and Air Traffic Control Beacon System/Select Mode, the Traffic Advisory and Collision Advance System, and satellite-based communications, navigation, and surveillance are discussed.

Spitzer, C. R.↗

Design considerations for the beam-waveguide retrofit of a ground antenna station

Retrofitting an antenna that was originally designed without a beam waveguide introduces special difficulties because it is desirable to minimize alteration of the original mechanical truss work and to image the actual feed without distortion at the focal point of the dual-shaped reflector. To obtain an acceptable image, certain Geometrical Optics (GO) design criteria are followed as closely as possible. The problems associated with applying these design criteria to a 34-meter dual-shaped DSN (Deep Space Network) antenna are discussed. The use of various diffraction analysis techniques in the design process is also discussed. GTD and FFT algorithms are particularly necessary at the higher frequencies, while Physical Optics and Spherical Wave Expansions proved necessary at the lower frequencies.

Veruttipong, T.↗

Crew procedures and workload of retrofit concepts for microwave landing system

Crew procedures and workload for Microwave Landing Systems (MLS) that could be retrofitted into existing transport aircraft were evaluated. Two MLS receiver concepts were developed. One is capable of capturing a runway centerline and the other is capable of capturing a segmented approach path. Crew procedures were identified and crew task analyses were performed using each concept. Crew workload comparisons were made between the MLS concepts and an ILS baseline using a task-timeline workload model. Workload indexes were obtained for each scenario. The results showed that workload was comparable to the ILS baseline for the MLS centerline capture concept, but significantly higher for the segmented path capture concept.

Summers, Leland G.↗

Comprehensive helicopter rotor instrumentation - A retrofit approach using miniature transducers

This paper reports an approach used to retrofit a set of full-scale main rotor blades with 290 miniature pressure transducers, 46 strain gages, and 24 miniature accelerometers. Normally, in order to avoid disturbing the aerodynamics of the rotor flow field, the pressure instrumentation must be integrally built into the body of the rotor blades. However, using a method developed with NASA, miniature pressure transducers are mounted to the blade exterior surface without degrading the quality of the blade aerodynamics. Moreover, it is estimated that this approach reduced costs by more than 50 percent over building a set of pressure instrumented blades. The aerodynamic measurement objectives are presented as are instrumentation design considerations, type of instrumentation used, assembly process, and the installed instrumentation characteristics.

Jacklin, Stephen A.↗

Retrofitting a fine-pointing system to satellite optics

This paper describes a system added to an existing satellite-borne telescope design for the purpose of compensating the boresight errors that had been observed in earlier flights of similar instruments. Those errors had been found to be caused by thermal distortion of the spaceframe. This retrofit design was subjected to severe volume restrictions because it was fitted into an already tightly-packaged instrument envelope. It was found practical to improve the basic design by converting a redundant structure into a statically-determinate one. It was also possible to use portions of the mechanical actuation system to facilitate the position encoding needed for computer interfacing.

Woods, Robert O.↗

Retrofitting the AutoBayes Program Synthesis System with Concrete Syntax

AutoBayes is a fully automatic, schema-based program synthesis system for statistical data analysis applications. Its core component is a schema library. i.e., a collection of generic code templates with associated applicability constraints which are instantiated in a problem-specific way during synthesis. Currently, AutoBayes is implemented in Prolog; the schemas thus use abstract syntax (i.e., Prolog terms) to formulate the templates. However, the conceptual distance between this abstract representation and the concrete syntax of the generated programs makes the schemas hard to create and maintain. In this paper we describe how AutoBayes is retrofitted with concrete syntax. We show how it is integrated into Prolog and describe how the seamless interaction of concrete syntax fragments with AutoBayes's remaining legacy meta-programming kernel based on abstract syntax is achieved. We apply the approach to gradually mitigate individual schemas without forcing a disruptive migration of the entire system to a different First experiences show that a smooth migration can be achieved. Moreover, it can result in a considerable reduction of the code size and improved readability of the code. In particular, abstracting out fresh-variable generation and second-order term construction allows the formulation of larger continuous fragments.

Fischer, Bernd↗