Exploring the Meteorological Impacts of Surface and Rooftop Heat Mitigation Strategies Over a Tropical City

Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city-scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single-layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super-cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super-cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super-cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super-cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city-scale is urgent for sustainable urban planning.

54 ENVIRONMENTAL SCIENCES↗

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fire Resistance Development for UL 790 Burning Brand Test (CRADA Final Report)

Class A burning brand (UL 790) tests are used to determine the roof covering's effectiveness against severe exposure to external fire. Unfortunately, these tests can be costly to repeatedly perform when iteratively developing new materials/designs. The NREL team will work with the R&D Lab to develop and deploy computational tools to facilitate rapid development of roofing materials for the UL 790 standard test.

14 SOLAR ENERGY↗

Block Scale Rooftop Solar Technical Potential for the City of Orlando

The html maps are provided as supplementary information for the publication titled Parcel Scale Assessment of Rooftop Solar Technical Potential (NREL/PR-7A40-80780). The maps contain information on rooftop solar technical potential at the block scale for the city of Orlando in Florida. The rooftop solar technical potential information is based on data from two different datasets. The first dataset is LiDAR data for the city of Orlando obtained from the Orlando Utilities Commission (OUC) (Koebrich et al. 2021). The second dataset is a national parcel dataset (HIFLD 2020) which contains descriptive data and geometries for parcels in the U.S. Parcel scale data from both these datasets have been processed and aggregated to block scale to produce these html maps. The first html map (block scale developable roof area for Orlando) contains the developable roof area for solar. The second html map (block scale rooftop solar technical potential for Orlando) contains the rooftop solar technical potential in units of kilowatts as well as additional information on the most common building use type and the most common building occupancy type for the block. These html maps are provided to demonstrate the proof-of-concept analysis conducted for Orlando.

14 SOLAR ENERGY↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Evaluation of coal-associated sediments, wastes, and AMD sludge in the Southern Appalachian Basin as feedstock materials for REE and Li recovery

Critical minerals (CM) such as rare earth elements (REE+) and Lithium (Li) are essential to technological innovation, energy transitions, global economic and defense security, necessitating the search for unconventional resources and efficient recovery methods to avert supply chain disruptions. Here, this study evaluates coal-associated sediments (underclay and roof rock) and wastes from the Pennsylvanian Pottsville Formation of the Southern Appalachian Basin (SAB) as potential feedstocks for CM recovery. A total of 34 samples (15 underclays, 12 roof rocks, 5 Acid Mine Drainage (AMD) sludges, and 2 coal mining wastes) were characterized using XRD, XRF, ICP-MS, and μ-XRF analytical methods. The REE+ and Li concentrations of these materials ranged from 46.8 to 334.4 ppm and from 11.1 to 519 ppm, respectively, with one underclay sample (Hendrix 3456) yielding the highest values for both. Bulk mineralogy for all samples was dominated by aluminosilicate clay phases, particularly illite and kaolinite. All samples exhibited REY def, rel% values >26% and C outl indices that ranged from 0.69 to 0.94, classifying their REE ore potential as Category II (Promising) as defined by Seredin and Dai (2012). Extractability tests (EPA method 3051 A) yielded low REE+ and Li recoveries, with maximum values of 3.3% and 3.6%, respectively, suggesting associations with resistant minerals like clay and phosphates. Elemental mapping indicates that REE+ is associated with phosphate, whereas statistical analysis suggests that REE+ are associated with aluminosilicates, suggesting heterogeneous associations or minimal phosphate contribution. Li also correlated positively with Al 2 O 3 , indicating an aluminosilicate host. This study highlights the potential of coal-associated sediments in the SAB.

Clay minerals↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Temperature-adaptive radiative coating for all-season household thermal regulation

The sky is a natural heat sink that has been extensively used for passive radiative cooling of households. A lot of focus has been on maximizing the radiative cooling power of roof coating in the hot daytime using static, cooling-optimized material properties. However, the resultant overcooling in cold night or winter times exacerbates the heating cost, especially in climates where heating dominates energy consumption. In this work, we approached thermal regulation from an all-season perspective by developing a mechanically flexible coating that adapts its thermal emittance to different ambient temperatures. The fabricated temperature-adaptive radiative coating (TARC) optimally absorbs the solar energy and automatically switches thermal emittance from 0.20 for ambient temperatures lower than 15°C to 0.90 for temperatures above 30°C, driven by a photonically amplified metal-insulator transition. Simulations show that this system outperforms existing roof coatings for energy saving in most climates, especially those with substantial seasonal variations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White Earth Community Facilities Solar PV Project (Final Report)

Funded project was for the design, installation, and performance monitoring of 2 - 11.4 kW AC and 1-38.0 kW AC ground-mount solar installations for three tribal community facilities, for a total 60.8 kW AC, including a daycare facility and two community centers. Of in excess of 120 tribal buildings these facilities had showed the best promise for implementing solar, based upon site characteristics, roof loads, roof orientation and building size. The White Earth Nation seeks to move forward proactively to address the following project goals and objectives: 1) Reduction of energy costs, 2) Increasing energy security for Indian Tribes and tribal members, 3) Adding 60.8 KW in renewable energy generation (solar PV), 4) Offsets, reduces coal-fired electric energy demand by 76,397 kWh, 817,448 Source Energy Btu annually, and S) Meets the overall solar PV target set in the FOA.

14 SOLAR ENERGY↗

Low-Cost Preform and Molding Processes

The entry cost for prototyping a composite component for manufacture using automated, high rate processes is prohibitively expensive in many cases, especially for small business, where tooling costs may be several $100k. Discussions with industry also indicate that many small companies, tier 1 and 2 suppliers, have an interest to mold composite parts but do not want to deal with the capital cost, material handling issues, and labor associated with dry fiber preforming operations. While the molders may locate near the end user for logistics reasons, it may be more cost effective for the performer to remain regional and invest in capital equipment to support preform automation, thus keeping costs to a minimum. This project was designed to explore and demonstrate several options to meet these industry needs. Dry fiber preforming approaches were evaluated which allow for low pressure resin infusion, single sided tooling options such a vacuum assisted resin transfer molding (VARTM) or low pressure resin transfer molding (RTM-light). Unlike sheet molding compound, SMC compression molding where typical molding pressures of 1000 psi are required to push material into the desired location; positioning of a dry fiber preform into the desired location on the tool allows for low molding pressures of 10-50 psi. Lower molding pressures allow for use of low cost, additive fabrication of polymeric tooling. Polymeric tooling is suitable for rapid part prototyping and limited production. Dry fiber preforming approaches evaluated included use of commercial chopped strand mat, robotic chopper gun deposition, and continuous fiber preform augmentation using tailored fiber placement (TFP). Use of chopped strand mat does not require a robotic deposition method, however a cutting table is generally required and there is typically 20-30% scrap generation. While various fiber areal weights are available, the preform is not readily optimized for minimal fiber use or weight savings. In contrast, a robotic chopper gun approach allows for localized deposition where fiber is required to meet structural requirements. The robotic method is highly automated and minimizes fiber scrap, however the capital cost of the equipment and engineering labor for programming can result in higher preform cost compared to chopped strand mat in certain cases depending on preform complexity. Dry fiber preforming using the robotic chopper gun method allows for creation of three dimensional forms. This approach may be ideal for molding in-house, or if the preforms stack together densely to allow for efficient shipping. Applications evaluated for this program considered trade-off between fabrication of a fully 3D preform versus production of a flat preform which is designed to readily drape into the final desired shape. Such a preform design greatly simplifies robotic programming and requires no specialized tooling. The flat preforms are easily stacked and shipped to the final molding location. Flat preforms are much easier to augment with TFP continuous fiber to provide local reinforcement. The demonstration and evaluation of these preforming and tooling methods were completed on three component applications. The first application was a battery box cover for an electric vehicle which was highly three dimensional. The second demonstrator article was comprised of complex contours and was used to demonstrate the use of TFP and RTM-light molding process. The third demonstration article was the roof of an operator’s cab for large construction equipment. The roof is relatively flat however it is comprised of complex changes in thickness which clearly demonstrate the advantage of robotic chopper gun approach as compared to using numerous preform layers of chopped strand mat. The cost trades for the various preforming methods are summarized to help guide the reader as to preforming method considerations. Finally, these demonstrations all used glass fiber roving. A fourth, exploratory task was added to evaluate the ability to make preforms using Zoltek’s carbon fiber split tow roving. We were able to adapt the chopper gun to make flat preforms for laminate testing, but further development effort would be required to make suitable preforms.

36 MATERIALS SCIENCE↗

Analysis of Photovoltaic Energy: CRADA Number CRD-21-17862 (Cooperative Research and Development Final Report)

For this project, NREL will work with the Participant to model phase change material performance, model photovoltaic thermodynamics performance, and predict photovoltaic module durability based on environmental conditions to help develop optimized photovoltaic roofing designs. This project will develop thermodynamic models of integrated photovoltaic roofing with phase change materials. These models will be used to optimize the materials and design selections based on reducing photovoltaic operating temperatures while balancing cost effective integration of phase change materials.

14 SOLAR ENERGY↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NARAC Meteorological Monitoring Tower Maintenance Report: Submarine Base Group Two, Sub Base New London NEWLBASE2 Tower

Comments: The roof-based tower is located on Building 17 on Naval Submarine Base New London. Tower installation date is unknown. A second GFCI outlet in-line with the standard GFCI in the logger enclosure is mounted on conduit out of the tower base pedestal. The roof surface has been replaced and is now safe to walk on. The tower was not climbed during this maintenance visit. After the maintenance visit in 2018, the tower was deemed unsafe to climb due to age, corrosion, and deterioration of the tower components. The wind, air temperature, and relative humidity sensors located on the upper part of the tower require climbing of the tower for servicing and could not be accessed for inspection and maintenance. The tower is scheduled for replacement in FY2023. Tasks to be Completed: Tower system replacement / relocation. Consider replacement or bypassing of the suspect precipitation gauge signal connector.

99 GENERAL AND MISCELLANEOUS↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States, 2024 Edition [Slides]

Berkeley Lab’s annual Tracking the Sun report describes trends among grid-connected, distributed solar photovoltaic (PV) and paired PV+storage systems in the United States. For the purpose of this report, distributed solar includes residential systems, roof-mounted non-residential systems, and ground-mounted systems up to 5 MW-AC. Ground-mounted systems larger than 5 MW-AC are covered in Berkeley Lab’s companion annual report, Utility-Scale Solar. The latest edition of the report is based on 3.7 million systems installed through year-end 2023, representing close to 80% of systems installed to date. The report describes and discusses key trends related to: -Project characteristics, including system size, module efficiencies, roof-coverage ratios, prevalence of paired PV with storage, use of module-level power electronics, third-party ownership, mounting configurations, panel orientation, and customer segmentation -Median installed-price trends, both nationally and by state -Variability in pricing according to system size, state, installer, equipment type, and other factors, relying on both descriptive analysis and a multi-variate regression to estimate the effects of key pricing drivers for residential systems installed in 2023.

14 SOLAR ENERGY↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Panel Installation at Goucher College

As part of our multi-phased sustainability initiative, Goucher College is implementing a series of necessary changes to become a model “green” campus. This comprehensive approach includes implementing systems designed to reduce energy consumption, water usage, and waste production by 2030. The first phase of this holistic endeavor is to develop two independent solar projects. One will be on the Facility Management Services building (FMS) and the other will be on the Central Utility Plan (CUP). The anticipated duration of this project is expected to be 24 months. When completed, the new photovoltaic panels (PVPs) and resulting solar array system will help offset campus energy consumption. The projects will also help the College achieve its goal of working towards operating primarily on renewable energy. During initial review of the project, it was revealed replacing the roofs prior to installing new PVPs would not only provide a sound structural foundation for the projects, but the new roofing systems will also aid de-carbonization. The project’s scope is divided between two buildings. Building A: FMS is the first building and Building B: CUP is the second building.

14 SOLAR ENERGY↗

Effect of Urban Heat Island and Global Warming Countermeasures on Heat Release and Carbon Dioxide Emissions from a Detached House

Urban air temperature rises induced by the urban heat island (UHIE) effect or by global warming (GW) can be beneficial in winter but detrimental in summer. The SCIENCE-Outdoor model was used to simulate changes to sensible heat release and CO 2 emissions from buildings yielded by four UHIE countermeasures and five GW countermeasures. This model can evaluate the thermal condition of building envelope surfaces, both inside and outside. The results showed that water-consuming UHIE countermeasures such as evaporative space cooling and roof water showering provided positive effects (decreasing sensible heat release and CO 2 emissions related to space conditioning) in summer. Additionally, they had no negative (unwanted cooling) effects in winter since they can be turned off in the heating season. Roof greening can provide the greatest space- conditioning CO 2 emissions reductions among four UHIE countermeasures, and it reduces the amount of heat release slightly in the heating season. Since the effect on reducing carbon dioxide (CO 2 ) emissions by UHIE countermeasures is not very significant, it is desirable to introduce GW countermeasures in order to reduce CO 2 emissions. The significance of this study is that it constructed the new simulation model SCIENCE-Outdoor and applied it to show the influence of countermeasures upon both heat release and CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗