Search NASA⌕ Search

SEARCH · Search NASA

Results for “Room Return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Importance of Contamination Knowledge - Insights into Mars Sample Return

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC), in Houston, TX (henceforth Curation Office) manages the curation of all past, present, and future extraterrestrial samples returned by NASA missions and shared collections from international partners, preserving their integrity for future scientific study while providing the samples to the international community in a fair and unbiased way. The Curation Office also curates all reference and witness materials for each mission (e.g., flight and non-flight hardware coupons; lubricants; non-flight, flight-like, and flown witness plates). These reference and witness materials provide the scientific community with the fundamental ability to reconstruct the contamination/alteration history of the sample collection through the course of the mission, with the overall goal of strengthening the scientific conclusions drawn from the study of returned materials. The information gained from characterizing the physical, biological, inorganic, and organic chemical properties of reference and witness materials is defined as the Contamination Knowledge (CK) of the sample collection. Unlike the data collected for Contamination Control (CC) and Planetary Protection (PP), CK is exclusively concerned with preserving reference and witness materials for study by future scientists upon sample return. Although CC and PP data collected for sample integrity and forward contamination purposes can be complementary to CK, they are two separate data sets with distinct objectives. A robust collection of samples for CK is necessary to allow the extraterrestrial material in a returned sample to be distinguished from terrestrial contamination. Traditionally CK is utilized by sample scientists in order to accomplish the mission’s scientific objectives, however this information can also be utilized by the Office of Planetary Protection to help evaluate the presence of any back contamination. Mars 2020, the first phase of a potential multipart Mars Sample Return (MSR) campaign, is expected to contribute to NASA’s Mars Exploration Program Science Goals by filling in knowledge gaps concerning: 1) the existence of past or present life on Mars, 2) the past and present climate of Mars, 3) the geology of Mars, and 4) hazards associated with human exploration of Mars. Although there is debate concerning which samples will best answer these questions, the necessity for proper sample blanks is well-understood. The CC and PP requirements, driven by the restricted Class V mission designation, are the most stringent of any sample return mission in recent history. The extremely low levels of allowable terrestrial contamination on the spacecraft and rover can complicate these analyses given the detection limits of current analytical instrumentation, especially in the case of biological contamination. By collecting and curating unanalyzed samples specifically for CK, future sample scientists will not be relegated to: 1) relying on data collected using possibly obsolete tools and techniques for return sample blanks, or 2) using remnants of extracted and/or cultured samples from ATLO (Assembly, Test, and Launch Operations), which could be incompatible with the desired experimental endpoints or state-of-the-art techniques available at the time of sample return.The addition of biological experimental endpoints to a sample return campaign’s objectives broadens the requisite range in preservation environments (e.g. inert ultra-pure nitrogen gaseous environment at 18 degrees Centigrade versus less than or equal to minus 80 degrees Centigrade) and types of CK samples. As a result, the Curation Office will also curate the following CK samples at less than or equal to minus 80 degrees Centigrade for the Mars 2020 mission: 1) unanalyzed swabs and wipes in sterile containers, 2) all recirculation filters from the clean rooms used for sample and caching subsystem assembly and all filters from the laminar flow benches used to assemble sample intimate hardware, and 3) witness plates collecting airborne contamination within the assembly clean rooms. It has been Curation Office policy since the Apollo missions to preserve as many pristine samples as possible for future scientific research. Although CK is required to be collected for all stages of the MSR campaign, the CK for the Mars 2020 mission is the most critical for understanding contamination in the returned samples given the intimacy between the Martian samples and the Mars 2020 flight hardware. This presentation highlights the importance of CK for sample return missions as well as the traditional and novel types of CK samples required for a successful MSR campaign.

Harrington, A. D.↗

Checking Contamination during Storage of Carbonaceous Chondrites for Micro FTIR Measurements

We examined organic contamination by Fourier transform infrared micro spectroscopic (micro FTIR) measurements of carbonaceous chondrite samples. Carbonaceous chondrites, Tagish Lake (C2), Murchison (CM2) and Moss (CO3), and some mineral powder samples pressed on aluminum plates were measured by micro FTIR before and after storage in several containers with silicone rubber mat. During storage, samples did not touch directly anything except the holding aluminum plates. The carbonaceous chondrites containing hydrous minerals (Tagish Lake and Murchison) pressed on aluminum plates and measured by transmission-reflection micro FTIR measurements were found to be contaminated during storage after only one day, as revealed by an increase of approximately 2965 /cm and approximately 1260 /cm peaks. The Moss meteorite which contains no hydrous minerals, did not show an increase of these peaks, indicating no organic contamination. This difference is probably related to the differing mineralogy and physical properties (including porosity and permeability) of these chondrites. Hydrous minerals such as antigorite, muscovite, montmorillonite and silica gel showed organic contamination by the same infrared measurements, while anhydrous materials such as SiO2 and KBr showed no contamination. These results indicate importance of surface OH groups for the organic contamination. Organic contamination was found on silica gel samples pressed on aluminum plates when they were stored within containers including silicone rubber, silicone grease or adhesive tape. Long path gas cell FTIR measurements for silicone rubber indicated methylsiloxane oligomers were released from the silicone rubber. In-situ heating infrared measurements on the contaminated antigorite and Tagish Lake showed decrease of the 1262 /cm (Si-CH3) and 2963 /cm (CH3) peaks from room temperature to 200-300 C indicating desorption of volatile contaminants. These results indicate that careful preparation and storage are essential for FTIR measurements on precious astromaterial samples such as meteorites, IDPs and samples returned from comets, asteroids and Mars. Every possible contamination source should be evaluated before anything is done to these samples.

Zolensky, Michael E.↗

Correlation of Electric Field and Critical Design Parameters for Ferroelectric Tunable Microwave Filters

The correlation of electric field and critical design parameters such as the insertion loss, frequency ability return loss, and bandwidth of conductor/ferroelectric/dielectric microstrip tunable K-band microwave filters is discussed in this work. This work is based primarily on barium strontium titanate (BSTO) ferroelectric thin film based tunable microstrip filters for room temperature applications. Two new parameters which we believe will simplify the evaluation of ferroelectric thin films for tunable microwave filters, are defined. The first of these, called the sensitivity parameter, is defined as the incremental change in center frequency with incremental change in maximum applied electric field (EPEAK) in the filter. The other, the loss parameter, is defined as the incremental or decremental change in insertion loss of the filter with incremental change in maximum applied electric field. At room temperature, the Au/BSTO/LAO microstrip filters exhibited a sensitivity parameter value between 15 and 5 MHz/cm/kV. The loss parameter varied for different bias configurations used for electrically tuning the filter. The loss parameter varied from 0.05 to 0.01 dB/cm/kV at room temperature.

Subramanyam, Guru↗

Vestibular factors influencing the biomedical support of humans in space

This paper will describe the biomedical support aspects of humans in space with respect to the vestibular system. The vestibular system is thought to be the primary sensory system involved in the short-term effects of space motion sickness although there is increasing evidence that many factors play a role in this complex set of symptoms. There is the possibility that an individual's inner sense of orientation may be strongly coupled with the susceptibility to space motion sickness. A variety of suggested countermeasures for space motion sickness will be described. Although there are no known ground-based tests that can predict space motion sickness, the search should go on. The long term effects of the vestibular system in weightlessness are still relatively unknown. Some preliminary data has shown that the otoconia are irregular in size and distribution following extended periods of weightlessness. The ramifications of this data are not yet known and because the data was obtained on lower order animals, definitive studies and results must wait until the space station era when higher primates can be studied for long durations. This leads us to artificial gravity, the last topic of this paper. The vestibular system is intimately tied to this question since it has been shown on Earth that exposure to a slow rotating room causes motion sickness for some period of time before adaptation occurs. If the artificial gravity is intermittent, will this mean that people will get sick every time they experience it? The data from many astronauts returning to Earth indicates that a variety of sensory illusions are present, especially immediately upon return to a 1-g environment. Oscillopsia or apparent motion of the visual surround upon head motion along with inappropriate eye motions for a given head motion, all indicate that there is much to be studied yet about the vestibular and CNS systems reaction to a sudden application of a steady state acceleration field like 1-g. From the above information it is obvious that the vestibular system does have unique requirements when it comes to the biomedical support of space flight. This is not to say that other areas such as cardiovascular, musculo-skeletal, immunological and hematological systems do not have their own unique requirements but that possible solutions to one system can provide continuing problems to another system. For example, artificial gravity might be helpful for long term stabilization of bone demineralization or cardiovascular deconditioning but might introduce a new set of problems in orientation, vestibular conflict and just plain body motion in a rotating space vehicle.

Non-NASA Center↗

GeoLab: A Geological Workstation for Future Missions

The GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance theThe GeoLab glovebox was, until November 2012, fully integrated into NASA's Deep Space Habitat (DSH) Analog Testbed. The conceptual design for GeoLab came from several sources, including current research instruments (Microgravity Science Glovebox) used on the International Space Station, existing Astromaterials Curation Laboratory hardware and clean room procedures, and mission scenarios developed for earlier programs. GeoLab allowed NASA scientists to test science operations related to contained sample examination during simulated exploration missions. The team demonstrated science operations that enhance the early scientific returns from future missions and ensure that the best samples are selected for Earth return. The facility was also designed to foster the development of instrument technology. Since 2009, when GeoLab design and construction began, the GeoLab team [a group of scientists from the Astromaterials Acquisition and Curation Office within the Astromaterials Research and Exploration Science (ARES) Directorate at JSC] has progressively developed and reconfigured the GeoLab hardware and software interfaces and developed test objectives, which were to 1) determine requirements and strategies for sample handling and prioritization for geological operations on other planetary surfaces, 2) assess the scientific contribution of selective in-situ sample characterization for mission planning, operations, and sample prioritization, 3) evaluate analytical instruments and tools for providing efficient and meaningful data in advance of sample return and 4) identify science operations that leverage human presence with robotic tools. In the first year of tests (2010), GeoLab examined basic glovebox operations performed by one and two crewmembers and science operations performed by a remote science team. The 2010 tests also examined the efficacy of basic sample characterization [descriptions, microscopic imagery, X-ray fluorescence (XRF) analyses] and feedback to the science team. In year 2 (2011), the GeoLab team tested enhanced software and interfaces for the crew and science team (including Web-based and mobile device displays) and demonstrated laboratory configurability with a new diagnostic instrument (the Multispectral Microscopic Imager from the JPL and Arizona State University). In year 3 (2012), the GeoLab team installed and tested a robotic sample manipulator and evaluated robotic-human interfaces for science operations.

Evans, Cynthia↗

Temperature effects on high strain rate properties of graphite/epoxy composites

A unidirectional graphite epoxy material (AS4/3501-6) was characterized at strain rates ranging from 5 x 10(exp 6) s(exp -1) to 5(exp -1), at room temperature and at 128 C. Results are presented in the form of stress-strain curves to failure. The longitudinal properties remain nearly unchanged with strain rate and temperature. The transverse modulus increases with strain rate but decreases with temperature. The transverse strength and transverse ultimate tensile strain have a positive rate sensitivity at low rates, which changes to negative at intermediate rates and returns to positive rate sensitivity at the highest rates tested. A temperature-time equivalence principle was applied and master curves were obtained for the transverse mechanical properties. The in-plane shear modulus and in-plane shear strength have a positive rate sensitivity. The ultimate intralaminar shear strain has a positive rate sensitivity at low rates, which changes to negative at high rates. At the elevated temperature of 128 C, the ultimate shear strain is 25 to 30 percent higher than the room temperature value, but its strain rate dependence is moderate.

Yaniv, G.↗

A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

Mejia, M.↗

OSIRIS-REx: Curating Samples from the Carbon rich Asteroid Bennu

The OSIRIS REx mission returned 121 g of pristine material from the asteroid Bennu. This talk will describe the how the sample was collected, returned to earth, retrieved, and how it is currently being curated at the NASA Johnson Space Center. In order to keep the samples pristine they are kept under an ultra pure nitrogen atomosphere inside and ISO 5 equivalent clean room. Special care is taken not to expose the samples to oxygen, or organic contaminants. NASA has implemented additional procedures to minimize the likelihood of biological contamination. The presentation will also include a brief description of the preliminary results from initial study of the samples.

Aaron B. Regberg↗

Noble Gases in Samples Returned From Asteroids Ryugu and Bennu

Introduction: The asteroid sample return missions, JAXA’s Hayabusa2 [1] and NASA’s OSIRIS-REx [2], fromC-rich asteroids Ryugu and Bennu offer unique opportunities to sample pristine early solar system material, unaffected by terrestrial weathering and contamination, and with a known geological context. The comparison with most primi-tive members of carbonaceous –and inner solar system ordinary and enstatite– chondrite classes allows us to (i) assess the variation (or the lack of thereof) of the distribution of the most volatile elements throughout the entire early solar system, (ii) determine the effects of parent body thermal and aqueous alteration, and (iii) learn about the dynamic evolution and history of the various parent bodies, as sampled by both return missions and meteorite delivery. Here we will present noble gas data obtained from newly received particles from Ryugu and Bennu. Samples & Analysis: We received nine particles allocated by JAXA, with masses of 0.5-1.7 mg mass: four col-lected during Hayabusa2’s first touchdown (chamber A) and five from a small artificial crater (chamber C). We received three particles from Bennu of 0.07, 0.89 and 0.94 mg mass (OREX-800032-102/3/4). All particles were processed, allocated, weighed, and transferred into our UHV sample chamber within pure N2, to prevent any contact with air. We examined all He-Xe isotopes with our custom-built mass spectrometer “Albatros” ([3,4]). Gases were extracted individually from each particle by melting induced by a 1064 μm Nd:YAG IR laser in 2–4 heating steps. Large amounts of water and other reactive volatiles were released, consistent with the presence of abundant volatiles from both Ryugu and Bennu. Residues of Ryugu particles remaining after lasering, subsequently exposed to air, were additionally extracted in a crucible to verify complete gas extraction. Only the particle that still showed a “crystalline” structure after lasering contained detectable Ryugu noble gases, whereas all other particles turned immediately into glassy spheres by laser heating and lacked any gas. Results & Discussion: Ryugu and Bennu matter contains noble gases similar to the most pristine, unheated aqueously altered meteorites, e.g., CM or CI chondrites [5,6]. Remarkably, all four chamber A samples that originated from Ryugu’s surface show solar wind (SW) Ne (trapped (20Ne/22Ne)tr ~12–13), whereas all five chamber C samples do not ((20Ne/22Ne)tr ~9.0–10.7 consistent with the presence of non-solar trapped Ne components such as Q and HL). This demonstrates that JAXA’s sampling strategy succeeded: Chamber C samples analyzed in this work originated from areas shielded from SW, slightly below the surface, that was sampled after the impactor excavated material. The three Bennu particles populate the same range as the Ryugu particles in Ne isotope space with one particle containing SW suggesting that it was part of the uppermost surface layer of Bennu during sampling, while Ne in the smallest sample can be explained best by mixing Ne from presolar diamonds and SiC or graphite, and that in the third one by mixing of, e.g., Q and HL. Using cosmic ray production rates given by [7] yields preliminary exposure ages for Ryugu particles in the same range as determined in [7]. There is, as expected, also no systematic difference between samples from chambers A and C because both sample sets were likely collected within the uppermost layer of Ryugu, which were not shielded from cosmic rays. The concentration of cosmogenic (cos) Ne in the Bennu particle, where Necos was resolvable, is in the same range as found for Ryugu, suggesting roughly similar exposure time to cosmic rays for 5–8 Ma for all particles examined here. The Xe isotopic compositions of all particles are consistent with those of phase Q, with small additions of Xe-HL from presolar diamonds and excess 129Xe* from short-lived 129I decay. The comparably high 129Xe*/129XeQ ratio is similar in all samples, suggesting similar initial I concentrations and closure to Xe loss –or the incorporation of a well-mixed Xe reservoir. The Bennu material was in brief contact with air in the capsule, after atmospheric entry and before storage in pure N2 in a clean room. Both, the –most diagnostic– Xe isotopes and the Ar/Xe vs. Kr/Xe systematics prove that the noble gases are not affected by terrestrial contamination, in contrast to many CI, CY, and CM chondrites found on Earth [5,6], illustrating the importance of sample return. He-Xe concentrations in all particles unaffected bySW are comparable to but at the upper end of ranges reported [5-7]. In accordance with the strong aqueous alteration experienced on the parent bodies of Ryugu and Bennu [1,2], all samples lack the Ar-rich and water-susceptible noble gas components found in less aqueously altered CMs or CRs [e.g., 5,8] and all COs.

Henner Busemann↗

Solar wind and terrestrial atmosphere effects on lunar sample surface composition

Samples returned from the Apollo missions have been shown to have undergone a partial surface oxidation with the degree of oxidation being dependent on the intensity and duration of exposure to a terrestrial or other oxidizing atmosphere. Exposure to atomic hydrogen at room temperature, or molecular hydrogen above 100 C results in a surface reduction. The adsorption of water vapor on a test sample was found to be only slightly dependent on the state of surface oxidation, a situation consistent with the formation of hydroxyl groups on the surface when a sample is exposed to hydrogen. That hydroxyl groups are indeed formed is substantiated by the release of water vapor (and by release of heavy water following exposure to deuterium), indicating that water vapor can be synthesized from solar wind hydrogen and sample oxygen. Observations of trace amounts of methane indicate that the reduction process is by no means restricted to the formation of water vapor.

Cadenhead, D. A.↗

Re-Engineering the ISS Payload Operations Control Center During Increased Utilization and Critical Onboard Events

With an increase in the utilization and hours of payload operations being executed onboard the International Space Station (ISS), upgrading the NASA Marshall Space Flight Center (MSFC) Huntsville Operations Support Center (HOSC) ISS Payload Control Area (PCA) was essential to gaining efficiencies and assurance of current and future payload health and science return. PCA houses the Payload Operations Integration Center (POIC) responsible for the execution of all NASA payloads onboard the ISS. POIC Flight Controllers are responsible for the operation of voice, stowage, command, telemetry, video, power, thermal, and environmental control in support of ISS science experiments. The methodologies and execution of the PCA refurbishment were planned and performed within a four month period in order to assure uninterrupted operation of ISS payloads and minimal impacts to payload operations teams. To vacate the PCA, three additional HOSC control rooms were reconfigured to handle ISS realtime operations, Backup Control Center (BCC) to Mission Control in Houston, simulations, and testing functions. This involved coordination and cooperation from teams of ISS operations controllers, multiple engineering and design disciplines, management, and construction companies performing an array of activities simultaneously and in sync delivering a final product with no issues that impacted the schedule. For each console operator discipline, studies of Information Technology (IT) tools and equipment layouts, ergonomics, and lines of sight were performed. Infusing some of the latest IT into the project was an essential goal in ensuring future growth and success of the ISS payload science returns. Engineering evaluations led to a state of the art media wall implementation and more efficient ethernet cabling distribution providing the latest products and the best solution for the POIC. These engineering innovations led to cost savings for the project. Constraints involved in the management of the project included executing over 450 crew-hours of ISS real-time payload operations including a major onboard communications upgrade, SpaceX un-berth, a Soyuz launch, roll-out of ISS live video and interviews from the POIC, annual BCC certification and hurricane season, and ISS simulations and testing. Continuous ISS payload operations were possible during the PCA facility modifications with the reconfiguration of four control rooms and standup of two temporary control areas. Another major restriction to the project was an ongoing facility upgrade that included a NASA Headquarters mandated replacement of all electrical and mechanical systems and replacement of an external generator. These upgrades required a facility power outage during the PCA upgrades. The project also encompassed console layout designs and ordering, amenities selections and ordering, excessing of old equipment, moves, disposal of old IT equipment, camera installations, facility tour re-schedules, and contract justifications. These were just some of the tasks needed for a successful project.

Marsh, Angela L.↗

Re-Engineering the ISS Payload Operations Control Center During Increased Utilization and Critical Onboard Events

With an increase in utilization and hours of payload operations being executed onboard the International Space Station (ISS), upgrading the NASA Marshall Space Flight Center (MSFC) Huntsville Operations Support Center (HOSC) ISS Payload Control Area (PCA) was essential to gaining efficiencies and assurance of current and future payload health and science return. PCA houses the Payload Operations Integration Center (POIC) responsible for the execution of all NASA payloads onboard the ISS. POIC Flight Controllers are responsible for the operation of voice, stowage, command, telemetry, video, power, thermal, and environmental control in support of ISS science experiments. The methodologies and execution of the PCA refurbishment were planned and performed within a four-month period in order to assure uninterrupted operation of ISS payloads and minimal impacts to payload operations teams. To vacate the PCA, three additional HOSC control rooms were reconfigured to handle ISS real-time operations, Backup Control Center (BCC) to Mission Control in Houston, simulations, and testing functions. This involved coordination and cooperation from teams of ISS operations controllers, multiple engineering and design disciplines, management, and construction companies performing an array of activities simultaneously and in sync delivering a final product with no issues that impacted the schedule. For each console operator discipline, studies of Information Technology (IT) tools and equipment layouts, ergonomics, and lines of sight were performed. Infusing some of the latest IT into the project was an essential goal in ensuring future growth and success of the ISS payload science returns. Engineering evaluations led to a state of the art Video Wall implementation and more efficient ethernet cabling distribution providing the latest products and the best solution for the POIC. These engineering innovations led to cost savings for the project. Constraints involved in the management of the project included executing over 450 crew-hours of ISS real-time payload operations including a major onboard communications upgrade, SpaceX un-berth, a Soyuz launch, roll-out of ISS live video and interviews from the POIC, annual BCC certification and hurricane season, and ISS simulations and testing. Continuous ISS payload operations were possible during the PCA facility modifications with the reconfiguration of four control rooms and standup of two temporary control areas. Another major restriction to the project was an ongoing facility upgrade that included a NASA Headquarters mandated replacement of all electrical and mechanical systems and replacement of an external generator. These upgrades required a facility power outage during the PCA upgrades. The project also encompassed console layout designs and ordering, amenities selections and ordering, excessing of old equipment, moves, disposal of old IT equipment, camera installations, facility tour re-schedules, and contract justifications. These were just some of the tasks needed for a successful project. This paper describes the logistics and lessons learned in upgrading a control center capability in the middle of complex real-time operations. Combining the efficiencies of controller interaction and new technology infusion were prime drivers for this upgrade to handle the increased utilization of science research on ISS. The success of this project could not jeopardize the current operations while these facility upgrades occurred.

Dudley, Stephanie R. B.↗

Clean is not Sterile: A Planetary Science and Planetary Protection Perspective on Cleanroom Microbiology at NASA

The Astromaterials Acquisition and Curation Office at NASA is responsible for the curation of extraterrestrial samples from NASA’s past and future sample return missions. Our office curates samples from the moon, meteorites, comets, asteroids, cosmic dust and solar wind particles. All these samples are kept in cleanrooms to limit particulate and trace metal contamination, but none of these cleanrooms are specifically designed to control microbial contamination. During the early Apollo missions NASA scientists were very concerned with protecting the Earth from potential microbial contamination from the moon and with protecting the lunar samples from terrestrial microbes. NASA developed specialized equipment and clean rooms to keep these collections pristine. However, as we learned more about the lunar environment our concerns about microbial contamination lessened. Today none of the existing collections have microbial contamination requirements because they are not considered susceptible to microbial alteration under curation conditions (e.g. solar wind samples, and lunar samples) or have already been contaminated by terrestrial biology (meteorites collected in Antarctica). However, NASA’s OSIRIS-REx mission will land in 2023 with samples from a carbon rich asteroid that will be susceptible to microbial alteration. The Perseverance rover on Mars will begin to collect and cache samples that will be returned to Earth as soon as 2031. Martian samples may contain signs of extraterrestrial life and will have to be treated like the early Apollo samples. Martian samples will be isolated to protect the Earth, and must also be protected from terrestrial contamination. I will present microbial monitoring data from existing NASA cleanrooms and discuss how NASA is planning to use techniques from the pharmaceutical industry and academia to design new laboratories and equipment that will protect astromaterials and the earth from unwanted microbial contamination. I will also discuss a project to sample the external microbiome of the International Space Station. Results from this research will be used to design facilities for use on Mars that limit the amount of contamination associated with crewed missions.

Aaron B Regberg↗

Effects of hindlimb unloading on neuromuscular development of neonatal rats

We hypothesized that hindlimb suspension unloading of 8-day-old neonatal rats would disrupt the normal development of muscle fiber types and the motor innervation of the antigravity (weightbearing) soleus muscles but not extensor digitorum longus (EDL) muscles. Five rats were suspended 4.5 h and returned 1.5 h to the dam for nursing on a 24 h cycle for 9 days. To control for isolation from the dam, the remaining five littermates were removed on the same schedule but not suspended. Another litter of 10 rats housed in the same room provided a vivarium control. Fibers were typed by myofibrillar ATPase histochemistry and immunostaining for embryonic, slow, fast IIA and fast IIB isomyosins. The percentage of multiple innervation and the complexity of singly-innervated motor terminal endings were assessed in silver/cholinesterase stained sections. Unique to the soleus, unloading accelerated production of fast IIA myosin, delayed expression of slow myosin and retarded increases in standardized muscle weight and fiber size. Loss of multiple innervation was not delayed. However, fewer than normal motor nerve endings achieved complexity. Suspended rats continued unloaded hindlimb movements. These findings suggest that motor neurons resolve multiple innervation through nerve impulse activity, whereas the postsynaptic element (muscle fiber) controls endplate size, which regulates motor terminal arborization. Unexpectedly, in the EDL of unloaded rats, transition from embryonic to fast myosin expression was retarded. Suspension-related foot drop, which stretches and chronically loads EDL, may have prevented fast fiber differentiation. These results demonstrate that neuromuscular development of both weightbearing and non-weightbearing muscles in rats is dependent upon and modulated by hindlimb loading.

Non-NASA Center↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

Zeigler, R. A.↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

Zeigler, R. A.↗

Demonstration of Oxygen and Carbon Monoxide Propellants for Mars Missions

Currently, proposed planetary exploration missions must be small, with low costs and a short development time. Relatively high-risk technologies are being accepted for such missions if they meet these guidelines. For a Mars sample-return mission, one of the higher risk technologies is the use of return propellants produced from indigenous materials such as the Martian atmosphere. This consists of 96 percent carbon dioxide, which can be processed into oxygen and carbon monoxide. This year, the NASA Lewis Research Center completed the experimental evaluation and subscale technology development of an oxygen/carbon monoxide propellant combination. Previous research included ignition characterization, combustion performance, and heat transfer characterization with gaseous propellants at room temperature. In this year s tests, we studied the ignition characteristics and combustion of oxygen and carbon monoxide at near liquid temperatures. The mixture ratio boundaries for oxygen and carbon monoxide were determined as a function of propellant temperature in a spark torch igniter. With both propellants at room temperature, the ignition range was between 0.50 and 1.44; and with both propellants chilled to near-liquid temperatures, it was between 2.4 and 3.1. Statistical analysis of the mean value of the ignition boundaries provided models that describe the combination of oxygen temperature, carbon monoxide temperature, and mixture ratio that resulted in ignition. This range is the larger boxed area shown in the figure. The smaller boxed area indicates the range at which there is a 90-percent confidence that ignition will occur. The relatively small range at only 90-percent confidence indicates that using the oxygen/carbon monoxide combination as its own ignition source may not be the best design for a remote engine operating on Mars. Tests also were performed in a simulated small rocket engine that used oxygen/hydrogen combustion gases as the ignition source for oxygen/carbon monoxide. In these experiments, the oxygen/carbon monoxide was successfully ignited in eight of eight tests at a mixture ratio of 0.52. In addition, the oxygen/carbon monoxide maintained steady combustion after the oxygen/hydrogen ignition source was removed, verifying that the oxygen/carbon monoxide rocket engine should continue to be included in mission plans as return propulsion from Mars.

Linne, Diane L.↗

Fluid inclusions in Martian samples: Clues to early crustal development and the hydrosphere

Major questions about Mars that could be illuminated by examining fluid inclusions in Martian samples include: (1) the nature, extent and timing of development (and decline) of the hydrosphere that existed on the planet; and (2) the evolution of the crust. Fluid inclusion analyses of appropriate samples could provide critical data to use in comparison with data derived from analogous terrestrial studies. For this study, sample handling and return restrictions are unlikely to be as restrictive as the needs of other investigators. The main constraint is that the samples not be subjected to excessively high temperatures. An aqueous fluid inclusion trapped at elevated pressure and temperature will commonly consist of liquid water and water vapor at room temperature. Heating (such as is done in the laboratory to fix P-V-T data for the inclusion) results in moderate pressure increases up to the liquid-vapor homogenization temperature followed by a sharp increase in pressure with continued heating because the inclusion is effectively a fixed volume system. This increased pressure can rupture the inclusion; precise limits are dependent on size, shape, and composition as well as the host material.

Brown, Philip E.↗