Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Three-Wheel Brush-Wheel Sampler

A new sampler is similar to a common snow blower, but is robust and effective in sample collection. The brush wheels are arranged in a triangle shape, each driven by a brushless DC motor and planetary gearhead embedded in the wheel shaft. Its speed can be varied from 800 - 2,000 rpm, depending on the surface regolith resistance. The sample-collecting flow path, and internal features, are designed based on flow dynamics, and the sample-collecting rates have consistently exceeded the requirement under various conditions that span the range of expected surface properties. The brush-wheel sampler (BWS) is designed so that the flow channel is the main body of the apparatus, and links the brush-wheel assembly to the sample canister. The combination of the three brush wheels, the sample flow path, and the canister location make sample collection, storage, and transfer an easier task.

Duckworth, Geoffrey A.↗

Biblade Sampler

A BiBlade sampler may include a first blade and a second blade in a retracted position. The BiBlade sampler may also include a gripper, which is driven by an actuator. The gripper may include a plurality of fingers to force the first blade and the second blade to remain in a retracted position. When the fingers are unhooked, the first blade and the second blade penetrate a surface of an object.

Backes, Paul G.↗

Microbial Air Sampler Payload - Astrobee

The following package 2020-09-28 Microbial Air Sampler folders consist of a prototype design of a microbial air sample payload to fit in the bays of Astrobee free-flyer. There are several CAD designs prototypes and documentation about the concept and the current air sampler device.

Jose Cortez↗

Determination of Critical Experiment Correlations Using the Sampler Sequence Within SCALE 6.2

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique.

42 ENGINEERING↗

A Gel Probe Equilibrium Sampler for Measuring Arsenic Porewater Profiles And Sorption Gradients in Sediments: I. Laboratory Development

A gel probe equilibrium sampler has been developed to study arsenic (As) geochemistry and sorption behavior in sediment porewater. The gels consist of a hydrated polyacrylamide polymer, which has a 92% water content. Two types of gels were used in this study. Undoped (clear) gels were used to measure concentrations of As and other elements in sediment porewater. The polyacrylamide gel was also doped with hydrous ferric oxide (HFO), an amorphous iron (Fe) oxyhydroxide. When deployed in the field, HFO-doped gels introduce a fresh sorbent into the subsurface thus allowing assessment of in situ sorption. In this study, clear and HFO-doped gels were tested under laboratory conditions to constrain the gel behavior prior to field deployment. Both types of gels were allowed to equilibrate with solutions of varying composition and re-equilibrated in acid for analysis. Clear gels accurately measured solution concentrations ({+-}1%), and As was completely recovered from HFO-doped gels ({+-}4%). Arsenic speciation was determined in clear gels through chromatographic separation of the re-equilibrated solution. For comparison to speciation in solution, mixtures of As(III) and As(V) adsorbed on HFO embedded in gel were measured in situ using X-ray absorption spectroscopy (XAS). Sorption densities for As(III) and As(V) on HFO embedded in gel were obtained from sorption isotherms at pH 7.1. When As and phosphate were simultaneously equilibrated (in up to 50-fold excess of As) with HFO-doped gels, phosphate inhibited As sorption by up to 85% and had a stronger inhibitory effect on As(V) than As(III). Natural organic matter (>200 ppm) decreased As adsorption by up to 50%, and had similar effects on As(V) and As(III). The laboratory results provide a basis for interpreting results obtained by deploying the gel probe in the field and elucidating the mechanisms controlling As partitioning between solid and dissolved phases in the environment.

47 OTHER INSTRUMENTATION↗

A Gel Probe Equilibrium Sampler for Measuring Arsenic Porewater Profiles And Sorption Gradients in Sediments: Ii. Field Application to Haiwee Reservoir Sediment

Arsenic (As) geochemistry and sorption behavior were measured in As- and iron (Fe)-rich sediments of Haiwee Reservoir by deploying undoped (clear) polyacrylamide gels and hydrous ferric oxide (HFO)-doped gels in a gel probe equilibrium sampler, which is a novel technique for directly measuring the effects of porewater composition on As adsorption to Fe oxides phases in situ. Arsenic is deposited at the sediment surface as As(V) and is reduced to As(III) in the upper layers of the sediment (0-8 cm), but the reduction of As(V) does not cause mobilization into the porewater. Dissolved As and Fe concentrations increased at depth in the sediment column driven by the reductive dissolution of amorphous Fe(III) oxyhydroxides and conversion to a mixed Fe(II, III) green rust-type phase. Adsorption of As and phosphorous (P) onto HFO-doped gels was inhibited at intermediate depths (10-20 cm), possibly due to dissolved organic or inorganic carbon, indicating that dissolved As concentrations were at least partially controlled by porewater composition rather than surface site availability. In sediments that had been recently exposed to air, the region of sorption inhibition was not observed, suggesting that prior exposure to air affected the extent of reductive dissolution, porewater chemistry, and As adsorption behavior. Arsenic adsorption onto the HFO-doped gels increased at depths >20 cm, and the extent of adsorption was most likely controlled by the competitive effects of dissolved phosphate. Sediment As adsorption capacity appeared to be controlled by changes in porewater composition and competitive effects at shallower depths, and by reductive dissolution and availability of sorption sites at greater burial depths.

54 ENVIRONMENTAL SCIENCES↗

A suspended-particle rosette multi-sampler for discrete biogeochemical sampling in low-particle-density waters

To enable detailed investigations of early stage hydrothermal plume formation and abiotic and biotic plume processes we developed a new oceanographic tool. The Suspended Particulate Rosette sampling system has been designed to collect geochemical and microbial samples from the rising portion of deep-sea hydrothermal plumes. It can be deployed on a remotely operated vehicle for sampling rising plumes, on a wire-deployed water rosette for spatially discrete sampling of non-buoyant hydrothermal plumes, or on a fixed mooring in a hydrothermal vent field for time series sampling. It has performed successfully during both its first mooring deployment at the East Pacific Rise and its first remotely-operated vehicle deployments along the Mid-Atlantic Ridge. It is currently capable of rapidly filtering 24 discrete large-water-volume samples (30-100 L per sample) for suspended particles during a single deployment (e.g. >90 L per sample at 4-7 L per minute through 1 {mu}m pore diameter polycarbonate filters). The Suspended Particulate Rosette sampler has been designed with a long-term goal of seafloor observatory deployments, where it can be used to collect samples in response to tectonic or other events. It is compatible with in situ optical sensors, such as laser Raman or visible reflectance spectroscopy systems, enabling in situ particle analysis immediately after sample collection and before the particles alter or degrade.

54 ENVIRONMENTAL SCIENCES↗

Deployment of portable, modular gas samplers as part of an atmospheric tracer experiment

Underground nuclear explosions release noble gases into the atmosphere that can be detected to support international monitoring efforts. Atmospheric transport models help predict the movement of these gases over long distances, but struggle to predict the movement in the atmosphere local to the release. A field experiment was designed to monitor the movement of 127 Xe within a 5-km radius. Four gas samplers were deployed as part of this experiment to collect atmospheric samples at various distances from the release point. In conclusion, these samples were then analyzed in a near-field lab using a NaI detector and in an off-site lab using gamma-gamma coincidence and beta-gamma coincidence counting.

Radioxenon↗

Analysis of measurements from an array of radioxenon samplers near to Hartlepool Nuclear Power Station

As part of a scientific research and development project, the radionuclide fingerprint of an operating advanced gas-cooled reactor 25 (AGR) has been studied across several facets (Goodwin et al., 2024). One part of this project was to deploy an array of 26 radioxenon samplers to the region for a period of around 1 year, to measure any radioxenon emissions from the reactors of the 27 Hartlepool nuclear power station at a range of tens of kilometres away. The array of 3 sensors was operational for around 12 28 months from March 2022 and detected many occurrences of isotopes of radioxenon. Here we provide a detailed analysis and 29 interpretation of the data and where possible, attribution of detections to a source or region. Whilst a key part of this work is to 30 measure any emissions of radioxenon from Hartlepool, this work presents one of the most comprehensive efforts to determine the 31 source of a great number of (mostly) 133Xe detections. A combination of different types of atmospheric dispersion modelling 32 techniques, including the use of stack monitoring data from nearby civil radioxenon-emitting nuclear facilities has enabled the 33 majority of detections to be attributed to one or more possible sources. Whilst emissions from Hartlepool have been detected on 34 the systems, the majority of detections are associated with a medical isotope production facility in Fleurus, Belgium (IRE).

Advanced gas-cooled reactor↗

Evaluating and modeling the effects of surface sampling factors on the recovery of organic chemical attribution signatures using the accelerated diffusion sampler and solvent extraction

In this study, an experimental design matrix was created and executed in order to test the effects of various real-world factors on the ability of the (1) accelerated diffusion sampler with solid phase micro-extraction (ADS-SPME) and (2) solvent extraction to capture organic chemical attribution signatures (CAS) from dimethyl methylphosphonate (DMMP) spiked onto painted wall board (PWB) surfaces. The DMMP CAS organic impurities sampled by ADS-SPME and solvent extraction were analyzed by gas chromatography/mass spectrometry (GC/MS). The number of detected DMMP CAS impurities and their respective GC/MS peak areas were determined as a function of DMMP stock, DMMP spiked volume, exposure time, SPME sampling time, and ADS headspace pressure. Based on the statistical analysis of experimental results, several general conclusions are made: (1) ADS-SPME with vacuum (i.e., reduced pressure) increased the amount of detected CAS impurity, as measured by GC/MS peak area, by a factor of 1.7 to 1.9 for PWB under certain experimental conditions, (2) the amount of detected CAS impurity was most influenced by spiked volume, stock, and ADS headspace pressure, (3) the ADS had no measurable effect on the number of detected DMMP impurities, that is, the ADS (with and without reduced pressure) had no practical effect on the DMMP impurity profile collected from spiked PWB, and (4) solvent extraction out performed ADS-SPME in terms of consistently capturing all or most of the targeted DMMP impurities from spiked PWB.

36 MATERIALS SCIENCE↗

Quantification of Mercury Bioavailability for Methylation Using Diffusive Gradient in Thin-Film Samplers

Here, mercury-contaminated sediment and water contain various Hg species, with a small fraction available for microbial conversion to the bioaccumulative neurotoxin monomethylmercury (MeHg). Quantification of this available Hg pool is needed to prioritize sites for risk management. This study compared the efficacy of diffusive gradient in thin-film (DGT) passive samplers to a thiol-based selective extraction method with glutathione (GSH) and conventional filtration (<0.2 μm) as indicators of Hg bioavailability. Anaerobic sediment slurry microcosms were amended with isotopically labeled inorganic Hg “endmembers” (dissolved Hg 2+ , Hg-humic acid, Hg-sorbed to FeS, HgS nanoparticles) with a known range of bioavailability and methylation potentials. Net MeHg production (expressed as percent of total Hg as MeHg) over 1 week correlated with mass accumulation of Hg endmembers on the DGTs and only sometimes correlated with the 0.2 μm filter passing Hg fraction and the GSH-extractable Hg fraction. These results suggest for the first time that inorganic Hg uptake in DGTs may indicate bioavailability for methylating microbes. Moreover, the methylating microbial community assessed by hgcA gene abundance was not always consistent with methylation rates between the experiments, indicating that knowledge of the methylating community should target the transcript or protein level. Altogether, these results suggest that DGTs could be used to quantify the bioavailable Hg fraction as part of a method to assess net MeHg production potential in the environment.

54 ENVIRONMENTAL SCIENCES↗

File Comparison Sampler

The file Comparison Sampler console application compares two or more files (typically in separate folders) to check whether the start of the files match, the end of the files match, and selected sections inside the files also match. It is useful for comparing large files without reading the entire file. Alternatively, you can provide two folder paths and the program will compare all of the files in the first folder to the identically named files in the second folder.

Monroe, Matthew↗

Bug fixes / enhancements to Parallel tempering Markov chain Monte Carlo sampler (PTMCMCSampler) v3

Markov chain Monte Carlo sampler useful for a variety of problems for optimization, numerical integration, and generating draws from a probability distribution. They are often used in physical and mathematical problems, especially when it is difficult or impossible to use other approaches. This disclosure is for new bug fixes and enhancements to an existing open source library that is already in the public domain under the MIT license. https://github.com/jellis18/PTMCMCSampler

Forrer, Mark↗

Particle-into-Liquid Sampler (PILS) Instrument Handbook

The Particle-into-Liquid Sampler (PILS) is an aqueous-solution-based online technique for determining bulk chemical composition of ambient aerosol particles. As shown in Figure 1, the instrument consists of two units, briefly described below: 1. An aerosol extraction unit where particles are passed through a growth chamber saturated with water vapor, liquid droplets are grown, and the resulting liquid collected and transferred to the detection system. 2. The detection system that includes ion chromatographs (IC) or a total organic carbon detector (TOC). Ion chromatography is performed using two Metrohm ICs—one for positive ions and one for negative ions—with conductivity detectors. The TOC is detected using a GE TOC analyzer. The instrument can be run in either the ion detection mode or the TOC mode.

54 ENVIRONMENTAL SCIENCES↗

Next-Generation Video Ice Particle Sampler Field Campaign Report

The next-generation video ice particle sampler (ngVIPS) was operated on the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) during the IFFExO (Ice Fog Field Experiment at Oliktok Point) project in November, 2020. The purpose of the project was to study ice fog microphysics and the environmental conditions during ice fog to enable better predictions during low-visibility conditions. This project was conducted at the site of the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska. Among a suite of other instruments, the ngVIPS was operated to observe atmospheric ice particles.

47 OTHER INSTRUMENTATION↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗