Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAW device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Empirical study of the interaction of silicon substrate thinness, device design, and solar cell processing

Processing experiments using wire-saw techniques to slice thin silicon wafers are described. Substrates were sliced directly to 17 mil, 8 mil, and 5 mil thicknesses. Some of the 8 mil substrates and all of the 5 mil substrates were chemically etched to 7 and 4 mils, respectively, to guarantee removal of any saw damage. The wafers wire sawed to 17 mil thicknesses were processed as reference cells. A baseline process which results in an n(+)-p cell structure, and two advanced processes which provide n(+)-p-p(+) structures were utilized. By using a p(+) enhancement layer on the solar cell back surface, the performance of the 7 mil wafers was increased to exceed that of the 17 mil solar cells with simple n(+)-p structures. Cells fabricated by an ion implantation sequence utilizing elemental boron and phosphorus implants were shown to be capable of equalling or exceeding the performance of cells fabricated by an equivalent all-diffusion process.

Pryor, R. A.↗

Vacuum Packaging of MEMS With Multiple Internal Seal Rings

A proposed method of design and fabrication of vacuum-packaged microelectromechanical systems (MEMS) and of individual microelectromechanical devices involves the use of multiple internal seal rings (MISRs) in conjunction with vias (through holes plated with metal for electrical contacts). The proposed method is compatible with mass production in a wafer-level fabrication process, in which the dozens of MEMS or individual microelectromechanical devices on a typical wafer are simultaneously vacuum packaged by bonding a capping wafer before the devices are singulated (cut apart by use of a dicing saw). In addition to being compatible with mass production, the proposed method would eliminate the need for some complex and expensive production steps and would yield more reliable vacuum seals. Conventionally, each MEMS or individual microelectromechanical device is fabricated as one of many identical units on a device wafer. Vacuum packaging is accomplished by bonding the device wafer to a capping wafer with metal seal rings (one ring surrounding each unit) that have been formed on the capping wafer. The electrical leads of each unit are laid out on what would otherwise be a flat surface of the device wafer, against which the seal ring is to be pressed for sealing. The resulting pattern of metal lines and their insulating oxide coverings presents a very rough and uneven surface, upon which it is difficult to pattern the sealing metal. Consequently, the seal is prone to leakage unless additional costly and complex planarization steps are performed before patterning the seal ring and bonding the wafers.

Hayworth, Ken↗

The neurochemical and neuropharmacological basis of motion sickness

An apparatus suitable for producing motion sickness in laboratory animals and constructed at the university is herein described. The apparatus is a modified version of that previously described by Fox and Daunton. It consists of a 66-inch steel arm anchored at the center to a wooden platform and attached to a motor that makes the arm move in a see-saw fashion. At each end of the steel arm is mounted an aluminum disc that can be rotated by a motorized device. Detachable cages are mounted on each disc for animal holding. The animal can then be exposed to rotational motion by rotation of the aluminum disc, or to see-saw motion simultaneously (Cross-coupled). The apparatus is presently being used in our laboratory to study the neuropharmacological basis of motion sickness in the rat. The device can be adapted for use with other animal species by modifying the cage mounted on the aluminum discs.

Walker, C. A.↗

Wireless SAW Sensors Having Integrated Antennas

A wireless surface acoustic wave sensor includes a piezoelectric substrate, a surface acoustic wave device formed on the substrate, and an antenna formed on the substrate. In some embodiments, the antenna is formed on the surface of the substrate using one or more of photolithography, thin film processing, thick film processing, plating, and printing.

Gallagher, Mark↗

NASA Tech Briefs, February 2003

opics covered include: Integrated Electrode Arrays for Neuro-Prosthetic Implants; Eroding Potentiometers; Common/Dependent-Pressure-Vessel Nickel-Hydrogen Batteries; 120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna; 80-GHz MMIC HEMT Voltage-Controlled Oscillator; High-Energy-Density Capacitors; Microscale Thermal-Transpiration Gas Pump; Instrument for Measuring Temperature of Water; Improved Measurement of Coherence in Presence of Instrument Noise; Compact Instruments Measure Helium-Leak Rates; Irreversible Entropy Production in Two-Phase Mixing Layers; Subsonic and Supersonic Effects in Bose-Einstein Condensate; Nanolaminate Mirrors With "Piston" Figure-Control Actuators; Mixed Conducting Electrodes for Better AMTEC Cells; Process for Encapsulating Protein Crystals; Lightweight, Self-Deployable Wheels; Grease-Resistant O Rings for Joints in Solid Rocket Motors; LabVIEW Serial Driver Software for an Electronic Load; Software Computes Tape-Casting Parameters; Software for Tracking Costs of Mars Projects; Software for Replicating Data Between X.500 and LDAP Directories; The Technical Work Plan Tracking Tool; Improved Multiple-DOF SAW Piezoelectric Motors; Propulsion Flight-Test Fixture; Mechanical Amplifier for a Piezoelectric Transducer; Swell Sleeves for Testing Explosive Devices; Linear Back-Drive Differentials; Miniature Inchworm Actuators Fabricated by Use of LIGA; Using ERF Devices to Control Deployments of Space Structures; High-Temperature Switched-Reluctance Electric Motor; System for Centering a Turbofan in a Nacelle During Tests; Fabricating Composite-Material Structures Containing SMA Ribbons; Optimal Feedback Control of Thermal Networks; Artifacts for Calibration of Submicron Width Measurements; Navigating a Mobile Robot Across Terrain Using Fuzzy Logic; Designing Facilities for Collaborative Operations; and Quantitating Iron in Serum Ferritin by Use of ICP-MS.

Source record↗

Analysis of aging data on SAW oscillators

Test oscillators including delay lines and resonators in the 300-400 MHz range have been investigated with reference to the long-term stability (aging) characteristics. All devices were fabricated on rotated Y-cut quartz plates (40 deg), and either gold or platinum metallization was used; all packages were high-quality hermetic enclosures, and the mounting was strictly mechanical, with no organics or silicone rubbers used. It is shown that drift of less than 2 ppm in the first year can be obtained on a significant fraction of the devices when reasonably clean packages are used. The data also suggest that the transducer metallization (at least for aluminum) is very likely the source of the relaxation mechanism that causes the frequency drift.

Parker, T. E.↗

Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive that is, they do not require any on-board power supply such as batteries and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of current generation tags limits the performance in a cluttered sensing environment. That is, as more SAW-based sensors are added to the environment, numerous tag responses are superimposed at the receiver and decoding all or even a subset of the telemetry becomes increasingly difficult. Background clutter generated by reflectors other than the sensors themselves is also a problem, as is multipath interference and signal distortion, but the limiting factor in many remote sensing applications can be expected to be tag mutual interference. This problem may be greatly mitigated by proper design of the SAW tag waveform, but that remains an open research problem, and in the meantime, several other related questions remain to be answered including: What are the fundamental relationships between tag parameters such as bit-rate, time-bandwidth-product, SNR, and achievable collision resolution? What are the differences in optimal or near-optimal interrogator designs between noise-limited environments and interference-limited environments? What are the performance characteristics of different interrogator designs in term of parameters such as transmitter power level, range, and number of interfering tags? In this paper, we present the results of a research effort aimed at providing at least partial answers to all of these questions.

Barton, Richard J.↗

Surface acoustic wave stabilized oscillators: Additional aging results

Updated aging data for SAW oscillators with aluminum transducers on ST-cut quartz, for gold transducers on ST-cut quartz, and for aluminum transducers on SiO2/LiTaO3. Devices with gold transducers age differently (both and shape of curve) from those having a aluminum transducers indicating the transducer metallization can represent an important aging mechanism.

Source record↗

The 2.2 GHz Surface Acoustic Wave (SAW) oscillator development Ku-band frequency source development

Two 2.2 GHz SAW oscillators using aluminum nitride on sapphire (AlN/Al2O3) delay lines were fabricated. The oscillators were electronically temperature compensated and characterized. One of the oscillators was used as the frequency reference for the Ku band source; the second oscillator is available for continued evaluation. A 15 GHz frequency source was designed and fabricated. The 15 GHz source consists of a Ku band FET oscillator which is phase locked to the frequency multiplied (X7) output of the 2.2 GHz SAW reference source. The Ku band source was built using microstrip circuit designs, which are hybrid compatible. Two wafer runs of 2.2 GHz TED devices were fabricated and evaluated. The devices were mounted on microstrip test substrates and evaluated as 15 GHz divide by 7 circuits. The device evaluation indicated that in their present form the TED is not a practical circuit element.

Source record↗

Energy Servers Deliver Clean, Affordable Power

K.R. Sridhar developed a fuel cell device for Ames Research Center, that could use solar power to split water into oxygen for breathing and hydrogen for fuel on Mars. Sridhar saw the potential of the technology, when reversed, to create clean energy on Earth. He founded Bloom Energy, of Sunnyvale, California, to advance the technology. Today, the Bloom Energy Server is providing cost-effective, environmentally friendly energy to a host of companies such as eBay, Google, and The Coca-Cola Company. Bloom's NASA-derived Energy Servers generate energy that is about 67-percent cleaner than a typical coal-fired power plant when using fossil fuels and 100-percent cleaner with renewable fuels.

Source record↗

Carbon Nanofiber-Based, High-Frequency, High-Q, Miniaturized Mechanical Resonators

High Q resonators are a critical component of stable, low-noise communication systems, radar, and precise timing applications such as atomic clocks. In electronic resonators based on Si integrated circuits, resistive losses increase as a result of the continued reduction in device dimensions, which decreases their Q values. On the other hand, due to the mechanical construct of bulk acoustic wave (BAW) and surface acoustic wave (SAW) resonators, such loss mechanisms are absent, enabling higher Q-values for both BAW and SAW resonators compared to their electronic counterparts. The other advantages of mechanical resonators are their inherently higher radiation tolerance, a factor that makes them attractive for NASA s extreme environment planetary missions, for example to the Jovian environments where the radiation doses are at hostile levels. Despite these advantages, both BAW and SAW resonators suffer from low resonant frequencies and they are also physically large, which precludes their integration into miniaturized electronic systems. Because there is a need to move the resonant frequency of oscillators to the order of gigahertz, new technologies and materials are being investigated that will make performance at those frequencies attainable. By moving to nanoscale structures, in this case vertically oriented, cantilevered carbon nanotubes (CNTs), that have larger aspect ratios (length/thickness) and extremely high elastic moduli, it is possible to overcome the two disadvantages of both bulk acoustic wave (BAW) and surface acoustic wave (SAW) resonators. Nano-electro-mechanical systems (NEMS) that utilize high aspect ratio nanomaterials exhibiting high elastic moduli (e.g., carbon-based nanomaterials) benefit from high Qs, operate at high frequency, and have small force constants that translate to high responsivity that results in improved sensitivity, lower power consumption, and im - proved tunablity. NEMS resonators have recently been demonstrated using topdown, lithographically fabricated ap - proaches to form cantilever or bridgetype structures. Top-down approaches, however, rely on complicated and expensive e-beam lithography, and often require a release mechanism. Reso - nance effects in structures synthesized using bottom-up approaches have also recently been reported based on carbon nanotubes, but such approaches have relied on a planar two-dimensional (2D) geometry. In this innovation, vertically aligned tubes synthesized using a bottom- up approach have been considered, where the vertical orientation of the tubes has the potential to increase integration density even further. The simulation of a vertically oriented, cantilevered carbon nanotube was performed using COMSOL Multi - physics, a finite element simulation package. All simulations were performed in a 2D geometry that provided consistent results and minimized computational complexity. The simulations assumed a vertically oriented, cantilevered nanotube of uniform density (1.5 g/cu cm). An elastic modulus was assumed to be 600 GPa, relative permittivity of the nanotube was assumed to be 5.0, and Poisson s ratio was assumed to be 0.2. It should be noted that the relative permittivity and Poisson s ratio for the nanotubes of interest are not known accurately. However, as in previous simulations, the relative permittivity and Poisson s ratios were treated as weak variables in the simulation, and no significant changes were recognized when these variables were varied.

Kaul, Anupama B.↗

A high sensitivity real-time NVR monitor

The use of a temperature-controlled 200-MHz SAW resonator piezoelectric mass microbalance to monitor the mass of nonvolatile residue (NVR) deposited on its surface in real time is reported. The fundamental frequency of this device is mainly dependent on the configuration of the transducers and not on the thickness of the substrate. Therefore, higher operating frequencies can be achieved without reducing the thickness of the crystal. The real-time instrument was integrated onto a conventional stainless steel NVR plate and operated flawlessly over a 14-d period at Kennedy Space Center and successfully measured less than 1 ng/sq cm d NVR contamination. Contamination episodes detected by the instrument were correlated with scheduled activities on the test stand. Under the assumption of a baseline noise level of +/- 2 Hz, the absolute mass lower limit of detection would be 0.065 ng/sq cm. This would enable the detection of a daily NVR deposition rate of less than 0.1 ng/sq cm d.

Bowers, William D.↗

Guidelines for Reliable DC/DC Converters for Space Use

NESC saw the need to study the persistent failure of DC/DC Converters during ground testing and in flight, motivated investigation of causes and mitigation options. Research indicated misapplication and device quality to be root causes. The study took 20 months. Team included multiple NASA Centers : JPL, JSC, MSFC, GSFC Project Background

Plante, Jeannette↗

A Flight Investigation of the Lateral Control Characteristics of Short Wide Ailerons and Various Spoilers with Different Amounts of Wing Dihedral

This report presents the results of flight tests made to determine the lateral control characteristics of short wide ailerons and spoilers, as a consequence of the promise shown in wind-tunnel tests by these devices as means of obtaining lateral control, particularly at angles of attack above the stall. Several forms of spoilers, front-hinge, rear-hinge, plain retractable, and saw-tooth retractable were tested alone and in combination with the ailerons. The tests were made with several different amounts of wing dihedral so that the effect of the yawing moments of the different lateral control combinations, which varied from large negative to large positive values, could be evaluated. In conjunction with the tests, observations were made to throw some light on the feasibility of operating the airplane with two controls instead of the present three.

Weick, Fred E↗

Weighted SAW reflector gratings for orthogonal frequency coded SAW tags and sensors

Weighted surface acoustic wave reflector gratings for coding identification tags and sensors to enable unique sensor operation and identification for a multi-sensor environment. In an embodiment, the weighted reflectors are variable while in another embodiment the reflector gratings are apodized. The weighting technique allows the designer to decrease reflectively and allows for more chips to be implemented in a device and, consequently, more coding diversity. As a result, more tags and sensors can be implemented using a given bandwidth when compared with uniform reflectors. Use of weighted reflector gratings with OFC makes various phase shifting schemes possible, such as in-phase and quadrature implementations of coded waveforms resulting in reduced device size and increased coding.

Puccio, Derek↗

Time-lapse CCD imagery of plasma-tail motions in Comet Austin

The appearance of the bright comet Austin 1989c1 in April-May of 1990 allowed us to test a new imaging instrument at the Joint Observatory for Cometary Research (JOCR). It is a 300mm lens/charge coupled device (CCD) system with interference filters appropriate for cometary emissions. The 13 frames were made into a time-lapse movie showing the evolution of the plasma tail. We were able to follow at least two large-scale waves out through the main tail structure. During the sequence, we saw two new tail rays form and undergo similar wave motion.

Klinglesmith, Daniel A., III↗

Investigation of Combustion Control in a Dump Combustor Using the Feedback Free Fluidic Oscillator

A feedback free fluidic oscillator was designed and integrated into a single element rocket combustor with the goal of suppressing longitudinal combustion instabilities. The fluidic oscillator uses internal fluid dynamics to create an unsteady outlet jet at a specific frequency. An array of nine fluidic oscillators was tested to mimic modulated secondary oxidizer injection into the combustor dump plane. The combustor has a coaxial injector that uses gaseous methane and decomposed hydrogen peroxide with an overall O/F ratio of 11.7. A sonic choke plate on an actuator arm allows for continuous adjustment of the oxidizer post acoustics enabling the study of a variety of instability magnitudes. The fluidic oscillator unsteady outlet jet performance is compared against equivalent steady jet injection and a baseline design with no secondary oxidizer injection. At the most unstable operating conditions, the unsteady outlet jet saw a 67% reduction in the instability pressure oscillation magnitude when compared to the steady jet and baseline data. Additionally, computational fluid dynamics analysis of the combustor gives insight into the flow field interaction of the fluidic oscillators. The results indicate that open loop high frequency propellant modulation for combustion control can be achieved through fluidic devices that require no moving parts or electrical power to operate.

Meier, Eric J.↗

A Comparison of Surface Acoustic Wave Modeling Methods

Surface Acoustic Wave (SAW) technology is low cost, rugged, lightweight, extremely low power and can be used to develop passive wireless sensors. For these reasons, NASA is investigating the use of SAW technology for Integrated Vehicle Health Monitoring (IVHM) of aerospace structures. To facilitate rapid prototyping of passive SAW sensors for aerospace applications, SAW models have been developed. This paper reports on the comparison of three methods of modeling SAWs. The three models are the Impulse Response Method a first order model, and two second order matrix methods; the conventional matrix approach, and a modified matrix approach that is extended to include internal finger reflections. The second order models are based upon matrices that were originally developed for analyzing microwave circuits using transmission line theory. Results from the models are presented with measured data from devices.

Wilson, W. c.↗